• Title/Summary/Keyword: Electric Fields

Search Result 1,160, Processing Time 0.142 seconds

전계와 자계가 식물씨앗의 발아와 초기생장에 미치는 영향 (Effects of Electric and Magnetic Fields to Seed Germination and Its Early Growth)

  • 문재덕;권남열
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권6호
    • /
    • pp.328-333
    • /
    • 2006
  • All the plants on earth live under an electric and magnetic field because the earth is a magnet and there is an electric field between the charged cloud and the ground. It has been reported that electromagnetic fields influence both the activation of ions and polarization of dipoles in living cells of seeds and plants, though the mechanism of these actions is still poorly understood. In this paper, the effects of the electric and magnetic fields and exposure times to the germination of several vegetable seeds and its early growth have been investigated experimentally to find out the feasibility of a plant factory for mass production of clean and unpolluted vegetables. The germination rate and the growth rate of some seeds under the fields exposed were analysed and compared with those of unexposed ones. It is found that the germination rate and its early growth rate of exposed seeds under the fields were accelerated about 1.1-1.4 and 1.7-2.2 times in maximum compared with those of unexposed ones. But, however, an inhibitory effect on germination and plant early growth were shown in the case of the higher electric and magnetic fields.

A Pathway to Microdomain Alignment in Block Copolymer/Nanoparticle Thin Films under Electric Field

  • Bae, Joonwon
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권9호
    • /
    • pp.2689-2693
    • /
    • 2014
  • The control over microstructure in block copolymer thin films using external electric fields has become an interesting research topic. In this article, the effect of nanoparticle on the microdomain alignments in block copolymer (polystyrene-b-poly(2-vinylpyridine)/nanoparticle (Au) thin films under electric fields has been examined with transmission electron microscopy. The homogeneous dispersion of Au nanoparticles into the block copolymer matrix was achieved by surface modification of nanoparticles with compatible ligands. Compared with the phenomenon seen in the pristine block copolymer thin films, a peculiar alignment behavior was observed in the block copolymer/nanoparticle hybrid thin films under electric fields. In addition, the different pathways observed in the pristine and nanoparticle incorporated block copolymer thin films were also monitored as a function of exposure time. This work can provide the fundamental information for understanding microdomain alignment in block copolymer/nanoparticle thin films under external electric fields.

시변성(時變性) 전계(電界) 측정용(測定用) 센서에 관한 연구 (A study on the sensor for measuring the transient electric fields)

  • 이복희;백용현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.318-321
    • /
    • 1991
  • For measuring the transient electromagnetic fields and related quantities created by disconnector operations in GIS, one needs the wide bandwidth sensors with simple transfer functions. This paper describes a new developed electric field sensor to measure the very fast transient electric fields and voltages, and the measuring principle, design and construction of planar electric field sensor are described. A calibration and/or correction technique of the sensor is investigated which enables an accurate determination of the sensor response to the time-changing electric fields. As a consequence, the low voltage calibrations certify that a rise time of 1.7 [ns] is achieved for the planar electric field sensor and a total bandwidth extending from several Hz to 200 MHz for the measuring system which presents the constant division ratio as a function of frequency.

  • PDF

전철용 성전선로에서 발생되는 극저주파 자기장의 안전성에 관한연구 (Study on Safety Consideration of ELF Magnetic Fields Emanating from Power Transmission Line for Electric Railways)

  • 임용배
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 1999년도 제3회 전자장의 생체영향에 관한 워크숍
    • /
    • pp.156-164
    • /
    • 1999
  • This paper shows that the configuration of power transmission lines currently in place is suitable on the basis of calculated magnetic field strengths. The magnetic fields were computed for typical current distributions on power transmission lines for electric railways, which are characterized by severe load fluctuations and phase distortions. The result of the numerical analysis are compared with th ELF guidelines of magnetic fields from several case studies. The final conclusion reached in that effects of the magnetic fields near power transmission lines for electric railways are not significant enough to cause a biological safety concern.

  • PDF

전국의 송전선로 전자계 측정치와 계산치와의 비교 분석 (An analysis of the measured electric and magnetic fields of transmission lines in Korea)

  • 김상범;조성배;신구용;이동일;김정부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2368-2370
    • /
    • 1999
  • A nationwide survey for electric and magnetic fields(EMFs) near overhead transmission lines has been conducted. The median values of the electric and magnetic fields of 208 transmission lines were 0.50 kV/m and 12.6 mG, respectively. The maximum values were 3.16 kV/m and 125 mG. The measured EMFs were compared with the calculated ones. The causes of the discrepancy between measured and calculated EMFs are also discussed.

  • PDF

Analytical model for the formation of electric fields in parallel-plate capacitors

  • Taehun Jang;Jungmin Moon;Hye Jin Ha;Sang Ho Sohn
    • 과학교육연구지
    • /
    • 제46권2호
    • /
    • pp.212-221
    • /
    • 2022
  • In this study, we propose an analytical model to elucidate the formation of electric fields between two parallel conducting plates. Using nine Gaussian surfaces, we investigated the charge redistributions and electric fields formed by parallel conducting plates when two charged plates get close together. The electric charges are redistributed via a new electrostatic equilibrium to create the electric field of each plates. As a result, the electric field start from + electrode plate to - electrode plate via inducing a new electrostatic equilibrium, implying that the application of Gaussian surfaces to only one of the electrodes of parallel-plate capacitors is deserved. The results will help undergraduate students understand the charge redistribution and the electric field formation in parallel-plate capacitors in a reasonable manner.

송전선로 부근과 가전제품의 전자계 측정 (Measurements of Electric and Magnetic Fields in the Vicinity of Transmission Lines and Electric Appliances)

  • 김상범;조성배;이동일;신구용;김정부
    • 한국전자파학회논문지
    • /
    • 제9권5호
    • /
    • pp.687-697
    • /
    • 1998
  • 최근 국내 전력설비에서 발생하는 전자계에 대한 관심이 증가하고 있지만 이에 대한 정확한 자료 파악은 극히 미미한 실정이다. 본고에서는 송전선로에서 발생하는 전계와 자계의 수준을 알아보기 위하여 전국 1537H의 송전 선로를 대상으로 전계와 자계를 측정하였다. 측정 지점의 전계와 자계 최대치들의 중간값은 각각 0.47 kV /m, 11.6 mG 최고 값은 각각 3.16 kV /m, 125 mG로 나타났으며, 전세계의 전자계 관련 권고치나 기준치에 비해 낮은 값임을 알 수 있었다. 아울러 몇 가지 경우에 대하여 가전제품에서 발생하는 자계와 일일 자계 노출량올 측정 하였고 이를 송전선로의 자계 크기와 비교하였다.

  • PDF

교류 전기장이 인가된 층류 자유제트유동의 변화에 관한 예비 조사 (Preliminary Tests on Change of Free Jet Flow in Laminar with Applying Electric Fields)

  • 김경택;이원준;박정
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.383-386
    • /
    • 2014
  • The characteristics of gas free jet flows in laminar with having applied electric fields have been investigated experimentally. A single electrode configuration was adopted such that electric fields were applied directly to nozzle and thus the surrounding could be an infinite ground. The experimental results showed that breakdown point at laminar flow has been measured by varying the applied voltage and frequency of AC. The effect of applying electric fields to free jet flow in laminar was discussed in detail.

  • PDF

송전철탑 주변에서 전장과 자장의 측정과 분석 (Measurement and Analysis of Electric and Magnetic Fields near a Transmission Tower)

  • 이복희;길형준;안창환;이경옥;박동화;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1827-1829
    • /
    • 1997
  • In this paper, measurement and analysis of ELF electric and magnetic fields due to a transmission line have been carried out and the power frequency field strength measuring system is designed. In order to evaluate electric and magnetic fields associated with 60 Hz electric power transmission and distribution lines, the actual survey near a transmission tower has been made and analyzed. It may be inferred from these results that the maximum electric and magnetic fields strength in the vicinity of a line tower do not exceed 3.5[kV/m] and 20[${\mu}T$]. The results of the field measurements agree with limits and guidelines recommended by various authorized international institutes.

  • PDF

침형 상압 마이크로 플라즈마 장치에서 발생하는 전기장이 세포 사멸에 미치는 효과 (The effect of RF electric fields from an atmospheric micro-plasma needle device on the death of cells)

  • 윤현진;손채화;김규천;이해준
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2249-2254
    • /
    • 2008
  • A non-thermal micron size plasma needle is applicable for medical treatment because it includes radicals, charged particles, ultraviolet emission, and strong electric fields. The electric fields around the plasma needle device driven by a radio frequency wave are investigated in order to calculate the power delivered to the cell. A commercial multi-physics code, CFD-ACE, was utilized for the calculation of electric fields for the optimization of the needle structure. The electric field and energy absorption profiles are presented with the variation of the device structure and the distance between the needle and tissues. The living tissues effectively absorb the radio frequency power from the plasma needle device with the covered pyrex structure.