• 제목/요약/키워드: Electric utility

검색결과 338건 처리시간 0.034초

배전용 접지전극 안전성 분석을 위한 국제기준 검토 (Analysis of the International Safety Criteria of IEEE Std 80 and IEC 479-1)

  • 강문호;박재덕;이흥호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.214-217
    • /
    • 2005
  • To improve the safety of facilities and human beings when the ground fault occurs, public power utility prescribes the reasonable ground resistances, measures and controls the ground resistance of all the ground electrodes biennially. Concerning the safety of human, there are two safety criteria widely accepted, i.e. the IEEE Std 80-2000 and the IEC 479-1:1994. The IEEE Std 80-2000 is based on a simplified electric shock model usually translated into permissible touch and step voltages. The IEC 479-1:1994 is less specific than IEEE Std 80-2000 for analysis purpose. The IEC 479-1:1994 provides values of permissible body current against electric shock duration. This paper provides a technical study of these two standards to analyze the safety of human beings of ground electrodes developed recently for distribution power system.

  • PDF

서로다른 발전방식으로 운전되는 산업용 열병합발전시스템의 최적운전계획 수립 (Operation Scheduling of Industrial Cogeneration System with Each other Generation Mode)

  • 정지훈;이종범;오성근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.354-356
    • /
    • 2000
  • This paper describes the strategy of a daily optimal operational scheduling on cogeneration systems with each other generation mode. The cogeneration systems consists of three generators. auxiiiary devices which are three auxiliary boilers, two waste boilers and three sludge incinerators. One unit that using the back pressure turbin generates the electrical and the thermal energy. The other two units that using the extraction condensing turbine generate the energy. Auxiliary devices operate to supplement the thermal energy to the thermal load with three units. The cogeneration system has a large capacity which is able to supply enough the thermal energy to the thermal load, however the electric power generated is insufficient to satisfy the electrical load. Therefore the insufficient electric energy is supplemented by buying electrical energy from the utility. Simulation was carried out using optimization toolbox. The result reveals that the proposed modeling and strategy can be effectively applied to cogeneration systems with each other generation mode.

  • PDF

전력거래에서 최적조류계산을 수행하는 Web 프로그램 개발 (Development of Web Program for the Calculation of OPF and Congestion Cost)

  • 정재옥;문준모;이광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.10-12
    • /
    • 2000
  • The electric utility industry around the world is undergoing a revolutionary transition from vertically integrated monopoly structure to a competitive industry. Electric market price changes hourly because suppliers and customers participate in a open market competitively. In this paper a web program developed wi function of OPF calculation. This program is re by a perl language. Also We calculated the marginal cost and the congestion charge shadow price resulted from the OPF.

  • PDF

전력산업용 위성통신망 구축 (The Construction of the Satellite communication network for Power Industry)

  • 김수배;오규환;정광균;이범석;현덕화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.497-499
    • /
    • 2006
  • There are several types of communication method which is used for the supply of electric power stably. But the communication methods used in KEPCO have weak points in the viewpoint of economy, technology and management. The Satellite communication systems have competitive power in price and technology for national wide utility owing to its wide area coverage and stability. This paper presents various adapted examples of the Power industry using he satellite communication systems.

  • PDF

필터 임피던스와 공진주파수를 고려한 계통연계형 인버터의 LCL 필터 최적 설계기법 (Optimized LCL Filter Design Method of Utility Interactive Inverter Considering Filter Impedance and Resonant Frequency)

  • 양석현;권민호;박성열;최세완;이동주;백석민;연인철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 추계학술대회 논문집
    • /
    • pp.27-28
    • /
    • 2014
  • 본 논문에서는 필터 임피던스와 공진주파수를 고려한 계통연계형 인버터의 LCL 필터 설계기법을 제안한다. 일반적으로 계통연계 인버터는 고속 스위칭으로 인한 고조파 전류가 출력단에 포함된다. 이러한 고조파를 감소시키기고 출력을 정현파로 만들기 위해 출력단에 수동필터가 사용된다. 제안하는 필터 설계 기법은 필터 인덕턴스를 최소화 할 수 있다. 따라서 수동필터의 부피를 감소시키고 DC링크 전압 이용률 손실을 최소로 할 수 있다. 제안하는 방법으로 LCL 필터를 설계하고 실험을 통해 설계 방법의 타당성을 검증하였다.

  • PDF

DIRECT COMPUTATION OF MARGINAL OPERATING CONDITIONS FOR VOLTAGE COLLAPSE

  • Lee, Kyung-Jae;Jung, Tay-Ho
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.195-201
    • /
    • 1989
  • Voltage collapse is a serious concern to the electirc utility industry. It is common to associate steady-state stability with the ability of the transmission system to transport real power and to associate voltage collapse with the inability to provide reactive power at the necessary locations within the system. An algorithm to directly calculate the critical point of system voltage collapse was presented by the authors. The method (based on the ordinary power flow equations and explicit requirement of singularity of the Jacobian matrix) is basically one degree of freedom with proper load distribution factors. This paper suggests a modified algorithm to increase the degree of freedom, introducing the nonlinear programming technique. The objective function is a distance measure between the present operating point and the closest voltage collapse point. Knowledge of the distance and the most vulnarable bus from the voltage collapse point of view may be used as a useful index for the secure system operation.

  • PDF

역전파 신경회로망 기반의 단기시장가격 예측 (Locational Marginal Price Forecasting Using Artificial Neural Network)

  • 송병선;이정규;박종배;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.698-700
    • /
    • 2004
  • Electric power restructuring offers a major change to the vertically integrated utility monopoly. Deregulation has had a great impact on the electric power industry in various countries. Bidding competition is one of the main transaction approaches after deregulation. The energy trading levels between market participants is largely dependent on the short-term price forecasts. This paper presents the short-term System Marginal Price (SMP) forecasting implementation using backpropagation Neural Network in competitive electricity market. Demand and SMP that supplied from Korea Power Exchange (KPX) are used by a input data and then predict SMP. It needs to analysis the input data for accurate prediction.

  • PDF

전력거래에서 최적조류계산과 혼잡비용 계산을 수행하는 인터넷 웹 프로그램 개발 (Development of Internet Web Program for the Calculation of OPF and Congestion Cost)

  • 이광호;정재옥
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권6호
    • /
    • pp.259-264
    • /
    • 2001
  • The electric utility industry around the world is undergoing a revolutionary transition from vertically integrated monopoly structures to a competitive structures. Competition in an open transmission access(OTA) makes the market participants access easily the transmission system in a non-discriminatory and equitable manner. The competitions of suppliers and customers make the electric market price change every hour. This paper presents a web program in the internet environment with a function of optimal power flow(OPF) calculation. The Web program gives the nodal marginal cost and the congestion charge using the shadow prices resulted from OPF. This web program is realized by a Perl and JAVA languages, and using the common gateway interface(CGI).

  • PDF

전기설비 사고의 열적 특성 분석 (Analysis of Heat Characteristics for Fault Power Utility)

  • 김기화
    • 한국화재소방학회논문지
    • /
    • 제11권4호
    • /
    • pp.25-31
    • /
    • 1997
  • In this study, EMTP(Electromagnetic Transients Program) which is one of the most well-known computer simulation methods is used to collect the data for a power plant fault. EMTP is the program for an interpretation of the phenomena of electric transients, and is designed to manifest the data of the electric current and voltage etc. at the time of a power plant fault. By EMTP, I analyze the properties of the heat energy which are transferred from the electrics when a power plant fault brings out. In terms of the results of this study, it is able to measure the heat energy at a power plant fault (power transformer) and to be acquired of the related data. And moreover, these data are expected to be used as a standard for the protection of the fire owing to a high voltage power transformer fault.

  • PDF

3kW 계통연계형 태양광발전시스템의 운전특성 (The Operating Characteristics of 3kW Utility Interconnected Photovoltaic System)

  • 김형석;박정민;나종덕;백형래;조금배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.201-204
    • /
    • 2004
  • Consider the optimal design for PV system, it is apply to 3kW interconnected electric power PV system, that is a point of reference for 3kW PV the spread residential section system. Through the driving various practical system, we look into that for efficiency of generation and stability of interconnected system. Using obtained data acquisition, It can be suggest that installation and management for system parameter to optimal design maximum generation electric power. PV system have some losses that are variation radiation, shadow, change temperature, unbalanced grid connection, serial circuit loss, MPP deference loss, PCS loss and so forth. Using obtained various performance characteristic result, we can make database in the future, through the this study, we can get the reliance and have regard to spread PV system.

  • PDF