• 제목/요약/키워드: Electric power equipments

검색결과 218건 처리시간 0.101초

수력발전소 자동제어설비 시험용 신호변환장치 개발에 관한 연구 (A Study on Development of Signal Conditioner for Test of Automatic Control Equipments in Hydro Power Plant)

  • 변두균;장문성;김주현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.169-171
    • /
    • 1995
  • Automatic control equipment in hydro power plant, such as turbine governor or automatic voltage regulator have to act promptly against for variation of power system, so it is necessary to check and test continuously. During last five years, the performance test of automatic control equipment was performed about 20 units of hydro turbine generator. In this process, because it has complex connection and before calibration, signal conditioner was developed as an auxiliary equipment for performance test. It includes function of signal amplifier, transducer, and meters. As a result of use this equipment for electric governor test at soyang-gang hydro power plant, it was possible to find output data equal to old one.

  • PDF

국내 무연탄 발전소 혼소율 변화에 따른 탈황 특성 연구

  • 김정유;박대영;이재헌;문승재
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.84-87
    • /
    • 2008
  • The sulfur oxides is one of important materials to come about air pollution at thermal plant consuming fossil fuel. The several flue gas desulfurization equipments are installed and operated to decrease sulfur oxides. The flue gas desulfurization of our thermal plant is designed for optimizing flue gas desulfurization technical development and research by Korea Electric Power Research Institute. We operate this desulfurization equipment. Now, our country imports nearly 97 percentage of the energy source and competes with the world for the energy because of the rise of raw materials cost. The fuel cost decrease of power plants is the most important factor of the operation. The fuel used in the experiment is the domestic anthracite from Kangwon Taeback and the bituminous coal from Russia,Taldinsky Mine. This Study is experimental investigations of desulfurization characteristics for domestic anthracite power plant by increasing bituminous coal. We surveyed possible parameters and conducted the performance about desulfurization equipment in Y.D thermal power plant.

  • PDF

Preventing Method against the Occurrence of a Corona between a Dead End clamp and a Porcelain Insulator Used in 154kV Substation

  • Han, Woon-Ki;Choi, Jong-Soo;Lee, Jun;Kim, Jae-Chul
    • International Journal of Safety
    • /
    • 제6권2호
    • /
    • pp.22-26
    • /
    • 2007
  • An episode of corona is a heterogeneity-caused electric discharge that occurs when electric fields are formed layer on layer and concentrated on an electrode. Electric wires built at the tip of 154kV private facilities use dead end clamp spawns corona from homogeneity caused by field concentration. Corona induces power loss, noise, insulator failure and more. In this research, we've studied the characteristics of coronas that take place in porcelain insulators and terminal electric wires of supporting hard wares (dead end clamp) that are set up as spares in the 154kV private facilities use hydroelectricity installations to support electric wires. Corona, which cannot be identified by regular methods, was measured utilizing UV image camera. As the result of measuring corona via UV image camera, we've confirmed that the depletion of insulators was accelerated following the wire end treatment method and validated the stress intensity of insulators at various lengths of bare wires caused by electric fields via FEMLAB. We have also proposed a new model for relieving homogeneity-caused field concentration, and after analyzing the proposed model via FEMLAB, we've confirmed that the concentration of field distribution was indeed reduced. Such results are exploited in installation of private facilities use equipments, maintenance of insulators and hard wares as well as safety enhancement, and are anticipated to be effectively utilized in corona prevention measures.

고전압 실험실에서 시변성 전자계의 특성 (Characteristics of Time-Changing Electric and Magnetic Fields at a High Voltage Laboratory)

  • 이복희;이경옥;안창환
    • 한국전자파학회논문지
    • /
    • 제8권1호
    • /
    • pp.83-93
    • /
    • 1997
  • 본 논문은 고전압 실험실에서 시변성 전자계의 측정 및 평가에 관한 것으로 전자적 외란은 주로 전력장비의 지락고장 및 개폐조작에 의해 기인되며, 전자회로와 제어장비틀은 전자방해작용에 매우 민감하다. 주어진 전자환 경에 대한 전자방해작용의 레벨을 평가하는 것은 필수적이다. 전계는 40 Hz-2oo MHz 범위의 대역폭을 갖는 전계센서로 관측되었으며, 시변성 자계는 출력이 입사신호에 직접적으로 비례하는 루프형 센서로 측정되었다. 또한 진동성 과도전류와 차단파 임펄스전압에 의해 유도된 전자방해작용의 레벨파 전자 차폐의 외함설계에 관한 정보를 주는 사변성 전자계의 주파수 성분을 고속프리에변환으로 분석하였다.

  • PDF

ESS 이동형 시험장비용 운영시스템의 개발과 모의검증 (Development and Simulation Verification of Operation System for Mobile ESS Test Equipment)

  • 신제석;한현규;김진태;이승민;박찬욱;임건표
    • 전기학회논문지P
    • /
    • 제67권3호
    • /
    • pp.168-174
    • /
    • 2018
  • The performance test for 376MW ESS for frequency regulation currently operating in 13 substations is conducted based on the test procedure in the first and second steps. In the first step, components of ESS is moved to the certification authority where the test equipment is located in order to be proceeded with the test. In the second step, the performance test is conducted manually for the ESS equipments installed on site using the movable measurement equipment, and thus it can only be performed on some limited test items and requires a lot of time and manpower. Therefore, mobile test equipment for ESS(MOTES) is being developed that can perform automatically more test items for ESS in the field using the MOTES, and reduce manpower and time. To do this, an algorithm and a prototype of the operating system(MOS) are also being developed that can control MOTES automatically. In this paper, a development of the MOS prototype is introduced and then a simulation is performed to verify the prototype and its algorithm before the field demonstration.

수소를 냉각매체로 하는 발전기 안전대책에 관한 연구 (A Study on the safety measures for the protection of hydrogen cooling system of generator)

  • 이춘하;육현대
    • 한국가스학회지
    • /
    • 제8권4호
    • /
    • pp.55-61
    • /
    • 2004
  • 본 논문에서는 발전소의 발전기 냉각시스템에서 수소를 사용하므로써 발생가능한 문제점에 대한 안전대책에 관하여 언급하였다. 수소가스는 가연성 기체중 폭발범위가 대단히 크므로 이에 따른 안전대책을 강구해야 하며, 이것은 전력설비의 안정적인 운영을 위해서도 중요한 일이다. 본 연구에서는 1) 수소의 연소폭발재해와 관련된 기술적 지침을 제공함; 2) 운영환경의 위험수준에 따라 위험장소 구분하고 그에 따른 방폭전기설비의 채용; 3) 가스누설검지장치 설치 등 수소로 인한 재해를 미연에 방지할 수 있는 대책 및 기준 마련; 4) 발전소 정상운전중 안전관리체계를 정립하여 발전소 수소가스설비관련 안전관리의 표준모델을 제시하고자 하였다.

  • PDF

전자환경 측정에 의한 방전전류 파형추정과 절연진단의 기초 연구 (A Basic Study on the Estimation of Discharge Current Waveform and the Insulation Diagnosis by the Measurement of Electromagnetic Environment)

  • 박광서;김기채;김이국;박원주;이광식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권10호
    • /
    • pp.492-499
    • /
    • 2002
  • This paper presents the method for an estimation of discharge current waveform in short gap discharge by radiated electromagnetic fields. The method of current waveform estimation is to use the one antenna method (single field method) with a measured electric or magnetic field at given field point by a time domain antenna. In order to verify the availability of the estimation theory, the discharge current waveform estimation was performed by one antenna methods using the measured electric fields of Wilson & Ma and compared with experiments. In addition diagnosis technique for power equipments is able to prevent from large accidents by finding signs of tile accidents before they happen. From the results of the estimation of discharge current, we have a possibility for the application of insulation diagnosis technique for power equipments using S$F_6$ gas. From this point of view, this paper simulated discharge progress and partial discharge by using needle-plan electrodes system in S$F_6$, studied the distribution of frequency spectrum of the radiated electromagnetic waves using a biconical antenna and a spectrum analyzer. From the experimental results of this study, according to the consideration of the mutual relation between frequency spectrum of the radiated electromagnetic waves and discharge progress, it was confirmed that detecting Partial discharge and estimating discharge progress in S$F_6$ could be Possible.

속도 및 제어시스템의 부조화에 따른 조속기 에러 원인 분석 (The Analysis about Trouble of GOVERNOR)

  • 옥연호;오석영;김기원;변일환;고영환;임승현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.252-253
    • /
    • 2011
  • Many errors are broken out when hydro power plants are operating connected to electric power system. To minimize ripple effects of accidents, a hydro power plant is separated by a circuit breaker consisting of each protection equipments. In this paper, I will analyze a cause of abnormal events of emergency stop and therefore I take measures and suggest solutions for similar cases.

  • PDF

전력사용설비의 에너지 절감방안 및 관리를 위한 진단기법 (Techniques of Management and Energy saving by using power installation)

  • 정춘병;전기영;함년근;김대균;이상집;오봉환;이훈구;한경희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.329-333
    • /
    • 2004
  • The human beings have increased concern about Energy saving and alternative energy. The power demand has increased the growth of industry and the improvement of life. We have to explore alternate energy sources and utilize effectively domestic resources. The lighting equipments developed Energy saving by using an electric ballast. The load installation should be promoted to rational power management, according to the network, inteligent, and high-function. Therefore, this paper has studied the method of energy saving and consulting.

  • PDF

전력 설비 진단을 위한 무선 센서의 응용 (Application of Wireless Sensor for Diagnostics of Electric Equipments)

  • 윤주호;최용성;황종선;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2112-2113
    • /
    • 2008
  • The concept is based on distributed wireless sensors that are attached to the incoming and outgoing power lines of secondary substations. A sensor measures only phase current characteristics of the wire it is attached to, is not synchronized to other sensors and does not need configuration of triggering levels. The main novelty of the concept is in detecting and locating faults by combining power distribution network characteristics on system level with low power sampling methods for individual sensors. This concept enables the sensor design to be simple, energy efficient and thus applicable in new installations and for retrofit purposes in both overhead and underground electrical distribution systems.

  • PDF