• Title/Summary/Keyword: Electric field interference

Search Result 102, Processing Time 0.026 seconds

Compensation of Electric Field Interference for Fiber-optic Voltage Measurement System

  • Cho, Jae-Kyong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.2
    • /
    • pp.84-88
    • /
    • 2008
  • In this paper, we analyze the errors associated with electric field interference for fiber-optic voltage sensors working in a three-phase electric system. For many practical conductor arrangements, the electric filed interference may cause errors unacceptable for the accuracy requirements of the sensors. We devised a real time compensation method for the interference by introducing geometric and weight factors. We realized the method using simple electronic circuits and obtained the real time compensated outputs with errors of 1 %.

Optical Current Measuring System for Compensating Interference by Adjacent Electric Wires

  • Cho, Jae-Kyong
    • Journal of Magnetics
    • /
    • v.12 no.4
    • /
    • pp.156-160
    • /
    • 2007
  • In this paper, we analyze the errors associated with magnetic field interference for fiber-optic current sensors working in a three-phase electric system and provide a solution to compensate the interference. For many practical conductor arrangements, the magnetic filed interference may cause errors unacceptable for the accuracy requirements of the sensors. We devised a real time compensation method for the interference by introducing geometric and weight factors. We realized the method using simple electronic circuits and obtained the real time compensated outputs with errors of ${\pm}1%$.

Development of an Electric Field Sensor using Reflective Interference Type Optical Modulator (반사간섭형 광변조기를 이용한 전계 계측센서의 개발)

  • Choi, Young-Kyu
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.333-340
    • /
    • 1999
  • A reflective interference type optical modulator to compose the electric field sensor is proposed, and the performance and characteristics are theoretically analyzed. For the high sensitivity of the sensor, a method to improve the modulation index of the modulator is presented. The electric field sensor using $Ti:LiNbO_3$ waveguide was fabricated and qualitatively investigated the characteristics by measuring the low frequency electric field. Even though the sensor showed very low modulation index of 5%, the electric filed strength of 5 V/cm was measured. The experimental results revealed the utilities of this type electric field sensor.

  • PDF

Low Frequency Electric Field Sensor using a Reflective Interference Type of Optical Modulator (반사간섭형광변조기를 이용한 저주파 전자계 계측센서)

  • Choi, Young-Kyu;Kim, Girae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.10
    • /
    • pp.471-476
    • /
    • 2005
  • We proposed an optical modulator of reflective type to compose the electric field sensor, and theoretically analyzed the performance and characteristics. For the high sensitivity of the sensor, a method to improve the modulation index of the modulator was presented. The electric field sensor using Ti:LiNbO$_{3}$ waveguide was fabricated and qualitatively investigated the characteristics by measuring the low frequency electric field. Even though the sensor showed relatively low modulation index, the electric filed strength of 10$^{-2}$V/m was measured. The experimental results revealed the utilities of this type electric field sensor.

Characteristics of TV Ghost Interference from Extra High Voltage Transmission Line (초고압 송전선로에 의한 TV Ghost 장해 발생 특성)

  • Ju, Mun-No;Yang, Gwang-Ho;Lee, Dong-Il;Sin, Gu-Yong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.8
    • /
    • pp.412-417
    • /
    • 2000
  • TV ghost interference can be described as passive interference by the conducting part of transmission lines. In order to survey this interference from large-sized overhead EHV (extra high voltage) transmission line, TV reception quality was measured in the vicinity of that before and after construction. Instrumentation system was composed of ghost analyzer, TV received field intensity meter, VHF/UHF antennas, TV monitor and so on. The system is installed inside the vehicle. TV field intensity and PDUR (Perceived Desired wave to Undersired wave Ratio) are measured to evaluate TV ghost by using the system and vehicle. As the results, the useful data, which can be used to evaluate the effect of TV ghost interference from transmission lines could be obtained. In this paper, it is shown that the range of TV ghost interference from transmission lines can vary according to the frequency of TV electromagnetic wave, an incidence angle to the line and the other conditiions. At present, we are making efforts to establish a PDUR guideline for transmission lines.

  • PDF

Robust Electric Compass to Dynamic Magnetic Field Interference

  • Ko, Jae-Pyung;Kim, Yang-Hwan;Kang, Woong-Ki;Lee, Jang-Myung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1814-1819
    • /
    • 2004
  • The purpose of this research is to improve the reliability of automobile navigation system that utilizes the magnetic compass for localization. On account of its sensitiveness against the dynamic external interference of the magnetic field, the electronic compass itself is not accurate enough to be used for the localization compared to the gyro-compass. To overcome this shortcoming, in this research, a robust electronic compass is designed by using two magnetic compasses to cancel out the dynamic interferences efficiently. That is, a dual compass predictive calibration algorithm against irregular external interference of magnetic field is newly proposed and implemented in this paper. When the dynamic interference can be eliminated from the electronic compass, it becomes much accurate than the gyro-based system that suffers from the accumulative drift error. The reliability and performance of the designed system have been verified through the real driving experiments.

  • PDF

Robust Electric Compass to Dynamic Magnetic Field Interference (동적간섭자기장에 강인한 전자컴파스)

  • Ko Jae-Pyung;Kang Woong-Ki;Kim Yang-Hwan;Lee Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.1
    • /
    • pp.27-33
    • /
    • 2005
  • The purpose of this research is to improve the reliability of automobile navigation system that utilizes the magnetic compass for localization. On account of its sensitiveness against the dynamic external interference of the magnetic field, the electronic compass itself is not accurate enough to be used for the localization compared to the gyro-compass. To overcome this shortcoming, in this research, a robust electronic compass is designed by using two magnetic compasses to cancel out the dynamic interences efficiently. That is, a dual compass predictive calibration algorithm against irregular external interference of magnetic field is newly proposed and implemented in this paper. When the dynamic interference can be eliminated from the electronic compass, it becomes much accurate than the gyro-based system that suffers from the accumulative drift error. The reliability and performance of the designed system have been verified through the real driving experiments.

Environmental Impact on the KEPCO 765-kV Double Circuit Transmission Line (한전 765 kV 2회선 송전선로의 전기환경장애 특성)

  • Lee, D.I;Sin, K.Y;Kim, J.B
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.2
    • /
    • pp.117-126
    • /
    • 1999
  • The environmental impact of the KEPCO 765-kV transmission line was studied using a full scale test line in order to develop the design technology. Therefore this paper describes an environmental design summary of the audible noise, hum noise, wind noise, radio interference, TV interference and electric field measurement from the KEPRI 765-kV double circuit transmission test line with a bundle of $6-480mm^2$ conductors per phase. The analysis of the test results shows that 6-Rail and 6-Cardinal conductors bundle satisfy the audible noise criterion & TV interference under the stable rainy weather condition and the radio interference level under the fair weather. And the other items are also agreed with the design level criterion for KEPCO 765-kV transmission line.

  • PDF

Prediction and Analysis of Electrical Environmental Characteristics under ±500kV HVDC Double Bipole Transmission Line (±500kV HVDC 2회선 송전선로의 전기환경특성 예측 및 평가)

  • Woo, Jeong Min;Ju, Mun-No;Shin, Koo Yong;Kwon, Gu Min;Choi, Woo Jung;Lee, Jae Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.4
    • /
    • pp.554-560
    • /
    • 2018
  • Since Korea has a small land area, it is expected to construct the conductor return type with neutral wire in the case of ${\pm}500kV$ HVDC double bipole transmission line. Therefore, in order to apply ${\pm}500kV$ HVDC double bipole transmission line with neutral wire in Korea, it is necessary to develop technology for insulation and environmental designs. In this study, radio interference, audible noise, electric field and ion current density according to the polarity arrangement were compared and assessed in the ${\pm}500kV$ HVDC double bipole transmission line with the conductor return method. And the optimum configuration of HVDC double bipole transmission line was determined from the viewpoint of electrical environment.

Cathodic Protection of Buried Gas Pipelines Using Common Anode Beds (공용양극을 이용한 가스배관의 전기방식)

  • Ha, Y.C.;Kim, D.K.;Bae, J.H.;Ha, T.H.;Lee, H.G.
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.1
    • /
    • pp.19-24
    • /
    • 2008
  • Due to industrialization and urbanization, underground metallic utilities with different owners have been rapidly increased and cathodic protection (CP) methods, especially impressed current CP systems, have been widely adopted to protect their utilities from corrosion with expanded recognition of this method. The stray current interference problem as well as the difficulty in spatial security for system installation, however, came to a ramification of which each owner couldn't resolve for himself. In this respect, this paper illustrates a field-diagnosed example for mutual interference due to separately operated CP systems and suggests an alternative method to overcome the interference situation by design and field-assessment of a common anode bed cathodic protection system.

  • PDF