• 제목/요약/키워드: Electric power facilities

검색결과 514건 처리시간 0.029초

고압전동기 절연진단 결과 추이관리의 문제점 분석 (Analytic Issues for Trend Management on Insulation Diagnositic for High Voltage Motors)

  • 이영준;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2052-2053
    • /
    • 2008
  • High voltage motors are the core equipment of electric generation facilities and need to guarantee stable operation. Therefore, keeping healthy state is of importance by means of insulation diagnosis periodically. However, if the diagnosis went through in the different circumstances such as temperature, humidity, and impedance applied to the test equipment, the trend analysis have no significance. This paper presents the experimental results supporting the importance of keeping the same conditions under insulation diagnosis.

  • PDF

실시간 계측시스템을 이용한 전차선로 특성 측정 (Characteristic Measurement by a Real-time Data Acquisition System in Overhead Contact Wire)

  • 나해경;박영;조용현;이기원;박현준;오수영;송준태
    • 한국전기전자재료학회논문지
    • /
    • 제20권3호
    • /
    • pp.281-285
    • /
    • 2007
  • Facilities of electric railway should be maintained only at night and it is necessary to maintain by human power because facilities are installed at a high place. This paper presents the development and application of a real-time data acquisition system for the characteristics measurement of overhead contact wires in electric railway. The system is designed to perform in the telemetry environments that developed to store data by wireless in a live wire state of 25 kV power source. The field test results show that the proposed technique and the developed system can be practically applied to measure characteristics of temperature, displacement, and strain on overhead contact lines.

남대천 양양 양수발전소의 환경영향과 대책 (Environmental Impact Assessment of the Yangyang Pumped Storage Power Plant Construction on the Namdae-Chun River, Korea)

  • 전상기
    • 환경영향평가
    • /
    • 제6권1호
    • /
    • pp.151-160
    • /
    • 1997
  • The Yangyang Pumped Storage Power Plant is being constructed by Korea Electric Power Corporation in Namdae-Chun River, Korea. The Yangyang Pumped Storage Power Plant has 1000MW capacity with upper reservior, lower reservior, hydrauric tunnel and underground power plant facilities. But NGO(Non Governmental Groups) and residents are worried about the power plant construction because of some problems, as follows. (1) Namdae-Chun River is principal salmon returning river in Korea. (2) Namdae-Chun River is main water supply source of the Yangyang country. So, brief explanation of Environmental Impacts Assessment executed by Korea Electric Power Corporation, main environmental impacts and countermeasures will be introduced.

  • PDF

Double-Input DC-DC Converter for Applications with Wide-Input-Voltage-Ranges

  • Hu, Renjun;Zeng, Jun;Liu, Junfeng;Yang, Jinming
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1619-1626
    • /
    • 2018
  • The output power of most facilities for renewable energy generation is unstable due to external environmental conditions. In distributed power systems with two or more sources, a stable output can be achieved with the complementary power supply among the different input sources. In this paper, a double-input DC-DC converter with a wide-input-voltage-range is proposed for renewable energy generation. This converter has the following advantages: the circuit is simple, and the input voltage range is wide and the fault tolerance is excellent. The operation modes and the steady-state analysis are examined. Finally, experimental results are illustrated to verify the correctness of the analysis and the feasibility of the proposed converter.

검침데이터 기반의 시간대별 설비부하 분석 및 시뮬레이션 모델 개발 (Development of Time-series Load Analysis and Simulation Model for Power Facilities based on Meter Reading Data)

  • 신진호;이봉재;김영일;송재주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1848-1849
    • /
    • 2007
  • 배전계통과 설비의 부하분석은 계측장치에 의존하여 왔으며, 대규모인 배전설비의 부하감시는 막대한 설치 및 유지보수 비용이 수반된다. 본 논문에서는 계측장치를 설치하지 않고도 정기적으로 취득되는 고객의 검침데이터를 이용하여 배전설비의 시간대별 부하분석 및 시뮬레이션을 수행할 수 있는 모델을 개발하고, 그 과정 및 결과를 제시한다. 이 모델은 고압고객의 원격검침 및 저압고객의 월검침 데이터를 구간계통에 적용하고 조류계산을 수행하여 15분 단위로 회선이하 구간 및 변압기의 부하를 분석할 수 있다. 또한, 특정 시점의 부하를 증감시키거나 다른 설비로 전환하여 시간대별 부하가 어떻게 변화하는지 시뮬레이션을 수행할 수 있다.

  • PDF

천연가스 사용설비 오염물질 배출특성 연구 (A Study on Characteristics of Pollutants from LNG Facilities)

  • 이중성;이현찬;유현석;한정옥
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제28회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.223-226
    • /
    • 2004
  • The thesis examined the charactcri:stlC of pollutants exhausted from LNG facilities. So, combustion gas and concentration of greenhouse gas exhausted from gas boiler for home use, furnace facilities, electric power facilities, boiler for industrial use and boiler for heating fueled LNG is measured. And the exhaust factor of pollutants is produced by classify of pollutants in detail. And this exhaust factor is compared and investigated with data of a foreign nations.

  • PDF

Revenue Maximizing Scheduling for a Fast Electric Vehicle Charging Station with Solar PV and ESS

  • Leon, Nishimwe H.;Yoon, Sung-Guk
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권3호
    • /
    • pp.315-319
    • /
    • 2020
  • The modern transportation and mobility sector is expected to encounter high penetration of Electric Vehicles (EVs) because EVs contribute to reducing the harmful emissions from fossil fuel-powered vehicles. With the prospective growth of EVs, sufficient and convenient facilities for fast charging are crucial toward satisfying the EVs' quick charging demand during their trip. Therefore, the Fast Electric Vehicle Charging Stations (FECS) will be a similar role to gas stations. In this paper, we study a charging scheduling problem for the FECS with solar photovoltaic (PV) and an Energy Storage System (ESS). We formulate an optimization problem that minimizes the operational costs of FECS. There are two cost and one revenue terms that are buying cost from main grid power, ESS degradation cost, and revenue from the charging fee of the EVs. Simulation results show that the proposed scheduling algorithm reduces the daily operational cost by effectively using solar PV and ESS.

전력계통(電力系統) 기상정보(氣象情報)시스템의 도플러레이다 위치(位置) 선정(選定) (Doppler Rader Location of Weather Information System for Power System Operation)

  • 김영한;이효상;김재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.206-210
    • /
    • 1989
  • With the economy expands and the increasing living standard of people, the better quality of electricity which is closely related with weather conditions should be supplied to the customers especially using precised facilities. In this paper, the configuration of the weather information system and its application to the power system operation are generally introduced. And also, a method with test result is presented to find the suitable radar coverage area including the condition of electromagnetic wave shut off.

  • PDF

XLPE 절연체의 등가 및 가변온도 가속열화실험을 통한 기계적 특성 비교 분석 (A Comparison Study on Mechanical Properties of XLPE Insulation Thermally Degraded at Equivalent and Variable Temperature Conditions)

  • 김태준;황재상;정성훈;김태영
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.73-77
    • /
    • 2022
  • Recently, as the number of years of operation has increased for more than 30 years, interest in evaluating the remaining life of major power facilities such as transformers and ultra-high voltage cables is increasing. In particular, the risk of failure is increasing because the underground transmission XLPE cable has been built since 1980 and has been operating in excess of 30 years of design life or close proximity. Therefore, it is necessary to develop an algorithm to evaluate the residual life of the XLPE cable considering the load to determine the risk of failure. Since load data is large amount of data, it is necessary to make the variable load information equivalent to the time unit first in order to calculate the remaining life of the system quickly. In overseas literature, transformers are reported to be standardized for variable load equivalent conversion formulas, but they have not been reported for ultra-high voltage cables. Therefore, in this paper, whether the equivalent conversion formula of a transformer can be applied to XLPE cables was reviewed through accelerated degradation tests under equivalent and variable temperature conditions, and considerations were studied when evaluating the remaining operating life of XLPE cables based on the experimental results.

배전 변압기의 통계적 기대 수명 평가 및 초기 고장제거 적정성 검토 (Distribution Transformer Statistical Expected Life Evaluation and Removal Adequacy Review)

  • 조종은;김상봉;이온유;김강식
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.79-86
    • /
    • 2022
  • Recently, the amount of maintenance is increasing due to the aging of power facilities, but the budget is constrained. Therefore, the importance of asset management that selects replacement priorities based on the failure probability and enhances investment effects is increasing. Because the number of distribution transformers is very large, the proportion of investment cost is very high. Therefore, it is important to select the investment priority by evaluating the reliable remaining life based on the failure probability. This paper evaluates the statistical expected life using the failure data of distribution transformers for the last 11 years and the current operation data. The hazard rate of distribution transformer and MV cable was compared with each other and the adequacy of early failure removal was reviewed and the statistical expected life corresponding to the cumulative failure probability B3% was calculated.