• Title/Summary/Keyword: Electric Multiple Unit

Search Result 143, Processing Time 0.038 seconds

A Low Cost Multiple Current-Voltage Concurrent Control for Smart Lighting Applications (저가형 스마트 LED 조명 구동을 위한 다수의 전류-전압 동시 제어 방법)

  • kim, Tae-hoon;Lee, Sang-hoon;yang, Joon-hyun;Im, Chang-soon;Hyun, Dong-seok;Kim, Rae-young
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.179-180
    • /
    • 2011
  • This paper focuses on the Current-Voltage concurrent control method devoted to the multiple LED (light-emitting diode) string driver. Isolated DC to DC converter with cascaded chopping switch is proposed for smart lighting system such as light with sensor or back light unit of display, which need to control the current of parallel connected multiple LED stings and regulate DC voltage for micro controller for brightness control. The proposed circuit regulates the current of parallel connected multiple LED strings and additional DC voltage output simultaneously. To verify the performance, experimental results are presented based on the prototype board. 5V, 1A voltage mode electric load and two LED strings with different forward voltages are used for output loads. 23W output power is achieved and measured efficiency is in the range of 85%-87%

  • PDF

Development of Door Control Unit for the Electric Plug-in Door of Subway Train (전동차 전기식 플러그도어 출입문 제어 장치 개발)

  • Joung, Eui-Jin
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.47-53
    • /
    • 2011
  • The Electric Multiple Unit (EMU) has many types of door system such as sliding door, plug door etc.al. according to customer's requirements. The sliding door is widely used in Korea but has weak point in the noise problem. In the low operation speed, the noise coming from outer side of the EMU is not an important factor. As the speed is higher than before, noise is increased and make a problem. The main cause of noise is the imperfect air tightness in the EMU. The plug door system has advantages for the noise reduction characteristic in the high speed area. We have been developing electric plug-in door. The door is controlled by Door Control Unit(DCU) following the order of Automatic Train Protection (ATP) that is a kind of train signalling system. DCU has to simultaneously open and close the doors and the operation of it is related to the passengers safety. So DCU is a safety device that is important to reliability and safety. DCU is composed of several devices of control, motor driving, Input/Output, communication and power. In this paper, we will describe the functions, characteristic, requirement, subsystem and test results of DCU used for the electric plug-in door.

Analysis of Thermal Characteristics for Components of Electrical Door System in Electric Multiple Unit (전동차 전기식 도어시스템의 구성부품에 대한 발열 특성분석)

  • Lee, Bon Hyung;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.1
    • /
    • pp.18-24
    • /
    • 2020
  • This research conducted an the failure analysis was performed based on the failure and operation data for Seven years using the Reliability, Availability, Maintainability, and Safety(RAMS) constructed at the operation stage after the opening of the D urban railway. therefore, the risk priority was selected for failure frequency component within the door system that showed high failure. Finally, the goal was to suggest ways to improve the door system. For this purpose, the analysis of thermal characteristics of failed components such as Door Control Unit(DCU) in the door system based on the Seven-year failure analysis data of RAMS was performed. These results were applied to the main component exchange cycle of the door unit, the mean time between failure(MTBF) and mean kilometer between failure(MKBF) values of RAMS increased by 26% in 2017-2018 when the improvement measures were taken, and the MTBF value of DCU was 300,000 hours, which was a 57% improvement in reliability. The results of this thesis identify potential enhancements in reliability and improvements in maintenance of the door system that, if implemented, would contribute to train safety and reduce instances of failure in the future.

Unit Process Scheduling System Development and Calculation and Control Method of Planned Leadtime Using Multiple Linear Regression under Make to Order Manufacturing System in Transformer Winding Process (변압기 권선공정에서의 수주 제작품의 단위공정 일정관리 시스템 개발과 다중회귀분석을 이용한 계획 리드타임 산출 및 관리 방안)

  • Kang, Dae-Wan;Kang, Chang-Wook;Kang, Hae-Woon
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.31 no.3
    • /
    • pp.117-124
    • /
    • 2008
  • Ultra-high voltage transformer industry has characteristic of small quantity batch production system by other order processing unlike general mass production systems. In this industry, observance of time deadline is very important in market competitive power security and company continued existence. The transformer winding is a process that rolls a coil is coated with an electric insulation material in order to generate the required voltage using the voltage fluctuation. The winding process is very important production process in the extra-high voltage transformer manufacturing industry because winding process is core process that occupy weight about half of whole process and is process that decide current ratio of transformer. This paper proposes a statistical calculation and control method of planned leadtime on the basis of real data and informations for the A company in transformer winding process. Moreover, we develop unit process scheduling system.

Functional Analysis of Subsystem for Electric Plug Door (전기식 플러그 도어 하부시스템 기능 분석)

  • Joung, Eui-Jin;Hong, Jai-Sung;Won, Jong-Un;Lee, Jang-Mu;Lee, Han-Min;Kim, Gil-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2198-2199
    • /
    • 2011
  • The sliding door and plug door are the main types of door system in the EMU(Electric Multiple Unit). The sliding door is widely used in Korea but has weak point in the noise problem. In the low operation speed, the noise coming from outer side of the EMU is not an important factor. As the speed is higher than before, noise is increased and make an issue. The main cause of noise is the imperfect air tightness in the EMU. The plug door system has advantages for the noise reduction characteristic in the high speed area. Actually the noise level is an important factor for the passenger comfort. In this paper, we will describe the characteristic of electric plug door and functions of sub component.

  • PDF

Improved Design in Fishing Operation System for Small Inshore and Coastal Fishing Vessels -II -Design of a Remote Steering System- (소형 연근해 어선의 조업 시스템 개선에 관한 연구-II -원격 조타 시스템의 설계-)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.1
    • /
    • pp.25-32
    • /
    • 2000
  • A combination steering system was designed to provide the flexibility in controlling the steering wheel in fishing operations of the inshore and coastal fishing vessels. The designed steering system basically is consisted of three driving units, such as a electrically driven hydraulic pump unit with a solenoid control valve, a DC motor driven hydraulic pump unit and a manually driven hydraulic pump unit, and two controllers to provide remote steering on the deck, respectively. The steering torque was measured and analyzed to investigate the dynamic performance of the developed steering system. The steering system showed excellent linearity between the working pressure of cylinder and the torque of rudder post in case of increasing in rudder angle from $5^{\circ} to 35^{\circ}$ that is, the steering torque increased from $10.4 kgf{\cdot}m$ to $105.3 kgf{\cdot}m$ and then the working pressure of cylinder fluctuated from 6.3 kgf/cm super(2) to 16.4 kgf/cm super(2). The steering time of 3.2 sec in remote hydraulic steering by the on/off solenoid valve control was much faster than 13.2 sec in the manual steering by the helmsman and 11.6 sec in the electric steering by a DC motor, and then it was verified that operation of one unit does not affect other units in combination steering system in any way. Furthermore, the developed steering system can be remotely controlled in multiple stations of the deck during the fishing operation and the automatic pilot steering unit can be used to add hydraulic steering.

  • PDF

The Study on the Standardization of the Maximum Acceleration of the Electric Multiple Unit through the Analysis of the Traction and the Adhesion Characteristics (견인력 및 점착력 특성 분석을 통한 전동차 최대 가속도 규격 선정에 관한 연구)

  • Kim, Jungtai;Kim, Moo Sun;Ko, Kyeongjun;Jang, Dong Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7934-7940
    • /
    • 2015
  • The raise of the acceleration can be one of possible methods to increase the scheduled speed of the metropolitan railway system. It is possible to raise the acceleration to the some point by increasing the traction power of the motor. However, there is a limit of the acceleration because the traction power over some level related to the adhesion causes a slip, which prevents from accomplishing the target acceleration. The running resistance is also an important factor to consider. Both the adhesion and the running resistance as well as the traction power vary according to the velocity. Therefore, the standardization of the acceleration needs the analysis of these factors as a function of velocity. In this study, we focus on the advanced urban transit unit(AUTS) for the standardization. We derive a novel equation of the adhesion suitable for the AUTS by investigation of the traction and adhesion equation as well as the experiment data. And finally we propose the standard of the acceleration based on this analysis.

An Optimal Conjunctive Operation of Water Transmission Systems from Multiple Sources with applying EPAnet and KModSim Model (KModSim 모형(模型)에 의한 도시지역(都市地域) 다중수원(多衆水源) 송수관망간(送水管網間) 최적(最適) 연계(連繫) 운영(運營) 연구(硏究))

  • Ryu, Tae-Sang;Cheong, Tae-Sung;Ko, Ick-Hwan;Ha, Sung-Ryong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.500-504
    • /
    • 2008
  • The objective of this paper is to evaluate the feasibility of using an optimization model as a effective way to search conjunctive operation scheme to meet two conditions; one is to minimize the electric cost for pumping and another is to meet the water demand for satisfying customers. The feasibility is confirmed as comparing the best combinations of pumps between multi-regional water supply networks from multiple sources which are obtained through an optimization modeling and EPAnet modeling. KModsim model, a network optimization model, was used to determine conjunctive operation scheme in the pipe system. KModsim, based on Lagrangian Relaxation algorithm, is useful for modeling network system and obtaining simultaneously pump combination and water allocation with given input option such as energy unit cost supplying from a source into a consumer, operating pumping combination. This study develops the procedure of determining optimal conjunctive operation scheme with using KModsim model. As a study region, the water supplying systems of the Geojae-city in the Geongsang Namdo Province was selected and investigated. The EPAnet hydraulic simulation result(Ryu et al, 2007, KSWW) gave input data for optimization model; energy unit price(won/$m^3$), water service available area etc.. It was assured that the combination of pump operation through optimum conjunctive operation is to be optimum scheme to obtain the best economic water allocation with comparison to the hydraulic simulation result such as electric cost and pump combination cases. The results obtained through the study are as follows. First, It was found that a well-allocated water supply scheme, the best combination of pump operation through optimum joint operation, promises to save the electric cost and satisfy all operational goals such as stability and revenues during the period. Second, an application of KModSim, a network model, gave the amount of water allocation from each source to a consumer with consideration of economic supply. Finally, in a service area available to supply through conjunctive operation of existing inter-regional water supply networks within short distance, a conjunctive operation is useful for determining each transmission pipeline's service area and maximizing the effectiveness of optimizations in pumping operation time.

  • PDF

Design of Magneto-Rheological Clutch Coil Operation Unit using Electro Magnetic Field Analysis (전자기장 해석을 이용한 자기점성 유체 클러치 코일 작동부 설계)

  • Song, Jun-Han;Choi, Dook-Hwan;Chun, Chong-Keun;Kwon, Young-Chul;Lee, Tae-Haeng
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.3
    • /
    • pp.22-28
    • /
    • 2009
  • Recently, there has been an active study about smart fluid to control the vibration, in which MR fluid is evaluated as most efficient because it can generate different bonding forces based on the intensity of the external magnetic fields. This paper attempts to find a mechanism that, under limited conditions during a clutch production that uses such dynamic characteristic, defects the maximum intensity of electromagnetism. Using the finite element analysis program, we predicted a change within the bonding force of the MR fluid occurring inside the clutch when it is subjected to an increased electric current. In addition, we analyzed the change in the magnetic intensity when the coil comprising the coil control center is switched to multiple lines from the standard single line, to find a mechanism that can maximize the effect. Based on this analysis, we developed the clutch and tested its function, hoping to widen future MR fluid's range of application.

Real-Time Diagnosis of Incipient Multiple Faults with Application for Kori Nuclear Power Plant (초기 다중고장 실시간 진단기법 개발 및 고리원전 적용)

  • Chung, Hak-Yeong;Zeungnam Bien
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.670-686
    • /
    • 1995
  • This paper provides an improvement on our previous study [1] for multi-fault diagnosis in real time in large-scale systems. In the method, fault propagation probability(FPP) and fault propagation time(FPT) in a fuzzy sense are additively used to describe the fault propagation model(FPM) in more practical manner. A modified fault diagnosis procedure is also given. This method is applied for diagnosis of the primary system in the Kori nuclear power plant unit 2 under a transient condition in case of unit value of FPP on each branch of the FPM.

  • PDF