The Analysis about Trouble of GOVERNOR
속도 및 제어시스템의 부조화에 따른 조속기 에러 원인 분석
- Ok, Yeon-Ho (Korea Water Resource Corporation) ;
- Oh, Sueg-Young (Korea Water Resource Corporation) ;
- Kim, Ki-Won (Korea Water Resource Corporation) ;
- Byun, Ill-Hwan (Korea Water Resource Corporation) ;
- Go, Young-Hwan (Korea Water Resource Corporation) ;
- Im, Seung-Hyun (Korea Water Resource Corporation)
- Published : 2011.07.20
Abstract
Many errors are broken out when hydro power plants are operating connected to electric power system. To minimize ripple effects of accidents, a hydro power plant is separated by a circuit breaker consisting of each protection equipments. In this paper, I will analyze a cause of abnormal events of emergency stop and therefore I take measures and suggest solutions for similar cases.
Keywords