• Title/Summary/Keyword: Electric stations

Search Result 191, Processing Time 0.026 seconds

A study on the Wireless Communication System for Korean Next Generation Reactor (차세대원전의 무선통신 적용에 대한 연구)

  • Chi, Mun-Goo;Han, Sung-Heum
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3175-3177
    • /
    • 1999
  • In this study, the wireless communication system configuration and major equipments for KNGR will be introduced. Also the reliability and safety impact on the KNGR will be checked by reviewing /testing the EMI/RFI conditions of wireless communication system, The elements of the wireless communication system are radio exchange, base stations, portable telephone handsets.

  • PDF

Independent Generation System Design for the Economic Management of Electrical Charging Stations (전기충전소의 경제적 운영을 위한 독립발전 시스템 설계)

  • Seo, Jin-Gyu;Kim, Kyu-Ho;Rhee, Sang-Bong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.222-227
    • /
    • 2015
  • This paper presents the optimal energy generation systems for economical EVs(Electric Vehicles) charging stations located in an island area. The system includes grid electricity, diesel generator and renewable energy sources of wind turbines and PV(Photovoltaic) panels. The independent generation system is designed with data resources such as annual average wind speed, solar radiation and the grid electricity price by calculating system cost under different structures. This sensitive analysis on the varying data resources allows for the configuration of the most economical generation system for charging stations by comparing initial capital, operating cost, NPC(Net Present Cost) and COE(Cost of Energy). Depending on the increase of the grid cost, the NPC variation of the most economical system which includes renewable energy generations and grid electricity can be smaller than those of other generation systems.

A Study on the Effective Development of Privately Financed Station Buildings (철도 민자역사의 효율적 개발 방안 연구)

  • Kim Byong-O;Chung Jae-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.4 s.35
    • /
    • pp.362-370
    • /
    • 2006
  • This study examines the current state of and the problems in privately financed station in Korea, and makes suggestions for improving future development of stations. Problems found in this research are as follows. First. the deployment of resting facilities needs to be planned according to whether the users of privately financed station buildings are electric railway passengers or national railway ones. Second, large scale developments with the object of raising operating revenues should be restrained. Third, there are not sufficient spaces for public benefit such as squares in front of stations. Fourth, the surroundings are congested due to lack of connection to neighboring areas through public transportation. Fifth, the absence of integrated development plans causes many inadequate effects on urban functions and views. Sixth, administrative processes for getting licenses and permits are complicated and relevant authorities are not cooperative. To solve these problems in privately financed station buildings, to contribute to the development of the community and to secure publicness, Many problems are not in station buildings themselves but come from insufficient consideration of relevant factors in constructing the buildings Thus, future development of station buildings and their surrounding areas should be planned in consideration of these problems. We expect that the development of areas surrounding railway stations not only improves railway stations themselves but also leads the environmental reform of urban spaces and activates the local community.

A Study on the Design of Small Unit SCADA System for Electric Railroad (전기철도용 소규모SCADA 시스템 설계방안에 관한 연구)

  • Lee, Seung-Chul;Shin, Kwan-Woo;Lee, Youn-Seop
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.2
    • /
    • pp.89-93
    • /
    • 2004
  • Supervisory Control And Data Acquisition(SCADA) of electric power system refersto the system that displays, monitors and executes the control commands for remote electric power system. KNR's existing electric power control system is built on UNIX platform such that it costs more for system construction, and people with UNIX skills can only be an operator who controls and manages the system. Moreover, since the system is mainly operated in local offices, system operators must communicate with local operators to investigate the cause of the accident and react the accident every time the system fails. As a new integrated SCADA system is constructed, establishment of small-unit electric power control system, that alters local electric power control system in designated stations, is required. In this study, the electric power control system, which accommodates all functions of UNIX-based SCADA system and facilitates operation and even maintenance for local operators, is to be developed. In order to develop small-unit electric power control system, the industrial automation program, "Cimon", is used. The small-unit electric power control system that accommodatesRTU and newly installed electronic switchboard is being developed and tested at Chulam station of KNR.

Development of a System Dynamics Computer Model for Efficient Operations of an Industrial Water Supply System (공업용수 공급시스템의 효율적인 운영을 위한 시스템다이내믹스 모형의 개발)

  • Kim, Bong-Jae;Park, Su-Wan;Kim, Tae-Yeong;Jeon, Dae-Hun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.383-397
    • /
    • 2012
  • In this study, a System Dynamics (SD) simulation model for the efficient operations of an industrial water supply system was developed by investigating the feedback loop mechanisms involved in the operations of the system. The system was modeled so that as demand is determined the water supply quantity of intake pumping stations and dams are allocated. The main feedback loop showed that many variables such as the combinations of pump operation, unit electric power(kWh/$m^3$), unit electric power costs(won/$m^3$), water level of water way tunnel, suction pressure and discharge of pumping station, and tank and service reservoir water level had causal effects and produced results depending on their causal relationship. The configurations of the model included an intake pumping station model, water way tunnel model, pumping station model (including the tank and service reservoir water level control model), and unit electric power model. The model was verified using the data from the case study industrial water supply system that consisted of a water treatment plant, two pumping stations and four dams with an annual energy costs of 5 billion won. It was shown that the electric power costs could have been saved 7~26% during the past six years if the operations had been based on the findings of this study.

Space Proposed in Accordance with the Usage Patterns and Analysis of the Charging Station Environment of Electric Vehicles

  • Hwang, Soon-Min;Kim, Dong-Chan
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.27-33
    • /
    • 2014
  • This study analyzed the electric vehicle recharging station status with recharging time limitation due to long waiting time, and figured out the user status by user interviews. And then this study verified the validity of hypothesis in terms of environmental design perspective and suggested layout of recharging station model. 21 recharging stations in Korea and station operation cases of 7 countries were examined. Except for the USA, the reality of electric vehicle recharging station today is the 1st proving stage focusing on the infrastructure construction of electric vehicle recharging station. It focuses on performance of recharging facility, use efficiency and operation environment of electric vehicle. About the effective waiting time of the user to use it should be studied. The current conditions of recharging station are as follows: Lack of independent recharging space, lack of facility that reduces external effect of recharging space, and lack of lounge for users during the waiting time. These three are essential factors constructing a suggesting model after basic layout, which needs proper measurement on the long recharging time and long waiting time. The essential factors are applied to electric vehicle recharging station layout so that users might use 'digital refresh" i.e. lounge and information contents service during the waiting time which provides convenience of recharging and emotional space with users. Such upgrade recharging station environmental model might resolve the burden of long recharging time which may contribute to the popularization of electric vehicles.

Analysis on the Falling Risk of Building Electric Shutter and Reduction Measures (건축물 전동셔터 추락 리스크 분석 및 저감 방안)

  • Jung, Young-Min;Bang, Hong-Soon;Kim, Ok-Kyue
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.295-296
    • /
    • 2021
  • With the recent diversification and complication of buildings, the functions of building are also developing. As much as the development of buildings, the machine or equipment used for them is also developing. Thus, all sorts of domestic/foreign industrial facilities and fire stations in the whole nation are using the electric shutter that could meet the insulation just like the exterior wall of general buildings, for bringing-in/storage and crime prevention/fire prevention. Currently, various types of electric shutters are used. Such wrong operation and poor management are causing many panel-falling accidents. This study researched the reduction of electric shutter panel-falling risk by reviewing the domestic/foreign laws and standards, and researching the new safety equipment. First, the causes for falling and accident types were drawn by analyzing the cases of electric shutter accidents. After that, a checklist as the measures for reducing the falling of electric shutter in building was suggested by analyzing the items for the inspection of electric shutter.

  • PDF

Development of Hydrogen Flow Field Standard in Hydrogen Refueling Station (수소충전유량 현장교정시스템의 개발 )

  • WOONG KANG;JINWOO SHIN;SAENG-HEE LEE;BYUNG-RO YOON;UNBONG BAEK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.684-691
    • /
    • 2022
  • Hydrogen fuel cell electric vehicles are typically refueled at a wide range of temperatures (-40℃ to 85℃) in the hydrogen refueling station in accordance with the worldwide accepted standard. Currently, there is no traceable method by which to verify and calibrate the hydrogen flowmeters to be used at hydrogen refueling stations except for a water calibration process as a conventional method. KRISS hydrogen field test standard based on the gravimetric principle was developed to verify the measurement accuracy of the mass flowmeter to be used at hydrogen refueling stations for the first time in Korea.

Electromagnetic Forces Measurement of Various Electric Appliances and Places (각종 전기기기 및 장소에서의 전자파 측정)

  • Kim, Deok-Won;Ryu, Chang-Yong;Kim, Su-Chan;Yoon, Hyung-Ro
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.179-182
    • /
    • 1995
  • Although air, water, and noise pollutions have been widely recognized, electromagnetic forces(EMF) hazard has been rarely recognized as a pollution and very little studies has been done in this country. Thus, in this study electromagnetic forces radiated by various home appliances, once machines, and communication equipments were measured and so were several places radiating strong EMF such as subway stations and electric substations. Among the home appliances microwave oven senates lots of magnetic field and microwaves, and electric mattress does strong magnetic field. In video game room strong magnetic and considerable electric fields were measured. It was observed strong magnetic field inside of electric powered train and very strong magnetic and electric fields on some platforms. Hand-phone and car-phone radiate very hazardous level of microwaves to brain and that they rapidly come into wide use. In this study data base for various electric machines and places radiating strong EMFs were constructed and could be used for future epidemiological studies.

  • PDF

Analysis of Hydrogen Sales Volume in Changwon (창원 수소충전소의 수소판매량 분석)

  • KANG, BOO MIN;KANG, YOUNG TAEC;LEE, SANG HYUN;KIM, NAM SEOK;YI, KYEONG EUN;PARK, MIN-JU;JEONG, CHANG-HOON;JEONG, DAE-WOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.4
    • /
    • pp.356-361
    • /
    • 2019
  • Since the government announced the roadmap to revitalize the hydrogen economy, we are constantly making the effort to expand the use of fuel cell electric vehicles (FCEV) and hydrogen charging stations. There is however a significant issue to build and operate the hydrogen charging station due to the lack of the profit model. Many researchers believe that the supply of FCEV will be increased in the near future and finally ensure the economy of hydrogen charging stations. This study shows that the sales changes of hydrogen gas and consumption patterns by the operation of the hydrogen charging station in Changwon City. The results will be used as the evidence to support for operating the hydrogen charging station by private businesses and the validity of additional establishment of hydrogen charging stations.