• Title/Summary/Keyword: Electric power equipments

Search Result 218, Processing Time 0.024 seconds

A plan to harmonize the equipments of power distribution with its environment (배전설비의 환경조화방안)

  • Lee, Jae-Gwan;Kim, Sang-Yul
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1206-1209
    • /
    • 1998
  • For 21th Century, the assignment of power distribution will be the expansion of equipments to supply electric power and harmony with its environment, in process of approving value consciousness of land, space, and the preservation of surroundings. This paper proposes a plan to match with the requirement about equipments, having ability to supply electric power, being harmonized itself with its surroundings by applying a general concept of "Amenity" when we choose an established form of power distribution.

  • PDF

An Investigation Into the Actual Condition of Electrical Equipments Installation and Management for Establishing the Countermeasures Against the Electric Shock in Submerged Underground (지하구내 침수시 감전 방지대책 수립을 위한 전기설비 설치 및 관리실태 조사)

  • Jung, Jin-Soo;Jung, Jong-Wook
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.84-90
    • /
    • 2008
  • This paper describes the investigation into the actual condition of electrical equipments installation and management for establishing the countermeasures against the electric shock in submerged underground. The investigation was carried out for 27 underground premises in conurbation including Seoul, and potential of the exposed electrical equipments negatively affecting on human safety when disaster occurs was measured. The objects to which measurement was carried out were as follows; electrical source; advertising lighting; power equipment. As a result, it was confirmed that potentials more than 230[V] were induced in some equipments. In addition, the electrical equipments installed in most conventional underground premises were left unmanaged.

A Dynamic Characteristics on Non-linear Voltage Electric Equipment under Voltage Sag (순간전압강하에 대한 비선형 저압전기기기의 동적특성)

  • Lee, Hyun-Chul;Jeong, Sung-Won;Gim, Jae-Hyeon;Lee, Geun-Joon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.336-343
    • /
    • 2008
  • In this study, a transition of power quality was characterized by non-linear voltage electric equipments under voltage sag. The test was inputted voltage sag to IPC(Sag Generator) from AVR, and then to equipments by IPC which adjust voltage magnitude and duration. The load test which non-linear voltage electric equipments used PLC, Magnetic Contactor, SMPS, HID Lamp. The test result was different from each other according to a manufacturing companys, models, and equipments. PLC was greatly described to be stabilized voltage sag in case of no load then rated load. Magnetic Contactor was made a difference to phase angles on voltage sag, which was $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$. HPD Lamp was described to be stabilized the sodium lamp, and to be unstabilized the metal hailed lamp. The test result was showed CBEMA curve that stand for evaluated responsiveness of voltage sag. This study was tested description to dynamic characteristics on non-linear voltage electric equipment under voltage sag. There was hoped that power system designed the essential particulars.

The Analysis of Temperature Distribution Electric incoming Apparatus Using a Infrared Thermal Imaging System (적외선 열화상 카메라를 이용한 수전설비 온도분포해석)

  • Jeong, Seung-Cheon;Lim, Yeung-Bae;Kim, Jong-Seo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1113-1116
    • /
    • 2004
  • This paper presents the method for analyzing surface temperature of Electric incoming Apparatus. For the experiment, the surface temperature of electric power apparatus was measured and analyzed by using a infrared thermal imaging system. Surface Discharges(SD) have very complex characteristics of discharge patterns, therefore it requires the development of precise analysis methods. recently, studies on infrared thermal imaging system are carried out to analyze temperature distribution of power equipments through condition diagnosis and to diagnose the degradation of power equipments. The changes in suface temperature was measured by using the infrared thermal imaging system under hot line condition. The system was set up based on the diagnostic method of the electric incoming apparatus.

  • PDF

Nondestructive Testing and Applications for Electric Power Plant Equipments by Acoustic Emissin Technology (음향방출기술에 의한 발전설비 비파괴검사 및 응용)

  • Lee, Sang-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.396-409
    • /
    • 2004
  • Diagnosis f structural integrity is the basis for correct treatment of and countermeasures against progressive structural abnormalities. An exact diagnosis is at present the most reliable means for determining the soundness of structures during power plant operations. Acoustic emission(AE) technology has recently strengthened its application base, and practitioners' understanding of the technique's fundamentals. This paper presents the results of a survey and assessment on AE monitoring applications in nuclear, fossil and hydraulic power plant. The main objective of this paper was to obtain information on various applications of AE technology in electric power plant.

A Study on the Temperature Characteristics of High Voltage Power Cable for Hybrid Electric Vehicle (하이브리드 자동차용 고압 케이블의 온도 특성에 관한 연구)

  • Lee, Ki-Yeon;Kim, Dong-Woo;Kim, Dong-Ook;Gil, Hyoung-Jun;Kim, Hyang-Kon;Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.338-342
    • /
    • 2008
  • Hybrid Electric Vehicle(HEV) is driven by an internal-combustion engine and an electric motor. It is a combination of an internal-combustion engine and several electrical equipments which use a high voltage battery, an electric motors, an inverter and others. But there is not any separate detailed enforcement regulations for high voltage electric appliances in the existing vehicle-related safety standards. So, test standards suggestion as well as test technique development need to be done for ensuring electrical safety, for an electric motor, a high voltage battery, a(n) inverter/converter and an electric power transmission units and other equipments to ensure the safety of high voltage electric appliances which is the HEV key electrical component. In this paper, We are to provide helpful data to support test technique development and test standard establishment for HEV design and electrical safety security by the following methods; by measuring the voltage, the electric current, and the frequency of HEV, by analyzing electrical characteristics of high voltage electric appliances, and by analyzing temperature characteristics of the electrical current among the analyzed electrical characteristics by thermal imagining cameras.

Induced Current Calculation in a Human Body Model due to Magnetic field in High Speed Railway (고속철도내 자기장에 의한 인체 모델에서의 유도 전류 계산)

  • Han, In-Su;Lee, Tae-Hyung;Park, Choon-Soo;Kim, Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.208-213
    • /
    • 2008
  • In recent society, the quality of human life has improved due to the use of electric appliances and the high powered electrical equipments. However, lots of electric appliances and equipments generate the electromagnetic field hazard. Many studies have been made about the wrong behavior of machines due to electromagnetic fields, the interferences in communication equipments, the possibility of the electromagnetic field hazard in human body, etc. There exist international standards about the RF equipments (ex. mobile phone, antenna, etc.). But, many researchers involved in power frequency electric and magnetic field only propose the prudential avoidance. In this paper, induced currents in a human body model due to magnetic fields in high speed railway are calculated by two dimensional impedance method. Power frequency(60Hz) magnetic fields are calculated and induced currents are simulated by Faraday's law. Induced currents are simulated with induced voltage, human body model impedances due to Ohm's law, magnetic fields derived from Biot-Savart's law and Transmission Line Method in high speed railway.

  • PDF

Application of CFD Method to Performance Prediction of Fire-Suppression System for Electric Power Utilities (발전설비용 소화시스템의 성능 예측을 위한 CFD기법 적용 연구)

  • Chung, H.T.;Bae, K.Y.;Kim, C.H.;Jeong, I.S.;Bae, J.S.;Han, Y.S.;Kim, J.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.296-299
    • /
    • 2008
  • In the present research, the exclusive analysis system based on the CFD method were suggested to predict the fire-suppression performance of water mist fire-suppression equipments for design applications. The computing scope is ranged from starting pump to fire-suppression equipments, composed of three parts that calculation of flow rate and pressure distribution at each nozzle, examining of spray performance and predicting of fire-suppression performance in the fire space. Application were done to the fire-suppression system for electric power generation plants. The results were analyzed by comparison between numerical results and initial design conditions in terms of thermal and fluid mechanics.

  • PDF

DIAGNOSIS OF DETERIORATION FOR HIGH VOLTAGE CABLE (전력 케이블의 열화진단)

  • Choi, Chang-Su;Kim, Young;Kim, Jang-Woen;Kim, Young-Nam
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1353-1355
    • /
    • 1995
  • While the modern society has been highly diversified and civilized, the demand for the safty of a power transmission has been greatly increased. For the underground cable, the performance of the electrical equipments is being improved by developing a new technology, and the reliability of the power supply is being up graded by impressing the diagnostic and monitoring technology of the system. In this paper the aging procedure of O.F and XLPE cables are described, including the diagnostic and monitoring equipments and the future subject.

  • PDF

Intelligent Reclosing Scheme to reduce a Damage of Power Equipments (전력설비 피해 감소를 위한 지능형 재폐로방식에 관한 연구)

  • 임성정;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.1
    • /
    • pp.112-117
    • /
    • 2001
  • This paper presents an intelligent reclosing scheme to reduce a damage of power equipments in power distribution systems. As the number of reclosing shot increases, an power supply reliability is improved, but an impact of electric facilities by fault currents is accumulated. The proposed scheme determines the number of reclosing shots and its intervals according to ilie magnitude of fault current. Therefore, this scherre reduces a harm of electric facilities and muntains the power supply reliability. Case studies is performd to verify the effectiveness of the proposed scheme using field operation data.

  • PDF