• 제목/요약/키워드: Electric-pump Cycle

검색결과 36건 처리시간 0.03초

심야전력을 이용한 Cascade Heat Pump Cycle의 운전결과 분석 (Analysis on Cascade Cycle Heat Pump Application as Night Storage Heater)

  • 정훈;황성욱;이철희
    • 한국기계기술학회지
    • /
    • 제13권1호
    • /
    • pp.113-118
    • /
    • 2011
  • To analyze and verify the effect of replacing thermal storage heater by a cascade cycle heat pump using midnight electricity was installed and tested at a customer's house in Wonju, Korea. The electric night storage heater is consist of 30kW electric heater and 2,700 liters of thermal storage water tank to supply hot water for warming house floor. The power for electric heater was cut off and hot water was only generated by cascade cycle heat pump. Current thermal storage water tank was not eliminated and electric heater wiring was modified. Some operation logic of the heat pump was also modified for proper operation. The required capacity of the heat pump and hot water temperature for given warming condition were estimated. The estimated capacity of heat pump was about 19kW and estimated hot water temperature for proper heating was at least $75^{\circ}C$.

상단 추진 시스템에 적용을 위한 전기펌프 사이클의 국외 연구 동향 (Overseas Research Trends of an Electric-Pump Cycle for Application in Upper-Stage Propulsion Systems)

  • 기원근;이재청;이형진;노태성;허환일
    • 한국추진공학회지
    • /
    • 제24권1호
    • /
    • pp.64-77
    • /
    • 2020
  • 전기모터를 이용하여 액체로켓 엔진의 펌프를 구동하는 추진제 공급 시스템인 전기펌프 사이클은 시스템 구성이 간단하고 공급 유량 및 압력 제어가 용이한 장점이 있다. 본 논문에서는 전기펌프 사이클의 국외 연구 동향을 조사하여 분석하였다. 또한 연구개발 국가, 수행기관, 적용 대상, 엔진 추력, 펌프 압력상승, 모터 동력, 회전수 등을 정리하였다. 그 중 0.445~2.2 kN의 추력 범위를 가지는 상단 추진 시스템에 적용한 국외 연구의 설계 변수들은 국내에서 유사한 전기펌프 사이클 연구 시 활용할 수 있을 것이다.

CONTROL STRATEGY OF ELECTRIC COOLANT PUMPS FOR FUEL ECONOMY IMPROVEMENT

  • CHO H.;JUNG D.;ASSANIS D. N.
    • International Journal of Automotive Technology
    • /
    • 제6권3호
    • /
    • pp.269-275
    • /
    • 2005
  • The engine cooling system for a medium duty V6, 4.5 L diesel engine was modeled with a commercial code, GT-Cool in order to investigate the effect of controllable electric pump on the cooling performance and the fuel economy. The simulation results of the cooling system model with mechanical coolant pump were validated with experimental data. Two different types of electric pumps were implemented into the cooling system model and PID control for electric pump operation was incorporated into the simulation study. Based on the simulation result with electric pump, conventional thermostat hysteresis was modified to reduce pump operation for additional improvement of fuel economy, and then the benefit of electric pumps with modified thermostat hysteresis on fuel economy was demonstrated with the simulation. The predicted result indicates that the cooling system with electric pump and modified thermostat hysteresis can reduce pump power consumption by more than $99\%$ during the FTP 74 driving cycle.

전기펌프사이클 엔진 등 민간분야 우주발사체 신기술고찰 (New Technologies of Space Launch Vehicles including Electric-Pump Cycle Engine)

  • 정승민;김귀순;오세종;최정열
    • 한국항공우주학회지
    • /
    • 제44권2호
    • /
    • pp.139-155
    • /
    • 2016
  • 본 논문에서는 최근의 우주발사체 기술 발전에 대한 소개가 이루질 것이다. 민간 분야에서의 우주개발 사업들의 사업 모델 및 핵심 기술에 대하여 간단한 정리하고, 핵심 기술의 발전 사항들에 대하여 좀 더 구체적으로 살펴볼 것이다. 특히 Rocketlab 사가 개발 중인 저가 고성능 경량 우주발사체 Electron 에 사용될 예정인 전기펌프 사이클 엔진에 대하여 좀 더 구체적으로 살펴보고, 이들이 로켓 과학자들에게 주는 시사점에 대하여 살펴볼 것이다.

산업배열회수용 1MW급 유기랭킨 사이클 시스템 개발 (Development of 1MW Organic Rankine Cycle System for Industrial Waste Heat Recovery Put English Title Here)

  • 조한창;박흥수;이용국
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.776-781
    • /
    • 2001
  • To enhance thermal efficiency of thermal facility through recovery of low and medium temperature waste heat, 1MW organic Rankine cycle system was designed and developed. The exhaust gases of $175^{\circ}C$ at two 100MW power plants in pohang steel works were selected as the representative of low and medium temperature waste heat in industrial process for the heat source of the organic Rankine cycle system. HCFC-123, a kind of harmless refrigerant, was chosen as the working fluid for Rankine cycle. The organic Rankine cycle system with selected exhaust gases and working fluid was designed and constructed. From the operation, it was confirmed that the organic Rankine cycle system is available for low and medium temperature waste heat recovery in industrial process. The optimum operating manuals, such as heat-up of hot water, turbine start-up, and the process of electric power generation, were derived. However, electric power generated was not 1MW as designed but only 670kW. It is due to deficiency of pump capacity for supply of HCFC-123. So it is necessary to increase the pump capacity or to decrease the pressure loss in pipe for more improved HCFC-123 supply.

  • PDF

복합열원형 히트펌프 냉난방 시스템의 성능분석에 관한 연구 (A study for a Performance analysis of Hybrid heat pump Air conditioning system)

  • 임현묵;박희문;조수;성욱주;박진훈;박태진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1373-1378
    • /
    • 2009
  • This study is aiming comparison and analization between efficiency of hybride air conditioning system which uses low temperature water under dam and air and EHP(Electric Heat Pump). The experimental was carried out with air cooling tests for EHP system having 80HP and composition heat pump system. P-i diagram of both systems and COP was used to derive schemetic and calcuations. As results of the tests, hybride system has 1.4 time higher efficiency coefficient.

  • PDF

전기히터식 및 히트펌프식 식품 건조기의 에너지 성능 비교 (Energy Performance Analysis of Electric Heater and Heat Pump Food Dryers)

  • 유영우;김영일;박승태
    • 한국지열·수열에너지학회논문집
    • /
    • 제11권4호
    • /
    • pp.1-6
    • /
    • 2015
  • In this study, energy performance of two types of food dryers which are electric heater and heat pump is studied experimentally. With drying chamber temperatures controlled at 45, 50 and $55^{\circ}C$, sliced radish is dried from an initial mass of 90 to final 7 kg. Moisture content, drying time, total power consumption, MER (moisture extraction rate, kg/h) and SMER (specific moisture extraction rate, kg/kWh) are measured and analyzed. As the drying chamber temperature is increased, drying time is shortened but energy efficiency is reduced for both types. For an electric heater dryer, the effect of chamber temperature on drying time is significant but less significant on energy efficiency. For a heat pump dryer, the dependence of chamber temperature on drying time is weak but strong on energy efficiency. Temperature levels have little effect on electric heater dryer performance but strong effect on heat pump dryer which operates on a vapor compression refrigeration cycle. The energy performance of the heat pump dryer is superior with an average SMER of 2.175 kg/kWh which is 2.22 times greater than that of the electric heater dryer with SMER of 1.224 kg/kWh.

교육 시설에서의 히트 펌프 냉난방 시스템 실사용을 통한 경제성 분석 (Economic Analysis of Heat Pump System through Actual Operation)

  • 김길태;정성일;주호영;안영철;이재근
    • 설비공학논문집
    • /
    • 제19권6호
    • /
    • pp.470-475
    • /
    • 2007
  • The present study has been conducted economic analysis through actual operation of electric heat pump (EHP) and gas engine driven heat pump (GHP) which are installed at the same building in the university. Cost items, such as initial cost, annual energy cost and maintenance cost of each system are considered to analyze life cycle cost (LCC) and economical efficiencies are compared. The initial cost is considered on the basis of actual cost, and annual energy cost is converted into the cost after measuring electricity and gas consumption a day LCC applied present value method is used to assess economical profit of both of them. Variables used to LCC analysis are electricity cost escalation rate, natural gas cost escalation rate, interest rate, and service lives when each of them are 4%, 2%, 8%, and 20 years. The result shows that EHP (148,257,306 won) is more profitable than GHP (161,239,296 won) by 8.05% (12,981,990 won).

하이브리드 제습냉방시스템의 성능평가 연구 (A Study on the Performance Evaluation of a Hybrid Desiccant Cooling System)

  • 황원백;김용찬;이대영
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.121-128
    • /
    • 2012
  • Improvement in the energy efficiency has been studied of the desiccant cooling system by applying a vapor compression type heat pump to modify the system into a hybrid system. The cycle simulation was performed and the results were compared between a reference desiccant cooling system composed of a desiccant rotor, a sensible rotor and a regenerative evaporative cooler, and a hybrid desiccant cooling system with the sensible rotor being replaced by a heat pump. Though the electric consumption increases as much as the compressor power consumption, the total cooling capacity increases and the thermal energy input decreases by the addition of the heat pump. Therefore, the total energy efficiency can be improved if the increase in the electric consumption can be compensated with the increase in the cooling capacity and the decrease in the thermal energy input. The results showed that the total energy efficiency is optimized at a certain heat pump capacity. When the heat from the CHP plant is used for the thermal energy input, the energy consumption of the hybrid system is reduced by 20~30% compared with the reference system when the heat pump shares 30~40% of the total cooling capacity.

1 MW급 유기랭킨 사이클 시스템 개발 (Development of 1MW Organic Rankine Cycle System)

  • 박흥수;조한창;이용국
    • 에너지공학
    • /
    • 제10권4호
    • /
    • pp.318-326
    • /
    • 2001
  • 중저온 배열회수를 통해 열설비의 열효율을 향상시키기 위하여 1 MW급 유기랭킨사이클시스템을 설계, 개발하였다. 포항제철소에 있는 두 대의 100 MW급 기력발전소에서 발생하는 175$^{\circ}C$의 배가스를 산업체에서 발생하는 대표적인 중저온배열원으로 선정하고, 환경오염을 최소화할 수 있는 신냉매인 HCFC-123을 시스템의 작동유체로 선정하였다. 유기냉킨사이클시스템의 시험운전을 통하여 유기랭킨사이클시스템이 산업체의 중저온배열을 회수하는데 유용함을 확인하였다. 열수의 가열, 터빈기동 및 전기투입방법 등의 운전방법을 최적화하였다. 그러나 HCFC-123 공급펌프의 능력부족으로 작동유체의 공급이 부족하여 정격출력보다 낮은 670kW의 전력을 생산할 수 있었다. HCFC-123의 공급유량을 증가시키기 위하여 파이프의 압력손실저하 및 펌프의 성능 향상을 위한 펌프교체 등이 고려되어야 함을 알 수 있었다.

  • PDF