• Title/Summary/Keyword: Electrical Analysis

Search Result 18,976, Processing Time 0.062 seconds

Power Losses Reduction via Simultaneous Optimal Distributed Generation Output and Reconfiguration using ABC Optimization

  • Jamian, Jasrul Jamani;Dahalan, Wardiah Mohd;Mokhlis, Hazlie;Mustafa, Mohd Wazir;Lim, Zi Jie;Abdullah, Mohd Noor
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1229-1239
    • /
    • 2014
  • Optimal Distributed Generation (DG) output and reconfiguration are among the well accepted approach to reduce power loss in a distribution network. In the past, most of the researchers employed optimal DG output and reconfiguration separately. In this work, a simultaneous DG output and reconfiguration analysis is proposed to maximize power loss reduction. The impact of the separated analysis and simultaneous analysis are investigated. The test result on the 33 bus distribution network with 3 units of DG operated in PV mode showed the simultaneous analysis gave the lowest power loss (global optimal) and faster results compared to other combined methods. All the analyses for optimizing the DG as well as reconfiguration are used the Artificial Bee Colony Optimization technique.

Characteristic Analysis of Automotive Starter Motor with auxiliary Pole Core (보조극을 가지는 자동차 시동용 전동기의 특성분석)

  • Ha, Jae-Pyeong;Ha, Kyeong-Ho;Hong, Joung-Pyo;Jo, Jae-Ok;Kim, Jin-Gu;Song, Jae-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.753-755
    • /
    • 2002
  • This paper presents the characteristic analysis by changing the shape and position of auxiliary pole core for Automotive stater motor. The brush contact resistance and mechanical loss calculated from the experimental data are used in characteristic analysis. The Finite Element Analysis Method(FEM) and 3D Equivalent Magnet Circuit Network(EMCN) are used for analysis. The validity of the proposed methods are verified by comparison of analysis results and experimental ones.

  • PDF

Optimal Design of Ferromagnetic Pole Pieces for Transmission Torque Ripple Reduction in a Magnetic-Geared Machine

  • Kim, Sung-Jin;Park, Eui-Jong;Kim, Yong-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1628-1633
    • /
    • 2016
  • This paper derives an effective shape of the ferromagnetic pole pieces (low-speed rotor) for the reduction of transmission torque ripple in a magnetic-geared machine based on a Box-Behnken design (BBD). In particular, using a non-linear finite element method (FEM) based on 2-D numerical analysis, we conduct a numerical investigation and analysis between independent variables (selected by the BBD) and reaction variables. In addition, we derive a regression equation for reaction variables according to the independent variables by using multiple regression analysis and analysis of variance (ANOVA). We assess the validity of the optimized design by comparing characteristics of the optimized model derived from a response surface analysis and an initial model.

Analysis of Cogging Torque in Interior Permanent Magnet Motor by Analytical Method

  • Kang, Gyu-Hong;Hong, Jung-Pyo;Kim, Gyu-Tak
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.2
    • /
    • pp.1-8
    • /
    • 2001
  • This paper deals with magnetic field analysis and computation of cogging torque using an analytical method in Interior Permanent Magnet Motor (IPMM). The magnetic field is analyzed by solving space harmonics field analysis due to magnetizing and the cogging torque is analyzed by combining field analysis with relative permeance. In reducing cogging torque, the inferences of various design variable and magnetizing distribution are investigated. It is shown that the slot and pole ratio (the pole-arc / pole-pitch ratio) combination has a significant effect on the cogging torque and presents a optimal flux barrier shape to reduce the cogging torque. The validity of the proposed technique is confirmed with 2-D Finite Element(FE) analysis.

Fault Diagnostic Expert System Using Dissolved Gas Analysis in Transformer (유중가스를 이용한 변압기 고장진단용 전문가 시스템 개발)

  • Jeon, Young-Jae;Yoon, Yong-Han;Kim, Jae-Chul;Yun, Sang-Yun;Choi, Do-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.859-861
    • /
    • 1996
  • This paper presents the novel fault diagnostic expert system based on dissolved gas analysis(DGA) techniques in power transformer. The uncertainty of key gas analysis, norm threshold, and gas ratio boundaries are managed by using a fuzzy set concept. The uncertainty of rules are handled by fuzzy measures. Trend analysis through the monthly increment of key gas and DGA analysis are combined by the Dempster-Shafer theory, and the state of transformer and confidence factor are yielded by using this combined analysis. To verify the effectiveness of the proposed diagnosis technique, the expert system has been tested by using KEPCO's transformer gas records.

  • PDF

The Study on the Characteristic Analysis of Three Phase Induction Motor For Electric Forklift Truck Using Finite Element Method (유한요소법을 이용한 전동지게차용 3상 유도전동기 특성 해석 연구)

  • Kim, Kwang-Soo;Im, Jong-Bin;Lee, Sang-Hoon;Won, Sung-Hong;Koo, Dae-Hyun;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1059-1060
    • /
    • 2007
  • In this paper analysis of the characteristics in the three phase induction motor for the electric forklift truck is researched. There are two kinds of the Finite element analysis method. First thing is time domain analysis by the time transient method. Second thing is frequency domain analysis by method which assumes applied voltage and current sinusoidal. Especially in case of the characteristic studies, electromagnetic analysis is performed about each prototype motors. The obtained results are compared and the result of the test is examined. We could know characteristics of each prototypes and verify the design program of the motor through FEM. Finally this paper shows the factors of discord results of the analysis.

  • PDF

Development of H/W and S/W for Detecting Electrical Fire Precursor Signal on Electrical Wirings (배선에서 전기화재 전조신호 검출을 위한 H/W 및 S/W 구축)

  • Kim, Sung-Chul;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.3
    • /
    • pp.13-18
    • /
    • 2009
  • This paper is purposed to develop DAQ H/W, S/W and DB which can be used in developing electrical fire alarm system or in analyzing electrical fire cause, by detecting and monitoring precursor signals which have high possibility leading to electrical fire on electrical distribution wires. In this paper, developed was DAQ H/W adopting the C8051FXXX CPU which can analyze the measurement signals of current and voltage in electrical distribution wires, other CPU was investigated in view of the best digital sampling rate on the basis of previous researches for electrical fire alarm system. Also, the S/W which can interface with DAQ H/W's communication protocol and can be applied for electrical fire causes analysis, are embodied by LabVIEW. The combined DAQ H/W and S/W could analyze efficiently normal as well as abnormal electrical signals such as RMS value, instantaneous value of current and voltage, frequency signals etc, on the electrical wires. Also, DB system was constructed for recording various analysis results for precursor signals including voltage and current signals. The results by simulator and experiment showed that the suggested scheme with DAQ H/W, S/W and DB in this paper has high usability.

The Analysis of Effect for Photocoupler by Narrow-Band High-Power Electromagnetic Wave (협대역 고출력 전자기파에 의한 포토커플러 영향 분석)

  • Lee, Sung-Woo;Huh, Chang-Su;Seo, Chang-Su;Jin, In-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.1
    • /
    • pp.1-5
    • /
    • 2018
  • This study analyzed the change of electrical characteristics of a photocoupler when a narrow-band electromagnetic wave was combined with the photocoupler. A magnetron (3 kW, 2.45 GHz) was used as the narrow-band electromagnetic source. The EUT was Photocoupler (6N139) and the input signal was divided into two types: a square pulse and the second signal is 0 V. The malfunction of the photocoupler was confirmed by monitoring the variation in the output voltage of the photocoupler. As a result of the experiment, changes in the malfunctioning was observed as the electric field was increased. There are three types of malfunction modes: delay, output voltage off, and fluctuation. Bit errors were analyzed to verify the electrical characteristics of the photocoupler by narrow-band electromagnetic waves. The result of this study can be used as basic data for the effect analysis of photocoupler protection and impact analysis of high-power electromagnetic waves.

Finite Element Analysis of BLDC Motor Characteristic according to Magnetic Property Measurement Methods (자성 측정 방법에 따른 BLDC 전동기의 전자계 특성해석)

  • Kim, Ji-Hyun;Ha, Kyung-Ho;Kwon, Oh-Yeoul;Cha, Sang-Yoon;Kim, Jae-Kwan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.697-698
    • /
    • 2008
  • This paper deals with finite element characteristic analysis of brushless DC motor according to magnetic property measurement methods. Magnetic property data for non-oriented (NO) electrical steel for electric motors are measured by the Epstein test which is considered as the international standards. Data from Epstein test may result in discrepancy from motor characteristic tests due to innate anisotropic property of NO electrical steel. Finite element analysis were performed for a BLDC motor by various measurement methods such as Epstein test, Ring test and single sheet test (SST), and calculated results were compared with considering anisotropic property conditions.

  • PDF

A Fast Algorithm of the Apparent Factor Calculation for Distance Relay Setting without Fault Analysis

  • Jo, Yong-Hwan;Xiang, Ling;Choi, Myeon-Song;Park, Ji-Seung;Lim, Seong-Il;Kim, Sang-Tae;Lee, Seung-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.64-69
    • /
    • 2013
  • For power system protection, the distance relay settings are important. Apparent factor is a necessary parameter in distance relay settings. Apparent factors have to be calculated when setting the distance relays and doing the resetting in case of configuration change in power system. The problem is that the current method to calculate apparent factor requires tools and plenty of time to do fault analysis and this method is complex especially in case of configuration change. Therefore this paper proposes a fast algorithm to calculate apparent factor without the fault analysis. Test results prove that this algorithm is simple and accurate by simulation.