• Title/Summary/Keyword: Electric stations

Search Result 191, Processing Time 0.033 seconds

ANALYSIS ON THE EVALUATION OF PROJECT EFFICIENCY BASED ON BUDGET EXECUTION: PLANNED OUTAGE MAINTENANCE (POM) FOR ELECTRICITY POWER PLANT

  • Sungkon Moon;Sangwon Han;Myoungwon Kang
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.66-73
    • /
    • 2011
  • With rapid industrialization, electric power consumption has been increasing every year in Korea and in other countries. The provision of additional power stations to produce more electricity is one possible response to this steady increase in consumption. Another alternative is to improve the efficiency of existing stations through timely and effective maintenance works. Since the construction of a new power plant involves a large amount of capital as well as difficulties in the selection of sites, the improvement of existing power stations' efficiencies is often a preferred solution. Therefore, this paper focuses on maintenance project management to address this issue. Among several types of maintenance works, this paper concentrates on planned outage maintenance (POM). This focus arises from the critical impact of POM on other maintenance work, as well as the entire process of electricity production. Unlike other maintenance work, POM is done on the basis of mid and long-term plans. In addition, only POM works are conducted during the outage of all power plants. To evaluate the efficiency of POM works, budget data relating to 164 POM projects between 2001 and 2008 was collected from 7 sites in South Korea. Data envelopment analysis (DEA) was selected as a methodology for evaluation. From this analysis, comparative study was used to determine the categories of projects that had performed well, and those with the most optimized budget structures. Moreover, through discussion with industry, this research develops a feasible proposed method by which to enhance the efficiency of POM projects.

  • PDF

Analysis and measurement of service area of ocean-based DGPS reference station in Korea (국내 해상 DGPS 기준국의 서비스 영역 측정 및 분석)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.6
    • /
    • pp.1255-1261
    • /
    • 2014
  • Based on the radio wave measurement of korean ocean-based DGPS by season, in this paper, the service coverages of ocean-based DGPS reference stations were analyzed according to the climate and season. The signal strengths and signal-to-noise ratios in the land service areas that are provided by ocean-based DGPS reference stations were measured. The ocean-based DGPS reference station except reference stations on the mountainous terrain and the low ground conductivity provide more than 68% service area in comparison with the designed land service coverage providing by the ocean-based DGPS reference stations. To provide the designed service area that is unrelated to a season, it is necessary to install and operate the DGPS reference station with good ground conductivity and high efficiency antenna. Also, the poor service regions which is generated by obstacles of electric wave on pathway can be resolved by the double service area providing by land-based DGPS reference stations.

A Study on Damage Assessment for Fuel Cell Facilities in Gas Stations (주유소 내 연료전지설비에 대한 사고피해예측 연구)

  • Sung Yoon Lim;Jang Choon Lee;Jae Hoon Lee;Seung Ho Choi
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.1
    • /
    • pp.71-80
    • /
    • 2023
  • Fuel cells are low-carbon power sources that can expand distributed energy system and electric vehicle charging infrastructure when installing fuel cells in gas stations. In order to ensure safety for fuel cells in gas stations, quantitative risk assessments were conducted after deriving accident scenarios based on accident data of domestic and foreign gas stations and fuel cells. It calculates the expected extent of damage from fire and explosion that can occur in reality, not the worst accident scenario, and analyzes the damage impact. The separation distance of more than 9.0 m from a dispenser, 15.5 m from a car under refueling, 4.1 m from the ventilation pipe, 1.1 m from the gas adjustment device prevent the severe damage caused by the expected accident. This study result can be used to deploy fuel cells in gas stations and establish safety measures.

Economic Evaluation on a private electric Generation Application in Unelectrified Remote Islands in Korea (미 전화 도서 자가 발전방식 도입에 따른 경제성 검토)

  • Ahn, Kyo-Sang;Lim, Hee-Chun;Eom, Young-Chang
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.14 no.4
    • /
    • pp.348-358
    • /
    • 2003
  • According to Electricity Acceleration Law of Rural Area recently, the needs for replacement of a small scale diesel power generation facility which supplied electricity to 10-50 households Remote Islands has been revealed due to high operating and maintenance cost of Diesel Power Generation. Optimization of electric power system for Small Remote Islands must be made considering the economics, reliability and stability as power sources and estimation of total construction cost of those power stations. For its purpose, an assessment of power generation options such as Photovoltaic, Fuel cell, Wind-hybrid was implemented, economic evaluation of power supply shows the Photovoltaic, Fuel Cell for few household's islands and Diesel, Wind-hybrid for more inhabited islands. Power supplied by Diesel shows the best response to increasing electric demand and system reliability even with its lower economic value. Those who are in charge of power planning have to pay attention to system reliability, stability and operating characteristics of candidate's power supply besides its economics.

A Study of Successful Factor on PSD Application Technique for Manual Operation Mode(ATS) (수동운전(ATS)구간에서 PSD 적용 기술의 성공적 요인 분석연구)

  • Son, Yeong-Jin;Park, Keun-Soo;Min, Kyung-Yun
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.755-770
    • /
    • 2006
  • 1974. 8.15 SeoulMetro, beginning with the first electric railway established at six cities, so it is managing mass transportation of traffic. Especially, in case of seoul, It is managing that from one to eight lines, 286.9km, 265 stations have installed and now it is carrying about 5.5million of passengers everyday, and 2,000million passengers a year. So accident is increasing from the station every year. For this measure, SeoulMetro prepares safety fence for passengers crash but, as suicides or people who watch the accident took place, for at the bottom of passengers crash protection, PSD installing is needed. Even though, PSD is managing ATO section but, in controlling SeoulMetro, one to four lines sections are (ATS, ATC)section. Between as ATS, ATC section, ATO section, subway gate and PSD must have opened and crossed always at the time. And the interlock control corrosion protection gate, managing skills with installation, method, using in history, apply to 10rail cars one train sets, and maximum applying 224% sections of passengers congested that consideration is to be needed. So 2004, SeoulMetro improved technology and basic design of PSD at ATS section. Based on this, from 2005.4 to 2006.6, using subway 2lines per 12stations set the model installation(full type 11stations, half type 1station) After installing in case of success, it is going about to suggest that effective analysis and hereafter subject.

  • PDF

Hydraulic Compressor Safety Test for Hydrogen Stations (수소충전소용 유압식 압축기 안전성 시험에 관한 연구)

  • Seong, Hye-Jin;Hwang, Bom-Chan;Choi, Sung-Joon;Kim, Young-Kyu;Cho, Sung-Min
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.11
    • /
    • pp.8-15
    • /
    • 2020
  • The government has announced its Hydrogen Economy Roadmap to strengthen global competitiveness on the hydrogen economy by focusing on hydrogen fuel cell electric vehicles and fuel cells. In this regard, the interest on the economics and safety of the infrastructure of hydrogen stations has also increased. In this study, a test bed similar to an actual hydrogen charging facility was built, and a prototype of a piston-type compressor was modeled. In this model, the piston was hydraulically compressed to progressively test leakage, leakage rate, and durability and to check for any malfunction. Moreover, the leakage rate, cylinder leak performance, and compressor operation durability were evaluated for safety; it was confirmed that there were no abnormalities. Nevertheless, an investigation of the long-term use and operating pressure of the compressor is necessary to verify the safety of developing a100-MPa domestic compressor in the future.

Verification of Hybrid Real Time HVDC Simulator in Cheju-Haenam HVDC System

  • Yang Byeong-Mo;Kim Chan-Ki;Jung Gil-Jo;Moon Young-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.23-27
    • /
    • 2006
  • In this paper a Hybrid Real Time HVDC Simulator fur both operator Training and Researching in the Cheju-Haenam HVDC System is proposed and its performance is studied by means of RTDS (Real Time Digital Simulator), EMTDC (Electro-Magnetic Transients system for DC), PSS/E (Power System Simulator for Engineering), and experienced scenarios. The objective of this paper is to represent the strategy in development for KEPCO's hybrid HVDC simulator for the Cheju-Haenam HVDC system. This simulator consists of two DC stations, DC cables, external digital/analog controllers, monitoring systems and control desk for education, and AC networks. Its suitability for operator's education is tested during startup/shutdown and normal state operations. Dynamic performances of it are also verified.

Zero-forcing Beamforming for Hybrid Relaying (Hybrid Relaying을 위한 Zero-forcing Beamforming 기법)

  • Park, Jong-Rok;Ham, Sung-Jun;Lee, Sang-Hoon
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.251-252
    • /
    • 2008
  • Throughput and quality-of-service (QoS) over multi-cell environments are two of the most challenging issues that must be addressed when developing next generation wireless network standards. Currently, multiple-input/multiple-output (MIMO), inter-cell coordination and multi-hop relay technologies are viable options for improving channel capacity or coverage extension. Nevertheless, severe QoS degradation occurs in the outer region of multi-cells due to significant interference from neighboring cells or relay stations, thereby limiting overall performance. Therefore, we propose a scheme which adapted to hybrid relaying.

  • PDF

Development of Wire Rope Snubbers (Wire Rope형 진동완충장치 개발)

  • Park, Jong-Beom;An, Yong-Ho;Bae, Byung-Hong;Kim, Min-Bae
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.334-336
    • /
    • 1999
  • Piping systems of the power generating stations have been generally protected by hydraulic and mechanical snubbers which can allow large displacements arising from temperature change while those can reduce or absorb stresses due to vibrations. However these snubbers require amounts of budget for maintenance or replacement because of the leakage, lubrication and finally short life cycle. Recently the snubbers consisted of wire rope have been proved to reduce vibrations of piping systems. While the wire rope snubbers are free of maintenance such as leakage and lubrication imported price are so high. Now it is necessary to design. manufacture and certificate these wire rope snubbers.

  • PDF

A Statistical Analysis on the Electric Shocks in 2014 (2014년 감전사고 통계 분석)

  • Hong, Eun-Hee
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.171-179
    • /
    • 2015
  • As the industrial scale is getting enlarged and the people's quality of life is growing, the electric energy consumption has been rapidly increasing every year and the frequency of electrical accidents such as electrical shock This paper gives statistical analysis of the number of casualties caused by the electrical shock, five hundred people every year, but it still exceeded the shaping risk of electrical accidents to anyone in KOREA. In this paper, for the electrical shock of the in 2014 act by occupation, voltage electrical equipment, location, accident type and months. In order to acquire electrical shock in 2014, we visited police stations and hospitals and analyzed records of accidents. The result showed that the electrical shock alone caused 37 people deaths and 569 injuries.