• 제목/요약/키워드: Electric IT Equipment

검색결과 614건 처리시간 0.033초

ETA를 통한 연구실험실 콘센트회로의 전기재해 분석 (Analysis of Electrical Accident for Outlet Circuit of Laboratory on ETA)

  • 김두현;김성철;박종영;김상철
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.27-33
    • /
    • 2017
  • This study is intended to identify issues on the basis of investigating the actual state of laboratory environment and outlet circuit, and derive end states by expressing sequences from the initiating event of disaster to accident in leakage current, poor contact and overload through ETA(event tree analysis). To this end, this study investigated the actual state of electric equipment of laboratory at universities in all parts of country. And it is shown that most of them are failure in electric work and user negligence in the investigation of actual state. It is found that there is earth fault and defect in wire diameter in the failure of electric work and the problem of partial disconnection due to wire bundling and poor contact in user negligence. Outlet-related component, failure rate and initiating events are composed of a total of 41 initiating events, i.e., 30 internal initiating events and 11 external initiating events. And end states are composed of a total of 15 parts, i.e., 3 electric power parts and 12 safety parts. Earthing class 3 is the most important safety device against leakage current (initiating event). And in case of poor contact, it is necessary for manager to check thoroughly because there is no safety device. In case of overload/overcurrent, when high-capacity equipment is connected, a molded case circuit breaker, safety device, worked. However, in most cases, it is verified that this doesn't work. This study can be utilized as electric equipment safety guide for laboratory safety manager and managers.

압전 센서 제작 및 결함에 따른 PD 분포 분석 (Analysis of PD signals according to defects of the piezoelectric sensor)

  • 정해은;박성희;강성화;임기조;이강원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1480-1481
    • /
    • 2006
  • It is very difficult and dangerous to measure partial discharge from high voltage equipment in outdoor situation. But that is very important thing for preventing serious accidents from defects which originated in insulating degradation. This paper provides useful method to detect PD signals easily without any dangerous situation. Electric field sensor by the principle of capacitor detect PD signals without direct electrical connection between sensor and high power equipment and has very wide frequency range suitable for noise rejection. Electric field sensor and related circuit for processing PD signal showed good performance as a PD sensor when it is applied to simulated high power equipment generating PD pulse.

  • PDF

전류 모니터를 이용한 백열등 부하 전기설비에서 사고 징후 검출에 관한 연구 (A Study on the Detection of Indication of Accident in Electric Equipments with Incandescent Lamps Using Current Monitor)

  • 지승욱;옥경재;김시국;이춘하;이광식
    • 조명전기설비학회논문지
    • /
    • 제23권1호
    • /
    • pp.109-115
    • /
    • 2009
  • 본 논문은 백열등 부하 전기설비에서 측정한 전류 파형으로 전기사고 징후를 조기에 검출하기 위한 것이다. 첫째, 저항성 회로에서 전류 모니터의 특성을 분석하였다. 둘째, 백열등을 부하로 하는 전기설비를 구축하고, 전기설비의 일부에서 KS C IEC(Korea Standard C International Electrostatic Commission) 60112에 따라 트래킹을 발생시켜 사고를 모의하였다. 전기사고 징후는 전류 모니터로 측정한 전류파형을 분석함으로써 검출되었다. 그 결과 부하의 수에 관계없이 사고의 최종 단계인 트래킹으로 진전되어 갈수록 전류 파형에는 점점 큰 전류 펄스가 보였고 출현빈도도 더욱 높아졌다.

지하철 역사의 안정적 전원공급을 위한 보호시스템 검토 (A study on present status and improvement of protection relay system in subway station for stable power supply)

  • 나종우;조원강;박동선;유연성;문화수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.433-444
    • /
    • 2008
  • Nowadays, subway station has provided not only transportation but living spaces for everyday activities. Therefore, a variety of facilities have been installed for a safety of citizens such as fire-fighting equipment, platform screen doors and giving high level of benefits such as air-conditioning and heating equipment, escalators, lighting apparatus. In order to operate these facilities appropriately, it is needless to say that electric power supply must be reliable. Many protection relays have been installed to protect electric apparatus and power system, nevertheless it..s study has been insufficient in the concrete. From this paper, through analyzing of protection relay system of electric room operated in line 2 of Seoul metro, we can help to improve stable power supply system of subway station.

  • PDF

도시철도 지하구간 접지설비 표준화 기준 연구 (A Study on the Unification of the Grounding System of Urban Railroad)

  • 김균식;박한용;백유호;심재창
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.470-480
    • /
    • 2008
  • After 1th line was built in 1974, the history of subway in Korea has been expended to 9th line which is under construction. It is time to prepare nation wide subway grounding system urgently according to the domestic electric standard that aligns to world wide standard by WTO/TBT treat (1995). Newly added grounding system to the fundamentally different system caused many problems. PSD(platform screen door) and other newly added equipment are also need grounding system. By the electrical code(established by Korea Electric Association), low voltage equipment(including grounding system) under 1,000V AC are in the process of change into IEC 60374. IEC 60364 standard will be added to the electrical code(established by Korea Electric Association) in 2007 and amended and after 3-5 years later, it will become a complete IEC 60364. So the purpose of this study is to compare the domestic rail road grounding system and suggest the standardized grounding system for the newly built subway.

  • PDF

LCD를 이용한 통전상태 표시기 개발 (Voltage Application Indicator Using Liquid Crystal Device)

  • 구경완;류승헌;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1757-1759
    • /
    • 2000
  • To make a inspection and maintenance of the high voltage equipment, electric machinery to transmit and distribute the electric power, the appearance of a simple and inexpensive indicator with which the charge condition of bare conductor parts could be read at a Stance has been needed. Liquid crystal has recently been expanding its application rapidly in appliances for everyday use. Since its display energy is extremely small, it is possible to obtain the working current with simple condenser voltage divider that makes use of stray capacity when it is applied to electric power equipment. Thus, an apparatus has finally appeared which is close to the one they have sought and indicates the existence of voltage impressions.

  • PDF

전기밥솥 FCT 검사 자동화 System의 검사 신뢰성 평가에 관한 연구 (A Study on Inspection Reliability Evaluation of Electric Rice Cooker FCT Inspection Automation System)

  • 정해진;이종찬
    • 한국기계가공학회지
    • /
    • 제21권6호
    • /
    • pp.30-35
    • /
    • 2022
  • This study has focused on the reliability evaluation of FCT inspection automation equipment for electric rice. To evaluate the reliability of FCT inspection automation equipment, voice analysis, Gray/R/G/B channel experiment, FND segment experiment, and robot position repeatability were performed. In the voice analysis experiment, the comparison value between the recorded and digital output waves was over 99%, indicating a very high result. It was confirmed that both the gray/R/G/B experiment using vision and the FND segment could confirm the output value of the product through vision. The position repeatability of the robot is also excellent, so it is concluded that the inspection effect through the FCT automation system will be excellent.

Development of Viscous Inspection Equipment by Moire Phenomenon for Flatron Panel Glass

  • Chung, Kyu-Chul
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.118-121
    • /
    • 2002
  • In this study, we describe the development of viscous inspection equipment for flatron panel glass by Moire phenomenon and propose a new idea to develop an automatic inspection system for viscous or cord defects. It is possible to detect string viscous more easily and the equipment is practically being applied in production line. After using this equipment, the ratio of defective from customer is dropped significantly.

  • PDF

전기자동차용 2차전지를 위한 스마트 ICT형 전자식 외부 단락시험기 개발 (Development of Smart ICT-Type Electronic External Short Circuit Tester for Secondary Batteries for Electric Vehicles)

  • 정태욱;신병철
    • 한국산업융합학회 논문집
    • /
    • 제25권3호
    • /
    • pp.333-340
    • /
    • 2022
  • Recently, the use of large-capacity secondary batteries for electric vehicles is rapidly increasing, and accordingly, the demand for technologies and equipment for battery reliability evaluation is increasing significantly. The existing short circuit test equipment for evaluating the stability of the existing secondary battery consists of relays, MCs, and switches, so when a large current is energized during a short circuit, contact fusion failures occur frequently, resulting in high equipment maintenance and repair costs. There was a disadvantage that repeated testing was impossible. In this paper, we developed an electronic short circuit test device that realizes stable switching operation when a large-capacity power semiconductor switch is energized with a large current, and applied smart ICT technology to this electronic short circuit stability test system to achieve high speed and high precision through communication with the master. It is expected that the inspection history management system based on data measurement, database format and user interface will be utilized as essential inspection process equipment.

Development of the Corrosion Deterioration Inspection Tool for Transmission Tower Members

  • Woo, Sangkyun;Chu, Inyeop;Youn, Byongdon;Kim, Kijung
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권2호
    • /
    • pp.293-298
    • /
    • 2016
  • Recently, interests for maintenance of transmission tower are increasing to extend life of structures and reduce maintenance cost. However, existing classical diagnosis method of corrosion deteriorated degree on the transmission tower steel members, visual inspection, has a problem that error often due to difference of inspector's individual knowledge and experience. In order to solve the problem, this study carried out to develop the corrosion deterioration inspection tool for transmission tower steel members. This tool is composed of camera equipment and computer-aided diagnosis system. We standardized the photographing method by camera equipment to obtain suitable pictures for image processing. Diagnosis system was designed to evaluate automatically degree of corrosion deterioration for member of transmission tower on the basis of the RGB color image processing techniques. It is anticipated that developed the corrosion deterioration inspection tool will be very helpful in decision of optimal maintenance time for transmission tower corrosion.