• Title/Summary/Keyword: Electric Fields

Search Result 1,155, Processing Time 0.026 seconds

Effects of Pulsed Electric Fields on Juice Expression Characteristics of Malus pumila Fruit (고전압 펄스 전기장 처리가 사과의 착즙 특성에 미치는 영향)

  • Lim, Jeong-Ho;Ahn, Seong-Hwan;Lee, Dong-Un;Kim, Young-Ho;Park, Kee-Jai
    • Food Science and Preservation
    • /
    • v.19 no.5
    • /
    • pp.665-671
    • /
    • 2012
  • The effects of pretreatment by pulsed electric fields (PEFs) on the juice expression characteristics of the Malus pumila fruit were investigated. Fresh fruits were divided into quarters, were produced on a laboratory scale (100 g apples per lot) by pretreatment with electric fields at two different field intensities (1, 2 kV/cm; n=50, 100, 200, and 400 pulses), and were then pressed at room temperature. Relative to the control samples, the juice yield increased with increasing field intensities. The total phenolics and antioxidant activity were higher in the juice from the PEF-treated fruit than in the juice from the untreated fruit. There was no significant difference in soluble-solid and reducing sugar contents between the PEF-treated and untreated fruits. These results suggest that PEF pretreatment may be useful for increasing the juice yield, total phenolics, and antioxidant activity of the Malus pumila fruit.

Analysis of the Electric-field Characteristics of V/UHF Antennas Installed on a Shipboard (함정 탑재 V/UHF 안테나의 전계 특성 분석)

  • Lee, Jin-Ho;Kwon, Joon-Hyuck;Song, Ki-Hwan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.74-80
    • /
    • 2008
  • Analysis of the electromagnetic environment on topside of a ship is needed for optimal arrangement of all kinds of antennas to be installed on the shipboard in order to minimize the probability of EMI of equipment and subsystems in real ship after construction phase. In this paper we analyze the characteristics of electric-fields such as radiation patterns and near E-fields of V/UHF antennas installed on a shipboard. We compare simulated results with measurements on the real ship for near E-fields to verify the reliability of the computed electromagnetic environment. Although there are various factors causing errors such as cable loss and impedance mismatching etc. when measuring near E-field, both data show similar trends in the range of the acceptable tolerance.

Far-Zone Electric Fields Radiated by A Coaxial Cable Through An Aperature In A Perfectly Conducting Ground Plane (무한도체 평면상에 놓여있는 동축 케이블의 개구면을 통하여 복사되는 원거리 전계)

  • 최재훈;성혁재
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.4
    • /
    • pp.56-62
    • /
    • 1994
  • Far-zone electric fields radiated by a coaxial cable through an aperture in a perfectly conducting ground plane are calculated utilizing the dyadic Green's function and vector wave functions. In this paper the outer radius $\alpha$ is assumed to be less than 0.02 so that the aperture fields is well approximated by the dominant TEM mode in the coaxial cable. The result of present approach is compared with the readily obtained solution. The present solution is valid outside of the spherical regions with radius `$\alpha$' from the center of coaxial cable.

  • PDF

Power Frequency Magnetic Field Reduction Method for Residents in the Vicinity of Overhead Transmission Lines Using Passive Loop

  • Lee, Byeong-Yoon;Myung, Sung-Ho;Cho, Yeun-Gyu;Lee, Dong-Il;Lim, Yun-Seog;Lee, Sang-Yun
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.6
    • /
    • pp.829-835
    • /
    • 2011
  • A power frequency magnetic field reduction method using passive loop is presented. This method can be used to reduce magnetic fields generated within the restricted area near transmission lines by alternating current overhead transmission lines. A reduction algorithm is described and related equations for magnetic field reduction are explained. The proposed power frequency magnetic field reduction method is applied to a scaled-down transmission line model. The lateral distribution of reduction ratio between magnetic fields before and after passive loop installation is calculated to evaluate magnetic field reduction effects. Calculated results show that the passive loop can be used to cost-effectively reduce power frequency magnetic fields in the vicinity of transmission lines generated by overhead transmission lines, compared with other reduction methods, such as active loop, increase in transmission line height, and power transmission using underground cables.

Experimental Study on the Stability Enhancement of Nonpremixed Flames in Coflow Jets (동축류 제트에서 전기장에 의한 화염 안정성 증진에 대한 실험적 연구)

  • Won, Sang-Hee;Ryu, Seung-Kwan;Chung, Suk-Ho;Cha, Min-Suk
    • 한국연소학회:학술대회논문집
    • /
    • 2007.05a
    • /
    • pp.191-196
    • /
    • 2007
  • The enhancement of flame stability in coflow jets has been investigated experimentally by observing the liftoff behaviors of nonpremixed propane and methane flames in the electric fields. The liftoff or blowoff velocities has been measured in terms of the applied AC voltages and frequency. The experimental results showed that the liftoff velocity could be extended significantly just by applying the high voltage to the central fuel nozzle both for propane and methane. As increasing the applied voltage, the liftoff velocity increases almost linearly with the applied voltage and have its maximum value at certain applied voltage. After that, the liftoff velocity showed decrease with the applied voltage. Through the experimental observation, we found that the liftoff velocity could be correlated well with the applied voltage and frequency in the linearly increasing regime. And after having maximum in the liftoff velocity, it was observed that the liftoff velocity decreases with the applied voltage irrespective of AC frequencies. To visualize the change of flame structure with electric fields, planar laser induced fluorescence technique was adopted, and the enhancement of flame stability has been explained based on the flame structural change in electric fields.

  • PDF

Underwater Discharge Phenomena in Inhomogeneous Electric Fields Caused by Impulse Voltages

  • Lee, Bok-Hee;Kim, Dong-Seong;Choi, Jong-Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.329-336
    • /
    • 2010
  • The paper describes the electrical and optical properties of underwater discharges in highly inhomogeneous electric fields caused by 1.2/50 ${\mu}s$ impulse voltages as functions of the polarity and amplitude of the applied voltage, and various water conductivities. The electric fields are formed by a point-to-plane electrode system. The formation of air bubbles is associated with a thermal process of the water located at the tip of the needle electrode, and streamer coronas can be initiated in the air bubbles and propagated through the test gap with stepped leaders. The fastest streamer channel experiences the final jump across the test gap. The negative streamer channels not only have more branches but are also more widely spread out than the positive streamer channels. The propagation velocity of the positive streamer is much faster than that of the negative one and, in fact, both these velocities are independent of the water conductivity; in addition the time-lag to breakdown is insensitive to water conductivity. The higher the water conductivity the larger the pre-breakdown energy, therefore, the ionic currents do not contribute to the initiation and propagation of the underwater discharges in the test conditions considered.

Electrical Conduction and Resistance Characteristics of Styrene Butadiene Rubber (SBR) Composites Containing Carbon Black (Styrene Butadiene Rubber (SBR)/ Carbon Black 복합체의 전기저항 및 전기전도 특성)

  • Kim, Do-Hyun;Lee, Jung-Hee;Sohn, Ho-Soung;Lee, Kyung-Won
    • Elastomers and Composites
    • /
    • v.33 no.4
    • /
    • pp.246-254
    • /
    • 1998
  • In order to investigate the characteristics of resistance and conduction of vulcanized styrene butadiene rubber (SBR)/ carbon black (CB) composites, surface/ volume resistivity, point to point resistance, decay time, and electrical conduction experiments with four different kinds of non-conductive carbon black were measured. When about 50phr of carbon black were loaded in SBR, all resistivites suddenly decreased and critical region (Rc) was shown. Current densities of SBR/CB composites showed critical point (Pc) and increased with the electric fields. Electrical conduction mechanisms of SBR/CB composites could be considered as the ohmic conduction at low electric fields and the space charge limited conduction (SCLC) at high electric fields, respectively.

  • PDF

Three-Dimensional Electric Field Calculation around the 345kV Sinmasan Substation Busbars (신마산 345kV 전력소 모선하의 3차원 불평등 전계분포 해석)

  • Myung, Sung-Ho;Lee, Byeong-Yoon;Han, Inn-Su;Park, Jong-Keun;Min, Suk-Won;Kim, Eung-Sik;Lee, Ki-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1804-1806
    • /
    • 1996
  • For the rather complicated and time-consuming three-dimensional electric field calculation in the vicinity of substations, this paper proposes a numerical calculation method based on charge simulation method(CSM). In order to represent non-uniform charge distribution on an electrode better, it is subdivided into small segments with linear charge density. Non-uniform arrangement of subdivided segments makes it possible to obtain high accuracy with a small number of variables. As for the arrangement of subdivided segments, effective formulars were derived from multiple regression analysis of many simulations. These formulars make the arrangement of segments fast and effective. The proposed method is applied to the electric field calculation around the 345kV Sinmasan Substation busbars and the distribution of calculated electric fields is compared with that of the measured electric fields.

  • PDF

Inactivation of Lactobacillus plantarum by High Voltage Pulsed Electric Fields Treatment (고전압 펄스 전기장 처리에 의한 Lactobacillus plantarum의 불활성화)

  • Shin, Hae-Hun;Pyun, Yu-Ryang
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.1175-1183
    • /
    • 1997
  • Lethal effects of high voltage pulsed electric fields (PEF) on suspensions of Lactobacillus plantarum cells in phosphate buffer solution were examined by using continuous recycle treatment system. Critical electric field strength and treatment time needed for inactivation of L. plantarum were 13.6 kV/cm and $16.1\;{\mu}s$ at room temperature, respectively. As decrease in frequency (decreasing pulse number), the degree of inactivation of L. plantarum was increased. A 2.5 log reduction in microbial population could be achieved with an electric field strength of 80 kV/cm, 300 Hz frequency and $2000\;{\mu}s$ treatment time. Survivability was decreased with increase in total treatment time (cycle number) and frequency at the same cycle number. As sterilization model of continuous recycle PEF treatment, $logS=-N_m\;log\;m+B$ and $N_m=k_1\;P_n+k_2$ were established. This model was very well fitted to tile empirical data. The rate of inactivation increased with increase in the processing temperature. The maximum reduction in survivability (5.6 log reduction) was obtained with 80 kV/cm electric field strength at $50^{\circ}C$ for $1000\;{\mu}s$ treatment.

  • PDF

Electrorheological Properties of Anhydrous ER Suspensions Based on Phosphated Cellulose (인산처리 셀룰로오스를 첨가한 비수계 ER 유체의 전기유변학적 특성)

  • 안병길;최웅수;권오관;문탁진
    • Tribology and Lubricants
    • /
    • v.14 no.2
    • /
    • pp.1-9
    • /
    • 1998
  • The electrorheological (ER) behavior of suspensions in silicone oil of phosphated cellulose particles (average particle size 17.77 ${\mu}{\textrm}{m}$) was investigated at room temperature with electric fields up to 2.5 KV/mm. In this paper, for development of anhydrous ER suspensions using at wide temperature range, we would like to know fundamental understandings on the ER activity. As a first step, the anhydrous ER suspensions dispersed the phosphated cellulose particles were measured, and not only the electrical characteristics such as dielectric constant, current density and electrical conductivity but also the rheological properties on strength of electric field and quantity of dispersed phase were studied. From the experimental results, the anhydrous ER suspensions dispersed phosphated cellulose particles showed a stable current density and very high performance of ER effect $(\tau/\tau_0=1030)$ on the 2.5 KV/mm and the dynamic yield stress $(\tau_y)$ was in exponential proportion to the strength of electric fields.