• Title/Summary/Keyword: Electric IT Equipment

Search Result 614, Processing Time 0.026 seconds

A Performance Test Equipment for Rechargeable Electric Tools

  • Lee, Jong-Kwang;Lim, Hyo-Jae;Park, Min-Kyu;Koh, Jin-Ha;Lee, Kyu-Won;Kang, E-Sock
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.68.5-68
    • /
    • 2002
  • For the performance test of rechargeable electric tools, it is necessary to test under the same condition as the actual operation condition. They are necessary to control the load torque and to acquire the test data with a computer, and it should be convenient to fix the tool on the test equipment for rechargeable electric tools. It consists of torque loading parts, sensing parts and control software. Two hysteresis brakes, connected serially with flexible coupling, were applied to control the load for the test. The sensing part consists of a torque sensor, a rpm detector and a power analyzer. The torque and the rpm were measured in order to calculate the output of the rechargeable electric...

  • PDF

Development of Noise Source Detection System using Array Microphone in Power Plant Equipment (배열형 음향센서를 이용한 발전설비 소음원 탐지시스템 개발)

  • Sohn, Seok-Man;Kim, Dong-Hwan;Lee, Wook-Ryun;Koo, Jae-Raeyang;Hong, Jin-Pyo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.99-104
    • /
    • 2015
  • In this study, it has been initiated to investigate the specific abnormal vibration signal that has been captured in the power equipment. Array Microphone can be used in order to detect the direction and the position of the noise source. It is possible to track the abnormal mechanical noise in the power plant by utilizing the program and the microphone array system developed from this research. Array microphone system can be operated as a constant monitoring system.

A Study of Evaluation Certification on Electronic Power u-IT Convergence Equipment (전력 u-IT 융복합화 기기의 평가와 인증 연구)

  • Yi, Jeong-Hoon;Park, Dea-Woo;Bae, Suk-Myong;Kim, Eung-Sik;Kim, Hong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.499-502
    • /
    • 2009
  • Supply of electric power and electricity safety for whole system and network are essential element. Electricity safety technology need rating for product and research about certification as product development that is done cotton flannel mixed with development of u-IT technology consists. Study on serve to develop electricity safety integration supervision system to apply product to u-City electric power appliance and cotton flannel mixed of u-IT appliance, Connection badness sensing instrument made device built-in electric power IT cotton flannel mixed in outlet that is used most in electric power appliance terminal. Using sensor on ZigBee, RFID performance estimation of communication and module for remote safety check of electricity safety integration supervision system. A performance experiment and estimation in PD, Arc detection diagnosis system and certification KS, electricity safety about product that get fitness finding.

  • PDF

A study on optimizing the electrical load analysis for modifying the avionics equipment in an aged aircraft

  • Yoon, Inbok;An, Kyeongsoo
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.4
    • /
    • pp.47-56
    • /
    • 2021
  • In the management of aged aircraft, used avionics equipment is replaced with new ones to improve the performance and extend the life cycle of the aircraft. In this case, considering airworthiness, it is necessary to check whether the aircraft has sufficient electricity in the electric generator or the electrical distribution system, in accordance with the maximum electricity consumption of the new avionics equipment. Accordingly, this paper reviews a few airworthiness standards and guidelines associated with the electrical load analysis when an avionics equipment is upgraded in an aged aircraft, and proposes an optimization method for the electrical load analysis. In addition, it verifies the validity of the proposed method via the QFD theory, and is currently available for upgrading the performance of aged aircraft.

An Analysis of Various Factors that Determines the Size of Electric Room(22.9Kv class) (전기실의 면적을 결정하는 제 요소의 분석(22.9Kv class))

  • Eo, Ik-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.443-445
    • /
    • 2001
  • As the new large buildings are continuously being built with the advanced technology and skills, an adequate size of electric room needs to be obtained so that engineers establish an efficient and reliable system in the electric room. Considering the current capacity, its expansion and its connecting system, the final size of it should be determined in order to bring an effective use of the building. Usually the extension of electricity capacity is on the increase after construction and it comes from the lack of scientific evaluation on the electric room. Later when the expansion of computer and important electric equipment that needs much capacity is impossible, it will cause a great deal of damage to the renting business of the building as well as becomes the unstable factors of the whole system. Therefore, it is important to have the exact method of calculating the effective size of electric room, the heart of the building, especially when the value of land price is very high. In addition, it should be calculated in an accurate way due to the diversification of the system and the compact size of the electricity equipment. However, the research on this area and the comparison and evaluation of the size after construction have not been made enough and the results of them have not been applied when calculating a new size of electric room. Accordingly, this study examines three methods prescribed in the standards of electricity installation technology through case analysis and suggests substantial data by system, capacity, and purpose.

  • PDF

The THD measurement of HEP equipment power installed on 8200 series Electric locomotive (8200대 신형 전기기관차 HEP 장치 고조파 왜율 측정)

  • Kim, Dae-Sung;Lee, Kyung-Rac;Ahn, Hong-Goan;Park, Jong-Chun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.488-497
    • /
    • 2010
  • 8100 series Electric locomotive was imported from SIEMENS of Germany on 2001. 8100 series model is modified from BR152 model to be complied with national environment. After 8100 series Electric locomotive carried out main line test for long time, 8200 series Electric locomotive produced in 10 locomotives with improvement and supplement on some parts. the one of supplement is to install the HEP equipment. In paper, about total harmonic distortion of HEP equipment power, it compares the result of combination with the result of actual measurement. It checks whether the measurement meets the specification of design or not. And it describes international standard about total harmonic distortion of supply system.

  • PDF

A Study on Communication Controller of Electric Vehicle Supply Equipment for Information Exchange between Electric Vehicle and Power Grid (전기차와 전력계통의 정보교환을 위한 전기차 충전장치의 통신 제어기에 대한 연구)

  • Han, Ah;Shin, Minho;Kim, Intaek;Jang, Hyuk-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.11
    • /
    • pp.1564-1570
    • /
    • 2014
  • An electric vehicle (EV) not only receives electric power from the electric vehicle supply equipment (EVSE), but it also exchanges the information regarding charging process with the power gird through the EVSE. However, the EV and EVSE communicate using the ISO/IEC 15118 standard while the EVSE and power grid communicate using the IEC 61850 standard. Therefore, the EVSE should support both the ISO/IEC 15118 and IEC 61850 standards, and provide a data mapping function between the two communication protocols so that the EV and power grid, which support different protocols, can communicate with each other throughout the charging process. In this paper, we propose a mapping method of the EVSE, which converts the ISO/IEC 15118 data to IEC 61850 and vice versa, based on the XML schema of each protocol. The proposed method converts the data using the XSL (eXtensible Stylesheet Language) method, which defines the data mapping between two XML schemas. Our approach is more flexible and easier to maintain against changes in charging scenarios and the standards than other existing approaches such as one-to-one data mapping methods.

Reliability-Centered Maintenance Model for Maintenance of Electric Power Distribution System Equipment (배전계통 기기 유지보수를 위한 RCM 모델)

  • Moon, Jong-Fil;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.410-415
    • /
    • 2009
  • With the implementation of electric power industry reform, the utilities are looking for effective ways to improve the economic efficiency. One area in particular, the equipment maintenance, is being scrutinized for reducing costs while keeping a reasonable level of the reliability in the overall system. Here the conventional RCM requires the tradeoff between the upfront maintenance costs and the potential costs of losing loads. In this paper we describe the issues related to applying so-called the "Reliability-centered Maintenance" (RCM) method in managing electric power distribution equipment. The RCM method is especially useful as it explicitly incorporates the cost-tradeoff of interest, i.e. the upfront maintenance costs and the potential interruption costs, in determining which equipment to be maintained and how often. In comparison, the "Time-based Maintenance" (TBM) method, the traditional method widely used, only takes the lifetime of equipment into consideration. In this paper, the modified Markov model for maintenance is developed. First, the existing Markov model for maintenance is explained and analyzed about transformer and circuit breaker, so on. Second, developed model is introduced and described. This model has two different points compared with existing model: TVFR and nonlinear customer interruption cost (CIC). That is, normal stage at the middle of bathtub curve has not CFR but the gradual increasing failure rate and the unit cost of CIC is increasing as the interruption time is increasing. The results of case studies represent the optimal maintenance interval to maintain the equipment with minimum costs. A numerical example is presented for illustration purposes.

Methods to Reduce Greenhouse Gas for University Buildings to Make a Low-Carbon Green Campus - With Case Study on the 'E' University -

  • Song, Su Min;Peom, Sung Woo;Park, Hyo Soon;Song, Kyoo Dong
    • KIEAE Journal
    • /
    • v.14 no.2
    • /
    • pp.37-46
    • /
    • 2014
  • University buildings are energy-guzzling facility that consume more than 10,000TOE within a campus annually. Even the consumption is on an upswing trend. Behind such high consumption are there cheap power rates for education facility, lack of high-efficiency equipment and ever-increasing use of various information equipment. Being keenly aware that greenhouse gas emission increases due to such rise of energy consumption, the present study carried out a case study. In the case study, the study chose the buildings of E university from top 10 universities that consume energy most in Seoul and examined the current status of their energy consumption and greenhouse gas emission. And then it set the reduction target of greenhouse gas by year. Putting aside a middle and long-termed strategy for later endeavor, it first established the 1st year's implementation plan (2014) for energy saving and greenhouse gas reduction with limited budget and according to greenhouse gas reduction target. The plan is specified as follows. Targets for energy saving are mainly divided into two sectors: machine equipment and electric equipment. 7 ideas were proposed. Three ideas to improve machine equipment are to replace with high-efficiency boilers and chillers and to adjust the position of the cooling tower. By doing so, it was estimated that energy could be saved by 176.34TOE in total and greenhouse gas could be reduced by 370.771t$CO_2$-eq. Four ideas to improve electric equipment include the replacement with LED lights, LED emergency lights and high-efficiency motors and the installation of motion sensors. It was calculated that such replacement could conserve 1,076.08TOE (electric energy) and reduce 2,181.420t$CO_2$-eq (greenhouse gas).

An Electrical Installation Failure Signal Detection using Time-Energy Analysis (시간-에너지 분석을 이용한 전기설비 이상신호 검출)

  • Jee S. W.;Lee C. H.;Kim Ch. N.;Lee K. S.;Sim K. Y.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.2
    • /
    • pp.82-87
    • /
    • 2006
  • Most of electric accidents are happened in the place where activities are frequent by common people who has low electric knowledge. Also, accidents are increased in the low voltage electric equipment. So, it is increased to spread the dispersion or non-utility power generation system. It means that ordinary times observation is required for electric equipments by common people. This paper is studied for the diagnosis method of electric equipment that common people can diagnose easily Voltage is generally and exactly measured in the electric and electronic field. We suggest new analysis tools using only electric voltage. It is called the Time-Energy analysis. The Time-Energy analysis is as following First, divide measured voltage waves into same parts, Second, conducted FFT(Fast Fourier Transform) transform for each divided period, Finally, each results are reassembled after graphic treatment. We compared Time-Energy analysis with discharge form by tracking tester. As the result, tracking discharge processes distinguished clearly.