• Title/Summary/Keyword: Electric Service

Search Result 709, Processing Time 0.032 seconds

RESISTANCE ESTIMATION OF A PWM-DRIVEN SOLENOID

  • Jung, H.G.;Hwang, J.Y.;Yoon, P.J.;Kim, J.H.
    • International Journal of Automotive Technology
    • /
    • v.8 no.2
    • /
    • pp.249-258
    • /
    • 2007
  • This paper proposes a method that can be used for the resistance estimation of a PWM (Pulse Width Modulation)-driven solenoid. By using estimated solenoid resistance, the PWM duty ratio was compensated to be proportional to the solenoid current. The proposed method was developed for use with EHB (Electro-Hydraulic Braking) systems, which are essential features of the regenerative braking system of many electric vehicles. Because the HU (Hydraulic Unit) of most EHB systems performs not only ABS/TCS/ESP (Electronic Stability Program) functions but also service braking function, the possible duration of continuous solenoid driving is so long that the generated heat can drastically change the level of solenoid resistance. The current model of the PWM-driven solenoid is further developed in this paper; from this a new resistance equation is derived. This resistance equation is solved by using an iterative method known as the FPT (fixed point theorem). Furthermore, by taking the average of the resistance estimates, it was possible to successfully eliminate the effect of measurement noise factors. Simulation results showed that the proposed method contained a sufficient pass-band in the frequency response. Experimental results also showed that adaptive solenoid driving which incorporates resistance estimations is able to maintain a linear relationship between the PWM duty ratio and the solenoid current in spite of a wide variety of ambient temperatures and continuous driving.

Optimal Voltage Regulation Method for Distribution Systems with Distributed Generation Systems Using the Artificial Neural Networks

  • Kim, Byeong-Gi;Rho, Dae-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.712-718
    • /
    • 2013
  • With the development of industry and the improvement of living standards, better quality in power electric service is required more than ever before. This paper deals with the optimal algorithms for voltage regulation in the case where Distributed Storage and Generation (DSG) systems are operated in distribution systems. It is very difficult to handle the interconnection issues for proper voltage managements, because the randomness of the load variations and the irregular operation of DSG should be considered. This paper proposes the optimal on-line real time voltage regulation methods in power distribution systems interconnected with the DSG systems. In order to deliver suitable voltage to as many customers as possible, the optimal sending voltage should be decided by the effective voltage regulation method by using artificial neural networks to consider the rapid load variation and random operation characteristics of DSG systems. The simulation results from a case study show that the proposed method can be a practical tool for the voltage regulation in distribution systems including many DSG systems.

The Design of Elliptical Dual Offset Gregorian Antenna for Satellite Communication on Ka-band (Ka대역 위성통신용 타원형 이중옵셋 그레고리안 안테나 설계)

  • Kim, Chun-Won;Cheong, Chi-Hyun;Kim, Kun-Woo;Lee, Seong-Jae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.811-818
    • /
    • 2013
  • In this paper, we have designed the elliptical dual offset gregorian antenna which can use Ka band earth station antennas in the fixed-satellite service. The structure of antenna is increasing the antenna gain by decreasing blockage areas and decreasing wind effects by shortening height of the antenna. The corrugate horn antenna for this antenna has symmetric radiation patterns and low side lobe levels that can meet ITU-R envelope. The distribution of electric field on a aperture of main reflector is calculated by an ray-tracing method that use the radiation pattern of the feed horn. The final geometric of antena is decided by choosing the distribution that comply with antenna requirement. The FEKO analysed electrical performance of this antenna. The fabricated antenna has 45.0dBi(@30.0GHz)/41.7dBi(@20.2GHz), high efficiency and low side lobe level that meet ITU-R S. 580-6 envelope.

Stochastic Estimation of Acoustic Impedance of Glass-Reinforced Epoxy Coating

  • Kim, Nohyu;Nah, Hwan-Seon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.2
    • /
    • pp.119-127
    • /
    • 2014
  • An epoxy coating applied to the concrete surface of a containment building deteriorates in hazardous environments such as those containing radiation, heat, and moisture. Unlike metals, the epoxy coating on a concrete liner absorbs and discharges moisture during the degradations process, so it has a different density and volume during service. In this study, acoustic impedance was adopted for characterizing the degradation of a glass-reinforced epoxy coating using the acoustic reflection coefficient (reflectance) on a rough epoxy coating. For estimating the acoustic reflectance on a wavy epoxy coating surface, a probabilistic model was developed to represent the multiple irregular reflections of the acoustic wave from the wavy surface on the basis of the simulated annealing technique. A number of epoxy-coated concrete specimens were prepared and exposed to accelerated aging conditions to induce an artificial aging degradation in them. The acoustic impedance of the degraded epoxy coating was estimated successfully by minimizing the error between a waveform calculated from the mathematical model and a waveform measured from the surface of the rough coating.

A study on the Characteristics of Electric Fire (I) (전기화재의 특성고찰 연구(I))

  • Jang, Jeong-Tae
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.318-326
    • /
    • 2009
  • 우리나라의 화재 발생건수를 살펴보면, 1986년까지는 매년 1만건을 조금 상회하는 완만한 증가추세였으나, 1994년에는 2만건을 초과하였고, 1998년에 3만건을 넘었으며, 2007년부터는 4만건 이상으로 이제 5만 여건을 목전에 두고 있다. 특히 최근 9년간(2000-2008)의 화재발생은 연평균 36,635건, 연평균 재산피해액 190,791백만원이었으며, 전기화재의 경우, 총화재 발생건수 대비시, 1985년 34%, 1994년 39%로 계속 30%이상의 점유율을 보이다가 2006년 29.6%로 20%대로 진입하여 2007년 22.1%이며, 2008년은 총화재 발생 49,631건, 재산피해액 383,141백만원이다. 따라서 전기로 인한 화재는 22.8%인 11,308건, 재산피해액은 28%인 107,459백만원이었으며 전기화재의 최근 9년간 연평균 발생건수는 10,853건으로 매년 만 여건씩 발생하면서 59,980백만원의 재산 피해액을 나타내었는데, 전체 화재에 대한 전기화재 점유율은 약 30%를 나타내었고 재산피해액은 31.4%에 달하고 있어 아직까지도 전기화재는 화재발생원인의 1순위를 계속 점하고 있어, 이에 대한 분석과 대책이 절실히 요구되어 본 논문에서는 최근의 전기화재의 발생추이와 전기화재 특성을 고찰하여 이의예방 대책을 제시한다.

  • PDF

The Flicker Control by Feed-forward for Stabilization of CVCF Inverter (철도차량용 보조전원장치의 전향제어를 이용한 Flicker 제어)

  • 박채운;신형진;조국춘;원충연
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.267-272
    • /
    • 1999
  • The auxiliary power supply system fur passenger service of railway car has been developed from MA(Motor-Alternator) to CVCF Inverter (Static Inverter). Generally, a customer wants to apply tile new control method and device for auxiliary power supply of railcar However, if the auxiliary power supply is supplied to extended existing line, the maintenance cost of the old system is less expensive than new developed system, so, the customer specifies that the auxiliary power supply has compatibility with existing one completely. At that time, the hardware is nearly same as existing system except small changes of accessories for better performance. This paper describes the flicker control using feed-forward method of auxiliary power supply system for new 50 electric railcars, which are delivered to Korean National Railroad (KNR) Kwa-chon Line. The existing power supply system has damping resistor box to stabilize the DC input (1.5 ㎸). At this time, for better system efficiency the new system has not include resistor box but new control method including feed-forward control is applied. This control algorithm realizes the better stabilization of input power compared to the result of the existing system, which includes resistor box

  • PDF

Temperature Measurement System for Refrigerated Vehicle (냉동차량을 위한 온도 측정 시스템)

  • Lim, Yong-Jin;Kim, Jung-Hwan;Lim, Joon-hong
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.159-163
    • /
    • 2019
  • The food service industry has been grown due to improvement of living standards. In addition, the demand for frozen food delivery is increasing day by day at online/offline and the refrigerated vehicles are used in most of these food distributions. One of the most important factors in a refrigerated car is to measure the temperature accurately. Conventional temperature recording systems are generally connected directly to temperature sensor modules. Since the temperature data are transmitted to the temperature recorder by using the electric wire, there is a disadvantage that the resistance error must be compensated according to the cable length. In this paper, we propose a method to correct errors due to cable resistance using digital processing and CAN (Controller Area Network) communication. We use PT-1000 platinum sensor to increase the accuracy of the temperature measurement.

Analyzing Online Customer Reviews for the Hotel Classification in Vietnam

  • NGUYEN, Ha Thi Thu;TRAN, Tuan Minh;NGUYEN, Giang Binh
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.8
    • /
    • pp.443-451
    • /
    • 2021
  • The classification standards for hotels in Vietnam are different from many other hotel classification standards in the world. This study aims to analyze customer reviews on the TripAdvisor website to develop a new algorithm for hotel rating that is independent of Vietnam's hotel classification standards. This method can be applied to individual hotels, or hotels of a region or the whole country, while online booking sites only rate individual hotels. Data was crawled from TripAdvisor with 22,287 reviews of 5 cities in Vietnam. This study used a statistical model to analyze the review dataset and build an algorithm to rate hotels according to aspects or hotel overall. The results have less rating deviation when compared to the TripAdvisor system. This study also supports hotel managers to regularly update the status of their hotels using data from customer reviews, from which, managers can strategize long-term solutions to improve the quality of the hotel in all aspects and attract more travelers to Vietnam. Moreover, this method can be developed into an automatic system to rate hotels and update the status of service quality more quickly, thus, saving time and costs.

Static behavior of bolt connected steel-concrete composite beam without post-cast zone

  • Xing, Ying;Zhao, Yun;Guo, Qi;Jiao, Jin-feng;Chen, Qing-wei;Fu, Ben-zhao
    • Steel and Composite Structures
    • /
    • v.38 no.4
    • /
    • pp.365-380
    • /
    • 2021
  • Although traditional steel-concrete composite beams have excellent structural characteristics, it cannot meet the requirement of quick assembly and repair in the engineering. This paper presents a study on static behavior of bolt connected steel-concrete composite beam without post-cast zone. A three-dimensional finite element model was developed with its accuracy and reliability validated by available experimental results. The analysis results show that in the normal service stage, the bolt is basically in the state of unidirectional stress with the loss of pretightening can be ignored. Parametric studies are presented to quantify the effects of the post-cast zone, size and position of splicing gap on the behavior of the beam. Based on the studies, suggested size of gap and installation order were proposed. It is also confirmed that optimized concrete slab in mid-span can reduce the requirement of construction accuracy.

Stochastic Gradient Descent Optimization Model for Demand Response in a Connected Microgrid

  • Sivanantham, Geetha;Gopalakrishnan, Srivatsun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.1
    • /
    • pp.97-115
    • /
    • 2022
  • Smart power grid is a user friendly system that transforms the traditional electric grid to the one that operates in a co-operative and reliable manner. Demand Response (DR) is one of the important components of the smart grid. The DR programs enable the end user participation by which they can communicate with the electricity service provider and shape their daily energy consumption patterns and reduce their consumption costs. The increasing demands of electricity owing to growing population stresses the need for optimal usage of electricity and also to look out alternative and cheap renewable sources of electricity. The solar and wind energy are the promising sources of alternative energy at present because of renewable nature and low cost implementation. The proposed work models a smart home with renewable energy units. The random nature of the renewable sources like wind and solar energy brings an uncertainty to the model developed. A stochastic dual descent optimization method is used to bring optimality to the developed model. The proposed work is validated using the simulation results. From the results it is concluded that proposed work brings a balanced usage of the grid power and the renewable energy units. The work also optimizes the daily consumption pattern thereby reducing the consumption cost for the end users of electricity.