• Title/Summary/Keyword: Electric Rates

Search Result 443, Processing Time 0.03 seconds

Reynolds Number Effect on Regenerative Pump Performance in Low Reynolds Number Range

  • Horiguchi, Hironori;Yumiba, Daisuke;Tsujimoto, Yoshinobu;Sakagami, Masaaki;Tanaka, Shigeo
    • International Journal of Fluid Machinery and Systems
    • /
    • v.1 no.1
    • /
    • pp.101-108
    • /
    • 2008
  • The effect of Reynolds number on the performance of a regenerative pump was examined in a low Reynolds number range in experiment. The head of the regenerative pump increased at low flow rates and decreased at high flow rates as the Reynolds number decreased. The computation of the internal flow was made to clarify the cause of the Reynolds number effect. At low flow rates, the head is decreased with increasing the Reynolds number due to the decrease of the shear force exerted by the impeller caused by the increase of leakage and hence local flow rate. At higher flow rates, the head is increased with increasing the Reynolds number with decreased loss at the inlet and outlet as well as the decreased shear stress on the casing wall.

Studies on the culture of bovine nuclear transplant embryos derived in vitro fertilization (체외수정 유래 소 핵이식란의 배양에 관한 연구)

  • Hwang, Woo-suk;Jo, Choong-ho
    • Korean Journal of Veterinary Research
    • /
    • v.35 no.1
    • /
    • pp.179-185
    • /
    • 1995
  • The fusion rates of nuclear transplant embryos with various DC voltage were 55.6-79.2%. The significantly higher fusion rates of nuclear transplant embryos were achieved at the electric field strenght of DC 1.0-2.0kV/cm(72.0-79.2%) than DC 0.75kV/cm(55.6%, P<0.05). No significant differences in the percentage of embryos that cleaved(48.1, 55.4 and 42.6% respectively) and the percentage of cleaved embryos that developed to morulae/blastocyst(1.9, 5.3 and 1.9% respectively) could be found among the three types of in vitro culture system (Granulosa cell, BOEC co-culture and SOF, P>0.01). The age of the recipient cytoplast(30 vs 40hr) had no effect on the fusion rates and the rates of cleavage development(36.9 vs 44.1%, P>0.01).

  • PDF

Effect of Applied DC Electric Fields in Flame Spread over Polyethylene-Coated Electrical Wire (폴리에틸렌 피복전선 화염의 전파에 영향을 미치는 직류전기장의 인가 효과에 관한 실험적 연구)

  • Jin, Young-Kyu;Kim, Min-Kuk;Park, Jeong;Chung, Suk-Ho;Yun, Jin-Han;Keel, Sang-In
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.3
    • /
    • pp.321-330
    • /
    • 2011
  • We experimentally investigated the effect of applied DC electric fields on the flame spread over polyethylene-coated electrical wire. The flame-spread rates over electrical wire with negative and positive DC electric fields from 0 to ${\pm}7$ kV were measured and analyzed. We compared the results for DC electric fields with previous results for AC electric fields. We explored whether or not various flame shapes could be obtained with DC electric fields and the main reason for the flame-spread acceleration, particularly at the end of the electrical wire, for AC electric fields. We found that DC electric fields do not significantly affect the flame-spread rates. However, the flame shape is mildly altered by the ionic wind effect even for DC electric fields. The flame-spread rate is relevant to the flame shape and the slanted direction in spite of the mild impact. A possible explanation for the flame spread is given by a thermal-balance mechanism and fuel-vapor jet.

Smart Panel Board for EV Standard Chargers and Its Control Method (전기자동차 완속충전기용 스마트 분전반 및 그 제어방법)

  • Kim, Myeong-Soo;Hong, Soon-Chan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.511-521
    • /
    • 2014
  • This study proposes an electric vehicle (EV) smart panel board and its control method on the basis of charging scheduling. The proposed system consists of batteries, a three-phase battery charger, three single-phase inverters, transfer switches for electric power distribution, and a controller. The three-phase battery charger usually charges the batteries at midnight when electric rates are cheap and in light load. When the electric power consumption of the EV standard chargers connected to one phase of the power line is relatively large or when a blackout occurs, the electric power stored in the battery is supplied by discharging through the inverters to the EV standard chargers. As a result, the value of peak load and the charging electric power quantity supplied from a utility grid are reduced, and the current unbalance is improved. The usefulness of the proposed system is confirmed through simulations, experiments, and case studies.

Effect of Particle Aggregation on Dynamic Response of An Electrorheological Fluid in Shear Mode (전단 유동을 하는 전기유변 유체의 동적 응답에 입자 응집이 미치는 영향)

  • Choi, Byung-Ha;Nam, Yun-Joo;Park, Myeong-Kwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2885-2889
    • /
    • 2007
  • In this study, the effect of particle aggregation on dynamic response time of Electrorheological (ER) fluid is investigated. The particle aggregation time is defined as the time interval between the application of the field and the formation of the first chain bridging the two electrodes. The dynamic response times of an ER fluid sheared between two concentric cylinders have been obtained under two different experimental conditions: the one is that the electric field is induced before shearing, and the other is that the electric field is induced after shearing. From the difference between two response times, the particle aggregation times are determined under various electric fields and shear rates. The experimental results show that the aggregation rate is decreased with an increase of shear rate, while electric field has little effect on it. Therefore, it is verified that the hydrodynamic force hinders the formation of chain-like structures.

  • PDF

Transient Response of an Electrorheological Fluid in Shear Flow (전단 유동 하에서 전기유변유체의 과도응답 특성)

  • Choi, Byung-Ha;Nam, Yun-Joo;Park, Myeong-Kwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.6
    • /
    • pp.411-417
    • /
    • 2009
  • The transient shear stress response of an electrorheological fluid is investigated experimentally. The characteristic time constants of an electrorheological fluid sheared between two concentric cylinders were obtained under various electric field strengths and shear rates. Also, two experimental modes are adopted to investigate the effect of the shear flow on the dynamic behavior of the fluid; one is that the electric field is induced before shearing, and the other is the electric field is induced after shearing. From the difference in the response time between two modes, the cluster formation time were obtained. The response times were decreased with the increase of the shear rate, irrelatively of the electric field strength. The cluster formation time were monotonically increased with increase of shear rate, and thereafter, were converged with a certain value.

A study of discharge characteristics by Xe content rates of AC PDP (Xe gas %에 따른 AC PDP의 방전특성 고찰)

  • Lee, Don-Kyu;Lee, Sun-Hong;Lee, Ho-Jun;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.148-150
    • /
    • 2003
  • We investigated the discharge characteristics by adding a little $N_2$ to the mixed gas, Ne+Xe+He, as the working gas in AC PDP. In this study, it is founded that the luminance and efficiency of the panel included a little $N_2$ increased and the discharge firing voltage is reduced. In addition, the characteristics of jitter and delay time are investigated.

  • PDF

Dosimetry for Resonance-Based Wireless Power Transfer Charging of Electric Vehicles

  • Park, Sang-Wook
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.129-133
    • /
    • 2015
  • This paper presents the dosimetry of a resonance-based wireless power transfer (RBWPT) system for electric vehicles applications. The compact RBWPT system is designed to transfer power at 150-mm distance. The electric and magnetic fields generated by the RBWPT system and the specific absorption rate in the human body model, which stands around the system, are calculated. These analyses are conducted in two cases: the alignment and the misalignment between the transmitter and the receiver. The matching loops are adjusted to maximize the power transfer efficiency of the RBWPT system for the misalignment condition. When the two cases were compared for the best power transfer efficiency, the specific absorption rates (SAR) in the misalignment case were larger than those in the alignment case. The dosimetric results are discussed in relation to the international safety guidelines.

Development of Modified Product Consistency Test

  • Park, Kwansik;Jiawei Sheng;Maeng, Sung-Jun;Song, Myung-Jae
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.391-396
    • /
    • 1998
  • Modified product Consistency Test (M-PCT) has been developed as an alternative to other existing methods in determining the leachability of glass. M-PCT, the leaching method, is a hybrid of MCC-l and PCT, but can provide quicker sample preparation. Larger diameter glass sample (1.0-2.0 mm) than in the PCT method can be used so that the glass beads are more easily produced and cleaned. From the M-PCT, the total mass loss (ML) of glass, the normalized elemental release rate (NLi), pH value of leachate have been obtained. For some selected glasses in which leaching rates have been known, their chemical durablility have been tested using the M-PCT method. The results are compared to the literature data for the glasses. It is found that M-PCT method is reasonable and suitable in determining the leachability of Low and Intermediate level Radioactive Waste glass form, such as the pH, elemental loss and total mass loss.

  • PDF

Electrorheological Behavior of the Hollow PANI Sebacate Suspension upon Application of the Electric Field

  • Choi, Ung-Su;Lee, Sang-Soon
    • KSTLE International Journal
    • /
    • v.10 no.1_2
    • /
    • pp.13-16
    • /
    • 2009
  • The electrorheological(ER) behavior of hollow polyaniline(PANI) sebacate suspension in silicone oil was investigated by varying the electric fields and shear rates, respectively. The hollow PANI sebacate susepnsion acted as a typical Bingham fluid caused by the polarizability of an amide polar group and showed shear yield stress due to the formation of chains upon application of an electric field. The shear stress for the hollow PANI sebacate suspension exhibited an electric field power of 1.24. On the basis of the experimental results, the newly synthesized hollow PANI sebacate suspension was found to be an anhydrous ER fluid.