• Title/Summary/Keyword: Electric safety

Search Result 1,827, Processing Time 0.031 seconds

A Study on the Concept of Operation of Low-density Operation in Urban Air Mobility from the Perspective of an Airline (운항사 관점의 저밀도 도심항공교통 운항통제 운용개념 연구)

  • Sunghyun Jin;Heeduk Cho;Daniel Kim;Jaewoo Kim
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.2
    • /
    • pp.201-209
    • /
    • 2024
  • This study investigates the operational facets of low-density urban air mobility (UAM) from an airline's perspective amid burgeoning concerns about urban congestion in megacities. UAM, employing electric vertical takeoff and landing (eVTOL) technology, emerges as a potential remedy to the challenges of traffic gridlock and environmental degradation. As the UAM market progresses from initial stages to maturity, tailored traffic control systems become paramount. Focused on the context of low-density environments during UAM's inception, this research scrutinizes operational frameworks, essential infrastructure, and likely scenarios. It aims to bolster the safety and efficiency of UAM operations by delving into the specifics of traffic control concepts designed for these unique settings. The study seeks to significantly contribute to optimizing UAM's initial phases, providing insights into crucial operational dynamics for a smoother integration of urban air mobility into contemporary urban landscapes.

Home Bioelectrical Impedance Analysis Management System in Patients With Heart Failure: Rationale and Study Design

  • Min Gyu Kong;Inki Moon;Hye-Sun Seo;Jon Suh;Jah Yeon Choi;Jin Oh Na;Eung Ju Kim
    • International Journal of Heart Failure
    • /
    • v.6 no.1
    • /
    • pp.22-27
    • /
    • 2024
  • Body fluid monitoring and management are essential to control dyspnea and prevent re-hospitalization in patients with chronic heart failure (HF). There are several methods to estimate and monitor patient's volume status, such as symptoms, signs, body weight, and implantable devices. However, these methods might be difficult to use for reasons that are slow to reflect body water change, inaccurate in specific patients' condition, or invasive. Bioelectrical impedance analysis (BIA) is a novel method for body water monitoring in patients with HF, and the value in prognosis has been proven in previous studies. We aim to determine the efficacy and safety of home BIA body water monitoring-guided HF treatment in patients with chronic HF. This multi-center, open-label, randomized control trial will enroll patients with HF who are taking loop diuretics. The home BIA group patients will be monitored for body water using a home BIA device and receive messages regarding their edema status and direction of additional diuretics usage or behavioral changes through the linked application system once weekly. The control group patients will receive the usual HF management. The primary endpoint is the change in N-terminal prohormone of brain natriuretic peptide levels from baseline after 12 weeks. This trial will provide crucial evidence for patient management with a novel home BIA body water monitoring system in patients with HF.

Design Study of Digital Map Architecture for AAV (미래형 항공기체(AAV)용 전자지도 아키텍처 설계 연구)

  • Kyung-Chul Choi;Ji-Hun Kim;Nak-Min Choi;Gyong-Hoon Baek
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.4
    • /
    • pp.393-399
    • /
    • 2024
  • The digital map computer for advanced air vehicles (AAV) must be high-performance, lightweight, portable, and modular. It should receive data on terrain, weather, and obstacles from external modules to display digital maps accurately. This necessitates robust communication capabilities with external devices via an Ethernet interface and the ability to output digital map visuals clearly through an high-defintion multimedia Interface (HDMI) or digital visual interface (DVI) interface. This paper presents the design of both hardware and software architecture that fulfills these critical requirements for an AAV digital map system. Additionally, it establishes the minimum specifications needed and verifies the suitability of the designed digital map computer through rigorous performance measurements and testing. By ensuring these standards, the digital map computer can reliably support the complex navigational needs of AAV, enhancing operational efficiency and safety.

Structural Behavior of Mixed $LiMn_2O_4-LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ Cathode in Li-ion Cells during Electrochemical Cycling

  • Yun, Won-Seop;Lee, Sang-U
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.5-5
    • /
    • 2011
  • The research and development of hybrid electric vehicle (HEV), plug-in hybrid electric vehicle (PHEV) and electric vehicle (EV) are intensified due to the energy crisis and environmental concerns. In order to meet the challenging requirements of powering HEV, PHEV and EV, the current lithium battery technology needs to be significantly improved in terms of the cost, safety, power and energy density, as well as the calendar and cycle life. One new technology being developed is the utilization of composite cathode by mixing two different types of insertion compounds [e.g., spinel $LiMn_2O_4$ and layered $LiMO_2$ (M=Ni, Co, and Mn)]. Recently, some studies on mixing two different types of cathode materials to make a composite cathode have been reported, which were aimed at reducing cost and improving self-discharge. Numata et al. reported that when stored in a sealed can together with electrolyte at $80^{\circ}C$ for 10 days, the concentrations of both HF and $Mn^{2+}$ were lower in the can containing $LiMn_2O_4$ blended with $LiNi_{0.8}Co_{0.2}O_2$ than that containing $LiMn_2O_4$ only. That reports clearly showed that this blending technique can prevent the decline in capacity caused by cycling or storage at elevated temperatures. However, not much work has been reported on the charge-discharge characteristics and related structural phase transitions for these composite cathodes. In this presentation, we will report our in situ x-ray diffraction studies on this mixed composite cathode material during charge-discharge cycling. The mixed cathodes were incorporated into in situ XRD cells with a Li foil anode, a Celgard separator, and a 1M $LiPF_6$ electrolyte in a 1 : 1 EC : DMC solvent (LP 30 from EM Industries, Inc.). For in situ XRD cell, Mylar windows were used as has been described in detail elsewhere. All of these in situ XRD spectra were collected on beam line X18A at National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory using two different detectors. One is a conventional scintillation detector with data collection at 0.02 degree in two theta angle for each step. The other is a wide angle position sensitive detector (PSD). The wavelengths used were 1.1950 ${\AA}$ for the scintillation detector and 0.9999 A for the PSD. The newly installed PSD at beam line X18A of NSLS can collect XRD patterns as short as a few minutes covering $90^{\circ}$ of two theta angles simultaneously with good signal to noise ratio. It significantly reduced the data collection time for each scan, giving us a great advantage in studying the phase transition in real time. The two theta angles of all the XRD spectra presented in this paper have been recalculated and converted to corresponding angles for ${\lambda}=1.54\;{\AA}$, which is the wavelength of conventional x-ray tube source with Cu-$k{\alpha}$ radiation, for easy comparison with data in other literatures. The structural changes of the composite cathode made by mixing spinel $LiMn_2O_4$ and layered $Li-Ni_{1/3}Co_{1/3}Mn_{1/3}O_2$ in 1 : 1 wt% in both Li-half and Li-ion cells during charge/discharge are studied by in situ XRD. During the first charge up to ~5.2 V vs. $Li/Li^+$, the in situ XRD spectra for the composite cathode in the Li-half cell track the structural changes of each component. At the early stage of charge, the lithium extraction takes place in the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component only. When the cell voltage reaches at ~4.0 V vs. $Li/Li^+$, lithium extraction from the spinel $LiMn_2O_4$ component starts and becomes the major contributor for the cell capacity due to the higher rate capability of $LiMn_2O_4$. When the voltage passed 4.3 V, the major structural changes are from the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, while the $LiMn_2O_4$ component is almost unchanged. In the Li-ion cell using a MCMB anode and a composite cathode cycled between 2.5 V and 4.2 V, the structural changes are dominated by the spinel $LiMn_2O_4$ component, with much less changes in the layered $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, comparing with the Li-half cell results. These results give us valuable information about the structural changes relating to the contributions of each individual component to the cell capacity at certain charge/discharge state, which are helpful in designing and optimizing the composite cathode using spinel- and layered-type materials for Li-ion battery research. More detailed discussion will be presented at the meeting.

  • PDF

Physical Dosimetry in Radioactive Iodine Treatment in the Patients with Thyroid Cancer (갑상선암 환자에 대한 방사성옥소 치료시 물리적 선량 측정)

  • Kim, Myung-Seon;Jeong, Nae-In;Lee, Jai-Yong;Kim, Chong-Soon;Kim, Chong-Ho;Lee, Myung-Chul;Koh, Channg-Soon;Kim, Hee-Geun;Kang, Duck-Won;Song, Myung-Jae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.124-132
    • /
    • 1994
  • Radioactive iodine has been widely used in patients with thyroid cancer combined with surgical treatment. However, due to individual variations in absorption and excretion and uptake by tumor tissue of radioactive iodine, there are differences in therapeutic effect and adverse effects even if the same doses are administrated. So this study compared the therapeutic effect and radiation hazard by measuring internal radiation dose. Of total 27 patients with well differentiated thyroid cancer who had been thyroidectomized, we administered radioactive iodine 100 mCi, 150 mCi, 200 mCi. According to BEL DOSIMETRY PROTO-COL, beta and gamma ray dose were estimated from a pelt of the logarithm of the percent of dose per liter of whole blood versus day, and percent dose retained versus day using somilogarithmic paper, respectively. 1) Physical dose to whole blood averaged $56.54{\pm}13.02$ rad in 100 mCi administered group, $76.83{\pm}19.97$ rad in 150 mCi administered group, $95.08{\pm}25.51$ rad in 200 mCi administered group and there has been a significant correlation among the groups. 2) Mean percent dose retained 48 hours later was 26.34%. 3) There was no significant correlation of physical dose between absence and presence of metastasis. 4) 17 of 19 patients who has been followed up with TSH and serum throglobulin, Thallium scan were successfully ablated by radioactive iodine. 5) Leukocyte, lymphocyte, neutrophil, platelet counts all deelined in 4.6 weeks and most of all were restored 3 months later. 6) There was no significant correlation between physical dosimetry and biologic dosimetry. Generally administered doses of radioactive iodine (100-200 mCi) to patients with thyroid cancer postoperatively had developed transient bone marrow suppression and minimal chromosomal aberration, but they were within safety dose to blood (200 rad). And there has been no significant differences in residual dose 48 hours later between Korean and western people.

  • PDF

A study on Indoor Insulating Tent Design for Senior Citizens who Live Alone (독거노인을 위한 융복합 실내 보온용 텐트디자인에 관한 연구)

  • Lee, Dae Hyun;Kim, Sang Sik
    • Korea Science and Art Forum
    • /
    • v.37 no.2
    • /
    • pp.219-230
    • /
    • 2019
  • According to the National Statistical Office, the number of senior citizens aged 65 or over has exceeded 7 million as of 2017, and the number of senior citizens who live alone among them exceeded 1.3 million. Most of the senior citizens who live alone suffer from absolute poverty (68.5% of them has monthly income less than 500,000 won) and they have difficulties for basic living in the blind spot of our society. In particular, the heating is quite a serious issue for the senior citizens who live alone and belong to vulnerable social group in the winter, and to make it worse, they are exposed to frequent fire accidents due to the negligence in handling electric appliances such as electric heaters and electric pads. The main reason the indoor tent products are being used by senior citizens who live alone is that it saves energy, ensures warm sleep, and improves fire safety. Following the expansion of the indoor tent market, this study focused on the idea that there is a need for an in door tent suitable for senior citizens who live alone and belong to low income bracket and intended to improve its efficiency in relation to use, resting, and storage. For this, a basic survey was conducted on the products of existing brands to analyze advantages and disadvantages and it was possible to understand the demands that consumers have for existing products. Accordingly, a survey on consumer preference was conducted using a designed model and the Zabara typp, which demonstrated the best efficiency in terms of installation convenience, space usability, and appearance design was selected. Based on the results of selection, the product design and final prototype were completed. The results and details of the study are as follows; First, factors that were not recognized in product development phase could be identified through usability survey and interview with actual users. Second, for the effective aspect of the prototype, senior citizens could install and fold the tend more easily and quickly than expected. Based on these results of this study, it is expected that not only senior citizens who live alone but also various other users can use the tent to create another comfortable private space indoors.

A Study on the Current Fire Insurance Subscription and Solutions for Ensuring the Safety of the Traditional Market (전통시장 안전성 확보를 위한 개선방안: 화재보험 가입실태를 중심으로)

  • Kim, Yoo-Oh;Byun, Chung-Gyu;Ryu, Tae-Chang
    • Journal of Distribution Science
    • /
    • v.9 no.4
    • /
    • pp.43-50
    • /
    • 2011
  • Concerning the risk factors of the outbreak of a fire in a traditional market, most of those markets are located in downtown areas or residential areas; thus, although their location may be favorable in terms of marketability, they face a potential risk in that a fire may develop into a large blaze owing to poor environment or the absence of facilities prepared for disaster during a fire. Moreover, as many people are densely poised in the markets, it is very probable that a fire may occur owing to the excessive use of heaters in the winter as well as the reckless use of electric and gas facilities. It seems that traditional markets encounter difficulty being insured against fire, because of their vulnerability and that the vast majority of small-scale sellers are likely to suffer mental anguish and tremendous physical injury in case of a fire. However, most of those sellers in the traditional markets are hand-to-mouth sellers, and they lack awareness of safety concerns and have insufficient experience in safe facility management. As small-scale sellers constitute the majority in the traditional market, the subscription rate of fire insurance in most of the traditional markets is low for the reasons of their needy circumstances and their financial burden. Statistically, the subscription by street vendors is non-existent; therefore, these vendors have a fairly limited access to indemnification after fire damage. Because of these problems, this study's purpose is to identify the current level of insurance subscription by these markets, which are exposed to poor facilities and vulnerability to fire. In order to fix this, it appears that shop owners and consumers will have to band together. For this study, we executed a fire policyholder fact-finding mission at traditional markets with approximately 108 and 981 stores. The research method was executed by an investigation using one-on-one individual interviews using a questionnaire. The contents investigated current insurance subscriptions. The method of analysis looked at the difference of insured amount according to volume size through cross-tabulation of the difference of insured amount by possession form, difference of insured amount by market form, difference of insured amount by category of business, difference of insured amount by market size, etc. Furthermore, the study should be used to propose solutions for problems through theoretical review with the use of a literature research, because the field case study was through interviews with the persons concerned, and the survey of the current insurance subscriptions by traditional market shopkeepers. The traditional market would generally have difficulty affording fire insurance. Fire insurance subscription rates of most of the market proved to be inactive, because of the economic burden of payment. Lack of funds is thought to be the main factor that causes a lack of realization about the necessity of fire insurance. In addition to expensive insurance premiums, sometimes, the companies' valuation of the businesses is lower than their actual valuations, and they do not pay out enough during a claim. The research presents an improvement plan that, when presented at the traditional markets, may strengthen their ability to procure fire insurance through the help of the central government. Researchers connected with the traditional market mainly accomplish the initial research. However, although this research has its limitations, it offers considerable benefits. For future researchers, I would suggest looking at several regions for comparison.

  • PDF

A Survey on the Workplace Environment and Personal Protective Equipment of Poultry Farmers (양계 농업인의 작업장 환경 및 개인보호구 착용 실태조사)

  • Kim, Insoo;Kim, Kyung-Ran;Lee, Kyung-Suk;Chae, Hye-Seon;Kim, Sungwoo
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.6
    • /
    • pp.454-468
    • /
    • 2014
  • Objectives: This study was conducted to investigate the actual condition of the farm work environment and personal protective equipment as part of the effort to improve livestock work for the safety and health of poultry farmers and provide basic data for establishing plans to improve and develop personal protective equipment. Methods: For this purpose, a questionnaire survey on general information about stables, the poultry work environment, accidents, the wearing of work clothes and personal protective equipment, and the level of awareness related to personal protective equipment was conducted among 148 poultry farmers. Results: As a result, it was found that poultry workplace environment was exposed to such risks as fine dusts; organic dusts; poisonous gases; odorous substances; chicken excrement; contact with chickens, bacteria or viruses; and accidents related to machine operation. Thirteen percent of respondents suffered severe respiratory diseases, and the most frequently injured sites due to accidents were the hands (25.7%), knees (23.8%), arms (17.3%), and head (10.9%). The most frequent type of accident was collisions between the body and obstacles or machinery during movement (36.4%), followed by erroneous machine operation such as feeders and electric shocks (8.5%). Regarding the wearing of work clothes and personal protective equipment, 51.7% of the respondents wore worn-out clothing or everyday clothes, whereas only 32.0% wore work clothes. The percentage of farmers who wore proper protective equipment for the work environment during poultry work was 48.4%. The most frequently used type of protective equipment was boots (38.9%), followed by mask (36.7%), gloves (36.3%), appropriate work clothes (22.6%), quarantine clothes (17.6%), helmets (13.4%), and goggles (12.6%). The rate of wearing goggles was low because they were considered inconvenient and lowered work efficiency. Furthermore, they purchased everyday products available on the market for their personal protective equipment which were not appropriate for maintaining safety in an actual harmful environment and its consequent risks. As a result of the survey of the awareness level related to personal protective equipment, their levels of awareness of accidents and attitude proved to be average or higher, but the practice of wearing protective equipment and the level of knowledge and management of personal protective equipment were lower. Conclusion: This survey found that the wearing status of personal protective equipment among poultry farmers was insufficient even though they were exposed to risks. Most respondents were aware of the necessity of wearing personal protective equipment and of the potential for accidents, but they did not wear proper protective equipment. Their wearing rate was low due to a lack of knowledge about protective equipment, as well as the inconvenience of wearing it. Therefore there is a need to improve and develop specialized personal protective equipment for respiration, hands, and eyes, as well as work clothes that can protect farmers from major harmful matter that is generated in the poultry workplace. Based on the results of this investigation, we will conduct further studies on the required performance and design directions of personal protective equipment while collecting more objective data through field-oriented assessments.

A Study on Improvement Methods of Cost Estimation in Order for the Proper Management of Street Trees (도시 가로수 관리 품셈 개선에 관한 연구)

  • Do, Yoon-Taek;Han, Bong-Ho;Park, Seok-Cheol
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.4
    • /
    • pp.20-36
    • /
    • 2022
  • This study aims to provide basic data for high-quality street tree management by setting reasonable management items and appropriate unit prices by reviewing the adequacy of current street tree management. Currently, street tree management items, except for street tree pruning, use general landscape tree quantity per unit for the street tree management quantity per unit. KEPCO (Korea Electric Power Corporation) applied pruning items from standard electric production infrastructure and carried out the activities at an average unit price of 51% lower for heavy pruning and 39% lower for light pruning than the standard estimate. This was judged to be a level that could not maintain or increase the quality of street tree management. It was determined that an appropriate standard unit price for street tree management was necessary. To improve the quantity per unit for the proper management of street trees, it was necessary to review costs in the field. However, due to the absence of data on actual construction costs in the domestic landscape field, detailed items of the US RSMeans Building Construction Cost Data (RSMeans) were reviewed, and the actual construction costs were calculated by applying personal domestic expenses. As a result, the standard of the estimated unit showed a good ratio of 107% for heavy pruning of street tree pruning compared to the actual construction cost, but light pruning was underestimated with a 59% ratio. Shrub pruning was 82%, weeding was 92%, tree fertilization was 87%, and windbreak wall installation was 91% under-engineered. In addition, it was also confirmed that the watering by sprinkler trucks and chemical spraying were over-designed compared to the actual construction cost at the rates of 118% and 124%, respectively. Due to the specificity of the street trees, the increase in personal expenses and the input cost of equipment, such as road safety controls, were judged to be the main cause of the underestimation of items. Therefore, it is necessary to add items related to street trees and general landscape trees to the landscape maintenance items of the standard of the estimated unit.

Fiber Optic Sensors for Smart Monitoring (스마트 모니터링용 광섬유센서)

  • Kim, Ki-Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.137-145
    • /
    • 2006
  • Recently, the interests in structural monitoring of civil infrastructures are increased. Especially, as the civil infrastructures such as bridges, tunnels and buildings become large-scale, it is necessary to monitor and maintain the safety state of the structures, which requires smart systems that can supply long-term monitoring during the service time of the structures. In this paper, we investigated the possibilities of fiber optic sensor application to the various structures. We investigate the possibility of using fiber optic Bragg grating sensors to joint structure. The sensors show good response to the structural behavior of the joint while electric gauges lack of sensitivity, durability and long term stability for continuous monitoring. We also apply fiber optic structural monitoring to the composite repaired concrete beam structure. Peel-out effects is detected with optical fiber Bragg grating sensors and the strain difference between main structure and repaired carbon sheets is observed when they separate each other. The real field test was performed to verify the behaviors of fiber Bragg grating sensors attached to the containment structure in Uljin nuclear power plant in Korea as a part of structural integrity test which demonstrates that the structural response of the non-prototype primary containment structures. The optical fiber Bragg grating sensor smart system which is the probable means for long term assessments can be applicable to monitoring of structural members in various civil infrastructures.