침전극 곡률반경에 따른 LLDPE/EVA의 교류트리 특성 (A Study on the AC Treeing Characteristics with Tip Radius of Needle Electrode in LLDPE/EVA)

  • 이재필;이충호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.476-480
    • /
    • 2003
  • Polyethylene used as insulating material of power cable is nonpolar and low dielectric loss polymer. But it has defects of tree generation and accumulation of space charge by an applied voltage resulting in the decreased life and performance. To solve these problems, mixed films with LLDPE and EVA that is similar to LLDPE at physical properties in case of low VA contents were made and tested due to the blend ratios of 80:20, 70:30, 60:40 and 50:50[wt%] respectively. We investigated AC electrical treeing characteristics to acquire the best mixture ratio and effect of the tip radius of needle electrode to develop excellent treeproof materials. The degree of crystallity calculated with XRD pattern is higher for pure LLDPE, 50:50 and 70:30. For DSC analysis, it is confirmed that the melting points of mixed specimens are lower than that of pure LLDPE and higher than pure EVA's. The shape of tree propagation showed that pure EVA was electrical tree shape of the branch type, pure LLDPE and blended specimens was able to confirm tree shape of the bush type. As the tip radius go up in the blend ratio 70:30 specimen, the tree inception voltage rise. Probably the reason is the relaxation of electric field in the specimen with bigger tip ratio. As the 6 specimens were applied AC 5[KV],7.5[KV],10[KV] respectively, tree growth length is far shorter in the specimen with blend ratio 70:30, 50:50 than in pure EVA and pure LLDPE specimen. Conclusively, it is confirmed that specimens of which blend ratio are 70:30 and 50:50 are good in electrical tree retardant characteristics, especially, 70:30 has lower dielectric loss than 50:50 and its mixture ratio is the best.

  • PDF

지중가온이 온실의 난방부하에 미치는 영향 (The Effect of Soil Warming on the Greenhouse Heating Load)

  • 남상운
    • 한국농공학회논문집
    • /
    • 제48권5호
    • /
    • pp.51-60
    • /
    • 2006
  • In order to examine the heat transfer characteristic of a soil warming system and effects of soil warming on the greenhouse heating load, control experiments were performed in two greenhouses covered with double polyethylene film. One treated the soil warming with an electric heat wire and the other treated a control. Inside and outside air temperature, soil temperature and heat flux, and heating energy consumption were measured under the set point of heating temperature of $5,\;10,\;15,\;and\;20^{\circ}C$, respectively. Soil temperatures in a soil warming treatment were observed $4.1\;to\;4.9^{\circ}C$ higher than a control. Heating energy consumptions decreased by 14.6 to 30.8% in a soil warming treatment. As the set point of heating temperature became lower, the rate of decrease in the heating energy consumptions increased. The percentage of soil heat flux in total heating load was -49.4 to 24.4% and as the set point of heating temperature became higher, the percentage increased. When the set point of heating temperature was low in a soil warming treatment, the soil heat flux load was minus value and it had an effect on reducing the heating load. Soil heat flux loads showed in proportion to the air temperature difference between the inside and outside of greenhouse but they showed big difference according to the soil warming treatment. So new model for estimation of the soil heat flux load should be introduced. Convective heat transfer coefficients were in proportion to the 1/3 power of temperature difference between the soil surface and the inside air. They were $3.41\;to\;12.42\;W/m^{2}^{\circ}C$ in their temperature difference of $0\;to\;10^{\circ}C$. Radiative heat loss from soil surface in greenhouse was about 66 to 130% of total heating load. To cut the radiation loss by the use of thermal curtains must be able to contribute for the energy saving in greenhouse.

태양광발전장치의 낙뢰보호 시스템 (Lightning Protection System of Solar Power Generation Device)

  • 윤용호
    • 한국인터넷방송통신학회논문지
    • /
    • 제23권2호
    • /
    • pp.157-162
    • /
    • 2023
  • 태양광발전 설비의 고장 중 서지에 의한 고장이 전체 고장률의 20% 차지하고 있으며 발전 중 수십에서 수백[A]의 에너지 방출과 인버터, 접속반 등의 전기적 손상은 전기안전사고로 이어지고 있다. 특히 낙뢰의 경우 전기회로에 이상 전압이 유기되어 절연을 파괴할 뿐만 아니라 이때 흐르는 전류는 화재의 원인이 되고 부품의 열화를 촉진하는 요인으로 작용한다. 이러한 작용으로 도심 밖에서 주택, 아파트, 관공서 등의 도심 내부로 확산하고 있는 태양광 발전장치의 전기 안전 문제가 대두되고 있다. 낙뢰는 필드 기반 및 전도성 전기 간섭을 유발하기에 이 효과는 케이블 길이 또는 도체 루프 증가와 관련하여 증가한다. 또한 서지는 태양광 모듈, 인버터 및 모니터링장치뿐만 아니라 건물 설비의 장치도 손상하기에 최종적으로는 태양광발전시스템의 화재로 인한 운영 중단과 이에 따른 재정손실을 유발하게 시킬 수 있다. 따라서 본 논문에서는 태양광발전시스템의 낙뢰발생으로 인한 화재 및 전기안전사고 증가로 인하여 재산피해 및 인명피해를 줄일 수 있는 목적으로 태양광발전장치의 낙뢰보호 시스템을 연구하고자 한다.

CS졸을 이용한 Poly(epoxy-imide)-나노 Silica 하이브리드 필름의 합성과 유전특성 (Synthesis of Poly(epoxy-imide)-Nano Silica Hybrid Film via CS Sol-gel Process and Their Dielectric Properties)

  • 한세원;한동희;강동필;강영택
    • 한국전기전자재료학회논문지
    • /
    • 제20권1호
    • /
    • pp.35-40
    • /
    • 2007
  • The new PEI(poly(epoxy-imide))-nano Silica film has been synthesized via in situ CS sol process, and the chemical bonding and microstructure of nano silica dispersed in resin were examined by FT-IR, TAG and SEM. The dielectric properties of these hybrid films over a given temperature and frequency ranges have been studied in a point of view of stable chemical bonding of nano Silica filler. The results from IR spectra and SEM photograph indicated that PEI-Silica hybrid film prepared with nano CS sol process has been synthesized in uniform and chemical bonding. The decrease property of dielectric constant with CS content, tangent loss consistent of given frequency and temperature has been explained in terms of the chain movement of polymer through chemical bonging and size effect of nano silica. The new PEI-CS sol hybrid film with such stable chemical and dielectric properties was expected to be used as a high functional coating application in ET, IT and electric power products.

Analysis of Effects on the performance of ceramic metal halide lamp by the loss of elements that have been filled in arc tube

  • 장혁진;양종경;이종찬;김우영;신익태;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.219-219
    • /
    • 2009
  • ceramic metal halide lamps are a subset of high intensity discharge lamps so named because of their high radiance These lamps weak ionized plasma in a fire-resisting but light transmissive wrapping by the corridor of current through atomic and molecular vapors. for commercial applications, For commercial applications, the conversion of electric power to light must occur with good efficiency and with sufficient spectral content throughout the visible (380-800 nm) to permit the light so generated to render colors comparable to natural sunlight. the purpose of this paper is to carry out a study on the variation of ageing time(2000 On/Off[hr]) on the performance of 150W CMH lamps. Experimental results show that the blackening by reacting W(tungsten)with I atomic has been created in the arc tube of an ageing lamp(2000 On/Off[hr]), the arc was unstable, and increased a lamp resistance made lamp voltage increases significantly. Also, Color temperature of the ageing lamp was moved by the losses of Ho with Dy atomics and by recombination of Na with I.

  • PDF

몰드변압기의 공기덕트의 구조 변화에 따른 온도특성 해석 (Analysis of Temperature Characteristic According to Variation of Air Duct of the Cast Resin Transformer)

  • 김지호;이향범;손진근
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.256-260
    • /
    • 2015
  • In this paper, achieved rise temperature distribution about degradation phenomenon of 24 MVA distribution cast resin transformer using CFD(Computational Fluid Dynamics). Usually, life of transformer is depended on temperature distribution of specification region than thermal special quality of transformer interior. Specially, life of transformer by decline of dielectric strength decreases rapidly in case rise by strangeness transformer interior hot spot temperature value permits. Because calculating high-voltage(HV) winding and low-voltage(LV) winding of cast resin transformer and Joule's loss of core for improvement these life, forecasted heat source, and HV winding and LV winding of cast transformer rise temperature distribution of core for supply of electric power and temperature distribution of highest point on the basis of the results. Also, calculated temperature rise limit of cast resin transformer and permission maximum temperature using analysis by electromagnetic heat source. Calculated and forecasted rise temperature distribution by heat source of thermal analysis with calculated result.

다우비시 웨이브릿 변환의 상세계수 비율을 이용한 교류발전기의 내부고장 검출 및 고장종류 판별 (Internal Fault Detection and Fault Type Discrimination for AC Generator Using Detail Coefficient Ratio of Daubechies Wavelet Transform)

  • 박철원;신광철;신명철
    • 전기학회논문지P
    • /
    • 제58권2호
    • /
    • pp.136-141
    • /
    • 2009
  • An AC generator is an important components in producing a electric power and so it requires highly reliable protection relays to minimize the possibility of demage occurring under fault conditions. Conventionally, a DFT based RDR has been used for protecting the generator stator winding. However, when DFTs based on Fourier analysis are used, it has been pointed out that defects can occur during the process of transforming a time domain signal into a frequency domain one which can lead to loss of time domain information. This paper proposes the internal fault detection and fault type discrimination for the stator winding by applying the detailed coefficients by Daubechies Wavelet Transform to overcome the defects in the DFT process. For the case studies reported in the paper, a model system was established for the simulations utilizing the ATP, and this verified the effectiveness of the proposed technique through various off-line tests carried out on the collected data. The propose method is shown to be able to rapidly identify internal fault and did not operate a miss-operation for all the external fault tested.

압전층의 2단 증착법을 이용한 체적 음향파 박막형 공진기의 제작과 성능향상에 관한 연구 (A Study of the Fabrication and Enhancement of Film Bulk Acoustic Wave Resonator using Two-Step Deposition Method of Piezoelectric Layer)

  • 박성현;추순남;이능헌
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권7호
    • /
    • pp.308-314
    • /
    • 2005
  • The 2 GHz film bulk acoustic wave resonator(FBAR), one of the most necessary device of the next generation mobile communication system, consisted of solidly mounted resonator(SMR) structure using Brags reflector, was researched in this paper The FBAR applied SiO$_{2}$ and W had large difference of the acoustic impedance to reflector Al to electrode and ZnO to piezoelectric layer. Specially, the FBAR applied the two-step deposition method to improve the c-axis orientation and increase reproducibility of the fabrication device had good performance. The electrical properties of plasma such as impedance, resistance, reactance, $V_{pp},\;I{pp}$, VSWR and phase difference of voltage and current, was analyzed and measured by RF sensor with the variable experiment process factors such as gas ratio, RF power and base vacuum level about concerning the thickness, c-axis orientation, adhesion and roughness. The FBAR device about the optimum condition resulted reflection loss(S$_{11}$) of -17 dB, resonance frequency of 1.93 GHz, electric-mechanical coefficient(k$_{eff}$) of 2.38 $\%$ and Qualify factor of 580. It was seen better qualify than the common dielectric filter at present and expected on business to the filter device of 2 GHz bandwidth with the MMIC technology.

중앙식 냉방 플랜트의 유량제어를 통한 에너지 절감에 관한 연구 (Flow Control of a Centralized Cooling Plant for Energy Saving)

  • 이정남;김영일;정광섭
    • 에너지공학
    • /
    • 제24권3호
    • /
    • pp.48-54
    • /
    • 2015
  • 중앙집중식 냉방 시스템을 적용하고 있는 대형 빌딩이나 플랜트 설비들의 경우 부하 증설 및 피크부하에 대응하기 위한 여유율을 반영한 설비 설계 및 시공이 이루어지고 있다. 이는 부분부하가 걸리는 기간 동안에는 설비의 저부하 운전으로 인한 장비의 효율 저하와 에너지 과소비의 원인이 된다. 본 연구는 부분부하에 효율적으로 대응할 수 있도록 냉방플랜트 최적 유량제어를 통한 에너지 절감 방안에 대한 연구로서 냉방플랜트 에너지 성능 분석 프로그램을 이용하여 냉방 부하를 분석하고, 최적 유량제어 시스템을 제안하여 그 에너지 성능을 비교 평가하는 것을 목적으로 한다. 성능 분석 결과 냉방플랜트 최적 유량제어 시스템 적용 시 기존 에너지 사용량 대비 약 17%의 전기에너지 절감이 가능하였다.

전기안전관리대행 제도의 합리적 운영 방안 (Reasonable Operation Method for Electrical Safety Management Agency System)

  • 김두현;김성철;이종호;김선구;황광수;김상철
    • 한국안전학회지
    • /
    • 제27권1호
    • /
    • pp.14-19
    • /
    • 2012
  • This study proposes to suggest a direction hereafter which is the most suitable operating system of electrical safety management agency for electrical facilities to enhance electrical safety considering our domestic conditions. It was designed to prevent electrical disasters which are increasing due to environmental changes in the electrical industry, and the diversification and complication of the electrical facilities. And the strategy of this research is based on conditions of safety management agency for the electrical facilities, with the analysis on conditions of electrical disasters, and with a questionnaire investigation for owner of electrical facilities, safety management agency. Results of this research are expected to be used to prevent electric fires and shocks effectively by reinforcing the electrical safety management agency of electrical facilities having danger of large-scaled accidents. It is expected to enhance the nation's competing power against foreign countries by reducing the human and physical loss, resulted from the development of reasonable operating system for electrical safety management agency.