• 제목/요약/키워드: Electric resistance

검색결과 1,445건 처리시간 0.033초

상온 ECR-MOCVD에 의해 제조되는 Cu/C박막특성 (Characteristics of copper/C films on PET substrate prepared by ECR-MOCVD at room temperature)

  • 이중기;전법주;현진;변동진
    • 한국군사과학기술학회지
    • /
    • 제6권3호
    • /
    • pp.44-53
    • /
    • 2003
  • Cu/C films were prepared at room temperature under $Cu(hfac)_2-Ar-H_2$ atmosphere in order to obtain metallized polymer by using ECR-MOCVD(Electron Cyclotron Resonance Metal Organic Chemical Vapor Deposition) coupled with a DC bias system. The room temperature MOCVD on polymer substrate could be possible by collaboration of ECR and a DC bias. Structural analysis of the films by ECR was found that fine copper grains embedded in an amorphous polymer matrix with indistinctive interfacial layer. The increase in $H_2$ contents brought on copper-rich film formation with low electric resistance. On the other hand carbon-rich films with low sheet electric resistance were prepared in argon atmosphere. The electric sheet resistance of Cu/C films with good interfacial property were controlled at $10^8$~$10^0$ Ohm/sq. ranges by the $H_2$/Ar mole ratio and the shielding effectiveness of the film showed maximum up to 45dB in the our experimental range.

전기 저항을 이용한 실접촉 면적과 윤활 영역의 예측 (Estimation of Real Area of Contact and Lubrication Regimes using Electric Contact Resistance)

  • 이홍철;김대은
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2000년도 제32회 추계학술대회 정기총회
    • /
    • pp.11-17
    • /
    • 2000
  • The electric contact resistance between ball and disk was measured to estimate the real area of contact under dry and lubrication conditions. The results from the measured constriction resistance using the hypothesis of a single circular contact was compared with those of Hertzian contact theory and hardness. The resistance correlated well with the asperity contact area and friction when the ball slides on the flat disk spreaded with lubricant film. Therefore, the constriction resistance method was useful to identify the lubrication regimes with respect to various loads and speeds. The results of this work will aid in better prediction of lubrication regimes with respect to the operating conditions.

  • PDF

가열금형을 사용하는 강철과 알루미늄 이종금속판재의 전기저항 이중스폿용접 (Electric Resistance Double Spot Welding Process of Dissimilar Metal Plates of Steel and Aluminum by Using Heating Dies)

  • 김태현;;진인태
    • 소성∙가공
    • /
    • 제27권1호
    • /
    • pp.37-47
    • /
    • 2018
  • In this paper, a double spot welding process, utilizing electric resistance heating dies, is suggested for the spot welding of dissimilar metal plates for drawing and concurrent spot welding. This double welding process has two heating methods for the fusion welding at the interfacial zone between steel and aluminum plates, such as heating method by thermal conduction of electric resistance by welding current induced to heating dies, and heating method by electric resistance between contacted surfaces of two plates by welding current induced to copper electrode. This double welding process has welding variables such as each current induced in heating dies and in copper electrode, outer diameters of heating dies, and edge shape of copper electrode. Experiments for current conditions in welding process should be demanded in order to get successful welding strength. It was known that the welding strength could be reached to the value demanded on industry fields under such welding conditions as heating dies of outer ring dia.12mm contacted on steel plate, as heating dies of outer ring dia. 14mm contacted on aluminum plate, and as copper electrode of dia. 6.0mm, and as 3 times continuous heating method by $1^{st}$ current of 11 kA(9cycle), $2^{nd}$ current 11 kA(60cycle), $3^{rd}$ current 7 kA(60cycle) applied in steel heating dies and copper electrodes, flat edge of copper electrode, for double spot welding process of dissimilar metal plates of steel and aluminum of 1.0 mm thickness.

온도차 및 부하 저항에 따른 열전모듈의 발전 특성 분석 (Experimental Study on the Power Generation of a Thermoelectric Module with Temperature Difference and Load Resistance)

  • 이공훈;김욱중;고득용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1942-1947
    • /
    • 2007
  • A thermoelectric module can be used for cooling or power generation. The basic requirements to achieve a significant thermoelectric performance are the same for both generators and coolers. Thermoelectric modules with $Bi_2Te_3$ materials are usually employed in the cooling applications below room temperature but it can also be used for the power generation in the similar temperature range. In the present study, the power generation with a $Bi_2Te_3$ thermoelectric module has been investigated. The temperature difference between the hot and cold sides of the module is maintained with electric heater and cold water from the circulating water bath. The result shows that the electric current generated increases with temperature difference and decreases with the load resistance. However, the voltage increases with both the temperature difference and load resistance. The electric power increases with temperature difference and it has the maximum value when the load resistance is about 4 ${\Omega}$ for a given device.

  • PDF

Improved Direct Torque Control of Permanent Magnet Synchronous Electrical Vehicle Motor with Proportional-Integral Resistance Estimator

  • Hartani, Kada;Miloud, Yahia;Miloudi, Abdellah
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권3호
    • /
    • pp.451-461
    • /
    • 2010
  • Electric vehicles (EVs) require fast torque response and high drive efficiency. This paper describes a control scheme of fuzzy direct torque control of permanent magnet synchronous motor for EVs. This control strategy is extensively used in EV application. With direct torque control (DTC), the electromagnetic torque and stator flux can be estimated using the measured stator voltages and currents. The estimation depends on motor parameters, except for the stator resistance. The variation of stator resistance due to changes in temperature or frequency downgrades the performance of DTC, which is controlled by introducing errors in the estimated flux linkage vector and the electromagnetic torque. Thus, compensation for the effect of stator resistance variation becomes necessary. This work proposes the estimation of the stator resistance and its compensation using a proportional-integral estimation method. An electronic differential has been also used, which has the advantage of replacing loose, heavy, and inefficient mechanical transmission and mechanical differential with a more efficient, light, and small electric motors that are directly coupled to the wheels through a single gear or an in-wheel motor.

전기저항법에 의한 크리프 손상의 비파괴적 검출 (Non-destructive Detection of Creep Damage Based on Electric Resistance Technique)

  • 이해우;윤기봉;남승훈;소철호
    • 열처리공학회지
    • /
    • 제7권3호
    • /
    • pp.155-159
    • /
    • 1994
  • As Cr-Mo-V steels have excellent mechanical and creep properties at elevated temperatures, they are extensively used in power plants. However, the steam turbine components are supposed to have suffered material degradation during long-term service at elevated tenperatures. Many efforts have been made to assess the safety and residual life of these components by means of non-destructive methods such as plastic replication, hardness and electric resistance techniques. Recently, a parameter correlating hardness changes during long-term heating to those during creep was introduced and it was named 'G parameter'. The electric resistivity as well as hardness are affected by damage accumulation, but there have been no efforts to correlate G parameter to resistivity changes. In this study, relationship between G parameter and changes in electric resistivity was investigated using artificially aged Cr-Mo-V steel. It is well understood that G parameter can be applied to electric: resistance techmique.

  • PDF

Study on EMTP Simulation Applying Dual Reactor for Prevention of the Ferro-resonance and VT Burnout in Substation System

  • Kim, Seok-kon;An, Yong-ho;Jang, Byung-tae;Choi, Jong-kee;Lee, Nam-ho;Han, Jung-yeol;Lee, You-jin
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.1-8
    • /
    • 2015
  • When the line and switchgear of the substation system are disconnected, ferro-resonance can occur. This happens even if the capacitive reactance and inductive reactance are not equal, which are not common resonance conditions. Resonance conditions vary depending on the busbar configuration environment. Although the damping resistance method applying the existing saturable reactor to cope with ferro-resonance has been successfully applied on site, there can be loss of normal function during long-term operation. The reason is because the rise in the operating frequency of saturable reactors means the saturation number is increased. Therefore, it can no longer function as saturable reactor since the resistor having inadequate capacity is burned out. To address this problem, in this paper, an EMTP-based simulation test was performed by designing and applying a dual reactor method, which adds an extended divergence reactor to the 1st side of the VT. The test result confirms that when the divergence reactor is inserted, the voltage and current values obtained at the 1st side and 2nd side of the VT as well as current values of divergence reactor part were stabilized from the transient phenomena and return to normal values. When compared with existing measures, although this method is similar in adding having a reactor added to a system regarding ferro-resonance, it has the advantage of being able to prevent ferro-resonance in advance since the reactor is added before the system is saturated. In addition, because it does not use damping resistance, it can extend the equipment life and stabilize its operation. Therefore, there are a lot of differences in terms of its operating characteristics and achivement of goal between the conventional method and new divergence reactor method.

Effect of geometry of underground structure and electrode on electrical resistance measurement: A numerical study

  • Tae-Young Kim;Hee-Hwan Ryu;Meiyan Kang;Suyoung Choi;Song-Hun Chong
    • Geomechanics and Engineering
    • /
    • 제39권1호
    • /
    • pp.105-113
    • /
    • 2024
  • Recently, electrical resistivity surveys have been used to obtain information related to underground structures including burial structure type and depth. However, various field conditions hinder understanding measured electrical resistance, and thus there is a need to understand how various geometries affect electrical resistance. This study explores the effect of geometric parameters of a structure and electrodes on electrical resistance in the framework of the finite element method. First, an electrical resistance module is developed using the generalized mesh modeling technique, and the accuracy of the module is verified by comparing the results with the analytical solution for a cylindrical electrode with conical tip. Then, 387 cases of numerical analysis including geometric parameters of a buried structure and electrodes are conducted to quantitatively estimate the detection depth under a steady-state current condition. The results show that electrical resistance is increased as (1) shallower burial depth of structure, (2) closer distance between ground electrode and structure, (3) longer horizontal electrode distance. In addition, the maximum detection depth corresponding to converged electrical resistance is deeper as (4) closer distance between ground electrode and structure, (5) shorter horizontal electrode distance. The distribution of the electric potential around the electrodes and underground structure is analyzed to provide a better understanding of the measured electrical resistance. As engineering purpose, the empirical equation is proposed to calculate maximum detection depth as first approximation.

As Te Ge Si 무정형 반도체의 온도영향 (A study of the effect of the temperature on the As Te Ge Si amorphous semiconductor)

  • 박창엽
    • 전기의세계
    • /
    • 제23권6호
    • /
    • pp.49-55
    • /
    • 1974
  • Amorphous semiconductor from As 30 Te 48 Ge 10 Si 12 was prepared, and studied electron microscopy, X-ray analysis and resistivity measurement. It's resistivity is 1.56*10$^{6}$ .ohm.-cm when small ampule is used for preparing sample it is found that no phase separation has occurced by electron microscopy, and that phase transition temperature is 232.deg. C by differential Thermal Analysis. The specimen showed threshold switching that the low resistance state occur at critical electric field and the resistance recover at low applied field. Critical electric field of the switching is 10$^{5}$ V/cm at room temperature. Threshold voltage secreace exponentially with increasing ambient temperature and at that each voltage resistance of the switching device increase exponentially. According to the series resistance and applied vottage current slope on the V-I curve is varied. When applied voltage is decreased after switching, the resistance of the switching device is increased. By this result the origin of the switching is the Joule's heating.

  • PDF