• Title/Summary/Keyword: Electric Heater

Search Result 258, Processing Time 0.029 seconds

A Study on the Temperature and Electrical Characteristics of Carbon Heater (카본 발열체의 온도 및 전기적 특성에 관한 연구)

  • Jin, Z.H.;Shim, K.J.;Kong, T.W.;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.10 no.1
    • /
    • pp.71-76
    • /
    • 2006
  • This paper aims to study several type heaters which are mica heater, film heater, quartz heater and rod heater and to get an temteraturel and electrical characteristics. These four type heaters have a merit in many fields than present electric heater with nichrome wire. Carbon and mica plate heater have higher heat efficiency and less electromagnetic waves. Also it has been reported that far infrared ray emission from this heater is good for our health. Additionally heating element is thin and lighter plate. For these reasons, they will be widely used to various application such as room-heating or manufacturing goods. Experimental result confirmed that when 220V current authorized, the temperature, electric current, electric power and the resistance rise to stationary state in early stage. Moreover, the temperatures and electric characteristics show a good stability.

  • PDF

An Experimental Study on the Fire Hazards in Electric Heater (전기히터의 화재위험성에 관한 실험연구)

  • Hong, Sung-Ho;Lee, Bock-Young;Park, Sang-Tae;Yu, Hyun-Jong
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.2 s.80
    • /
    • pp.36-40
    • /
    • 2007
  • This study presents on the analysis fire hazards of electric heater. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate normal condition and abnormal condition. The abnormal condition experiment is simulated in which combustibles are placed near by electric heater. Vertical burning test(UL 94) is conducted for the fire retardant experiment. The results show that fire hazard is high in case of abnormal condition. And Material of electric heater has not fire retardant performance. In this paper, we suggest to add temperature fuse in electric heater for reducing fire hazard.

Analysis on Cascade Cycle Heat Pump Application as Night Storage Heater (심야전력을 이용한 Cascade Heat Pump Cycle의 운전결과 분석)

  • JUNG, H.;HWANG, S.W.;LEE, C.H.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.1
    • /
    • pp.113-118
    • /
    • 2011
  • To analyze and verify the effect of replacing thermal storage heater by a cascade cycle heat pump using midnight electricity was installed and tested at a customer's house in Wonju, Korea. The electric night storage heater is consist of 30kW electric heater and 2,700 liters of thermal storage water tank to supply hot water for warming house floor. The power for electric heater was cut off and hot water was only generated by cascade cycle heat pump. Current thermal storage water tank was not eliminated and electric heater wiring was modified. Some operation logic of the heat pump was also modified for proper operation. The required capacity of the heat pump and hot water temperature for given warming condition were estimated. The estimated capacity of heat pump was about 19kW and estimated hot water temperature for proper heating was at least $75^{\circ}C$.

Development of Measurement and Performance Testing System for Heat Pump water Heater (히트펌프 온수기 개발을 위한 계측 및 성능평가시스템 구축)

  • Kwon, Seong-Chul;Yang, Seung-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2310-2312
    • /
    • 2004
  • In Korea Electric Power Corporation (or KEPCO), several Demand-Side Management (or DSM) program have been carried out to effectively meet electric power demand at least costs by modifying customers electricity use patterns. As one of them, KEPCO applies low-priced night thermal-storage power service for heat appliances to facilitate efficient use of power facilities by shifting relatively high daytime demands to night hours to build loads during the off-peak periods. In the market of heat-storage type water-heater, electric water-heater has been mostly used, but it has low energy efficiency and needs high capacity electric equipments. So in order to replace these electric water heaters, 15 HP air-source heat pump water heater is developed in Korea Electric Research Institute (or KEPRI). This paper shows that measurement system for performance testing of heat pump water heater is established and heating capacity and performance is analyzed and measured for out-door environmental change.

  • PDF

Energy Performance Comparison of Electric Heater and Geothermal Source Heat Pump type Agricultural Hot Air Dryers (전기히터식 및 지열원 히트펌프식 농산물 열풍건조기의 에너지 성능 비교)

  • Yang, Won Suk;Kim, Young Il;Park, Seung Tae
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.4
    • /
    • pp.7-12
    • /
    • 2018
  • Energy performance of electric heater and geothermal source heat pump type hot air dryers are compared in this study. For set temperatures of $30^{\circ}C$, $35^{\circ}C$ and $40^{\circ}C$, radish is dried from initial mass 60 kg until it gets 5 kg, where the difference equals the amount of water removed. As set temperature is increased, drying time is shortened for both electric heater and heat pump types, however energy efficiency is decreased due to increasing electricity consumption. Moisture extraction rate(MER) of electric heater is 2.58~2.84 kg/h, and for heat pump type 2.56~2.71 kg/h, showing little difference between the two types. Specific moisture extraction rate (SMER) of electric heater is 0.94~0.96 kg/kWh, and for heat pump type 1.72~2.21 kg/kWh. SMER of heat pump type is greater by 0.78~1.25 kg/kWh than the electric heater hot air dryer, which is 1.8~2.3 times better in terms of energy efficiency.

An Experimental Study on the Fire Risk of Electric Heaters According to Contact of Flammable Materials (가연물 접촉에 따른 전기히터의 화재위험성에 관한 실험적 연구)

  • Lee, Sung-Ryong
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.63-71
    • /
    • 2011
  • In this study, it was evaluated the fire risk of an electric heater as representative seasonal appliances. Two type of electric heaters were used in experiments. When electric heaters were operated, temperature variation was measured around the heater. Internal structure was understood by Nondestructive inspection. It was evaluated the tire risk of electric heaters, when flammable materials were positioned ear a heater. It was also estimated the probability of a tire in case of malfunction of a safety tip-over witch. When a heater was operated in a normal condition, temperature was maintained under $80^{\circ}C$ around the heater. The possibility of a fire is very high, when a heater is covered with flammable materials or malfunction of safety parts (safety tip-over switch, anti-overheating devices).

Performance Evaluation of the Hybrid Defrost Process in the Fin-Tube Evaporators of Refrigerators (하이브리드 제상 방식을 적용한 냉장고용 핀-관 열교환기의 제상 성능 평가)

  • Lee, Su-Won;Park, Yong-Joo;Kweon, Lae-Un;Jeong, Young-Man;Lee, Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.38-46
    • /
    • 2011
  • The hybrid defrost process combined with hot-gas bypass defrost and electric heater defrost was experimentally evaluated about its defrost performance in the fin-tube evaporators of household refrigerators. Also the hybrid defrost process was compared with only electric heater defrost process. The defrost efficiency of the hybrid defrost process was shown two times higher than electric heater defrost process. The defrost time of the hybrid defrost process was shorten about 10%~50% than electric heater defrost process. Thermal shock after defrost process was decreased about 50% for the case of the hybrid defrost. It was found that energy consumption ratio of defrost process was reduced up to 7.4% compared with 22.4% of electric heater defrost at the condition of $25^{\circ}C$ ambient temperature.

Development of Energy Saving Electric Fan Heater (에너지 절약형 전기 온풍기 개발)

  • Kim, Jin-Bong;Koo, Dae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.97-99
    • /
    • 1994
  • Energy saving electric fan heater that uses driving part as heating part is different from general fan heater. As it uses energy that drives rotor and generate heat at the same coil. it is simpler and cheaper than fan heater. In this study, shaded-pole motor that is low cost and simple in spite of low efficiency was used for th fan heater.

  • PDF

Safety Schematic Diagram and Sequence of Heater in FPD Wet Equipment (FPD 장비 습식공정에서의 안전한 히터 공급 계통도 및 제어 회로)

  • Yoo, Heung-Ryol;Son, Yung-Deug
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.107-111
    • /
    • 2019
  • In FPD WET equipment, heaters are used a lot. There are many electric accidents caused by short circuit and overheating due to the use of heater, so it is necessary to have a safe electric system and interlock. Therefore, in this paper, we propose an electrical schematic and interlock for FPD WET equipment. In this paper, a hardware interlock such as a level sensor, an overheat protector, and an SSR heater sink is inserted, and the electric system is composed of ELB - MC - SSR - EOCR - heater. When the interlock occurs, the magnetic contactor (MC) is turned off and the power of the heater is cut off.EOCR, an electric overcurrent protection device, has an interlock to shut down the MC when there is an abnormality in the heater while checking the overcurrent, undercurrent and disconnection. These circuit configurations and interlocks are likely to be useful not only for WET equipment but also for any equipment in which the heater is placed.

Fault Diagnosis Device for Fire Prevention of the Resistance Heating Type three-Phase Electric Heater (3상 저항가열식 전기히터의 화재예방을 위한 결함 진단장치)

  • Lee, Mun-Hyung;Kim, Chan-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.11
    • /
    • pp.1669-1674
    • /
    • 2017
  • In this study, We have discussed the development of a diagnostic device to detect and prevent electrical fire due to the arc caused by contact failure and partial disconnection at the connection part of the three-phase electric heater wiring used in the industrial field. The arc caused by contact failure and partial disconnection at the connection part of the electric heater shows a change in the current effective value. Therefore, it is possible to determine whether there exists a defect by analyzing the current unbalance factor and the number of current fluctuations with the diagnostic apparatus. The three-phase unbalanced heater is considered to be capable of determining defects through periodic measurement and trend analysis of the current unbalance factor. It is also expected that this device can be used not only for electric heaters but also for detection of defects in wiring and connections of electrical equipment having a characteristic of constant load current.