• Title/Summary/Keyword: Electric Power Efficiency

Search Result 1,534, Processing Time 0.025 seconds

QoE-aware Energy Efficiency Maximization Based Joint User Access Selection and Power Allocation for Heterogeneous Network

  • Ji, Shiyu;Tang, Liangrui;Xu, Chen;Du, Shimo;Zhu, Jiajia;Hu, Hailin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.10
    • /
    • pp.4680-4697
    • /
    • 2017
  • In future, since the user experience plays a more and more important role in the development of today's communication systems, quality of experience (QoE) becomes a widely used metric, which reflects the subjective experience of end users for wireless service. In addition, the energy efficiency is an increasingly important problem with the explosive growth in the amount of wireless terminals and nodes. Hence, a QoE-aware energy efficiency maximization based joint user access selection and power allocation approach is proposed to solve the problem. We transform the joint allocation process to an optimization of energy efficiency by establishing an energy efficiency model, and then the optimization problem is solved by chaotic clone immune algorithm (CCIA). Numerical simulation results indicate that the proposed algorithm can efficiently and reliably improve the QoE and ensure high energy efficiency of networks.

Analysis of TV Standby Power for Development of Energy Efficiency Standard (TV 대기모드 효율기준 개발을 위한 대기전력 실태 분석)

  • Kim, Ik-Pyo;Ro, Kyoung-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.18-26
    • /
    • 2012
  • Recently, there have been suggestions that power factor should be considered to increase the efficiency of electric power supply when evaluating the performance of the electric appliances in standby mode and the related studies have been conducted to improve the efficiency standard of standby power. But, they lack the analysis of the standby power characteristics with the changes of power factor. This study is conducted to analyze the standby power characteristics of TV which is a typical home appliance and reaches a conclusion that the apparent power can be a more reasonable index which reflects the efficiency of electric power supply. It is also found that LED TVs show the best performance in standby mode. Moreover, an example to set standby power standards on TVs to be applied in the future is suggested, considering the energy efficiency policies for appliances.

A Study on the Energy Saving and Electric Fire Prevention was Caused by with Interception of Standby Electric Power (대기전력차단으로 인한 에너지절약과 전기화재예방에 관한 연구)

  • Kim, Man-Gun;Lim, Seong-Jin;Lee, Chang-Woo
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.66-73
    • /
    • 2008
  • In this research, the electric power consumptions of the electrical machinery and appliances selected in the Seoul division of Korea Electrical Safety Corporation were measured. The power-saving efficiency was investigated by comparing the amounts of the reserved electric power when the Saver was on or off through measuring that of the reserved electric power before and after equipping the selected appliances with the Saver, a cutoff of the reserved electric power. As a result, the power-saving efficiency was around 18% when the Saver was installed. It can be ascribed to the removal of the source wasting electrical energy. Furthermore, by blocking the reserved electric power, the electric fire can be originally prevented and also the life time of the electrical machinery and appliances can be postponed.

  • PDF

STEADY-STATE OPTIMIZATION OF AN INTERNAL COMBUSTION ENGINE FOR HYBRID ELECTRIC VEHICLES

  • Wang, F.;Zhang, T.;Yang, L.;Zhuo, B.
    • International Journal of Automotive Technology
    • /
    • v.8 no.3
    • /
    • pp.361-373
    • /
    • 2007
  • In previous work, an approach based on maximizing the efficiency of an internal combustion engine while ignoring the power conversion efficiency of other powertrain components, such as the electric motor and power battery or ultracapacitor, was implemented in the steady-state optimization of an internal combustion engine for hybrid electric vehicles. In this paper, a novel control algorithm was developed and successfully justified as the basis for maximal power conversion efficiency of overall powertrain components. Results indicated that fuel economy improvement by 3.9% compared with the conventional control algorithm under China urban transient-state driving-cycle conditions. In addition, using the view of the novel control algorithm, maximal power generation of the electric motor can be chosen.

Maximum Efficiency Point Tracking Control Algorithm for Improving Electric Power Transmission Efficiency between Photovoltaic Power Generating system and the Grid (태양광발전시스템과 계통간의 전력 전송 효율 개선을 위한 최대효율점 추적 제어 알고리즘)

  • Kwon, Cheol-Soon;Kim, Kwang Soo;Do, Tae Young;Park, Sung-Jun;Kang, Feel-Soon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.3
    • /
    • pp.342-348
    • /
    • 2013
  • It proposes an efficient control algorithm to increase electric power transmission efficiency between photovoltaic power generating system and the grid. The main controller finds a maximum efficiency condition by considering the quantity of power generated from PV arrays, the number of inverters, and efficiency of PV inverter. According to the condition, a relay board arranges a point of contract of PV arrays. By the disposition of PV arrays, it assigns the optimized power on each PV inverter. Operational principle of the proposed maximum efficiency point tracking algorithm is given in detail. To verify the validity of the proposed approach, computer-aided simulation and experiment carried out.

A Feasibility Study on Adopting Sliding Pressure Operation for Drum Type Boiler

  • Baek, SeHyun;Kim, HyunHee;Park, SangBin;Kim, YoungJoo;Park, Hoyoung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.3
    • /
    • pp.403-407
    • /
    • 2016
  • In general, drum-type boilers are designed for base load duty and applied under constant pressure operation mode. Recently, however conditions often occur that even drum-type boilers have to operate at partial load conditions. A feasibility study on adopting the sliding pressure operation for drum-type boiler was conducted, and corresponding performance changes and effects on the equipment were analyzed by utilizing a process simulation model. As a result, the conclusion was reached that drum type boilers are able to adopt the sliding pressure operation and can improve of net efficiency at part load operation in spite of the Rankine cycle efficiency reduction due to the decreases in main steam pressure. Because of thank to improvement of high pressure turbine stage-1 internal efficiency and power savings of boiler feed water pump. The sliding pressure operation is advantageous in terms of stress level relief for boiler tube as well as maintaining the rating steam temperature at part load condition. However, cautions are required because the drum boilers have poor dynamic response characteristics which may get worse during the sliding pressure operation.

Operational Characteristics of High-Performance kW class Alkaline Electrolyzer Stack for Green Hydrogen Production

  • Choi, Baeck B.;Jo, Jae Hyeon;Lee, Taehee;Jeon, Sang-Yun;Kim, Jungsuk;Yoo, Young-Sung
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.302-307
    • /
    • 2021
  • Polymer electrolyte membrane (PEM) electrolyzer or alkaline electrolyzer is required to produce green hydrogen using renewable energy such as wind and/or solar power. PEM and alkaline electrolyzer differ in many ways, instantly basic materials, system configuration, and operation characteristics are different. Building an optimal water hydrolysis system by closely grasping the characteristics of each type of electrolyzer is of great help in building a safe hydrogen ecosystem as well as the efficiency of green hydrogen production. In this study, the basic operation characteristics of a kW class alkaline water electrolyzer we developed, and water electrolysis efficiency are described. Finally, a brief overview of the characteristics of PEM and alkaline electrolyzer for large-capacity green hydrogen production system will be outlined.

Economic Feasibility of Conversion of the Pulverized Coal Firing Boiler using Korean Anthracite into a Circulating Fluidized Bed Boiler (국내탄용 미분탄 보일러의 순환유동층 전환에 따른 경제성 평가)

  • Lee, Jong-Min;Kim, Dong-Won;Kim, Jae-Sung;Kim, Jong-Jin;Kim, Hyeng-Seok
    • Korean Chemical Engineering Research
    • /
    • v.44 no.5
    • /
    • pp.489-497
    • /
    • 2006
  • The economical efficiency of conversion of the PC (pulverized coal) firing boiler to the CFB (circulating fluidized bed) boiler which used Koran anthracite as fuel was evaluated. The economic feasibility study was also carried out with regard to maintenance of the existing PC boiler. The sensitivity of economical efficiency with variation of the electric power and coal industry and the policy of government was analyzed and compared. As a results of the evaluation, the economical efficiency of maintenance of the existing PC boiler was higher than that of conversion to the CFB boiler because of the special policy of the government for Korean anthracite. However, the conversion to the CFB boiler was more economically attractive from a point of view of effective use of energy resources and future electric power industry. Additionally, the fund support for electric power industry using Korean anthracite would be effective as changing the policy of the government.

Periodically Poled BaTiO3: An Excellent Crystal for Terahertz Wave Generation by Cascaded Difference-frequency Generation

  • Li, Zhongyang;Yuan, Bin;Wang, Silei;Wang, Mengtao;Bing, Pibin
    • Current Optics and Photonics
    • /
    • v.2 no.2
    • /
    • pp.179-184
    • /
    • 2018
  • Terahertz (THz) wave generation by periodically poled $BaTiO_3$ (PPBT) with a quasi-phase-matching (QPM) scheme based on cascaded difference-frequency generation (DFG) is theoretically analyzed. The cascaded DFG processes comprise cascaded Stokes and anti-Stokes processes. The calculated results indicate that the cascaded Stokes processes are stronger than the cascaded anti-Stokes processes. Compared to a noncascaded Stokes process, THz intensities from $20^{th}$-order cascaded Stokes processes increase by a factor of 30. THz waves with a maximum intensity of $0.37MW/mm^2$ can be generated by $20^{th}$-order cascaded DFG processes when the optical intensity is $10MW/mm^2$, corresponding to a quantum conversion efficiency of 1033%. The high quantum conversion efficiency of 1033% exceeds the Manley-Rowe limit, which indicates that PPBT is an excellent crystal for THz wave generation via cascaded DFG.

Efficiency and Durability of Semi-Transparent Perovskite Solar Cells for BIPV (BIPV에 활용 가능한 반투명 페로브스카이트 태양전지의 효율 및 내구성에 관한 연구)

  • Kim, Su-kyung;Kim, Do-hyung;Soh, Joon-young;Choi, Dong-hyeok;Lee, You-sun;Kwak, Min-jun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.157-161
    • /
    • 2020
  • Regarding greenhouse gas reduction, BIPV (Building Integrated Photovoltaics) is an important technology that can generate its own power in urban buildings based on clean energy resources. In particular, the perovskite material is attracting attention as a BIPV solar cell because it can have various colors and transparency. However, it is not easy to increase both transparency and efficiency factors because solar cell transparency and efficiency are inversely related to each other. Therefore, in this paper, we propose a semi-transparent perovskite solar cell structure that can improve both transparency and efficiency, and evaluate the stability according to international standard.