• Title/Summary/Keyword: Electric Rates

Search Result 444, Processing Time 0.03 seconds

Apparent Viscosity Properties of Electro-Rheological Fluid by Using Rotational Viscometer (회전식 점도계를 이용한 ERF의 겉보기 점도 특성)

  • 장성철;이진우;김태형;박종근
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.196-201
    • /
    • 2001
  • Electro-Rheological(ER) fluids change their apparent viscosity according to the electric field strength. Therefore, there are many practical applications using the ER fluids. ER effect on the dispersive system of polarizable fine powder/dielectric oil has been investigated. The electrical and rheological properties of starch based ER fluid were reported. Yield stress of the fluids were measured on the couette cell type rheometer as a function of electric fields, particle concetrations, and temperatures. The electric field is applied by high voltage DC power supply, The outer cup is connected to positive electrode(+) and the bob becomes ground(-). And the temperatures the viscosity(or shear stress) versus shear rates were measured. In this experiment shear rates were increased from 0 to 200s$^{-1}$ in 2 minutes. This thesis presents Bingham properties of ER fluids subjected to temperature variations. The temperature dependence of the viscosity was determined for ER fluids consisting of 35 weight % starch particles in automatic transmission oil.

  • PDF

A Study on the Program for Estimation of Electric Rates and the Analysis for Power Consumption in Complex Consumer (복합다용도 수용가의 전력소비특성 분석 및 전기요금 산정프로그램 개발)

  • Kim, Se-Dong;Yoo, Sang-Bong;Ki, Yoo-Kyung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.103-107
    • /
    • 2014
  • Together with housings, general buildings and industrial facilities, multi-purpose complexes are equipped with various and special equipment. They are often used by many unspecified people, which causes an increase in annual electricity consumption. Because of this, a great amount of money has been spent for electric charge, far more in excess of the budget, so a reasonable electricity rate needs to be estimated. In this study, we surveyed the power consumption, average power use, and annual electricity bill of multi-purpose complexes in the past five years. To see the general tendency of the survey, we conducted a statistical analysis with such parameters as average, maximum, and minimum values. Through regression analysis, we could see the trend of the survey in linear way. Based on the survey, we have developed an electric-rate calculation program to estimate the next year's budget on electricity.

Blastomeres Fusion of 2-cell Mouse Embryos by Electric Stimulation (전기자극법에 의한 생쥐 2세포기란의 분할구 융합에 관한 연구)

  • Yang, B.Y.;Han, S.I.;Kim, C.I.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.18 no.1
    • /
    • pp.35-40
    • /
    • 1991
  • To find out the suitable method for blastomeres fusion of mouse 2-cell embryo using electric stimuli, these studies were carried out with various voltages (1.0 KV, 1.2 KV, 1.5 KV, 1.7 KV and 2.0KV), pulse duration times($50{\mu}\;sec$, $75/{\mu}\;sec$, $100{\mu}\;sec$) and different fusion solutions. In addition, the fused embryos were cultured for 72-80hr to observe their subsequent development. These results were summarized as follows: 1. The proportion of the fused embryos were 50.8%(34/67), 60.7%(34/56), 70.6%(48/68), 66.7% (48/72) and 85.3% (58/68) after stimuli of 1.0KV, 1.2KV, 1.5KV, 1.7KV and 2.0KV for $100{\mu}\;sec$ with 2 times, and the electric stimulation at 2.0KV(85.3%) was the most effective voltage on the blastomere fusion. 2. For in vitro development, blastocysts of the fused embryos were cultured for 72-80hrs in $M_{16}$ medium. The group(52.1%) treated with 1.5KV for $100{\mu}\;sec$ with 2 times showd higher development rates than those any other group. However, these results were not corresponded to those of the rates of blastomere fusion. 3. There were no significant differences among the rates of blastomeres fusion to 50(70.6%), 75(71.9%), and 100(78.0%) ${\mu}sec$ stimulation at 1.5KV with two times. However, the development rates of the fused embryo in vitro were 52.1%(25/48), 28.3%(13/46) and 9.4%(3/32) at the above conditions, and the development rates of fused embryo increased as the pulse duration times increased. 4. The rates of the blastomeres fusion were 38.9% (28/72) or 70.6% (48/68) in electrolyte (PBS) or non-electrolyte(0.3M mannitol) solution. The development rates of the fused embryo were 32.1% (9/28) or 52.1%(25/48) in the above fusion solutions, and non-electrolyte-treated group showed higher development rates of embryo than that of electrolyte-treated group.

  • PDF

Synthesis and Electrorheological Effect of the Suspensions Composed of Nano Sized Hollow Polyaniline Derivatives

  • Choi Ung-Su
    • KSTLE International Journal
    • /
    • v.7 no.1
    • /
    • pp.18-21
    • /
    • 2006
  • The electrorheology of hollow PANI derivative suspensions in silicone oil was investigated by varying the electric fields and shear rates, respectively. The hollow PANI derivative susepnsions showed a typical electrorheological (ER) response caused by the polarizability of an amide polar group and shear yield stress due to the formation of chains upon application of an electric field. The shear stress for the hollow PANI succinate suspension exhibited an electric field power of 0.67. On the basis of the experimental results, the newly synthesized hollow PANI derivative suspensions were found to be an anhydrous ER fluid.

Electrical and Rheological Properties of Chitosan Malonate Suspension

  • Choi, Ung-su
    • KSTLE International Journal
    • /
    • v.4 no.1
    • /
    • pp.14-17
    • /
    • 2003
  • The electrical and rheological properties of a chitosan malonate suspension in silicone oil was investigated by varying the electric fields, volume fractions of particles, and shear rates, respectively, The chitosan malonate susepnsion showed a typical electrorheological (ER) response caused by the polarizability of an amide polar group and shear yield stress due to the formation of multiple chains upon application of an electric field. The shear stress fur the suspension exhibited a linear dependence on the volume fraction and an electric field power of 1.88. On the basis of the experimental results, the newly synthesized chitosan malonate suspension was found to be an anhydrous ER fluid.

A Study on Combustion Characteristics and Evaluating of RDFs(Refused Derived Fuels) from Mixture of Petrochemical Wastewater Sludge and Organic Matters (석유화학폐수슬러지와 유기성 폐기물 혼합에 의한 연소특성 및 고형연료 폐기물화 재활용에 관한 연구)

  • Han, Young-Rip;Choi, Young-Ik
    • Journal of Environmental Science International
    • /
    • v.24 no.2
    • /
    • pp.237-244
    • /
    • 2015
  • This objectives of research are to figure out combustion characteristics with increasing temperature with petrochemical sludge by adding wasted organic matters which are waste electric wire, anthracite coal and sawdust, and to exam heating value and ignition temperature for using refused derived fuels(RDFs). After analyzing TGA/DTG, petrochemical sludge shows a rapid weight reduction by vaporing of inner moisture after $170^{\circ}C$. Gross weight reduction rate, ignition temperature and combustion rates represent 68.6%, $221.9^{\circ}C$ and 54.1%, respectively. In order to assess the validity of the RDFs, the petrochemical sludge by adding wasted organic matters which are waste electric wire, anthracite coal and waste sawdust. The materials are mixed with 7:3(petrochemical sludge : organic matters)(wt%), and it analyzes after below 10% of moisture content. The ignition temperatures and combustion rates of the waste electric wire, anthracite coal and waste sawdust are $410.6^{\circ}C$, $596.1^{\circ}C$ and $284.1^{\circ}C$, and 85.6%, 30.7% and 88.8% respectively. In heating values, petrochemical sludge is 3,600 kcal/kg. And the heating values of mixed sludge (adding 30% of the waste electric wire, anthracite coal and waste sawdust) each increase up to 4,600 kcal/kg, 4,100 kcal/kg and 4,300 kcal/kg. It improves the ignition temperatures and combustion rates by mixing petrochemical sludge and organic matters. It is considered that the production of RDFs is sufficiently possible by using of petrochemical sludge by mixing wasted organic matters.

Flow Rate-Pressure Drop Characteristics of Dispersive ER Fluid According to Change of Electric Field Strength in Clearance between Parallel Plates (평행평판 간극에서 전기장의 강도변화에 따른 분산계 ER유체의 유량-압력강하 특성)

  • 장성철;염만오;김도태
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.1
    • /
    • pp.78-83
    • /
    • 2003
  • Electro-rheological(ER) fluids are suspensions in which rheological properties show an abrupt change with variation of electric fields. We modeled the parallel-plates relating to ER-Valve system and yielded shear stress according to the strength of electric field. The purpose of the present study is to examine the flow characteristics of ER fluids according to the strength of electric field between parallel-plates. Then the steady relationship between pressure drop and flow rate of the ER fluids between parallel-plates under application of an electric fields was measured. The pressure drop and flow rates of ER fluids under the application of electric fields for steady flow were measured. For the experiment, we used the ER fluids, 35w% zeolite having hydrous particles and differential pressure gauge. This test reviewed experiment for the special changes of ER fluids in the steady flow condition.

A Study on Power System Analysis Considering Special-days Load Mobility of Electric Vehicle (특수일 이동을 고려한 전기자동차 충전부하의 전력계통 영향에 관한 연구)

  • Hwang, Sung-Wook;Kim, Jung-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.253-256
    • /
    • 2016
  • In this paper, the power system with electric vehicles is analyzed considering the mobility and diffusion rate of electric vehicles in the smart grid environment. In the previous studies, load modeling and load composition rates have been researched and the results are applied to develop a new load model to explain the mobility of electric vehicles which could affect on the power system status such as power flow and stability. The results would be utilized to research and develop power system analysis methods considering movable charging characteristics of electric vehicles including movable discharging characteristics which could be affected by the diffusion progress of electric vehicles.

A Study on the Operational Optimization of Turbo-Expander Pressure Reduction System to the Natural Gas Flow Rates (천연가스 유량변화에 따른 터보팽창기 감압시스템 운전 최적화에 관한 연구)

  • Yoo, Han Bit;Kim, Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.72-79
    • /
    • 2015
  • Electricity can be generated when the natural gas passes through a turbo-expander pressure reduction system at natural gas pressure reduction stations. Efficiency of the turbo-expander depends on the ratio of the natural gas flow rates to the design flow rate of the turbo-expander. Therefore, the optimal conditions for the operation of the pressure reduction system can be determined by controlling the natural gas flow rates. In this study, we have calculated the electric energy generation depending on the natural gas flow rates at the two low-pressure reduction stations when the pressure of the natural gas is reduced from 17.5 bar to 8.5 bar and have found the optimal conditions for the turbo-expander pressure reduction system through the comparison with the calculation results. The turbo-expander generates the electric power efficiently for the high natural gas flow rates which variations are slight. The determined design flow rate of the turbo-expander has the highest coverage of the natural gas flow rates. The electricity generation is calculated as much as 9 MW(B station) and 12 MW(D station) at each pressure reduction station.

A Study on the Temperature Dependence of Electro-Rheological Fluids with Electric Field Control (전기장 제어에 따른 ER유체의 온도 의존성에 관한 연구)

  • Jang, Sung-Cheol;Park, Chang-Soo;Lee, Chan-Kyu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.3 no.2
    • /
    • pp.67-72
    • /
    • 2004
  • Electro-Rheological(ER) fluids consist of suspensions of fine polarizable particles In a dielectric oil, which upon application of an external electric field control take on the characteristics of the Bingham solid. In this study, the temperature dependence of the viscosity was Investigated for an ER fluid consisting of 35 weight % of zeolite particles in hydraulic oil 46cSt. Thermal activation analysis was performed by changing the ER fluid's temperature from $-10^{\circ}C$ to $50^{\circ}C$. According to the analysis, the activation energy for flow of the ER fluid was 79.6 kJ/mole without applying electric field. On the other hand, with the electric field of 2kV/mm, the linearity between viscosity and temperature was not existed By changing the temperatures the viscosity (or shear stress) versus shear rates were measured. In this experiment shear rates were increased from 0 to $200s^{-1}$ in 2 minutes. Generally, the hydraulic oil 46cSt will be operated at the temperature of about $40^{\circ}C$, thus, the ER fluid's electric field dependence of viscosity was examined at this temperature. Also, an influence of adding the dispersant(Carbopl 940) on ER effect was discussed.

  • PDF