• Title/Summary/Keyword: Electric Fires Prevention Measures

Search Result 11, Processing Time 0.029 seconds

A Study on the Establishment of Preventive Measures for Electric Fires Using the 4M Technique (4M 기법을 활용한 전기화재 예방대책 수립 연구)

  • Oh, Teakhum;Park, Chanseok
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.4
    • /
    • pp.23-29
    • /
    • 2021
  • The purpose of this study is to reduce the probability of occurrence of electric fires as a preemptive preventive measure, and to strengthen the capability of preventing electric fires by strengthening the cooperative function between electric fire-related departments and establishing a cooperative system. In this study, the general aspects of electric fires were identified by reviewing the literature such as ignition mechanisms of electric fires. And the major electrical fires that occurred in the last 10 years were classified into ignition factors (short circuit, overload/overcurrent, and earth leakage/ground fault) and ignition sources (wiring/wiring appliances, electrical equipment/household appliances). And the 4M technique was used to analyze the potential causes of ignition at the fire site and to suggest preventive measures. In the case In this study, out of 48 electrical fires in the past 10 years, 16 short-circuit fires, 3 overload/overcurrent fires, 3 short-circuit and earth fault fires, 16 fires in wiring/wiring appliances, and 10 fires in electrical equipment/home appliances classified as cases. And prevention measures were presented in terms of human, machine, media, and management by using the 4M technique. For the preemptive prevention of electric fires, strengthening the compulsory electrical safety inspection and making it mandatory to report when new or expanding electric facilities, charging a fee for electric safety inspection for detached houses and granting benefits subject to inspection completion, improvement of the electric safety voluntary inspection table and safety indications; It was suggested as a policy to organize and operate electrical safety inspection personnel in a two-person team (mixed), establish a close work cooperation system with related organizations, and strengthen electrical safety education and publicity.

Electrical and Fire Prevention Measures through Improvement of Indoor Wiring, Outlets and Plugs (옥내배선, 콘센트 및 플러그 개선을 통한 전기화재 예방대책)

  • Jeung, Sueng Hyo;An, Hui-Seok;Lee, Yong-Su;Kim, Chang-Eun
    • Journal of the Korea Institute of Construction Safety
    • /
    • v.1 no.1
    • /
    • pp.31-39
    • /
    • 2018
  • It is reported that about 20 % of all fires in Korea are caused by the electric equipment and installations. In complex and large-scale buildings, the sizes of electric fires are becoming larger as property damage and casualties increase. Among the causes of various electric fires, fire by short circuit accounts for about 71.5% of overall fires, and in the classification by electric equipment and installation, fire caused by wiring and wiring equipment accounts for approximately 38.3% of overall fires. The purpose of this study is to propose methods to prevent electric fires due to short circuit by improving indoor wiring currently in use and to find the fundamental measures to prevent wiring equipment caused fires by improving the socket and plug which are commonly used in wiring equipment. It is expected that the electric fire prevention measures presented through this study can be used as a measure to protect many people and properties by eliminating the root cause of electric fire.

Prevention Techniques of Electrical Fire and Electrical Shock Caused by Leakage Current (누설전류로 인한 전기화재 및 감전사고 예방기법)

  • Kim, Dong-Woo;Lim, Young-Bea;Lee, Sang-Ick;Kim, Jae-Hyun;Kang, Dae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.6
    • /
    • pp.82-87
    • /
    • 2013
  • Electrical leakage happens when faults in electrical apparatus or power lines occur. It causes electrical fires and electric shocks. In order to reduce accidents caused by electrical leakage current, it is important to detect faults effectively and shut off the power. In this paper, firstly we analyzed statistics of electrical fires and electric shocks caused by electrical leakage current. Secondly, standards of allowable leakage current and body impedance models were analyzed. Lastly, effective application methods for breaking electrical leakage current were suggested. The results will provide useful preventive measures of electrical fires and electric shocks caused by electrical leakage.

A Study of Fire Prevention Measures for Single-person Households (1인 가구의 화재예방 대책 연구)

  • Kim, Jong Kouk;Han, Dong-Ho
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.1
    • /
    • pp.424-431
    • /
    • 2021
  • This study explores fire prevention measures for single-person households on the phenomenon of an increase in single-person households due to changes in the family structure due to low birthrate and aging population, full marriage, non-marriage, separation, bereavement, and returning to farming villages, and increased flexibility in the labor market. The factor that affects the fire of single-person households is the residential environment problem at the structural level. In terms of behavior, there is an increase in fire occurrence due to the rearing of companion animals. In order to prevent fires in single-person households, safety regulations without exceptions are needed to improve the residential environment at the structural level. At the behavioral level, it is necessary to expand the prevention and safety guidance of related organizations. In addition, as a measure to prevent fire caused by companion animals, manufacturers of electric ranges should develop safety devices to prevent fires caused by companion animals, such as an automatic power-off device or power supply using a timer. It can also be an important means to create and distribute promotional videos of measures necessary to safely raise companion animals, or to develop and distribute disaster preparedness programs implemented in virtual reality.

Mechanism analysis through Water fire case (정수기 화재발생 사례를 통한 재현실험)

  • Lee, Jeong-Il
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.11a
    • /
    • pp.593-618
    • /
    • 2011
  • Development of the economy and the growing income of people interested in the leisure and health has been focused. Past the town common wells and groundwater around the water, but health is a priority these days to solve the drinking water directly from tap water, but most people work from home, through the water purifier has been resolved. Depending on seasonal changes and personal taste of coffee, if you can enjoy a snack and water purifier is a restaurant, lounge, public areas and focusing on the rapid spread of the fire, water purifier as compared to the total number of fires increased by 0.03% per year trend on, but the washrooms fire and fire-related research data and case studies with analysis of the exact cause lack of proper preventive measures are insufficient reality. In this study, focusing on electrical energy using a water cooler to understand the structure and principles of fire, the fire revealed the mechanism is vulnerable to the consideration of factors, the exact cause of the fire investigation and the Assistant, manufacturing defects, and to contribute to fire prevention review should.

  • PDF

A Study on the safety measures for hydrogen cooling system of 500MW class thermal power plant (500MW급 화력발전소 수소냉각시스템의 안전대책)

  • Kim, Soon-Gi;Yuk, Hyun-Dai;Ka, Chool-Hyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.385-390
    • /
    • 2005
  • This paper provided a counter measures against the troubles and accidents that are likely to take place in the power plant using hydrogen gas as a coolant for the cooling system of the generator. Because of the extremely wide flammability limits of hydrogen in comparison to the other flammable gases, the safety measures against the hydrogen accidents is very important to ensure the normal operation of electric-power facility. This study's purpose was a presentation of standard model of safety management of hydrogen equipments in the coal firing power plant such as following items: 1) providing the technical prevention manual of the hydrogen explosions and hydrogen fires occurring in the cooling system of power generator; 2) the selection of explosion-proof equipments in terms of the risk level of operating environment; 3) the establishment of regulations and counter measures, such as the incorporation of gas leakage alarm device, for preventing the accidents from arising; 4) the establishment of safety management system to ensure the normal operation of the power plant.

  • PDF

Development of IoT Sensor-Gateway-Server Platform for Electric Fire Prediction and Prevention (전기화재 예측 및 예방을 위한 IoT 센서-게이트웨이-서버 플랫폼 개발)

  • Yang, Seung-Eui;Kim, Hankil;Song, Hyun-ok;Jung, Heokyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.255-257
    • /
    • 2021
  • During the winter season, when electricity usage increases rapidly every year, fires are frequent due to short circuits in aging electrical facilities in multi-use facilities such as traditional markets and jjimjilbangs, apartments, and multi-family houses. Most of the causes of such fires are caused by excessive loads applied to aging wires, causing the wire covering to melt and being transferred to surrounding ignition materials. In this study, we implement a system that measures the overload and overheating of the wire through a composite sensor, detects the toxic gas generated there, and logs it to the server through the gateway. Based on this, we will develop a platform that can predict, alarm and block electric fires in real time through big data analysis, and a simulator that can simulate fire occurrence experiments.

  • PDF

A study on working out arc detector related regulations (아크 검출기 관련 규정 마련에 관한 연구)

  • Park, Yong-Seo
    • Journal of Digital Convergence
    • /
    • v.16 no.11
    • /
    • pp.115-122
    • /
    • 2018
  • More than 70% of the electric fire cases happen in this country are caused by arc. This paper aims to prepare measures of preventing electric fires resulted from arc by analyzing the technical standards and related regulations on the existing circuit breaker. Based on the study, we concluded that the technical and legal standards of the arc detector should be separately regulated from those of existing circuit breaker, considering the characteristics of arc detectors. Accordingly, we suggested in this paper that the arc detector related regulations should either be added to the existing circuit breaker related regulations, or to be handled separately. For effective prevention of electric fires caused by arc, it is urgently required to install arc detector and it is, therefore, appropriate to make it mandatory to install an arc detector. Under the given circumstance, it is suggested that the arc detector related regulations should be added to the existing regulations for the circuit breaker. The technical standards of arc detectors should reflect the arc judgement specification, breaking threshold of arc and the range of unnecessary signal that breaker should not react to respond.

A Study on the safety measures for the protection of hydrogen cooling system of generator (수소를 냉각매체로 하는 발전기 안전대책에 관한 연구)

  • Lee Choon-Ha;Yuk Hyun-Dai
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.4 s.25
    • /
    • pp.55-61
    • /
    • 2004
  • This paper provided a counter measures against the troubles and accidents that are likely to take place in the power plant using hydrogen gas as a coolant for the cooling system of the generator. Because of the extremely wide flammability limits of hydrogen in comparison to the other flammable gases, the safety measures against the hydrogen accidents is very important to ensure the normal operation of electric-power facility. This study's purpose was a presentation of standard model of safety management of hydrogen equipments in the coal firing power plant such as following items: 1) providing the technical prevention manual of the hydrogen explosions and hydrogen fires occurring in the cooling system of power generator; 2) the selection of explosion-proof equipments in terms of the risk level of operating environment; 3) the establishment of regulations and counter measures, such as the incorporation of gas leakage alarm device, for preventing the accidents from arising, 4) the establishment of safety management system to ensure the normal operation of the power plant.

  • PDF

A Study on the Cause Analysis and Countermeasures of the Traditional Market for Fires in the TRIZ Method (TRIZ 기법에 의한 재래시장 화재의 원인분석과 대책에 관한 연구)

  • Seo, Yong-Goo;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.95-102
    • /
    • 2017
  • The fires in the traditional markets often occur recently with the most of them expanded into great fires so that the damage is very serious. The status of traditional markets handling the distribution for ordinary people is greatly shrunk with the aggressive marketing of the local large companies and the foreign large distribution companies after the overall opening of the local distribution market. Most of the traditional markets have the history and tradition from decades to centuries and have grown steadily with the joys and sorrows of ordinary people and the development of the local economy. The fire developing to the large fire has the characteristics of the problem that the fire possibility is high since all products can be flammable due to the deterioration of facilities, the arbitrary modification of equipment, and the crowding of the goods for sale. Furthermore, most of the stores are petty with their small sizes so that the passage is narrow affecting the passage of pedestrians. Accordingly, the traditional markets are vulnerable to fire due to the initial unplanned structural problem so that the large scale fire damage occurs. The study is concerned with systematically classifying and analyzing the result by applying the TRIZ tool to the fire risk factors to extract the fundamental problem with the fire of the traditional market and make the active response. The study was done for preventing the fire on the basis of it and the expansion to the large fire in case of fire to prepare the specific measure to minimize the fire damage. On the basis of the fire expansion risk factor of the derived traditional market, the study presented the passive measures such as the improvement of the fire resisting capacity, the fire safety island, etc. and the active and institutional measures such as the obligation of the fire breaking news facilities, the application of the extra-high pressure pump system, the divided use of the electric line, etc.