• 제목/요약/키워드: Electric power equipments

검색결과 218건 처리시간 0.028초

배전설비의 환경조화방안 (A plan to harmonize the equipments of power distribution with its environment)

  • 이재관;김상률
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1206-1209
    • /
    • 1998
  • For 21th Century, the assignment of power distribution will be the expansion of equipments to supply electric power and harmony with its environment, in process of approving value consciousness of land, space, and the preservation of surroundings. This paper proposes a plan to match with the requirement about equipments, having ability to supply electric power, being harmonized itself with its surroundings by applying a general concept of "Amenity" when we choose an established form of power distribution.

  • PDF

지하구내 침수시 감전 방지대책 수립을 위한 전기설비 설치 및 관리실태 조사 (An Investigation Into the Actual Condition of Electrical Equipments Installation and Management for Establishing the Countermeasures Against the Electric Shock in Submerged Underground)

  • 정진수;정종욱
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.84-90
    • /
    • 2008
  • This paper describes the investigation into the actual condition of electrical equipments installation and management for establishing the countermeasures against the electric shock in submerged underground. The investigation was carried out for 27 underground premises in conurbation including Seoul, and potential of the exposed electrical equipments negatively affecting on human safety when disaster occurs was measured. The objects to which measurement was carried out were as follows; electrical source; advertising lighting; power equipment. As a result, it was confirmed that potentials more than 230[V] were induced in some equipments. In addition, the electrical equipments installed in most conventional underground premises were left unmanaged.

순간전압강하에 대한 비선형 저압전기기기의 동적특성 (A Dynamic Characteristics on Non-linear Voltage Electric Equipment under Voltage Sag)

  • 이현철;정성원;김재현;이근준
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.336-343
    • /
    • 2008
  • In this study, a transition of power quality was characterized by non-linear voltage electric equipments under voltage sag. The test was inputted voltage sag to IPC(Sag Generator) from AVR, and then to equipments by IPC which adjust voltage magnitude and duration. The load test which non-linear voltage electric equipments used PLC, Magnetic Contactor, SMPS, HID Lamp. The test result was different from each other according to a manufacturing companys, models, and equipments. PLC was greatly described to be stabilized voltage sag in case of no load then rated load. Magnetic Contactor was made a difference to phase angles on voltage sag, which was $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$. HPD Lamp was described to be stabilized the sodium lamp, and to be unstabilized the metal hailed lamp. The test result was showed CBEMA curve that stand for evaluated responsiveness of voltage sag. This study was tested description to dynamic characteristics on non-linear voltage electric equipment under voltage sag. There was hoped that power system designed the essential particulars.

적외선 열화상 카메라를 이용한 수전설비 온도분포해석 (The Analysis of Temperature Distribution Electric incoming Apparatus Using a Infrared Thermal Imaging System)

  • 정승천;임용배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1113-1116
    • /
    • 2004
  • This paper presents the method for analyzing surface temperature of Electric incoming Apparatus. For the experiment, the surface temperature of electric power apparatus was measured and analyzed by using a infrared thermal imaging system. Surface Discharges(SD) have very complex characteristics of discharge patterns, therefore it requires the development of precise analysis methods. recently, studies on infrared thermal imaging system are carried out to analyze temperature distribution of power equipments through condition diagnosis and to diagnose the degradation of power equipments. The changes in suface temperature was measured by using the infrared thermal imaging system under hot line condition. The system was set up based on the diagnostic method of the electric incoming apparatus.

  • PDF

음향방출기술에 의한 발전설비 비파괴검사 및 응용 (Nondestructive Testing and Applications for Electric Power Plant Equipments by Acoustic Emissin Technology)

  • 이상국
    • 비파괴검사학회지
    • /
    • 제24권4호
    • /
    • pp.396-409
    • /
    • 2004
  • 음향방출기술(acoustic emission technology)은 종래의 기존 비파괴검사법과는 달리 가동중인 설비의 건전성을 평가할 수 있으며 실시간으로 설비 상태의 진단이 가능한 실시간 감시기법이다. 즉 기존 비파괴검사법과는 달리 가동중인 설비에 대해 원격으로 결함을 탐지하고 결함 위치를 판정할 수 있는 연속감시 기능을 가진 비파괴 신기술로 최근 연구개발이 활발히 진행되고 있는 방법이다. 이러한 장점 때문에 대형 산업설비의 각종 기기들에 대한 감시 및 진단에 활용하고 있으며, 그 활용도가 점점 확대되고 있는 추세에 있다. 특히 종합적인 산업설비로 구성되어 있는 발전설비의 진단과 감시에 가장 효과적인 방법이라 할 수 있겠다. 본 논문에서는 원자력 화력 수력발전소 등의 발전설비에 대해 현재 적용중인 음향방출기술과 새로운 적용기술에 대해 서술하였다.

하이브리드 자동차용 고압 케이블의 온도 특성에 관한 연구 (A Study on the Temperature Characteristics of High Voltage Power Cable for Hybrid Electric Vehicle)

  • 이기연;김동우;김동욱;길형준;김향곤;최충석
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.338-342
    • /
    • 2008
  • Hybrid Electric Vehicle(HEV) is driven by an internal-combustion engine and an electric motor. It is a combination of an internal-combustion engine and several electrical equipments which use a high voltage battery, an electric motors, an inverter and others. But there is not any separate detailed enforcement regulations for high voltage electric appliances in the existing vehicle-related safety standards. So, test standards suggestion as well as test technique development need to be done for ensuring electrical safety, for an electric motor, a high voltage battery, a(n) inverter/converter and an electric power transmission units and other equipments to ensure the safety of high voltage electric appliances which is the HEV key electrical component. In this paper, We are to provide helpful data to support test technique development and test standard establishment for HEV design and electrical safety security by the following methods; by measuring the voltage, the electric current, and the frequency of HEV, by analyzing electrical characteristics of high voltage electric appliances, and by analyzing temperature characteristics of the electrical current among the analyzed electrical characteristics by thermal imagining cameras.

고속철도내 자기장에 의한 인체 모델에서의 유도 전류 계산 (Induced Current Calculation in a Human Body Model due to Magnetic field in High Speed Railway)

  • 한인수;이태형;박춘수;김기환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.208-213
    • /
    • 2008
  • In recent society, the quality of human life has improved due to the use of electric appliances and the high powered electrical equipments. However, lots of electric appliances and equipments generate the electromagnetic field hazard. Many studies have been made about the wrong behavior of machines due to electromagnetic fields, the interferences in communication equipments, the possibility of the electromagnetic field hazard in human body, etc. There exist international standards about the RF equipments (ex. mobile phone, antenna, etc.). But, many researchers involved in power frequency electric and magnetic field only propose the prudential avoidance. In this paper, induced currents in a human body model due to magnetic fields in high speed railway are calculated by two dimensional impedance method. Power frequency(60Hz) magnetic fields are calculated and induced currents are simulated by Faraday's law. Induced currents are simulated with induced voltage, human body model impedances due to Ohm's law, magnetic fields derived from Biot-Savart's law and Transmission Line Method in high speed railway.

  • PDF

발전설비용 소화시스템의 성능 예측을 위한 CFD기법 적용 연구 (Application of CFD Method to Performance Prediction of Fire-Suppression System for Electric Power Utilities)

  • 정희택;배강열;김찬희;정인수;배진수;한용식;김종진
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.296-299
    • /
    • 2008
  • In the present research, the exclusive analysis system based on the CFD method were suggested to predict the fire-suppression performance of water mist fire-suppression equipments for design applications. The computing scope is ranged from starting pump to fire-suppression equipments, composed of three parts that calculation of flow rate and pressure distribution at each nozzle, examining of spray performance and predicting of fire-suppression performance in the fire space. Application were done to the fire-suppression system for electric power generation plants. The results were analyzed by comparison between numerical results and initial design conditions in terms of thermal and fluid mechanics.

  • PDF

전력 케이블의 열화진단 (DIAGNOSIS OF DETERIORATION FOR HIGH VOLTAGE CABLE)

  • 최창수;김영;김장원;김영남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1353-1355
    • /
    • 1995
  • While the modern society has been highly diversified and civilized, the demand for the safty of a power transmission has been greatly increased. For the underground cable, the performance of the electrical equipments is being improved by developing a new technology, and the reliability of the power supply is being up graded by impressing the diagnostic and monitoring technology of the system. In this paper the aging procedure of O.F and XLPE cables are described, including the diagnostic and monitoring equipments and the future subject.

  • PDF

전력설비 피해 감소를 위한 지능형 재폐로방식에 관한 연구 (Intelligent Reclosing Scheme to reduce a Damage of Power Equipments)

  • 임성정;김재철
    • 조명전기설비학회논문지
    • /
    • 제15권1호
    • /
    • pp.112-117
    • /
    • 2001
  • 본 논문은 전력설비 피해 감소를 위한 배전시스템의 지능형 재폐로방식을 제안하였다. 재폐로 시도횟수를 늘릴수록 공급신뢰도는 향상될 수 있지만, 전력설비에는 사고전류에 의한 충격이 누적된다. 제안된 방식은 사고전류의 크기에 따라 재폐로 시도횟수와 무전압시간을 결정하여 배전시스템 공급신뢰도를 유지하면서 전력설비의 피해를 감소시킬 수 있다. 사례연구에서는 현장 운전 데이터를 사용하여 제안된 지능형 재폐로방식에 대한 효율성을 입증하였다.

  • PDF