• Title/Summary/Keyword: Electric dust collector

Search Result 13, Processing Time 0.027 seconds

A Study on the Mass Collection Efficiency in Collector Step of Electrostatic Precipitator by Physical Gas Characterization (전기집진장치에서 가스의 물리적인 특성에 따른 포집구역내의 입자포집율 연구)

  • Ha, Sang-An;Im, Gyeong-Taek;Sin, Nam-Cheol
    • Journal of Environmental Science International
    • /
    • v.7 no.1
    • /
    • pp.36-40
    • /
    • 1998
  • This study was carried out to investigate the collection Efficiency of mass in collector step at the different of physical gas characterization. This work has focused on the dependence of the collection efficiency of mass in the collector zone of a two-stage set up field with gas temperature T and the dew point tmeperature. To identify the dependence of the mass collection efficiency on the Bounded plate of the collector zone MP.k by the spectre electric resistance of dust $p_e$. and the relative humidify ${\varphi}$, 20 at- tempts have been made with three different gas temperature ($50{\circ}C, 80{\circ}C, 110{\circ}C$) at different dew point. At the specific electric resistance of dust $p_e$=$10^6{\Omega}m$ which relative humidity corresponds to $\phi$ > 15%, a easy rise of the sounded plate secluded dust mass share was measured atwain. As the result of the higher cohesion imprisonment power due to the adsorbtion of particle, the rinse of the relative humidity developed on the particle surface. Therefore, the collection efficiency of mass was not predominant the high temperature T in the collector zone, neither was the pecific ellectric resistance of dust dependent.

  • PDF

A study on power source characteristic of a dust collector for power factor compensating (역률보상형 전기집진기 전원장치 특성연구)

  • Lee, Dong-Gil;Hong, Ji-Tae;Kim, Ho-Sung;Son, Min-Kyu;Lee, Kyoung-Jun;Kim, Jong-Rak;Kim, Hee-Jea
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1326-1327
    • /
    • 2008
  • Recently, the air pollution is supposed is to be the most serious environmental problem. Therefore, a small air cleaner is asked to make comfortable indoor environment for the moderns who have frequent indoor activity. In this study, without generating of the second pollution source, dust in the air and harmful microorganisms can be removed by the electric dust collecting technology which has high reliability and efficiency to be able to remove the impurities even though it is just 0.01${\mu}m$. Accordingly, power sources of the dust collector use, it is not inefficiency and offering to dust collector unstable. In order to overcome the point at issue, a this study, for power factor compensating use the PFC circuit, for removing the noise use EMI filter and for generating the hight voltage use the Cockcroft Walton Circuit. And we study power source on characteristic and improvement.

  • PDF

A Study on the Electrostatic Precipitation of Auto-Bias Type by Corona Discharge (코로나방전에 의한 AUTO-BIAS형태의 전기집진에 관한 연구)

  • 이주상;김신도;김광영
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.2
    • /
    • pp.79-88
    • /
    • 1995
  • The electrostatic precipitation of Auto- Bias has the advantages of a little of power consumption by the voltage to apply only at ionizer and the prevention of fire danger by current flow over. As this ionizer wire was used WXN- Pt material of diameter 90$\mu $m, that improved ion efficiency and safety, simplified a existing source of electric power by induced Auto- Bias voltage. Also, the new type collector used electric conductivity- film wag superior a electric safety and dust collection efficiency and was possible to wash it by water. As a experiment result of this Auto- Bias electrostatic collector, the induced Auto- Bias voltage by appling D.C 4.0∼6.0kV at ionizer was 1.3∼2.3kV and then the power consumption by applied voltage was 8- l8W. The pressure loss of collector by the amount of flowing was 6.1 OmmH$_{2}$O in 300m$^{3}$/hr and showed a safe state of the dust collection. The collection efficiency by particle size was 65.1-95.8% in 0.5∼5.0$\mu $m. After corona discharge of ionizer, the remains ozone concentration was found much lower than that of ACGIH or air pollution criteria in Korea.

  • PDF

An Operation Methed for Longitudinal Flow Ventilation System in a Road Tunnel (도로터널에서 종류식 환기 시설의 운전 방안)

  • Kim, T.H.;Hwang, I.J.;Hong, D.H.;Chung, J.S.;Chung, J.K.
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.87-92
    • /
    • 2001
  • In automobile highway tunnels, in order to maintain a suitable environment for drivers and traffic, visibility in the tunnel must be maintained, and the concentrations of poisonous substances including carbon monoxide must be kept at or below allowable levels. For this reason, in long tunnels and tunnels with heavy traffic, ventilation facilities are installed. When the ventilation facilities are run at full capacity, the environment in the tunnel is obviously adequately maintained, but this consumes a great deal of electric power. Consequently, a central problem in highway tunnel ventilation control systems is to keep the pollution concentration at or below the allowable level, and thus provide a safe environment for traffic, while consuming as little electricity as possible. This paper introduces an operation method of longitudinal flow ventilation systems with jet-fan, dust collector and vertical ducts.

  • PDF

Deflective Behavior of Charged Particles in a Two-Stage Electrostatic Precipitator

  • Lim, Hun-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.83-91
    • /
    • 2011
  • Even if smoke, fumes, mist or dust particles are removed by electrostatic precipitators (ESPs), the occurrence of ozone, which is harmful to human body, has to be severely restricted in the indoor environments of hospitals, offices, and workshops. Therefore, the two-stage ESP generating positive corona at the ionizer is typically used because it creates less ozone than the two-stage ESP generating negative corona at the ionizer. In order to predict the collection performance and the optimal design of the two-stage ESP applied to positive high-voltage, particle concentration is experimentally investigated in this paper. In addition, particle motion within the collector section is also numerically analyzed. The positive corona discharge current of the ionizer is found to be affected by the applied voltage in the collector section but less so by the particle concentration. Particle concentration shows a minimum near the high voltage electrode of the collector section. The minimum value of the collection efficiency is almost proportional to gas velocity. When the collector length decreases, the minimum value of the collection efficiency increases. Charged particles entering the collector region are linearly deflected towards the grounded plate by an electric field. From the above experimental and numerical results, two empirical equations on the concentration ratio and the collection efficiency are derived, and are in good agreement with the experimental data.

How to Evaluate the Combined Dust Removal Efficiency of Fine Dust in the Dust Collector (집진기 미세먼지의 복합제진효율 평가방법)

  • Kang, Il-Seo;Lee, Young-su;Kim, Dong-Hyun
    • Journal of Digital Convergence
    • /
    • v.20 no.2
    • /
    • pp.339-344
    • /
    • 2022
  • It is about how much fine dust can be efficiently removed with respect to the electric dust collector used in factories and large facilities. The results of evaluating the fine dust removal efficiency are as follows. At 10,000 V, Efficiency method I showed 68.1 %, and Efficiency method II was 58.6 %, which was lower than that of Efficiency method I. At 5,000 V, Efficiency method I showed 57.6%, and Efficiency method II showed 51.6%, which was lower than Efficiency method I. At 2,500 V, Efficiency method I showed 50.3%, and Efficiency method II showed 24.4%, which was lower than Efficiency method I. In case of Efficiency method I, it is the efficiency calculated by using the dust concentration before and after passing through the filter. Efficiency method II calculated Efficiency method II to measure the efficiency a little more accurately in the environment where the air after the filter and the polluted air are mixed. Efficiency method II showed lower efficiency than Efficiency method I. As a result of the electrostatic precipitator test, the dust collecting performance was highest at 10,000 V, followed by 5,000 V and 2,500 V in that order.

Characteristics of Cyclone and Electric Dust Collection Oil Filters for Selective Removal of Fiber Tenter Air Pollutants (섬유 텐터 대기오염물질의 선택적 제거를 위한 싸이클론 및 전기 집진 오일필터의 특성)

  • Jin Ho Jung;Seung Hwan Ryu;Soon Duk Kwon;Yoon Hyun Cho
    • Textile Coloration and Finishing
    • /
    • v.35 no.4
    • /
    • pp.256-273
    • /
    • 2023
  • Among the dyeing industries, the tenter process is a process that improves the quality of fibers by drying and ironing (heat treatment) dyed fabrics, and drugs such as water repellents, antistatic agents, and fiber softeners are mainly used in these tenter processes. These drugs are vaporized in the process of treatment by high temperatures (180 ~ 230℃), and are observed in a complex form such as white smoke, oil mist, and fine dust, causing odor. To treat the complex exhaust gas at the rear end of the tenter facility, most companies operate by installing a wet scrubber and an adsorption tower alone or in parallel, but there are many problems. In particular, the insoluble oil mist at the rear end of the tenter has significantly low processing efficiency in the cleaning dust collection facility, and there is a problem in the facility by adsorption due to the occlusion phenomenon caused by the oil mist. In addition, the odor gas at the rear end of the tenter contains a lot of aldehydes, and in order to improve these various problems, a complex exhaust purification device using cyclone and electric support collector was developed. This study examined the applicability of economical and efficient technology by removing complex air pollution at the rear end of the tenter and applying improved technology than the existing technology.

Evaluation of Performance and Maintenance Cost for Roadside's Particulate Matter Reduction Devices Using Smart Green Infrastructure Technology (스마트 그린인프라 기술을 활용한 도로변 미세먼지 저감장치의 성능 및 유지·관리 비용 평가)

  • Song, Kyu-Sung;Seok, Young-Sun;Yim, Hyo-Sook;Chon, Jin-Hyung
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.25 no.4
    • /
    • pp.15-31
    • /
    • 2022
  • The Green Purification Unit System (GPUS) is a green infrastructure facility applicable to the roadside to reduce particulate matter from road traffic. This study introduces two types of GPUS (type1 and type2) and assesses the performance and maintenance costs of each of them. The GPUS's performance analysis used the data collected in November 2021 after the installation of the GPUS type1 and type2 at the study site in Suwon. The changes in the particulate matter concentration near the GPUS were measured. The maintenance cost of GPUS type1 and type2 was assessed by calculating the initial installation cost and the management and repair cost after installation. The results of the performance analysis showed that the GPUS type1, which was manufactured by combining plants and electric dust collectors, had a superior particulate matter reduction performance. In particular, type1 produced a greater effect of particulate matter reduction in the time with a high concentration (50㎍/m3 or higher) of particulate matter due to the operation of electric dust collectors. GPUS type2, which was designed in the form of a plant wall without applying an electric dust collector, showed lower reduction performance than type1 but showed sufficiently improved performance compared to the existing band green area. Meanwhile, the GPUS type1 had three times higher costs for the initial installation than GPUS type2. In terms of costs for managing and repairing, it was evaluated that type1 would be slightly more costly than type2. Finally, this study discussed the applicability of two types of GPUS based on the result of the analysis of their particulate matter performance and maintenance cost at the same time. Since GPUS type2 has a cheaper cost than type1, it could be more economical. However, in the area suffering a high concentration of particulate matter, GPUS type1 would be more effective than type2. Therefore, the choice of GPUS types should rely on the status of particulate matter concentration in the area where GPUS is being installed.