• 제목/요약/키워드: Electric field measuring device

검색결과 29건 처리시간 0.022초

뇌방전에 의하여 발생하는 전계파형의 측정과 분석 (The measurement and analysis of the electric field waveforms produced by lightning discharges)

  • 이복희;주문노;길경석;안창환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.444-446
    • /
    • 1995
  • This paper deals with semisphere-type sensor fo measuring the electric field waveforms by lightning discharges. The theoretical principle and design rule of the device are introduced, and also the calibration and application investigations are carried out. From the calibration experiments, the frequency bandwidth of the semisphere-type electric field measuring device ranges from 200 [Hz] to 1.56 [MHz], and the sensitivity of sensor is 0.96 [mV/V/m]. The electric field waveforms produced by lightning discharges were observed for June and August 1995. It is shown that the electric field waveforms produced at the distance of more than 50 [km] include only radiation component.

  • PDF

다중 낙뢰에 의해서 발생한 전장 파형의 특성 (Characteristics of the Electric Fields Produced by Multiple Lightning Return Strokes)

  • 이복희;정동철;이동문
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권6호
    • /
    • pp.330-336
    • /
    • 2004
  • In this work, in order to obtain the detailed information about lightning electromagnetic pulses, the electric fields radiated from multiple lightning return strokes were measured and analyzed statistically. The electric field measuring system consists of a hemisphere antenna of 30cm in diameter, integrator and data acquisition device, and its frequency bandwidth ranges from 200Hz to 1.56MHz, and the sensitivity is 0.96㎷/V/m. The electric field signals are digitized every 200ns with the transient signal analyzer having the resolution of 12-bit and the recording length of 5 kilowords and are registered at personal computer. As a result, the electric fields produced by the first return stroke begin with a slow initial part or front, which starts just after or during the last stepped leader. On the average the rise times of the electric fields for the positive first, second and third strokes are 4.21${\mu}\textrm{s}$, 3.94${\mu}\textrm{s}$ and 2.75${\mu}\textrm{s}$, respectively, and those for the negative first, second and third strokes are 3.46${\mu}\textrm{s}$, 3.15${\mu}\textrm{s}$ and 2.79${\mu}\textrm{s}$, respectively. The zero-crossing times of the electric fields for first return strokes range from about 10 to 80${\mu}\textrm{s}$. The mean zero-crossing times for subsequent return strokes are shorter than those for first lightning return strokes.

시변전장 측정용 평판형 센서 (Planar-type Sensor for Measuring the Time-varying Electric Fields)

  • 이복희;길경석
    • 센서학회지
    • /
    • 제4권1호
    • /
    • pp.15-20
    • /
    • 1995
  • 본 논문은 시변전장을 측정할 수 있는 평판형 센서에 대하여 기술하였다. 광대역의 전장측정계를 구현하기 한 평판형 센서가 제안되었다. 측정계의 이론적인 원리와 설계방법에 대하여 제시하였으며, 교정실험 및 적용실험을 수행하였다. 교정실험을 통하여 전장측정계의 주파수대역과 감도는 $160\;[Hz]\;{\sim}\;25\;[MHz]$, 1.2 [mV/V/m] 이었다. 적용실험으로 고전압 실험실에서 임펄스전압과 진동성 과도전압에 의해 발생되는 전장을 제안된 측정장치로 측정하였으며, 측정결과는 우수하였다.

  • PDF

필드 밀을 이용한 대지전장 측정장치 개발 (Development of Measuring Device for Electric Field on the Ground Level Using a Field Mill)

  • 송재용;김명진;길경석;천상규
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.469-473
    • /
    • 2001
  • This paper describes a rotation-type field mill to measure the electric field intensity caused by thunderclouds on the ground level. The field mill developed is consisted of two isolated electrode vanes, a grounded stator and a rotor. To develop a high sensitive field mill, the principles and design rules of a rotation-type field mill are studied. Also, two types of calibration system, such as a cylindrical guard electrodes and a parallel-plate electrodes, are proposed to determine the sensitivity and frequency bandwidth of the field mill. From the calibration experiment, the frequency bandwidth and the sensitivity of the field mill arc DC ∼ 200 [MHz] and 0.267 [mV/Vm], respectively. Therefore, it can measure the electric field intensity from 73[V/m] to 18.7[kV/m].

  • PDF

뇌방전에 의해서 발생하는 전계파형의 특성 (Characteristics of the Electric Field Waveforms Associated with Lightning Discharges)

  • 박성열;이복희;안창환;전덕규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1879-1881
    • /
    • 1996
  • This paper describes the fine structure of electric field waveforms produced by lightning return strokes. The electric field measuring system consists of hemisphere antenna 30 cm in diameter, integrator and data acquisition device. Its frequency bandwidth is from 200 Hz to 1.56 MHz, and the sensitivity is 0.96 mV/V/m. Electric field signals are digitized every 200 ns with the resolution of 12-bit and the length of 5 kilowords, and those are registered by a personal computer. Also data are analyzed by means of the fast Fourier transform (FFT) method.

  • PDF

심질환 진단을 위한 심자도 파라메터의 추출 (Estimation of MCG parameters for the diagnosis of heart diseases)

  • 전창익;허영;김기욱;한병희;진승오;장원석;이현호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 신호처리소사이어티 추계학술대회 논문집
    • /
    • pp.549-552
    • /
    • 2003
  • The electrical current generated by heart creates not only electric potential but also a magnetic field. We have observed electrophysiological phenomena of the heart by measuring tangential components of magnetocardiogram(MCG) using 61 channel superconducting quantum interference device(SQUD) system. In this paper, we developed a new analysis method, which is based on the theory of electromagnetic field. We show some differences of the current direction between the normal MCG and the abnormal(ischemic heart disease) MCG.

  • PDF

Simulation Study on Measuring Pulverized Coal Concentration in Power Plant Boiler

  • Chen, Lijun;Wang, Yang;Su, Cheng
    • Journal of Information Processing Systems
    • /
    • 제15권1호
    • /
    • pp.189-202
    • /
    • 2019
  • During thermal power coal-fired boiler operation, it is very important to detect the pulverized coal concentration in the air pipeline for the boiler combustion stability and economic security. Because the current measurement methods used by power plants are often involved with large measurement errors and unable to monitor the pulverized coal concentration in real-time, a new method is needed. In this paper, a new method based on microwave circular waveguide is presented. High Frequency Electromagnetic Simulation (HFSS) software was used to construct a simulation model for measuring pulverized coal concentration in power plant pipeline. Theoretical analysis and simulation experiments were done to find the effective microwave emission frequency, installation angle, the type of antenna probe, antenna installation distance and other important parameters. Finally, field experiment in Jilin Thermal Power Plant proved that with selected parameters, the measuring device accurately reflected the changes in the concentration of pulverized coal.

Effect of electric field on primary dark pulses in SPADs for advanced radiation detection applications

  • Lim, Kyung Taek;Kim, Hyoungtaek;Kim, Jinhwan;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • 제53권2호
    • /
    • pp.618-625
    • /
    • 2021
  • In this paper, the single-photon avalanche diodes (SPADs) featuring three different p-well implantation doses (∅p-well) of 5.0 × 1012, 4.0 × 1012, and 3.0 × 1012 atoms/cm2 under the identical device layouts were fabricated and characterized to evaluate the effects of field enhanced mechanisms on primary dark pulses due to the maximum electric field. From the I-V curves, the breakdown voltages were found as 23.2 V, 40.5 V, and 63.1 V with decreasing ∅p-well, respectively. By measuring DCRs as a function of temperature, we found a reduction of approximately 8% in the maximum electric field lead to a nearly 72% decrease in the DCR at Vex = 5 V and T = 25 ℃. Also, the activation energy increased from 0.43 eV to 0.50 eV, as decreasing the maximum electric field. Finally, we discuss the importance of electric field engineering in reducing the field-enhanced mechanisms contributing to the DCR in SPADs and the benefits on the SPADs related to different types of radiation detection applications.

22.9[kV] 배전선로 주변의 전장과 자장의 분포 (Profiles of electric and magnetic fields in the vicinity of 22.9[kV] Distribution Line)

  • 이복희;길형준;안창환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1653-1655
    • /
    • 1998
  • In this paper, measurement and analysis of ELF electric and magnetic fields in the vicinity of 22.9[kV] distribution line have been performed. The height of measuring point from the earth's surface was 1[m], and the distance between the device and the operator was more than 3[m]. The experiments have been carried out by lateral profile, and we have made use of FIELDS program for the sake of comparision the experimental data with the theoretical value. Electric and magnetic fields intensity were strong under a distribution line, and were inversely proportional to lateral distance. The profiles of electric field were M shape and those of magnetic field were $\cap$ shape. Electric and magnetic fields intensity were increased with increasing the measurement height.

  • PDF

전기철도차량 운행에너지 실시간 계측을 위한 에너지 미터링 장치 개발에 관한 연구 (A Study on the Development of a Real-time Energy Metering Device for Electric Railway Vehicles)

  • 김용기;한문섭;천윤영;배창한;윤병주
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.689-694
    • /
    • 2016
  • The objective of this study is to identify the requirements for a energy metering device and develop a real-time energy metering device for measuring energy (electricity) consumption of the electric railway vehicle during its operation. The study also evaluated the performance of the AC voltage sensor, current sensor, and data meter for the device and performed EMC tests such as surge and EFT (Burst). The performance tests showed that the percent errors of the AC voltage sensor and current sensor were ${\leq}0.1%$, and ${\leq}0.5%$ under 10~127V, and 10~250A, respectively. The result of surge and EFT (Burst) tests also indicated that the device had no malfunction in any wave (combination and ring waves) under the treat level with 2kV. The result of the field test also confirmed that the device had no malfunction in data metering.