• Title/Summary/Keyword: Electrical Accidents

Search Result 476, Processing Time 0.04 seconds

The Analysis of Field Condition for Power Receiving System and Patch and Panel Boards at Construction Sites (건설현장의 수전설비 및 배.분전반의 현장실태 분석)

  • Gil, Hyoung-Jun;Han, Woon-Ki;Kim, Hyang-Kon;Choi, Chung-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.335-340
    • /
    • 2004
  • To analyze risk factors of temporary power installations, the investigation was carried out for power receiving system and pack and panel boards at construction sites. The subject was variable such as an airport, an apartment, a municipal playground. There are many risk factors caused by inadequate working environments and the deterioration of temporary power installations using equipment with minimum safety devices at construction sites. There, it is intended to present problems and preventive measures against electrical shock accidents, through analyzing risk factors of real field condition and investigating temporary power installations all over the country.

  • PDF

The Operational Characteristics of High-speed Interrupter by Fault Types (고장 유형별 고속 인터럽터의 동작 특성)

  • Jeong, In-Sung;Choi, Hyo-Sang;Jung, Byung-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.278-283
    • /
    • 2013
  • With the increasing power demands, size of the fault current in electrical grids is steadily increasing, and it exceeds the breaking capacity of circuit breakers. To effectively cope with these problems, a high-speed interrupter was suggested. The high-speed interrupter provides fault current with a bypass to a fault current limiter in case of accidents and consequently, fault current can be restricted. In this study, behavioral characteristics of high-speed interrupter were analyzed by accident types occurred in a distribution system. When accidents occurred, a and b contact of the high-speed interrupter were turned-off and then, turned-on. Accordingly, fault current flowed to the circuit connected to a current limiting element, and the fault current limiter restricted fault current to within a half-cycle. Nevertheless, the behavior of the high-speed interrupter was slowed down by a switching surge. As a result, fault current was confirmed to be restricted not to within the anticipated half-cycle, but to after a half-cycle. Moreover, the behavioral characteristics of the high-speed interrupter changed not only by accident types, but by behaviors of R, S, and T phases. This was due to the errors in stroke lengths of the high-speed interrupters, which resulted in a slight time discrepancy among three interrupters. In addition, the switching behaviors of the b and a contact were confirmed not to have coincided due to the switching surge; b contact behaved first and a contact followed. because of this, accuracy of stroke length and switching surges through the solenoid suction increases may be necessary to resolve.

A Risk Assessment in According to Spot Measures and Analysis in Dust Generation Area (분진발생지역의 현장실측과 분석을 통한 위험성 평가)

  • Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.103-110
    • /
    • 2008
  • In terms of electrical safety, environmental impact assessment and revision of domestic regulation are needed for the electric facilities. In this paper, risk of electric facilities is assessed by the spot measures and analysis in dust generation area. Adhesion dust in a surface of insulated materials cause electrical accidents. In a mechanism of these accidents, when the dust lie on electric facilities, a leakage current is flowed and the surface of insulated material is carbonized. Hereafter, electrical fire is generated due to Joule's heat. As the results, dusts are found in protection devices or panel board and sampled dusts vary in sampled amounts and conductivity severally. For the most part, sodium is detected but zinc and calcium are detected in case of reclaimed rubber factory by the ICP-AES(Inductively Coupled Plasma-Atomic Emission Spectroscopy). In a sewerage, the ingredients such as sodium, magnesium, iron, calcium, aluminium, etc are detected uniformly. So that, results of the spot measures and analysis of dusts are become the important data for the assessment of electrical hazard in dust generation area.

The Development of the Analysis Program for the Electric Shock Accidents Occurred in the TN and TT System (TN 및 TT 계통에서의 감전사고 분석 프로그램 개발)

  • Lee, Seok-Won;Ryu, Bo-Hyuk;Kim, Hyung-Seok;Jung, Won-Jae
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.32-38
    • /
    • 2009
  • According to the statistics from the Ministry of labor, 70~80 people died by work-related electric shock accidents in the workplace and this number is about 10~20 times higher than those of the foreign countries such as Japan and the United Kingdom in frequencies and rates per 100,000. The electrocution deaths had decreased from several hundred in 1990s to 67 in 2002, since then there has been little change over the last 5 years. To reduce this number of the electrocution death, it is necessary to analyze the sources of the accidents and to implement the suitable measures for preventing the similar accidents from occurring. But there is not any consensus standard method or procedures for accident investigation yet. And the results solely depend on the ability of the investigator. Because of the demand of eliminating technical barrier for free trading, the IEC 60364 is adopted as a regulation for low voltage electrical installations in Korea. The facilities designed and constructed by IEC 60364 are increasing. The facilities by IEC 60364 have different features in comparison with the facilities by Korea eletro technical regulation, and these features combined with parameters of electric shock accident can greatly affect the consequences of the electric accidents. The accident analysis program for electric shock injuries in Terra Neutral(TN) and Terra Terra(TT) system was developed in this paper, which was based on KOSHA Electric Shock Analysis Program(ESAP).

The Analysis of Deterioration Characteristics by Poor Contact at the Connection Part of Power Cord (전원코드 접속부에서의 접촉불량에 의한 열화특성 분석)

  • Kim, Hyang-Kon;Lee, Ki-Yoen;Moon, Hyun-Wook;Kim, Hyeog-Soo;Kim, Myung-Soo;Kim, Man-Geon
    • Congress of the korean instutite of fire investigation
    • /
    • 2010.06a
    • /
    • pp.66-81
    • /
    • 2010
  • In this study, we experimented and analyzed deterioration characteristics of outlets and power cord sets caused by poor contact. Electrical waveforms were measured according to load size and elapsed time. After that, surface structure and deteriorated characteristics of conductive materials and insulators were analyzed. We hope that the results will be applicable to electrical fire prevention and accidents analysis.

  • PDF

An Epidemiological Observation of Fire Accident in Korea (화재사고(火災事故)(WHO-E 916)에 관(關)한 역학적관찰(疫學的觀察))

  • Lee, Chong-Dae;Han, Seong-Un;Bin, Soon-Duk;Chu, In-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.1 no.1
    • /
    • pp.43-49
    • /
    • 1968
  • Epidemiological and statistical observations were made of fire hazards that occurred during the past 18 years, 1948 to 1965. Injury and mortality rates for all ages were computed chronologically. For the years of 1955, 1961 and 1965, all fire accidents were epidemiologically analysed to draw characteristic patterns in relation to the seasonal and 24 hour distribution, causes and sites of accidents etc.. Fire hazards observed herein are the categorys E 916 of the International Classification of Causes of Death, 1955, and includes all accidents caused by fire and explosion of combustible materials. The following conclusion was made: 1. The average number of annual deaths due to fire was 183 and the number of the in jured due to the same cause was 335. The mortality rate per 100,000 population was 0.8 and the ratio of injuries per death was 1.83. 2. The casually rate including both the dead and injured was 5.0 per 100,000 in Seoul, the highest among the provinces and followed by 3.4 in Cheju -Do, 2.1 in Kangwon-Do, 1.7 in Kyunggi-Do accordingly. The other provinces had a range of 0.6 to 1.2. 3. The monthly distribution of fro accidents showed that the winter months, December through February, had more frequent accidents, while the summer season, June through August had less. The 24 hour distribution of accidents showed more cases from 12:00 to 18:00 and less from 4:00 to 10:00 hours. 4. The per cent distribution of causes of accidents showed; 90.0% for careless, 10.0% for arson. The cause of carelessness was further breakdown into; 15.0% for kitchen fire places, 13.8% for fire playing, 9,4% for electrical heating and wires, 8.3% for fuels, 6.3% for matches, 5.2% for ash dumps and the remaining for others. 5. The accidents as classified by place revealed that 56.8% of the total occurred at the common dwelling houses, 11.3 at various industrial workshops, 9.3% at the street shops and the remaining at the miscellaneous places.

  • PDF

Solar Power Plant Inspection Techniques and Practices to Improve Inadequate Facilities (태양광 발전설비 검사기법 및 부적합설비 개선사례 분석)

  • Park, Byeong-Ha;Go, Seok-Il;Ahn, Seon-Ju;Choi, Joon-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.439-444
    • /
    • 2012
  • Photovoltaic energy is regarded as the key solution to the instability of energy supply and environmental pollution, and it is spreading from the developed countries to world wide. This paper looks into guide lines of KESCO (Korea electrical Safety Corporation) on Photovoltaic system and analyzed case of inconsistencies of pre-service inspection. Through these analyses it will be possible to prevent possible accidents in the process of installing Photovoltaic system and thus ensure electrical safety of Photovoltaic system.

  • PDF

The Charateristics of Flash-over Voltage by Humidity Variation for 22.9 kV Live Part (22.9 kV 노출충전부의 습도변화에 따른 섬락전압 변동 특성)

  • Han, Ki-Boong;Lee, Dae-Jong;Han, Woon-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1856-1858
    • /
    • 2002
  • As the statistical data, the most of electrical shock accidents have been caused by human errors including those of mistake, carelessness, and so on during normal condition. But, there are currently no international standards for the determination of withstand distance to ensure safety of personnel form 22.9 kV electrical power facilities during their normal operation. Therefore, this paper describes the characteristics of flash-over voltage by moisture variation to establish the distance clearances in terms of electrical safety.

  • PDF

Situation and Improvement Method of Railroad Platform Lighting (철도 승강장 조명의 현황과 개선책)

  • 김병봉;장우진;한성호
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.3-8
    • /
    • 2003
  • Platforms of many railroad stations are crowded with passengers regardless of the time throughout day. But the intensity of illumination of the existing lightening systems are so low enough to make passengers feel inconvenience in using platforms. Consequently there exists high possibility of accidents in platforms of low illumination. Hence, for the safety and convenience of passengers, it is necessary to improve the luminous intensity of lightening system for platforms. This paper points out the problems of existing system and presents the method to improve it.

  • PDF