• Title/Summary/Keyword: Electric Power Management

Search Result 840, Processing Time 0.032 seconds

Development of Numerical Algorithm of Total Point Method for Thinning Evaluation of Nuclear Secondary Pipes (원전 2차측 배관 감육여부 판별을 위한 Total Point Method 전산 알고리즘 개발)

  • Oh, Young Jin;Yun, Hun;Moon, Seung Jae;Han, Kyunghee;Park, Byeong Uk
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.2
    • /
    • pp.31-39
    • /
    • 2015
  • Pipe wall-thinning by flow-accelerated corrosion (FAC) and various types of erosion is a significant and costly damage phenomenon in secondary piping systems of nuclear power plants (NPPs). Most NPPs have management programs to ensure pipe integrity due to wall-thinning that includes periodic measurements for pipe wall thicknesses using ultrasonic tests (UTs). Nevertheless, thinning evaluations are not easy because the amount of thickness reduction being measured is often quite small compared to the accuracy of the inspection technique. U.S. Electric Power Research Institute (EPRI) had proposed Total Point Method (TPM) as a thinning occurrence evaluation method, which is a very useful method for detecting locally thinned pipes or fittings. However, evaluation engineers have to discern manually the measurement data because there are no numerical algorithm for TPM. In this study, numerical algorithms were developed based on non-parametric and parametric statistical method.

A Study on Consumer Protections for the Introduction of Smart Grid (스마트그리드 도입에 따른 소비자 보호 연구)

  • Kim, Hyun-Jae;Jo, Sung-Han
    • Journal of Digital Convergence
    • /
    • v.9 no.5
    • /
    • pp.1-9
    • /
    • 2011
  • The smart grid can create benefits such as the expansion of consumer choice and flexibility enhancement, adaption to future electric power industry change and the increasing use of renewable energy sources. Consumers can make a contribution to improve the overall effectiveness of system through active receptive response. They can enhance the energy consumption efficiency based on more information from service providers. The Smart Grid Promotion Act, which was enacted in April 2011, contains consumer protection provisions such as information collecting, sharing, and protection measures. On this reason, it is needed to expand promotion and education regarding the smart grid to improve the consumer awareness, and the schemes to enhance smart grid consumer acceptance should be established.

A New Voltage Balancer With Bidirectional DC-DC Converter Function for EV Charging Station (전기자동차 충전소용 양방향 DC-DC 컨버터 기능을 갖는 전압 밸런서)

  • Nam, Hyun-Taek;Kim, Sanghun;Cha, Honnyong;Kim, Heung-Geun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.5
    • /
    • pp.313-320
    • /
    • 2018
  • This study proposes a new voltage balancer with bidirectional DC-DC converter function. The proposed balancer can serve as a voltage balancer and a bidirectional DC-DC converter. Thus, the balancer can be applied to battery management systems or fast chargers in electric vehicles (EVs) charging stations while balancing bipolar DC bus voltages. The proposed system has unlimited voltage balancing range unlike the conventional voltage balancing control using a three-level DC-DC converter. A comparison of the voltage balancing range between the proposed and conventional scheme is explored to confirm this superiority. Simulation and experimental results are provided to validate the effectiveness of the proposed system.

Operation Results of the SOFC System Using 2 Sub-Module Stacks (2 모듈 스택을 이용한 SOFC 시스템 운전결과)

  • Lee, Tae-Hee
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.5
    • /
    • pp.405-411
    • /
    • 2010
  • A 5kW class SOFC cogeneration system consisted of a hot box part, a cold BOP (balance of plant) part, and a hot water reservoir. The hot box part contained a stack, a fuel reformer, a catalytic combustor, and heat exchangers. A cold BOP part was composed of blowers, pumps, a water trap, and system control units. A 5kW stack was designed to integrate 2 sub-modules. In this paper, the 5kW class SOFC system was operated using 2 short stacks connected in parallel to test the sub-module and the system. A short stack had 15 cells with $15{\times}15 cm^2$ area. When a natural gas was used, the total power was about 1.38 kW at 120A. Because the sub-modules were connected in parallel and current was loaded using a DC load, voltages of sub-modules were same and the currents were distributed according to the resistance of sub-modules. The voltage of the first stack was 11.46 V at 61A and the voltage of the second stack was 11.49V at 59A.

Parameter Identification of 3R-C Equivalent Circuit Model Based on Full Life Cycle Database

  • Che, Yanbo;Jia, Jingjing;Yang, Yuexin;Wang, Shaohui;He, Wei
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1759-1768
    • /
    • 2018
  • The energy density, power density and ohm resistance of battery change significantly as results of battery aging, which lead to decrease in the accuracy of the equivalent model. A parameter identification method of the equivale6nt circuit model with 3 R-C branches based on the test database of battery life cycle is proposed in this paper. This database is built on the basis of experiments such as updating of available capacity, charging and discharging tests at different rates and relaxation characteristics tests. It can realize regular update and calibration of key parameters like SOH, so as to ensure the reliability of parameters identified. Taking SOH, SOC and T as independent variables, lookup table method is adopted to set initial value for the parameter matrix. Meanwhile, in order to ensure the validity of the model, the least square method based on variable forgetting factor is adopted for optimizing to complete the identification of equivalent model parameters. By comparing the simulation data with measured data for charging and discharging experiments of Li-ion battery, the effectiveness of the full life cycle database and the model are verified.

Performance Evaluation of SHF Sensor for Partial Discharge Signal Detection on DC Rectifier (DC 정류기 부분방전 신호검출을 위한 SHF 센서의 성능평가)

  • Jung, Ho-Sung;Park, Young;Na, Hee-Seung;Jang, Soon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.1056-1060
    • /
    • 2012
  • Online monitoring system is becoming an essential element of railway traction system for utilized to condition based malignance management and various techniques currently employed in railway traction system. Among the various techniques, it is efficient to detect partial discharge signals by electromagnetic wave detection in order to detect insulation fault of rectifier. Although VHF (Very High Frequency), UHF (Ultra High Frequency) sensors were adopted to detect partial discharge of power facilities, due to characteristics of urban railway, excessive noise occurs from 500 MHz to 1.5 GHz on UHF bandwidth. In this paper a new measurement system able to monitoring the conditions of power facilities on DC substation in metro was studied and set up. The system uses UHF sensors to measure the partial discharge of the rectifier due to electric faulting and dielectric breakdown. Comparison and estimation for performance of SHF sensor which had devised to detect partial discharge signal of urban railway rectifier has conducted. In order to estimate performance of SHF sensor, we have compared the sensor with existing UHF sensor on sensitivity upon frequency bandwidth generated by pulse generator, and also we have verified performance of the SHF sensor by detection results of partial discharge signal from urban railway rectifier.

Fluid Analysis for Verifying Interrupting Capability of UHV GCB (초고압 GCB의 차단성능 검증을 위한 유동해석)

  • Kim, D.S.;Seo, K.B.;Song, W.P.;Chung, Y.H.;Kim, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.19-21
    • /
    • 2002
  • Recently, it has become more competitive to take larger market share among domestic companies manufacturing high-power apparatus. Unfortunately, the size of total market in this field is being smaller than before because the business of transmission and distribution of electric power is being shifted from government control to private management. To save this situation, we are trying to develop new high-voltage Gas Insulated Switchgear for export such as 245kV GIS and 300kV GIS. It is very important to make GIS compact size to have international competitiveness against European companies. By reducing GIS's dimensions same as 170kV class, we expect to launch abroad successfully. Many factors should be considered to achieve good performance during short-circuit making-breaking. Analysis on cold gas flow is one method widely used to evaluate small-current interruption. Through this analysis, we can examine the dielectric characteristics at the weak points in the circuit-breaker. In this paper, we describe the results of cold-gas flow analyses on 245kV and 300kV circuit-breakers.

  • PDF

COMBUSTION CHARACTERISTICS OF WASTE-PYROLYSIS GASES IN AN INTERNAL COMBUSTION ENGINE

  • Shudo, T.;Nagano, T.;Kobayashi, M.
    • International Journal of Automotive Technology
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 2003
  • Wastes such as shredder dust of disposed vehicles can be decomposed into low calorific flammable gases by Pyrolysis gasification. A stationary electric Power generation using an internal combustion engine fuelled with the waste-pyrolysis gas is an effective way to ease both waste management and energy saving issues. The waste-pyrolysis gas mainly consists of H$_2$, CO, $CO_2$ and $N_2$. The composition and heating value of the gas generated depend on the conversion process and the property of the initial waste. This research analyzed the characteristics of the combustion and the exhaust emissions in a premixed charge spark ignition engine fuelled with several kinds of model gases, which were selected to simulate the pyrolysis-gases of automobile shredder dusts. The influences of the heating value and composition of the fuel were analyzed parametrically. Furthermore, optical analyses of the combustion flame were made to study the influence of the fuel's inert gas on the flame propagation.

Guideline-based Evaluation of Human Machine System Environment with the Advanced Information Display (디지털 정보표시 환경의 지침 기반 평가 기술)

  • Cha, Woo-Chang
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.99-102
    • /
    • 2007
  • The analog typed interface of main control room in nuclear power plant(NPP) is gradually being replaced to the one suitable for the digital environment. SKN 3,4 is currently developed in such a way to employ digitalized displays and controls such as computerized procedure system(CPS), large display panel(LDP), and Soft control. The main control room (MCR) of the SKN3, 4 was designed based on the human factors guidelines, which somehow lack of the confidence for the rapidly the developed guidelines needs to extend to the one to apply for the total digital environment including task environment, hardware and workstation. In order to achieve the research objectives, tremendous guidelines and technical papers related to evaluation issues of digital environment has been collected, analyzed and transformed to electric database forms and then built on database management system to retrieve the appropriate isues for the practical usage of evaluators-in-field.

A Study on a Charge-Change According to the Introduction of RPS(Renewable Portfolio Standard) (RPS 재도 도입에 따른 전기요금 변화에 관한 연구)

  • Hong, Hee-Jung;Kim, Gwang-Mo;Kim, Gang-Won;Han, Seok-Man;Kim, Bal-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.429-431
    • /
    • 2008
  • 기후변화협약 체결 당시 개발도상국으로 분류되어 있던 우리나라는 현재 온실가스 감축의무를 부담하지 않고 있으나, 우리나라의 CO2 배출량 및 배출량 증가율을 고려해 볼 때, 제2차 공약기간(2012년$\sim$2016년) 동안의 온실가스 감축의무 부담이 예견되고 있다. 온실가스 감축의무를 이행하기 위하여 정부는 2012년부터 RPS(Renewable Portfolio Standard) 제도를 도입을 고려하고 있다. 신재생에너지전원의 비중을 설비용량의 5%(발전량의 7%)까지 확대를 예상하여, 본 연구에서는 RPS 제도를 도입을 고려할 때 전원구성의 변화를 GATE -PRO(Generation And Transmission Expansion PROgram)모형을 이용하여 알아본 후, 이로 인하여 전기를 사용하는 용도에 따라 6가지 종별로 구분하는 현행 전기요금체계에 미치는 영향에 대하여 알아보고자 한다.

  • PDF