• Title/Summary/Keyword: Electric-Shock

Search Result 407, Processing Time 0.03 seconds

Estimation of CO2 Emission and Emission Cost Function of Thermal Power Plants and Application to 5-Bus Sample Power System (화력발전소의 CO2 배출량 및 배출비용 함수산정과 5모선 전력계통 적용사례)

  • Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.13-18
    • /
    • 2008
  • The global warming due to greenhouse gases is now the hottest issue all over the world. The world has been under $CO_2$ war since the Kyoto Protocol was opened for signature on December 11, 1997 in Kyoto, Japan. The Kyoto Protocol now covers more than 164 countries globally as of July 2006. Countries that ratify this protocol commit to reduce their $CO_2$ emissions, or engage in emissions trading. Korea is also expected to obey the Protocol starting in 2013, which will give a serious shock especially to the electric power industry. The power plants burning the fossil fuel produce more than 20 percent of national total $CO_2$ emission. This paper resents the calculation of the amount and cost of $CO_2$ emission w.r.t. generator MW output and its application to power system operation. The $CO_2$ emission function is derived using the input-output coefficients of the thermal power plants. The optimal power system operation considering $CO_2$ emission and its cost is demonstrated on a five-bus sample power system.

General Pharmacological Study of CJ-11828, an Amlodipine adipate

  • Choi, Jae-Mook;Lee, Sung-Hak;Kim, Il-Hwan;Park, Jie-Eun;Park, Choong-Sil;Youn, Yong-Sik;Lim, Dong-Kwon;Cho, Sung-Hwan;Chang, Jun-Hwan;Do, Sun-Hee;Kim, Eun-Joo;Kim, Young-Hoon
    • Biomolecules & Therapeutics
    • /
    • v.12 no.2
    • /
    • pp.114-121
    • /
    • 2004
  • This study was undertaken to evaluate the general pharmacological properties of CJ-11828, an amlodipine adipate, in experimental animals and in vitro system. CJ-11828 had no effects on general behavior, motor coordination, writhing syndromes, pentetrazol-induced chemoshock and electric shock in mice at dose levels of 3,10, anti 30 mg/kg, po. But there were decrease of body temperature, prolongation of sleeping time, and inhibition of intestinal activity in mice treated with CJ-11828 at doses of 10 and 30 mg/kg, po. CJ-11828 decreased the blood pressure in coscuous fog at the dose level of 2mg/kg, po, but it was expected as a result of pharmacological activity of CJ-11828. Any effect on respiratory system was not observed in conscious rat at doses of 3,10, and 30 mg/kg, po. The slight decrease in spontaneous motor activity was observed in mice treated with CJ-11828 at high dose, 30 mg/kg. In vitro experiments, CJ-11828 had no effect on agonists-induced contraction of isolated guinea pig ileum at 0.1, 1, and 10 ${\mu}$M. Based on these results, it was concluded that CJ-11828 had no pharmacological effect ill these studies even up to the 36-fold anticipated clinical dose, 3 mg/kg.

Development of Load Cell Using Fiber Brags Grating Sensors and Differential Method for Structural Health Monitoring (구조 건전성 모니터링을 위한 광섬유 브래그 격자 센서와 차동법을 적용한 로드셀 개발)

  • Kim, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.299-307
    • /
    • 2009
  • Emerging fiber optic sensor technologies have shown great potential to overcome the difficulties associated with conventional sensors. Fiber optic sensors are immune to EM noise and electric shock and thus can be used in explosion-prone areas. Several kinds of fiber optic sensors have been developed over the last two decades to take advantage of these merits. There have also been many field applications of fiber optic sensors for structural health monitoring as NDT/HDE. However, very few sensors, particularly a load cell have been successfully commercialized. This Paper Presents a load cell using fiber Bra99 gra1ing (FBG) sensors. The shape of the load cell is a link type, and three FBG sensors are used for measuring strains at three different points. Especially, these strains are processed with a differential method in order to exclude common mode noise such as temperature. Moreover, the sensitivity, the linearity and the resolution of the load cell were successfully verified from the experiment of tension test.

3DImmersion Type Virtual Environment System : Training Interruption-free Live-Line Workers (무정전 활선작업 피교육자를 위한 3차원 몰입형 가상환경 교육시스템의 개발)

  • 정영범;박창현;김기현;장길수
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.1
    • /
    • pp.22-30
    • /
    • 2004
  • As an information-oriented society comes, many people use PC and depend on database that network server has. However, the online data can be missed when a blackout happens and also a power failure effects on standard of judgment on Power Quality. Thus, it is reason of a trend using interruption-free live-line work when a trouble happens to power system. However, the 83% among the number of people who receive an electric shock experience when a laborer is doing interruption-free live-line works. In interruption-free method, the education and the training problem has been issued. However, we have a few instructors for that training. Furthermore, the trainees have short training period, just 4 weeks. In this paper, to develope the method that has no restriction of a time and place and reduce the wasteful materials, immersion type virtual reality(or environment) technology is used. The users of a 3D immersion type VR training system can interact with the system by doing same action in the real safe environment. Thus, it can be valuable to apply this training system to a dangerous work like as "Interruption-free live-line work exchanging COS(Cut-Out-Switch)". In this program, the user works with a instruction on the window and speaker and can't work other tasks until each part of the task completed. The workers using this system can use their hands and viewpoint movement as he is in a real environment but the trainee can't use all parts and senses of a real body with the current VR technology. Despite of this weak point, when we consider the trends of improvement in electrical devices and communication technology, we can say that 3D graphic VR application has a high potentiality.

The Effect of N-Substituted Alkyl Groups on the Anticonvulsant Activities of N-Cbz-${\alpha}$-amino-N-alkylsuccinimides

  • Lee, Jae-Won;Son, Ki-Chun;Jung, Kyung-Im;Choi, Jong-Won;Park, Min-Soo
    • Archives of Pharmacal Research
    • /
    • v.20 no.1
    • /
    • pp.53-57
    • /
    • 1997
  • For the purpose of defining the effects of the N-substituted alkyl groups on the anticonvulsant activities of N-Cbz-.alpha.-aminosuccinimides, various (R)- and (S)-N-alkyl substituted N-Cbz-.alpha.-aminosuccinimides (1 and 2) were prepared from the corresponding (R)- and (S)-N-Cbz-aspartic acid by using known reaction and were evaluated the anticonvulsant activies in the MES and PTZ tests, including their neurotoxicities. The most active compound in the MES test was (R)N-Cbz-.alpha.-amino-N-methylsuccinimide (1b) $(ED_{50}=52.5 mg/kg, Pl=3.2)$. And in case of the PTZ test, (R)-N-Cbz-.alpha.-amino-N-ethylsuccinimide (1c) was the most active compound $(ED_{50}/=32.5mg/kg, Pl=3.1)$. The order of anticonvulsant activities of these compounds against the MES test, as judged from the ED_50values for the R series (1), was N-methyl > N-isobutyl > non-substituted > N-ethyl, N-allyl > N-benzyl compound; for the S series (2) N-methyl > N-altyl > non-substituted > N-isobutyl > N-ethyl > N-benzyl compound. The anticonvulsant activities in the PTZ tests of these compounds exhibited somewhat different pattern ; for the R series (1) Nethyl > N-methyl > N-isobutyl> non-substituted > N-allyl > N-benzyl compound in order of decreasing activity; for S series (2) N-ethyl > N-allyl, non-substituted > N-isobutyl > N-methyl > N-benzyl compound in order of decreasing activity.

  • PDF

Hearing Ability of Bambooleaf wrasse Pseudolabrus japonicus caught in the coast of Jeju (제주 연안에서 어획된 황놀래기의 청각 능력)

  • Choi, Chan-Moon;Park, Yong-Seok;Lee, Chang-Heon
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.25 no.6
    • /
    • pp.1381-1388
    • /
    • 2013
  • In order to improve the availability of underwater sound by the fundamental data on the hearing ability, the auditory thresholds for the bambooleaf wrasse pseudolabrus japonicus were determined at 80Hz, 100Hz, 200Hz, 300Hz, 500Hz and 800Hz by heartbeat conditioning method using pure tones coupled with a delayed electric shock. The audible range of the bambooleaf wrasse extended from 80Hz to 800Hz with the best sensitivity around 100Hz and 200Hz. In addition, the auditory thresholds over 300Hz increased rapidly. The mean auditory thresholds of the bambooleaf wrasse at the test frequencies, 80Hz, 100Hz, 200Hz, 300Hz, 500Hz and 800Hz were 100dB, 95.1dB, 94.8dB, 109dB, 121dB and 125dB, respectively. Auditory critical ratios for the bambooleaf wrasse were measured using masking stimuli with the spectrum level range of about 70, 74, 78dB (0dB re $1{\mu}Pa/\sqrt{Hz}$). According to white noise level, the auditory thresholds increased as compared with thresholds in a quiet background noise. The Auditory masking by the white noise spectrum level was stared over about 60dB within 80~300Hz. Critical ratios to be measured at frequencies from 80Hz to 300Hz were minimum 33dB and maximum 39dB.

The length of hospital stay of the industrial workers with back injury (산업재해 요통근로자의 재원기간에 관한 연구)

  • Lee, Bok-im
    • Korean Journal of Occupational Health Nursing
    • /
    • v.9 no.1
    • /
    • pp.18-29
    • /
    • 2000
  • Back injury is frequent in industry workers and is a common cause of productivity loss. It has been reported that the insured of industrial accident insurance tend to stay in hospital longer than that of other types of insurance. The purpose of this study was to identify factors affecting the length of hospital stay for the treatment of back injury in the workers under industrial accident insurance. The results of this study help insurers develop reasonable industrial accident insurance policy for back injury claims and prevention strategies of work-related back injury. A total of 2,949 patients whose industrial accident insurance claim has been approved for the treatment of work-related back injury from January to December 1999 were included in this study. Relationship between the length of hospital stay and characteristics of patient, work place, back injury, and hospital were assessed using ANOVA, t-test, simple linear regression and multiple resgression. The major findings of this study are as follows : 1. The average length of hospital stay(LOS) was 91.82 days, respectively. 2. Characteristics of Patient LOS of male patients was longer than that of female patients, there was positive correlation between age and LOS and between average wage and LOS. Working period was negatively correlated with LOS. Distance from resident to hospital was positively correlated with LOS and LOS was significantly different dependign on type of duty. 3. Characteristics of Work Place LOS was significantly different depending on types of industry and geographical region of work place. Size of work place was positively correlated with LOS. 4. Characteristics of Back Injury Occupational back pain required shorter LOS compared with back injury due to electric shock. Number of concomitant illnesses and severity of disability were positively correlated with LOS. 5. Characteristics of Hospital Patients treated in community hospitals required significantly longer LOS. Treatment in hospitals with rehabilitation program required decreased LOS. This was more prominent as number of physicians specialized in rehabilitation. 6. Multiple regression analysis revealed that distance form resident to hospital, geographical region of work place, size of work place, number of concomitant illnesses, severity of disability, and type of hospital were factors affecting LOS.

  • PDF

A Study on the Development of the Digital Traffic Signal Controller (디지털 교통신호제어기 개발 연구)

  • Ko, Sejin;Lee, Jaekwan;Park, Sangmin;Gho, Gwang-Yong;Yun, Ilsoo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.6
    • /
    • pp.43-59
    • /
    • 2019
  • The Traffic controller currently used in Korea is a switch control system that directly transfers 220V of high voltage to traffic lights one to one. This method requires a lot of cables, and there are concerns about electric shock. Accordingly, Korea Road Traffic Authority added the digital communication signal controller standard using digital communication method to the standard specification of the communication signal controller of the National Police Agency. Based on these specifications, this paper intended to develop digital communication call controllers. In addition, it was verified that even if the digital communication signal controller and analogue communication call controller were mixed, they could operate in the signal control system currently in operation.

Implementation of ELB Leakage Current Control System based on ZigBee Communication (ZigBee통신 기반 ELB 누전전류 제어시스템 구현)

  • Ju, Jae-Han
    • 전자공학회논문지 IE
    • /
    • v.49 no.2
    • /
    • pp.52-57
    • /
    • 2012
  • Social development as well as the development of consumer electronic devices due to leakage, electric shock or fire, and many are exposed to the risk of leakage currents. Premises in the control cabinet, but the circuit breaker is installed, the existing circuit breaker shuts off when a short circuit in the control cabinet, installed only have the capability. Also connected to the outlet is installed byeokmada family of devices is not easy thing to check individually. In this paper, circuit breakers and circuit analysis and circuit performance, ZigBee-based premises of consumer electronics devices using sensors to monitor the health of the leakage can be presented on how. Performance analysis, the proposed ELB leakage current control system is built into the appliance leakage circuit breaker for each household appliances because the application can check the status of a short circuit, short circuit, over the existing system can be monitored easily.

Solar CO2-Reforming of Methane Using a Double-Layer Absorber (더블 레이어 흡수기를 이용한 고온 태양열 메탄-이산화탄소 개질반응)

  • Kim, Dong-Yeon;Lee, Jin-Gyu;Lee, Ju-Han;Seo, Tae-Beom
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.267-273
    • /
    • 2012
  • Solar reforming of methane with CO2 was successfully tested with a direct irradiated absorber on a parabolic dish capable of 5kWth solar power. And the new type of double-layer absorber-the front layer, porous metal foam which absorbs the radiation and transfers the heat from material to gas, and the back layer, catalytically-activated metal foam-was prepared, and its activity was tested by using electric furnace. Ni was applied as the active metal on the gamma-Al2O3 coated Ni metal foam for the preparation of the catalytically-activated metal foam layer. Compared to conventional direct irradiation of the catalytically activated metal foam absorber, this new type of double layer absorber is found to exhibit a superior reaction and thermal storage performance at the fluctuating incident solar radiation. In addition, unlike direct irradiation of the foam absorber, double layer absorber has better thermal resistance, which prevents the emergence of cracks caused by mechanical or thermal shock. The total solar power absorbed reached up to 3.25kW and the maximum CH4 conversion was almost 59%.

  • PDF