$SF_6$ 가스중 부분방전시 전계 특징 (The Electric Fields Characteristics of Partial Discharges in $SF_6$)

  • 김해준;박경태;박광서;이현동;김충년;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.145-149
    • /
    • 2001
  • The most of faults in gas insulation of power facilities are caused by partial discharge. Therefore we simulated partial discharge and measured the radiated electromagnetic wave emitted from partial discharge in SF$_{6}$ gas by biconical antenna. This paper describes time delay and electric fields pulse characteristics of radiated electromagnetic waves with distance(1[m], 3[m], 5[m]) between antenna and discharge source.e.

  • PDF

고주파 웰딩기의 유해 전자파 차단에 관한 연구 (A Research on the Shielding of Injurious Electromagnetic Field for High-frequency Welder)

  • 장석용;심재형;김준안;백인환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.447-450
    • /
    • 2002
  • In the surrounding of the electric machinery and equipments occurring of using the electromagnetic fields, other electric machinery or equipments are induced the malfunctions by the radiated and leaked electromagnetic fields. And the human hazardous problems by that effect are being discussed frequently. So efficiently shielding technique of injurious electromagnetic field for high frequency welder is discussed in this paper.

  • PDF

표면전하법을 이용한 일반 3차원 전계해석 (Analysis of 3-Dimensional Electric Fields with Surface Charge Method)

  • 박종근;김광수
    • 대한전기학회논문지
    • /
    • 제34권9호
    • /
    • pp.341-348
    • /
    • 1985
  • This paper deals with a surface charge simulation method of calculating three-dimensional electric fields and capacitance. The principle is to divide the electrode surface into rectangular or triangular elements of which charge density is the linear function of the electrode coordinate and to formulate a linear equation for the coefficients of charge density function and to determine those coefficients by boundary conditions. It has been shown that the method can give satisfactory results for thin rectangular plates where the other methods is difficult to be applied.

  • PDF

고전압 전기장을 이용한 하수처리장 방류수 중의 대장균군 소독에 관한 연구 (A Study on the Disinfection of Coliform Group in the Effluent of Sewage Plant by High Voltage Electric Field Treatment)

  • 이민규;정근식;감상규
    • 한국환경과학회지
    • /
    • 제17권7호
    • /
    • pp.817-826
    • /
    • 2008
  • Using high voltage electric fields induced by high voltage AC (10-12 kV/cm, 20 kHz) and pulsed (20-30 kV/cm, 40 Hz) electric field generator as a semipermanent and environment-friendly disinfecting apparatus, the disinfection effect of coliform group in the effluent of sewage plant was investigated. The effects of electric field strength, treatment time, discharge area of a discharge tube, water quality factors (electric conductivity, pH and SS) on its death rate were examined. The death rate of coliform group was increased with increasing electric field strength and treatment time. For AC and pulsed electric field generator, the critical electric field strength was 6 kV/cm and 2 kV/cm, respectively, and the critical treatment time was 5 min and 2 min, respectively, regardless of electric field strength. Comparing the death rate of coliform group by AC and pulsed electric fields used in this study, its death rate was higher for the latter than the former, but did not increase linearly with increasing electric field strength. The results obtained for the effects of discharge area, electric conductivity, pH and SS on the death rate of coliform group using AC electric field (12 kV/cm, 20 kHz) were as follows: its death rate showed the trend to increase linearly with increasing discharge area; for the effect of electric conductivity, its death rate was increased with increasing electric conductivity, regardless of ionic species, increased with increasing cationic valency, but was similar between the same cationic valency; the pH $5{\sim}9$ used in this study did not affect its death rate; its death rate was decreased with increasing SS concentration.

근로자들의 극저주파 전자파 노출 수준에 따른 인체 영향 평가 (Health Status of Electric Utility Workers Exposed to Extremely Low Frequency Electromagnetic Field (ELF-EMF))

  • 박경호;안용호;김태전
    • 대한임상검사과학회지
    • /
    • 제37권3호
    • /
    • pp.220-227
    • /
    • 2005
  • Recently, the use of an electrical apparatus has brought up concerns of health risks from exposure to electromagnetic fields. EMF is composed of electric fields and magnetic fields. Heavy exposure to EMF can occur only in the vicinity of high-voltage overhead transmission lines, close to transformers and underground cables, and also close to large electrical machinery. In this thesis I have investigated the hypothesis of the correlation between occupational exposure to ELF-EMF and the risks of leukemia, anemia, cancer. Therefore, the aim of this study is to investigate whether or not ELF-EMF emitted from electric power stations and transformer substations affect some hematological parameters and tumor markers of electric utility workers. The hematological test results and tumor markers under investigation were similar in the two groups but some of parameters such as RBC, AFP, LDH showed significant difference between the two groups from two sample t-test (p<0.05). The exposure group showed increased LDH level compared to the control group by two sample t-tests. In addition, the abnormal LDH level in the exposure group was observed to be clinically significant by ${\chi}^2$-test. However, the levels of RBC, AFP observed were not clinically significant by ${\chi}^2$-test (p>0.05). These results suggested that ELF-EMF does not affect most blood test parameters except LDH of electric utility workers.

  • PDF

고차 지그재그 이론을 이용한 열_전기_기계 하중하의 스마트 복합재 쉘 구조물의 해석 (HIGHER ORDER ZIG-ZAG SHELL THEORY FOR SMART COMPOSITE STRUCTURES UNDER THERMO-ELECTRIC-MECHANICAL LOADING)

  • 오진호;조맹효
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.1-4
    • /
    • 2005
  • A higher order zig-zag shell theory is developed to refine accurately predict deformation and stress of smart shell structures under the mechanical, thermal, and electric loading. The displacement fields through the thickness are constructed by superimposing linear zig-zag field to the smooth globally cubic varying field. Smooth parabolic distribution through the thickness is assumed in the transverse deflection in order to consider transverse normal deformation. The mechanical, thermal, and electric loading is applied in the sinusoidal distribution function in the in-surface direction. Thermal and electric loading is given in the linear variation through the thickness. Especially, in electric loading case, voltage is only applied in piezo-layer. The layer-dependent degrees of freedom of displacement fields are expressed in terms of reference primary degrees of freedom by applying interface continuity conditions as well as bounding surface conditions of transverse shear stresses. In order to obtain accurate transverse shear and normal stresses, integration of equilibrium equation approach is used. The numerical examples of present theory demonstrate the accuracy and efficiency of the proposed theory. The present theory is suitable for the predictions of behaviors of thick smart composite shell under mechanical, thermal, and electric loadings combined.

  • PDF

Preventing Method against the Occurrence of a Corona between a Dead End clamp and a Porcelain Insulator Used in 154kV Substation

  • Han, Woon-Ki;Choi, Jong-Soo;Lee, Jun;Kim, Jae-Chul
    • International Journal of Safety
    • /
    • 제6권2호
    • /
    • pp.22-26
    • /
    • 2007
  • An episode of corona is a heterogeneity-caused electric discharge that occurs when electric fields are formed layer on layer and concentrated on an electrode. Electric wires built at the tip of 154kV private facilities use dead end clamp spawns corona from homogeneity caused by field concentration. Corona induces power loss, noise, insulator failure and more. In this research, we've studied the characteristics of coronas that take place in porcelain insulators and terminal electric wires of supporting hard wares (dead end clamp) that are set up as spares in the 154kV private facilities use hydroelectricity installations to support electric wires. Corona, which cannot be identified by regular methods, was measured utilizing UV image camera. As the result of measuring corona via UV image camera, we've confirmed that the depletion of insulators was accelerated following the wire end treatment method and validated the stress intensity of insulators at various lengths of bare wires caused by electric fields via FEMLAB. We have also proposed a new model for relieving homogeneity-caused field concentration, and after analyzing the proposed model via FEMLAB, we've confirmed that the concentration of field distribution was indeed reduced. Such results are exploited in installation of private facilities use equipments, maintenance of insulators and hard wares as well as safety enhancement, and are anticipated to be effectively utilized in corona prevention measures.

교류전기장이 인가된 상태에서 전선을 통해 전파하는 화염에 대한 전선직경의 영향 (Effect of Diameter on Spreading Flame over Electrical Wire with Applied AC Electric Fields)

  • 박순호;임승재;권오붕;박정;정석호
    • 한국연소학회지
    • /
    • 제22권3호
    • /
    • pp.1-7
    • /
    • 2017
  • An experimental study on spreading flame over electrical wire, which was insulated by Polyethylene(PE) and had different diameters, was conducted with applied AC electric field. The result showed that the flame spread rate decreased in increase of the diameter of insulator at a fixed electric field. The flame spread rate exhibited increase or decrease tendency with applied AC electric field, having three distinct regimes depending on applied voltage and frequency. In each regime, the flame spread rate was characterized by physical parameters of applied electric fields and wire dimensions, and the behaviors could be explained by a thermal balance mechanism.

균등전계 중에 놓인 침상 전극의 끝단에서 발생한 직류 코로나방전 특성 (Characteristics of DC Corona Discharges Caused at the tip of a Needle-shaped Electrode Placed in the Homogeneous Electric Fields)

  • 김태기;김승민;이복희
    • 조명전기설비학회논문지
    • /
    • 제29권11호
    • /
    • pp.74-81
    • /
    • 2015
  • In the measurement of atmospheric static electric field, it is important to know characteristics of corona discharges caused at the tip of test electrode. This paper presents the fundamental data of DC corona discharges that occurred at the tip of a needle-shaped electrode placed in the homogeneous background electric field which simulates the atmospheric static field under thundercloud. The major characteristics of interest for this purpose are the polarity effect of corona discharges and the magnitudes and time intervals of corona current pulses. The experimental set-up consists of the plate-to-plate configuration with a needle-shaped protrusion, DC power supply, and voltage and current measuring devices. As a result of experiments, the polarity dependence of corona pulses is significantly pronounced. The time intervals between successive corona pulses in the negative polarity is much longer than those in the positive polarity. The time intervals for both polarities is drastically decreased as the applied electric field is increased. Also the magnitudes of the positive corona pulses are slightly changed with an increase in applied electric field, but those of the negative corona pulses are linearly increased with increasing the applied electric fields.

고전압 펄스 전기장에 의한 Saccharomyces cerevisiae의 세포내·외적 사멸 기작 연구 (Intra- and Extra-cellular Mechanisms of Saccharomyces cerevisiae Inactivation by High Voltage Pulsed Electric Fields Treatment)

  • 이상재;신정규
    • 한국식품과학회지
    • /
    • 제47권1호
    • /
    • pp.87-94
    • /
    • 2015
  • 비가열 살균 기술 중 본격적인 상업적 실용화를 눈앞에 두고 있는 고전압 펄스 전기장에 의한 미생물의 사멸 기작에 대해 살펴보았다. 세포 현탁액을 고전압 펄스 전기장 처리하였을 경우 처리 시간이나 전기장의 세기가 증가할수록 세포 외액으로 세포내 물질의 유출이 증가하였으며, 세포막 투과성의 변화로 인하여 $K^+$, $Na^+$등이 이온 성분의 유출도 나타났다. 염색시약에 의한 세포의 염색에서 처리시간이 증가함에 따라 염색되는 세포의 수가 증가하였으며, 전자현미경에 의한 세포의 관찰 결과 고전압 펄스 전기장 처리를 받은 세포의 경우 처리 받지 않은 것에 비해 표면이 거칠고 굴곡이 있었으며, 세포막이 터져 세포내 물질이 외부로 유출되고 형태가 일그러진 것이 관찰되었다. 항생물질 첨가에 따른 회복 실험에서 고전압 펄스 전기장 처리에 의해 세포의 단백질 합성 체계에 손상을 입었으며, chromosomal DNA의 분리를 통한 DNA의 손상여부 관찰 결과 약 27.3%의 DNA의 손상이 발생했음을 알 수 있었다. 따라서 고전압 펄스 전기장 처리가 세포벽이나 세포막의 손상뿐만 아니라 대사 체계와 DNA에도 손상을 주는 것을 확인할 수 있었다.