• 제목/요약/키워드: Electric measurement

검색결과 1,649건 처리시간 0.029초

불화나트륨 이온도포와 Nd:YAG laser 조사가 치근면 내마모성에 미치는 영향 (Effect of NaF iontophoresis and Nd:YAG laser irradiation on the abrasion-resistance of root surface)

  • 김진덕;염창엽;김송욱;김병옥;한경윤
    • Journal of Periodontal and Implant Science
    • /
    • 제27권4호
    • /
    • pp.819-828
    • /
    • 1997
  • The purpose of this study was to evaluate the abrasion-resistance of root surface after NaF iontophoresis, Nd:YAG laser irradiation and combined treatment 50 anterior teeth with flat interproximal root surface that had been extracted due to periodontal destruction were selected. All teeth were treated by the same procedure as conventional periodontal root treatment, such as scaling and root planing, root conditioning with tetracycline HCI(lOOmg/ml, 5min). The pre-treatment weight of each tooth was measured by a dial scale(SHIMADEU Co, LIBROR EB-220HU, capacity 220.000 g, Japan). All teeth were divided into 5 groups as follows: Nd:YAG laser irradiation(group 1, 1 W, 100 mJ, 10Hz, fiberoptic-root surface distance=5mm, $10\;sec.{\times}6times$, EL.EN.EN060, Italy): NaF iontophoresis(group 2, $150{\mu}A$, 4 min}: Nd:YAG laser irradiation following NaF iontophoresis(group 3): NaF iontophoresis following Nd:YAG laser irradiation(group 4): No treatment(control group). Electric toothbrushing (Oral-B, Brown Co, Germany) was conducted during 1 hour($lO\;min.{\times}6\;times$). Subsequently post-treatment weight was remeasured by the same method as pre-treatment weight measurement. The difference of abrasion rate among all groups was statistically analyzed by ANOVA(SAS program). Following results were obtained: 1. The abrasion rate was significantly lower in Nd:YAG laser irradiation group than NaF iontophoresis group(p < 0.001). 2. The abrasion rate was significantly lower in combined groups of Nd:YAG laser irradiation and NaF iontophoresis than either Nd:YAG laser irradiation group or NaF iontophoresis group(p < 0.001). 3. There was no significant difference in abrasion rate according to application order in the combined groups(p > 0.05). 4. The abrasion rate was significantly lower in all experimental groups than control group(p < 0.001). The results suggest that combined treatment of Nd:YAG laser irradiation and NaF iontophoresis on exposed root surface after periodontal therapy can enhance the abrasion-resistance of root surface and may inhibit the root caries development.

  • PDF

고층 건축공사의 시공성 향상을 위한 설계단계의 시공엔지니어링 업무 도출 - 가설공사를 중심으로 - (Identifying Construction Engineering Tasks at the Design Phase for Enhancing Constructability in High-rise Building Construction - Focused on Temporary Work -)

  • 이진웅;조규만;김태훈
    • 한국건축시공학회지
    • /
    • 제17권5호
    • /
    • pp.453-463
    • /
    • 2017
  • 건물의 고층화와 규모의 증가로 인해 프로젝트 설계단계에서의 시공성을 반영한 엔지니어링 기술의 중요성이 점점 커지고 있다. 특히, 설계단계에서의 가설작업을 위한 설비, 장비 및 공법과 관련된 엔지니어링 기술적용의 노력은 시공성 및 프로젝트 성과 향상에 크게 기여할 수 있다. 이에 본 연구에서는 고층 건축공사의 시공성 향상을 위하여 가설공사를 중심으로 설계단계에 요구되는 시공엔지니어링 업무를 도출하고자 하였다. 우선, 문헌고찰과 전문가 집단면접을 통해 27개의 예비 업무를 도출하였으며, 그 후 설문조사를 통하여 각 업무의 필요성 및 중요도를 분석하였다. 분석 결과, 골조공사 및 양중장비 계획과 관련된 대부분의 업무가 상대적으로 중요한 것으로 분석되었다. 마지막으로 요인분석을 통해 21개의 엔지니어링 업무를 선정하였으며, 이들 업무는 크게 1)골조공사 및 측량/동선계획, 2)양중 및 콘크리트 압송계획, 3)공간구획계획, 4)용수계획, 5)가설건물 및 전력/조명계획의 5개 요인으로 분류되었다. 본 연구의 결과는 설계단계에서 시공엔지니어링 업무를 효과적으로 반영할 수 있는 프로세스 수립을 위한 기초 자료로 활용될 수 있을 것이다.

위성 및 지상자력계에서의 PI 2 파동 동시 관측 (SIMULTANEOUS OBSERVATIONS OF PI 2 PULSATIONS ON THE SATELLITE AND GROUND-BASED MEASUREMENTS)

  • 이성환;이동훈;김관혁
    • Journal of Astronomy and Space Sciences
    • /
    • 제14권2호
    • /
    • pp.275-285
    • /
    • 1997
  • 1989년 2월에 일본의 우주과학연구소(ISAS: Institute of Space and Astronautical Science)에서 발사한 과학위성 EXOS-D의 전기장 측정기와 지자기 자오선 동경 190/210 선상에 위치하고 있는 17개의 지상자력계들로부터 1994년 11월 09일 18시 50분부터 약 20분에 걸쳐 Pi 2 파동이 검출되었다. 우리가 이용한 지상자력계는 지자기 경도는 동경 185.02에서 동경 269.36사이, 지자기 위도는 -37.09에서 65.67사이에, L값은 1.00에서 5.89사이에 위치하고 있다. 또한 같은 시각에 또 다른 위성 ETS-VI의 자기장 측정기의 자료와 지상의 Kakioka(지자기 동경 208.00, 지자기 위도 26.70), Hermanus(지자기 동경 82.97, 지자기 위도 -33.78) 지상자력계의 자료도 함께 사용하여 비교하여 보았다. Pi 2 파동의 주파수를 알아내기 위하여 FFT를 이용하였으며, L값이 2.35인 EXOS-D 위성과 지상자력계들에서는 주파수가 약 25mHz에서 최대 값을 보였으나, L값이 6.60인 ETS-VI위성에서는 같은 주파수가 검출되지 않았다. 또한 지상자력계 중에서 MUT 지상자력계의 자료를 기준으로 하여 위성들과 나머지 지상자력계들간의 상관관계, 위상 차를 조사하여, 발견된 Pi 2 파 동 현상이 플라즈마구 내에서 형성된 공동(cavity) mode에 의한 현상임을 알 수 있었다.

  • PDF

평판형 디지털 엑스레이 가스 검출기의 엑스선 특성 측정기술에 관한 연구 (X-ray properties measurement of Flat panel Digital X-ray gas detector)

  • 윤민석;조성호;오경민;정숙희;남상희;박지군
    • 한국방사선학회논문지
    • /
    • 제3권1호
    • /
    • pp.17-21
    • /
    • 2009
  • 최근 의료진단 분야와 다른 적용분야를 위해 대면적 매트릭스 구조의 엑스선 영상이 활발하게 연구되어 오고 있다. 본 연구에서는, 의료진단을 위한 새로운 평판형 디지털 엑스선 가스 검출기를 제안하고 그에 따른 특성을 검증하고자 한다. 대기압에 반해 가스를 주입하는 어려움 때문에 챔버 형태의 구조로 만들어 질 뿐, 평판형 디지털 엑스선 가스 검출기는 아직 어디에서도 연구된 바 없다. 이에 본 연구에서는 디스플레이 패널 제작 기술을 이용하여 샘플제작을 성공하였다. 실험적인 측정을 위해 만들어진 샘플은 상판에는 유리기판위에 전극, 절연층, 산화마그네슘 보호막을 형성하였으며, 하판에는 엑스선 형광층과 전극을 형성하였다. 누설전류와 엑스선 민감도를 측정하였으며, 전기장에 대한 민감도의 선형성 측정 등의 전기적 특성평가를 실시하였다. 이에 대한 결과로 안정된 누설전류와 엑스선 민감도를 얻었다. 그리고 조사 선량에 따라 좋은 선형성을 보이는 등 넓은 진단 동적영역을 확인할 수 있었다. 이러한 결과로 평판형 엑스선 가스 검출기의 디지털 엑스선 영상 검출기로의 적용 가능성을 확인 할 수 있었다.

  • PDF

저주파음에 의한 자리돔의 청각 능력 2. 청각 임계비 및 청각능력지수 (The Hearing Ability of Coralfish Chromis notatus to Low Frequency Sound 2. The Auditory Critical Ratio and Hearing Index)

  • 이창헌;서두옥
    • 수산해양기술연구
    • /
    • 제36권4호
    • /
    • pp.314-321
    • /
    • 2000
  • 제주 연안역에 있어서 수중 가청 저주파수음을 이용한 자원관리형 어업, 또한 어장에서 음향을 이용해서 어류를 유집할 수 있는 음향 어법 개발의 기초 자료를 얻기 위해 자리돔을 대상으로 측정 주파수 80∼800Hz의 수중음과 7V의 직류 전원의 전기 자극을 이용하여 육상 수조에서 조건 학습을 시킨 후 측정 주파수와 음압을 임의로 변화시켜 가면서 실험어 심전도를 도출하여 심박 간격의 변화로부터 청각 문턱치 곡선과 함께 백색 잡음에 의한 청각 임계비 및 청각 능력 지수를 조사한 결과는 다음과 같다. 자리돔의 청각 임계비는 측정 주파수 80Hz, 100Hz, 200Hz, 300Hz, 500Hz, 800Hz에서 음압이 각각 31dB, 35dB, 33dB, 23dB, 34dB, 41dB이고, 음압 73dB, 78dB, 83dB의 3단계 백색 잡음을 방성하였을 때 청각 문턱치는 백색 잡음이 없을 때보다 높게 나타나며 마스킹 효과가 측정 주파수 100Hz, 200Hz, 300Hz에서 보다 뚜렷하게 나타났다. 마스킹 현상은 약 음압 60∼65dB의 백색 잡음 레벨에서 나타나기 시작하였으나, 측정주파수 200Hz에서는 음압 57dB 이상에서, 측정주파수 800Hz에서는 73dB 이상의 백색 잡음 레벨에서 나타났으며 주파수 측정 주파수 300Hz에서 신호음을 인식하기 위해서는 대략 음압 88dB 이상과 함께 백색 잡음 레벨보다 음압 23dB 이상 높은 신호음이 요구되었으며 배경 잡음시 자리돔의 청각능력지수는 81로 나타났다.

  • PDF

안면부에 잔류된 다양한 이물질을 측정한 CT 계수 (CT Number Measurement of Residual Foreign Bodies in Face)

  • 위서영;최환준;김미선;최창용
    • Archives of Plastic Surgery
    • /
    • 제35권4호
    • /
    • pp.423-430
    • /
    • 2008
  • Purpose: Computed tomography theoretically should improve detection of foreign bodies and provide more information of adjacent soft tissues. And the CT scanner and PACS program proved to be an excellent instrument for detection and localization of most facial foreign bodies above certain minimum levels of detectability. The severity of injury in penetrating trauma to the face, it is often underestimated by physical examination. Diagnosis of a retained foreign object is always critical. Methods: From March, 2005 to February 2008 a study was done with 200 patients who had facial trauma. Axial and coronal CT images were obtained with a General Electric(Milwaukee, Wis) 9800 CT scanner at 130 kV, 90 mA, with a 2-mm section thickness and a $512{\times}512$ matrix. Results: Axial and coronal CT images at various window widths should be used as the first imaging modality to detect facial foreign bodies. The attenuation coefficients for the metallic and nonmetallic foreign bodies ranged from -437 to +3071 HU. As a general rule, metallic foreign bodies produced more Hounsfield artifacts than nonmetallic foreign bodies, thus providing a clue to their composition. All of the metallic foreign bodies were represented by a single peak and had a maximum attenuation coefficient of +3071 HU. Of the nonmetallic foreign bodies, glass had an attenuation coefficient that ranged from +105 to +2039, while plastic had a much lower coefficient that ranged from -62 to -35. wood had the lowest range of attenuation coefficients: -491 to -437. Conclusion: The PACS program allows one to distinguish metallic from nonmetallic foreign bodies and to individually identify the specific composition of many nonmetallic foreign bodies. This program does not, however, allow identification of the specific composition of a metallic foreign body. We recommend this type of software program for CT scanning of any patient with an injury to the face in which a foreign body is suspected.

미세금형 가공을 위한 전기화학식각공정의 유한요소 해석 및 실험 결과 비교

  • 류헌열;임현승;조시형;황병준;이성호;박진구
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2012년도 춘계학술발표대회
    • /
    • pp.81.2-81.2
    • /
    • 2012
  • To fabricate a metal mold for injection molding, hot-embossing and imprinting process, mechanical machining, electro discharge machining (EDM), electrochemical machining (ECM), laser process and wet etching ($FeCl_3$ process) have been widely used. However it is hard to get precise structure with these processes. Electrochemical etching has been also employed to fabricate a micro structure in metal mold. A through mask electrochemical micro machining (TMEMM) is one of the electrochemical etching processes which can obtain finely precise structure. In this process, many parameters such as current density, process time, temperature of electrolyte and distance between electrodes should be controlled. Therefore, it is difficult to predict the result because it has low reliability and reproducibility. To improve it, we investigated this process numerically and experimentally. To search the relation between processing parameters and the results, we used finite element simulation and the commercial finite element method (FEM) software ANSYS was used to analyze the electric field. In this study, it was supposed that the anodic dissolution process is predicted depending on the current density which is one of major parameters with finite element method. In experiment, we used stainless steel (SS304) substrate with various sized square and circular array patterns as an anode and copper (Cu) plate as a cathode. A mixture of $H_2SO_4$, $H_3PO_4$ and DIW was used as an electrolyte. After electrochemical etching process, we compared the results of experiment and simulation. As a result, we got the current distribution in the electrolyte and line profile of current density of the patterns from simulation. And etching profile and surface morphologies were characterized by 3D-profiler(${\mu}$-surf, Nanofocus, Germany) and FE-SEM(S-4800, Hitachi, Japan) measurement. From comparison of these data, it was confirmed that current distribution and line profile of the patterns from simulation are similar to surface morphology and etching profile of the sample from the process, respectively. Then we concluded that current density is more concentrated at the edge of pattern and the depth of etched area is proportional to current density.

  • PDF

LiFe0.9Mn0.1PO4 물질의 결정구조 및 뫼스바우어 분광 연구 (Studies on Crystallographic and Mossbauer Spectra of the LiFe0.9Mn0.1PO4)

  • 권우준;이인규;이찬혁;김삼진;김철성
    • 한국자기학회지
    • /
    • 제22권1호
    • /
    • pp.15-18
    • /
    • 2012
  • Olivine 구조인 $LiFe_{0.9}Mn_{0.1}PO_4$ 분말 시료를 직접합성법(solid state method) 으로 제조하였으며, 결정학적 및 자기적 특성을 x-선 회절(x-ray diffractometer), 초전도 양자 간섭계(superconducting quantum interference devices) 및 뫼스바우어 분광(M$\ddot{o}$ssbauer spectroscopy) 실험을 이용하여 연구하였다. $LiFe_{0.9}Mn_{0.1}PO_4$ 시료의 결정구조는 공간그룹이 Pnma인 orthorhombic 구조임을 Rietveld 정련법으로 분석하였다. $LiFe_{0.9}Mn_{0.1}PO_4$ 시료의 닐온도 (N$\acute{e}$el temperature; $T_N$)는 50 K으로 나타내었고 닐온도에서 자기 상전이가 일어나는 것을 초전도 양자 간섭계 실험을 통하여 확인하였다. Fe(Mn)-O 이온간 거리를 분석하여 $FeO_6(MnO_6)$ 팔면체 구조가 비대칭임을 확인하였고 그 구조로 인하여 강한 결정장에 영향을 받으며, 닐온도 이상에서 자기 2중극자 상호작용은 사라지고, 강한 결정장에 의한 전기 4중극자 작용만이 존재하여 두 개의 흡수선이 나타나는 것을 뫼스바우어 분광 실험을 통하여 분석하였다.

사분파장 위상 간섭계 폴리머 광집적회로 기반 광전류센서의 온도 안정성 향상 연구 (Improvement of Thermal Stability of Optical Current Sensors Based on Polymeric Optical Integrated Circuits for Quadrature Phase Interferometry)

  • 천권욱;김성문;박태현;이은수;오민철
    • 한국광학회지
    • /
    • 제30권6호
    • /
    • pp.249-254
    • /
    • 2019
  • 광섬유가 지니는 패러데이 효과를 이용하여 전류의 세기를 측정하는 광전류 센서 소자를 설계 및 제작하였다. 센서 소자의 동작 안정성을 향상시키기 위하여 편광회전 반사 간섭계와 사분 파장 위상 간섭계 구조를 도입하였다. 이 복잡한 구조를 구성하는 다양한 광소자들은 하나의 폴리머 광집적회로로 구성하여 작은 크기로 제작되었다. 본 구조를 이용하면 외부에서 별도의 바이어스 피드백 제어가 필요 없는 상태에서 전류를 측정하는 센싱 동작을 수행할 수 있다. 또한 온도변화나 외부진동으로 인한 광센서 특성 변화를 제거하여 안정적인 특성을 유지하는 광전류센서를 구현할 수 있다. 그러나 패러데이 효과를 결정짓는 베르데상수는 온도에 따라 미소한 값의 변화를 가지고 있다. 본 연구에서는 이 변화로 인한 광전류센서의 온도의존성을 극복하기 위한 연구를 수행하였다. 편광회전 반사 간섭계의 부품인 광섬유 사분 파장판의 길이를 최적값으로부터 벗어나는 상태로 맞추어 줌으로써 베르데 상수의 온도의존성에 의해 나타나는 광전류센서의 스케일 팩터 변화를 보상해줄 수 있었다. 온도변화를 보상한 광전류센서는 주변 온도를 상온에서 85℃로 올리는 동안, 센서 측정 신호의 온도 의존성이 0.2% 이내로 유지되는 것을 확인했다.

음향광학 파장선택 필터 기반 파장훑음 레이저를 이용한 시간-인코딩 된 근적외선 흡광도 측정 비교 연구 (Time-encoded Near-infrared (NIR) Spectroscopic Comparison of Absorbance Measurement Using an Acousto-optic NIR Swept Laser Source)

  • 장한솔;김경훈;한가희;조재두;김창석
    • 한국광학회지
    • /
    • 제28권1호
    • /
    • pp.22-27
    • /
    • 2017
  • 본 논문에서는 음향광학 파장선택 필터(acousto-optic tunable filter) 기반의 파장훑음 레이저(wavelength swept laser)를 이용한 시간-인코딩 근적외선 분광 기술(time-encoded near-infrared spectroscopy)을 제안하였다. 파장훑음 레이저는 800 nm 근처 영역에서 이득 스펙트럼을 가지는 반도체 광 증폭기(semiconductor optical amplifier)를 기반으로 제작되었으며, 음향광학 파장선택 필터를 공진기 내부에 삽입함으로써 음향광학 파장선택 필터에 인가되는 전기적 라디오주파수에 따라 출력 파장을 선택할 수 있도록 하였다. 본 연구에서는 종래의 기술인 백색광 분광기 기반의 검출부 분광 근적외선 분광 기술과 제안된 파장훑음 레이저 기반의 광원부 분광 근적외선 분광 기술을 각각 이용하여 근적외선 흡수 염료 샘플의 흡광도를 각기 측정하여 실험적으로 비교함으로써 본 연구에서 제안하는 음향광학 파장선택 필터 기반 파장훑음 레이저를 이용한 근적외선 분광 기술의 특성을 증명하였다.