• Title/Summary/Keyword: Electric stations

Search Result 191, Processing Time 0.03 seconds

A Study on the Metal Wire for Hoop Wrapping of Type 2 High Pressure Tank (Type 2 고압용기 권선용 금속선재에 관한 연구)

  • HAN, JINMOOK;CHOI, SOOKWANG;LEE, SUNGHEE;CHO, KYUNGCHUL;HWANG, CHULMIN;JUNG, YOUNGUAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.4
    • /
    • pp.338-346
    • /
    • 2019
  • During last years, hydrogen refueling infrastructure test and devices research for hydrogen station presented a significant growth consisting of the commercialization of fuel cell electric vehicles (FCEVs). However, we still have many challenges for making commercial hydrogen stations such as increased safety and cost reduction. This study demonstrates the low cost hydrogen storage tank (type 2) and effective winding method for high pressure hydrogen storage. We use numerical analysis to verify stress changes inside the wire according to the winding condition. Also liner size, winding wire size and wire tension were studied for the safety and cost down. Results show that the stress of winding wire decreased with increased winding angle and increased the liner diameter. On the other hand, the stress of winding wire increased according to the increased wire thickness and tension.

Recent Research for the Seismic Activities and Crustal Velocity Structure (국내 지진활동 및 지각구조 연구동향)

  • Kim, Sung-Kyun;Jun, Myung-Soon;Jeon, Jeong-Soo
    • Economic and Environmental Geology
    • /
    • v.39 no.4 s.179
    • /
    • pp.369-384
    • /
    • 2006
  • Korean Peninsula, located on the southeastern part of Eurasian plate, belongs to the intraplate region. The characteristics of intraplate earthquake show the low and rare seismicity and the sparse and irregular distribution of epicenters comparing to interplate earthquake. To evaluate the exact seismic activity in intraplate region, long-term seismic data including historical earthquake data should be archived. Fortunately the long-term historical earthquake records about 2,000 years are available in Korea Peninsula. By the analysis of this historical and instrumental earthquake data, seismic activity was very high in 16-18 centuries and is more active at the Yellow sea area than East sea area. Comparing to the high seismic activity of the north-eastern China in 16-18 centuries, it is inferred that seismic activity in two regions shows close relationship. Also general trend of epicenter distribution shows the SE-NW direction. In Korea Peninsula, the first seismic station was installed at Incheon in 1905 and 5 additional seismic stations were installed till 1943. There was no seismic station from 1945 to 1962, but a World Wide Standardized Seismograph was installed at Seoul in 1963. In 1990, Korean Meteorological Adminstration(KMA) had established centralized modem seismic network in real-time, consisted of 12 stations. After that time, many institutes tried to expand their own seismic networks in Korea Peninsula. Now KMA operates 35 velocity-type seismic stations and 75 accelerometers and Korea Institute of Geoscience and Mineral Resources operates 32 and 16 stations, respectively. Korea Institute of Nuclear Safety and Korea Electric Power Research Institute operate 4 and 13 stations, consisted of velocity-type and accelerometer. In and around the Korean Peninsula, 27 intraplate earthquake mechanisms since 1936 were analyzed to understand the regional stress orientation and tectonics. These earthquakes are largest ones in this century and may represent the characteristics of earthquake in this region. Focal mechanism of these earthquakes show predominant strike-slip faulting with small amount of thrust components. The average P-axis is almost horizontal ENE-WSW. In north-eastern China, strike-slip faulting is dominant and nearly horizontal average P-axis in ENE-WSW is very similar with the Korean Peninsula. On the other hand, in the eastern part of East Sea, thrust faulting is dominant and average P-axis is horizontal with ESE-WNW. This indicate that not only the subducting Pacific Plate in east but also the indenting Indian Plate controls earthquake mechanism in the far east of the Eurasian Plate. Crustal velocity model is very important to determine the hypocenters of the local earthquakes. But the crust model in and around Korean Peninsula is not clear till now, because the sufficient seismic data could not accumulated. To solve this problem, reflection and refraction seismic survey and seismic wave analysis method were simultaneously applied to two long cross-section traversing the southern Korean Peninsula since 2002. This survey should be continuously conducted.

A case study on optimal location modeling of battery swapping & charging facility for the electric bus system (전기버스를 위한 배터리 자동 교환-충전인프라 배치 최적화 모형개발 및 적용 사례 분석)

  • Kim, Seung-Ji;Kim, Wonkyu;Kim, Byung Jong;Im, Hyun Seop
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.1
    • /
    • pp.121-135
    • /
    • 2013
  • This paper propose an efficient algorithm for selecting electric bus charging facility location. In nature, the optimal charging facility location problem is similar to Set Covering Problem. Set Covering Problem is the problem of covering all the rows of an $m{\times}n$ matrix of ones and zeros by a subset of columns with a minimal cost. It has many practical applications of modeling of real world problems. The Set Covering Problem has been proven to be NP-Complete. In order to overcome the computational complexity involved in seeking optimal solutions, this paper present an enhanced greedy algorithm and simulated annealing algorithm. In this paper, we apply the developed algorithm to Seoul's public bus system.

Analysis of New & Renewable Energy Application and Energy Consumption in Public Buildings (공공건축물의 신재생에너지 적용과 에너지 사용량 분석)

  • Lee, Yong-Ho;Seo, Sang-Hyun;Kim, Hyung-Jin;Cho, Young-Hum;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.153-161
    • /
    • 2012
  • This study conducted a survey and field investigation on the application of the Public Obligation System for new & renewable energy in public buildings, as well as energy consumption of each building according to their uses. The findings are as follows: (1) Since the introduction of the Public Obligation System (until June 30, 2011), there was average 1.4 new & renewable energy facilities established at 1,433 places. Preference for solar energy facilities was the highest at 57.8%. (2) The revised act sets the obligatory supply percentage of new & renewable energy for each public building: it is 9.0% for a tax office, 4.2% for a dong office, 8.2% for a public health center, and 12.6% for a fire station. All the public buildings except for fire stations failed to meet 10% expected energy consumption, a revised standard. (3) Energy consumption of each public building was 120.6TOE for a tax office, 124.3TOE for a dong office, 166.4TOE for a public health center, and 174.6TOE for a fire station. The energy consumption was comprised of 80% electric power, 18% urban gas, and 1% oil. (4) Electric power consumption per person in the room was high at a dong office, and fuel consumption per person in the room was high at a public health center. In addition, electric power consumption per unit space was high at a public health center, and fuel consumption per unit space was high at a fire station. (5) In all the four public buildings, power load had the highest basic unit percentage at average 55%, being followed by heating load (21.2%), cooling load (15%), and water heating load (7%). A tax office and fire station had 2% load due to cooking facilities.

A Cell Selection Technique Considering MIMO Precoding (MIMO 프리코딩을 고려한 셀 탐색 기법)

  • Kim, Han Seong;Hong, Tae Howan;Cho, Yong Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37A no.12
    • /
    • pp.1076-1084
    • /
    • 2012
  • In the CS/CB(Coordinated Scheduling/Beamforming) scheme, the cell edge user throughput is increased by selecting MIMO (Multiple Input Multiple Output) precoders which can minimize the interferences from adjacent base stations (BSs). However, in current LTE(Long Term Evolution) systems, the serving cell is selected in the initialization stage by using the synchronization signals and cell specific reference signals transmitted by adjacent BSs with a single antenna. The selected BS in the initialization stage may not be the best one since the MIMO precoding gain has not been considered in the cell selection stage. In this paper, a new cell selection technique is proposed for LTE systems with MIMO precoder by taking into account the effect of the precoder in the initialization stage. The proposed technique enables a user equipment (UE) in the cell boundary to select the serving BS by using the information (channel rank, effective channel capacity, and effective SINR(Signal to Interference plus Noise Ratio)) acquired from cell specific reference signals of candidate BSs. It is verified by computer simulation that the proposed technique can increase the channel capacity significantly in the multi-cell environments, compared with the conventional CS/CB scheme.

Changes in spatial organization of Korea by the construction of Seoul-Pusan railroad (京釜線 鐵道建設에 따른 韓半島 空間組織의 變化)

  • ;Joo, Kyung-Sik
    • Journal of the Korean Geographical Society
    • /
    • v.29 no.3
    • /
    • pp.297-317
    • /
    • 1994
  • This study demonstrates the changes in the spatial organization of Korea by the construction of Seoul-Pusan railroad. This Seoul-Pusan line, which is the most important one in Korea was constructed in 1905. The original plan of the line was selected to cross the main traditional roads to control the entire Korean peninsular and to mobilize the Korean commercial potentials. It was the line to exploit the staples and to expand the Japanese market in Korea. In accordance with the contracts between Japan and Korean government, Korean government had to supply the lands for railroad, office, and service facilities. That was one of the important reasons that Korean government had been broken down. The main findings of this study are as follows: 1. The Seoul-Pusan railroad line was constructed Japanese colonial policy which emphasized three main purposes; the first was to reorganize the economic space and to collapse the traditional Korean markets for Japanese ruling, and the second was to find out the military supply routes, and the third was to search for the transcontinental line for China and Siberia. As the results, the old Korean pedestrian routes, which were the Eastern, the mid, the westren, and the Samnam route lost their functions. 2. Japanese requested for Korean government usually ten times of wider space for the site of stations than the needed one. The land was expropriated, and constructed the new centers aparted from the original Korean towns. In this process Japanese got the most developmental and windfall profits. The newly constructed centers were for Japanese immigration and the town service facilities which would be used to control the Korean financial market. At last, they easily converted the Korean spatial economy into Japanese colonial one, which made to reinforce the sphere of Seoul-Pusan line. 3. Japanese planned the stations as the central points in Korea. So the railroad stations were located apart from the centers of towns, to avoid the Korean resistances, and to maximize their profits. The mean distance from staiton to 'the town center is about 1km while the Japanese case is 0.6km. 4. The pattern of present Korean railroads is not the 'X type'. Because the Honam line is not the trunk one. So, we could call the Korean railroad pattern as the 'Ip(Chinese character 入) type' . The operational effects of Seoul-Pusan line brought out the concentration of the national economy to this line as Japanese planned. And the polorization had occurred between this line and the other parts of Korea. For twenty years (1910-1930), the transported freights were increased about 5 times. In 1930, the total freight of Seoul-Pusan line became 2, 010, 444 metric tons. If we examine this process, the underconstructing Seoul-Pusan express electric railroad should avoid adjacent this line to reduce the regional and ecological imbalance. 5. The forms of centers on the Seoul-Pusan line were classified into six types in relation to station, town center, and built-up area; the compact (integrated) type, the elongated one, the splited (independent) one, the absorbed one, the consolidated one, and the declined one. All types of these towns might be developed in accordance with the centrality, railroad function, and the other transportational functions. 6. The Seoul-Pusan line plays the most important role among Korean railroads but the ratio of passenger and freight become lower because the effiects of other inaugurated railoads the different transportation modes such as trucks and cars would be got more merits in competition. 7. The results of cluster analyses on the cities of railroad stations showed the rudimentary urban systems in 1910 and 1930. In 1930, the cities were classified into three groups; the group of small cites, the intermediate (developing) city-group, and the special city-group. In 1930s the spatial organization and urban system of Korea were similar to the present ones. We call appreciate that these were the effects of the Seoul-Pusan line.

  • PDF

Analysis of Sheath Temperatures and Load Currents Dependent on Conductor Temperatures in Live 6kV CV Cables Operating at a Power Station (발전소에서 운전 중인 활선 6 kV CV 단심 cable의 도체온도에 따른 피복 표면온도 및 부하전류 특성 분석)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.3
    • /
    • pp.189-195
    • /
    • 2017
  • The only method used in the power stations in order to deliver generated electric power is 6 kV XLPE (or CV) single core cables. Among many kinds of accidents happening in the power stations, the outbreak of fire due to the deterioration of live cables causes enormous socioeconomic losses. From the installation of the cables, the management and diagnose should be thoroughly made. Even though it differs depending on the installations and usage conditions, the cross-sectional area of cables is in shortage. The excessive allowable temperature caused from the current causes the deterioration of cables. In order to prevent an unexpected breakdown of live cables, we have invented a device to monitor and diagnose the status of cables. We have installed our device in the Korea Western Power Co., Ltd.. In this paper, we present our research results in situ that we have obtained by measuring the temperature of sheath, changing with the surrounding circumstances, especially ambient temperatures. We also show our study results of characteristics for temperature of sheath surface and load current at the ambient temperatures of $40^{\circ}C-10^{\circ}C$.

A Study on Hazards Assessment of Electrostatic Firing Explosion of Working Wears at LPG Stations in Korea (한국의 LPG 충전소에 있어서 작업복의 정전기에 의한 화재 및 폭발 위험성에 관한 연구)

  • Cho young doo;Koo Ja Hyeuk;Choi Kwang Seo;Seo Dae Won;Joung Jae Hee;Takeuchi Manabu
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.4 s.12
    • /
    • pp.20-24
    • /
    • 2000
  • The electrostatic safety consciousness of safety manager were investigated through questionnaires sent to liquid petroleum gas stations in Korea. In addition, hazards of fire and explosion due to electrostatic on synthetic-polymer-wears and cotton-wears were estimated experimentally. The results of questionnaires indicate most workers wear their working clothes indiscreetly owing to lack of knowledge of preventing electrostatic hazards. The amounts of electrostatic charge generated in synthetic-polymer-wears were 1.79, 1.44 and 1.02 $\mu$C in winter, spring and autumn and summer, respectively. All these values exceed the limit of working wears of 0.60$\mu$C requested by Korea Standard(KS K-7807) for preventing electrostatic hazards, which means hazards may occur. While, the charge in cotton-wears were in the range of 0.42 to 0.52$\mu$C, which suggests that the cotton-wears investigated in this study have no problem of hazards. Therefore workers, visual and experiential education are necessary for elevating the standard of on electrostatics. It is also necessary to establish standards of wearing for preventing electrostatic hazards.

  • PDF

Fault rupture directivity of Odaesan Earthquake (M=4.8, '07. 1. 20) (오대산지진(M=4.8, '07. 1. 20)의 단층파열방향성)

  • Yun, Kwan-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.2
    • /
    • pp.137-147
    • /
    • 2008
  • Fault rupture directivity of the Odaesan earthquake, which was inferred to be the main cause of the high PGAvalue (> 0.1 g) unusually observed at the near-source region, was analyzed by using the data from the nearby (R < 100 km) dense seismic stations. The Boatwright's method (2007) was adopted for this purpose in which the azimuth and takeoff angle of the unilateral rupture directivity function could be estimated based on the relative peak ground-motions of seismic stations resulting from the nature of the rupture directivity. In this study, the approximate values of the relative peak ground-motions was derived from the difference between the log residuals of the point-source spectral model (Boore, 2003) for the main and secondary events based on the Random Vibration Theory. In this derivation, the spectral difference for a frequency range between the source corner frequencies of main and secondary events was considered to reflect only the effect of the fault directivity. The inversion result of the model parameters for the fault directivity function showed that the fault-plane of NWW-SEE direction dipping steeply to the North with high rupture velocity near upward in SE direction is responsible for the observed high level of ground-motion at the near-source region.

Electromagnetic Interference of GMDSS MF/HF Band by Offshore Wind Farm (해상풍력 발전단지에 의한 GMDSS MF/HF 대역 전자파 간섭 영향 연구)

  • Oh, Seongwon;Park, Tae-Yong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.1
    • /
    • pp.47-52
    • /
    • 2021
  • Recently, the share of wind power in energy markets has sharply increased with the active development of renewable energy internationally. In particular, large-scale wind farms are being developed far from the coast to make use of abundant wind resources and to reduce noise pollution. In addition to the electromagnetic interference (EMI) caused by offshore wind farms to coastal or air surveillance radars, it is necessary to investigate the EMI on global maritime distress and safety system (GMDSS) communications between ship and coastal stations. For this purpose, this study investigates whether the transmitted field of MF/HF band from a ship would be subject to interference or attenuation below the threshold at a coastal receiver. First, using geographic information system digital maps and 3D CAD models of wind turbines, the area of interest is electromagnetically modeled with patch models. Although high frequency analysis methods like Physical Optics are appropriate to analyze wide areas compared to its wavelength, the high frequency analysis method is first verified with an accurate low frequency analysis method by simplifying the surrounding area and turbines. As a result, the received wave power is almost the same regardless of whether the wind farms are located between ships and coastal stations. From this result, although wind turbines are large structures, the size is only a few wavelengths, so it does not interfere with the electric field of MF/HF distress communications.