• 제목/요약/키워드: Electric-Shock

검색결과 407건 처리시간 0.027초

Integrated Management System to Improve Photovoltaic Operation Efficiency (태양광발전 운영효율 향상을 위한 통합관리시스템)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • 제19권4호
    • /
    • pp.113-118
    • /
    • 2019
  • A solar power plant is a facility that produces electricity. As the risk of fire and electric shock accidents is diversified, the risk of workers, surrounding people, and facilities is increased, preventing safety accidents and promptly responding to safety accidents Is emerging. In light of the necessity of such development, it is necessary to develop a solar power generation management system that can diagnose and maintain the problems of the power generation system in real time by developing technologies for collecting and analyzing the data produced by the solar power generation system As a result, the utilization rate and the maintenance cost can be reduced. In order to do this, it is necessary to accurately predict the solar power generation amount in the present state, to diagnose the abnormality of the current power generation state and to grasp the abnormal position, and to use the model considering economical efficiency when the abnormal position is grasped, And the time and other information should be provided.

Dynamic Time Constant Based High-Performance Insulation Resistance Calculation Method (동적 시정수 기반 고성능 절연 저항 계산 기법)

  • Son, Gi-Beom;Hong, Jong-Phil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제24권8호
    • /
    • pp.1058-1063
    • /
    • 2020
  • This paper presents a new insulation resistance calculation technique to prevent electric shock and fire accidents due to the dielectric breakdown in the primary insulation section of the IT ground system. The solar power generation market is growing rapidly due to the recent expansion of renewable energy and energy storage systems, but as the insulation is destroyed and fire accidents frequently occur, a device for monitoring the insulation resistance state is indispensable to the IT grounding method. Compared to the conventional algorithm that use a method of multiplying a time constant to a fixed coefficient, the proposed insulation resistance calculation method has a fast response time and high accuracy over a wide insulation resistance range by applying a different coefficient according to the values of the insulation impedance. The proposed dynamic time constant based insulation resistance calculation technique reduces the response time by up to 39.29 seconds and improves the error rate by 20.11%, compared to the conventional method.

Atypical triggers in trigeminal neuralgia: the role of A-delta sensory afferents in food and weather triggers

  • Koh, Wenjun;Lim, Huili;Chen, Xuanxuan
    • The Korean Journal of Pain
    • /
    • 제34권1호
    • /
    • pp.66-71
    • /
    • 2021
  • Background: Trigeminal neuralgia is a debilitating craniofacial pain syndrome that is characterized by paroxysms of intense, short-lived electric shock-like pains in the trigeminal nerve distribution. Recently, the presence of triggers has become one of the key diagnostic criteria in the 3rd edition of the International Classification of Headache Disorders. Light touch is the most common trigger, however other non-mechanical triggers, such as cold weather and certain foods, have been thought to provoke trigeminal neuralgia anecdotally. We aimed to characterize the prevalence and characteristics of these atypical triggers. Methods: We conducted a retrospective, cross-sectional study of atypical triggers in trigeminal neuralgia patients seen in a tertiary pain clinic in Singapore. Patients were recruited via clinic records, and study data were identified from physician documentation. Results: A total of 60 patients met the inclusion criteria. Weather triggers were observed in 12 patients (20%), of which five patients (8%) reported strong winds, 4 patients (7%) reported cold temperatures, and 3 patients (5%) reported cold winds as triggers. Fifteen patients (25%) had a specific food trigger, of which 10 patients (17%) reported hard or tough food, 5 patients (8%) reported hot/cold food, 4 patients (7%) reported spicy food, and 2 patients (3%) reported sweet food as triggers. Conclusions: Although trigeminal neuralgia is most commonly triggered by mechanical stimuli, atypical triggers such as cold temperatures and certain foods are seen in a significant proportion of patients. These atypical triggers may share a common pathway of sensory afferent Aδ fiber activation.

Ag Sintering Die Attach Technology for Wide-bandgap Power Semiconductor Packaging (Wide-bandgap 전력반도체 패키징을 위한 Ag 소결 다이접합 기술)

  • Min-Su Kim;Dongjin Kim
    • Journal of the Microelectronics and Packaging Society
    • /
    • 제30권1호
    • /
    • pp.1-16
    • /
    • 2023
  • Recently, the shift to next-generation wide-bandgap (WBG) power semiconductor for electric vehicle is accelerated due to the need to improve power conversion efficiency and to overcome the limitation of conventional Si power semiconductor. With the adoption of WBG semiconductor, it is also required that the packaging materials for power modules have high temperature durability. As an alternative to conventional high-temperature Pb-based solder, Ag sintering die attach, which is one of the power module packaging process, is receiving attention. In this study, we will introduce the recent research trends on the Ag sintering die attach process. The effects of sintering parameters on the bonding properties and methodology on the exact physical properties of Ag sintered layer by the realization 3D image are discussed. In addition, trends in thermal shock and power cycle reliability test results for power module are discussed.

Development of overhead distribution line diagnosis system program (가공 배전선로 진단시스템 프로그램 개발)

  • Dong Hyun Chung;Deok Jin Lee
    • Smart Media Journal
    • /
    • 제12권5호
    • /
    • pp.81-87
    • /
    • 2023
  • In this paper, accidents in high-voltage overhead distribution lines, which provide stable power supply in the power system, cause inconvenience in life and disruption of production of companies. 22.9 [kV] high-voltage overhead power distribution lines aim to improve reliability and stability, such as damage caused by rain, snow, wind, etc., or electric shock prevention. Therefore, in order to prevent wire disconnection accidents due to deterioration of electrical conductivity or tensile strength due to corrosion of overhead distribution lines, it is necessary to prevent unexpected accidents in the future through regular inspection and repair. In order to diagnose deterioration due to corrosion of distribution lines, a diagnostic system (measuring instrument) is installed on the wires to monitor the condition of the wires. The manager on the ground receives the measured data through ZigBee wireless communication, controls the diagnosis system through the diagnosis system program, and grasps the condition of the overhead distribution line through the measured data and photographed photos, and predicts the life of the wire along with the visual inspection method. developed a program.

A Study on the Effectiveness of Virtual and Real Experience Type Safety Education at Construction Sites (건설현장에 접목한 가상체험·실물체험 안전교육의 효과성 연구)

  • Cho Choonhwan
    • Journal of the Korea Institute of Construction Safety
    • /
    • 제6권1호
    • /
    • pp.1-6
    • /
    • 2024
  • Existing safety education delivered to construction workers has limitations in concentration and immersion, so delivery power and interest are low. In order to improve the unstable behavior of construction workers and prevent safety accidents through education, a paradigm shift to hands-on education is necessary. Experiential safety education aims to contribute to the prevention of safety accidents and induce safe behavior by construction workers to recognize risks faster, select safe working methods suitable for the working environment, and improve emergency response and proactive response. Experiential education facilities have a follow-up learning effect in case of danger. The experience facility, which consists of the same working environment as the actual construction site, is designed to experience falls, equipment contraction, fire, and electric shock. In order to achieve the results of safety education that has invested a lot of time, construction workers must have motivation to participate, and "experiential safety education" through playful, deviant, and aesthetic experiences reduces serious accidents.

A Study on the Safety Characterization Grounding Design of the Inner Photovoltaic System (태양광 발전단지 내부 그리드의 안전 특성화 접지 설계에 관한 연구)

  • Kim, Hong-Yong;Yoon, Suk-Ho
    • Journal of the Society of Disaster Information
    • /
    • 제14권2호
    • /
    • pp.130-140
    • /
    • 2018
  • Purpose: In this paper, we propose a design technique for the safety characterization grounding in the construction of the photovoltaic power generation complex which can be useful and useful as an alternative power energy source in our society. In other words, we will introduce the application of safety grounding for each application, which can improve and optimize the reliability of the internal grid from the cell module to the electric room in the photovoltaic power generation complex. Method: We analyze the earth resistivity of the soil in the solar power plant and use the computer program (CDEGS) to analyze the contact voltage and stratospheric voltage causing the electric shock, and propose the calculation and calculation method of the safety ground. In addition, we will discuss the importance of semi-permanent ground electrode selection in consideration of soil environment. Results: We could obtain the maximum and minimum value of ground resistivity for each of the three areas of the data measured by the Wenner 4 - electrode method. The measured data was substituted into the basic equation and calculated with a MATLAB computer program. That is, it can be determined that the thickness of the minimum resistance value is the most favorable soil environment for installing the ground electrode. Conclusion: Through this study, we propose a grounding system design method that can suppress the potential rise on the ground surface in the inner grid of solar power plant according to each case. However, the development of smart devices capable of accumulating big data and a monitoring system capable of real-time monitoring of seismic changes in earth resistances and grounding systems should be further studied.

A Case Study of Risk Assessments and Safety Measures in a PCB Manufacturing Process (인쇄회로기판 제조 공정에서 위험성평가와 안전조치 적용 사례 연구)

  • Lee, Young Man;Lee, Inseok
    • Journal of the Korean Society of Safety
    • /
    • 제37권4호
    • /
    • pp.120-128
    • /
    • 2022
  • Printed circuit boards (PCBs) are a basic component in the electronics industry and are widely used in nearly all electronic products, such as mobile phones, tablet computers, and digital cameras, as well as in electric equipment. PCB manufacturing involves the use of many chemicals and chemical processes and therefore has more risks than other manufacturing sectors. This study aims to identify the causes of possible accidents during PCB manufacturing through risk assessment, develop and implement safety measures, and evaluate the effectiveness of these measures. Note that the safety measures developed to mitigate the risks of a certain process were also implemented for other similar processes. The risk assessments conducted over seven years, from 2015 to 2021, at a PCB manufacturing company identified 361 hazardous processes. Between 2016 and 2019, 41-56 hazardous processes were identified per year; such processes decreased to fewer than 20 per year after 2020. Application of the risk assessment results to the improvement of the hazardous processes with the similar characteristics seems to be effective in decreasing the risks. Equipment-related factors such as lack of appropriate maintenance, low work standards, and defective protection devices were responsible for 59.8% of all possible accidents. Because PCB manufacturing involves many chemicals, skin contact with hazardous substances, electric shock, fire, and explosion were the most common types of possible accidents (81.7%). In total, 505 safety measures were implemented, including 157 related to purchase and improvement of equipment and devices for safety (31.1%), 147 related to the installation/modification of fire prevention facilities (29.1%), and 69 related to the use of standard electrical appliances (13.7%). Risk assessment conducted after implementing the safety measures showed that these measures significantly decreased risk; 247 processes (68.4%) had a risk level of 3, corresponding to "very low," and 114 processes (31.6%) showed a risk level of 4, corresponding to "low." In particular, risk assessment of 104 processes with risk scores of 12 and 10 other processes with risk score of 16 showed that the risk decreased to 4 after implementing the safety measures. Thus, implementing these measures in similar manufacturing sectors that involve chemical processes can mitigate risk.

A Study on the Characteristics Assessment and Fabrication of Distribution Board according to KEMC Standards (KEMC 규정에 의한 분전반의 제작 및 특성 평가에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • 제31권3호
    • /
    • pp.63-72
    • /
    • 2017
  • This study fabricated a low-voltage 10 circuit distribution board based on the KEMC (Korea Electrical Manufacturers Cooperative) 2102-610 standard and performed a characteristics assessment of the developed 10 circuit distribution board to secure product stability. The developed 10 circuit distribution board is designed to have the characteristics of insulation materials, as well as resistance to corrosion ultraviolet radiation and mechanical impact. The developed distribution board is fabricated to have an appropriate protection class of enclosure, electric shock prevention and protection circuits, switchgear and its components, internal electrical circuits and connectors, external conduct terminal, insulation characteristics, temperature rise test, heat resistance, etc. The developed 10 circuit distribution board consists of a single phase circuit and 3-phase circuits. It is possible to measure in real time the leakage current generated from the load distribution line by installing a sensor module at the load side of each of the branched switchgears. In addition, it is possible to increase a circuit according to the use and purpose of the load and to also manage and check the load in real time. Temperature rise tests were performed on the developed 10 circuit distribution board at 18 places including the inlet connection, main circuit and distribution circuit bus bars and bus bar supports, etc. The highest temperature of $65.3^{\circ}C$ was measured at the R-Phase of the connection of the MCCB power supply for the branch circuit bus bar and a temperature rise of $61.6^{\circ}C$ was measured at the T-Phase of the load side. When applying thermal stress to an MCCB for 6 hours at $180^{\circ}C$ using a heat resistant experimental device, it was found that the actuator lever was transformed and moved in the tripped state.

Positive Expression of EGFP Gene in Bovine Embryos after ICSI using Spermatozoa Co-cultured with Exogenous DNA (외래 유전자와 공배양한 정자를 이용해 난자내 직접 주입술한 후 EGFP의 발현)

  • 윤효진;이훈택;정길생
    • Korean Journal of Animal Reproduction
    • /
    • 제26권3호
    • /
    • pp.205-214
    • /
    • 2002
  • There are many methods to introduce exogenous DNA into embryo to produce transgenic animals. Exogenous gene can be integrated into oocyte by sperm vector. In this study, sperm was used as a vector for a transgene, which is encoding enhanced green fluorescent protein (EGFP). The objective of this study was to investigate the expression of exogenous gene in bovine embryos after injection of spermatozoa cocultured with EGFP DNA fragment. Spermatozoa were plunged into liquid nitrogen and thawed several times or shook in 0.2% Triton X-100 to remove sperm membrane followed by DTT treatment. The injected oocytes were co-cultured with vero cells in CR1aa, and expression of EGFP gene was observed under fluorescent microscope. Blastocyst formation rates of oocytes injected with sperm treated with DTT, DTT-freezing or DTT-Triton X-100 were 34.7, 39.4 and 31.9%, respectively. The rates of EGFP expression in oocytes injected with 54 ng DNA after DTT-treated, DTT-freezing and DTT-Triton X-100-treated sperm were 0, 19.1 and 13.9%. On the other hands, expression rate of oocytes injected with sperm cocultured with 13.5, 27 and 63.5 ng of EFGP DNA were 6.7, 9.0 and 5.1%, respectively. When intact sperm was mixed with 63.5 ng/${mu}ell$ EGFP DNA fragment, and then electroporated before injection, the expression rate of injected oocyte was 2%. Unexpectedly, electro-poration could not increase the expression rate. These results suggest that sperm can be used as a transgene vector, even if the efficiency was low (19.1%).