• 제목/요약/키워드: Electric Magnetic Interference

검색결과 55건 처리시간 0.025초

심질환 진단을 위한 심자도 파라메터의 추출 (Estimation of MCG parameters for the diagnosis of heart diseases)

  • 전창익;허영;김기욱;한병희;진승오;장원석;이현호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 신호처리소사이어티 추계학술대회 논문집
    • /
    • pp.549-552
    • /
    • 2003
  • The electrical current generated by heart creates not only electric potential but also a magnetic field. We have observed electrophysiological phenomena of the heart by measuring tangential components of magnetocardiogram(MCG) using 61 channel superconducting quantum interference device(SQUD) system. In this paper, we developed a new analysis method, which is based on the theory of electromagnetic field. We show some differences of the current direction between the normal MCG and the abnormal(ischemic heart disease) MCG.

  • PDF

형광등용 전자식 안정기의 EMI 대책 (Measurement of EMI on Fluorescent Electronic Ballast and Counter Analysis)

  • 강철;어익수;여인선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1959-1961
    • /
    • 2002
  • Requirements for high-efficiency equipment for energy saving are rapidly increasing recently keeping pace with development of digital and semiconductor technology. Accordingly, there are many changes and development in ballast. Ballast currently in use are Magnetic ballast (Coiled Type) and Electronic ballast. Electronic ballast produces incredible energy saving effect, but falls short of confidence instead. In addition, use at higher frequency through switching device creates Electromagnetic Interference (EMI) and high frequency. EMI creates low quality of equipment, damage in facilities and low productivity by leading miss operation of equipment, and interferes with surrounding machines. In this analysis I am going to examine characteristics of EMI on the Electronic ballast of FLR32SS one type pursuant to annex 3 of Electric Goods Technology Standard, and counter technology.

  • PDF

낙뢰정보 실신간 통계분석시스템 개발 (Development of Real Time Analysis System about Lightning Information)

  • 곽주식;우정욱;심응보;김기운;김용수;이성진;이건웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.169-171
    • /
    • 2003
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission tines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the development of real time analysis system about lightning information.

  • PDF

실시간 낙뢰화면 표시프로그램 개발 (Development of Heal Time Lightning Information System)

  • 곽주식;우정욱;심응보;김기운;김용수;이성진;이건웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.175-177
    • /
    • 2003
  • Because the overhead transmission lines arc exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the development of real time analysis system about lightning information.

  • PDF

LPATS에 의한 7년간의 한반도 뇌격특성분석 (Analysis of the lightning characteristics by LPATS Data during 7 year)

  • 우정욱;심응보;곽주식;권동진;문재덕;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.509-511
    • /
    • 2003
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the statistical distribution of lightning current parameters and the IKL map.

  • PDF

6.78MHz Capacitive Coupling Wireless Power Transfer System

  • Yi, Kang Hyun
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.987-993
    • /
    • 2015
  • Wireless power transfer technologies typically include inductive coupling, magnetic resonance, and capacitive coupling methods. Among these methods, capacitive coupling wireless power transfer (CCWPT) has been studied to overcome the drawbacks of other approaches. CCWPT has many advantages such as having a simple structure, low standing power loss, reduced electromagnetic interference (EMI) and the ability to transfer power through metal barriers. In this paper, the CCWPT system with 6.78MHz class D inverter is proposed and analyzed. The proposed system consists of a 6.78MHz class D inverter with a LC low pass filter, capacitor between a transmitter and a receiver, and impedance transformers. The system is verified with a prototype for charging mobile devices.

심자도 데이터의 신경망 분석 (An Analysis of Magnetocardiogram Data using Neural Network)

  • 엄상희
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.281-282
    • /
    • 2016
  • 심장에 의해 발생된 전류는 단지 전위뿐만 아니라 자기장을 생성한다. 이 논문은 양자 간섭 장치(SQUID) 시스템의 초전도 61 채널의 심자도(MCG) 시스템의 파라미터를 이용하여 신경회로망 알고리즘으로 심장 질환의 진단을 위한 분석을 수행하였고, 질환 진단에 사용 가능한 결과를 얻었다.

  • PDF

CTL cell에서의 우세장 발생과 특성 (The generation and characteristics of the dominant field in CTL cell)

  • 박웅희
    • 한국정보통신학회논문지
    • /
    • 제17권5호
    • /
    • pp.1055-1063
    • /
    • 2013
  • 전자파 내성 및 전자파 장해 측정을 위한 표준 전자파 발생 장치 중 하나인 CTL cell에서 두 개의 입력 단자에 동일 신호와 역위상 신호 입력에 따른 다양한 전계와 자계 발생에 대해 살펴보았다. 기본 공진주파수 TE011이 2.20GHz인 CTL cell을 이용하여 우세 전계장과 우세 자계장 조건에서 입력 전력의 변화에 따른 전계 특성, 측정 위치에 따른 전계 특성, 주파수 변화에 따른 전계 특성을 측정하였고, 이를 이용하여 CTL cell의 측정 영역에서의 동작 특성과 공진주파수의 영향을 받지 않고 사용 가능한 주파수 대역을 살펴보았다.

SQUID를 이용한 심자도 기술의 개발동향 (Review of Magnetocardiography Technology based on SQUIDs)

  • 이용호;권혁찬;김진목;김기웅;유권규;박용기
    • Progress in Superconductivity
    • /
    • 제13권3호
    • /
    • pp.139-145
    • /
    • 2012
  • Electric activity of cardiac muscles generates magnetic fields. Magnetocardiography (or MCG) technology, measuring these magnetic signals, can provide useful information for the diagnosis of heart diseases. It is already about 40 years ago that the first measurement of MCG signals was done by D. Cohen using SQUID (superconducting quantum interference device) sensor inside a magnetically shielded room. In the early period of MCG history, bulky point-contact RF-SQUID was used as the magnetic sensor. Thanks to the development of Nb-based Josephson junction technology in mid 1980s and new design of tightly-coupled DC-SQUID, low-noise SQUID sensors could be developed in late 1980s. In around 1990, several groups developed multi-channel MCG systems and started clinical study. However, it is quite recent years that the true usefulness of MCG was verified in clinical practice, for example, in the diagnosis of coronary artery disease. For the practical MCG system, technical elements of MCG system should be optimized in terms of performance, fabrication cost and operation cost. In this review, development history, technical issue, and future development direction of MCG technology are described.

EEG, fMRI, EAV 및 SQUID장치(裝置)를 이용(利用)한 기공현상(氣功現狀) 측정(測定) (The Studies on Qigong state Using EEG, fMRI, EAV and SQUID Measurments)

  • 정찬원;최찬헌;윤유식;소철호;나창수;장경선
    • Korean Journal of Acupuncture
    • /
    • 제21권2호
    • /
    • pp.1-28
    • /
    • 2004
  • Objectives : Human physiological changes in the state of qigong has been measured using EEG(Electroencephalography), functional MRI(functional Magnetic Resonance Image), EAV(Electro-Acupuncture according to Voll) and SQUID(Superconducting Quantum Interference Device) measurements. Methods & Results : EEGs were measured to study the differences between Qigong masters and Qi receiver on the changes of EEG. During Qigong, an alpha waves were increased. The power spectra indicate that the peak frequency of alpha waves increased during Qigong. Qi receiver's EEG signals seemed to affected by the state of himself. Brain activation did not observed when qigong master concentrates the Qi at Laogong(P8). But a localization of fMRI signal in the sensory cortex was observed by electric acupuncture stimulation at Laogong(P8). Five phase deviation of EAV were clearly changed in the both cases of Qigong master and Qi receiver. When a Qigong master concentrates the Qi at Yintang, Laogong(P8), Qihai(CV6) meridian points during Qigong state, the change of magnetic field around acupoints Yintang, Laogong points has been measured using 40-Channel DROS-SQUID apparatus. After smoothing process of the continuously measured magnetic signal around acupoints for a few minutes, we could observe that a series of peaks, magnitude of -1.0~2.5pT appeared. But there was no significant difference in changes of magnetic signal around acupoints. Physical signals of magnetocardiogram has been measured by using 2-Channel DROS SQUID(Magnetocardiogram). Physical signals of magnetocardiogram were clealy changed at the ST segments after S-wave when qigong master concentrates the Qi.

  • PDF