• Title/Summary/Keyword: Electric Field strength

Search Result 465, Processing Time 0.027 seconds

Triboelectrostatic Separation System for Separation of PVC and PS Materials Using Fluidized Bed Tribocharger

  • Lee, Jae-Keun;Shin, Jin-Hyouk;Hwang, Yoo-Jin
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.10
    • /
    • pp.1336-1345
    • /
    • 2002
  • A triboelectrostatic separation system using a fluidized bed tribocharger for the removal of PVC material in the mixture of PVC/PS plastics is designed and evaluated as a function of electric field strength, air flow rate, and the mixing ratio of two-component mixed plastics. It consists of a fluidized-bed tribocharger, a separation chamber, a collection chamber and a controller. PVC and PS particles can be imparted negative and positive surface charges, respectively, due to the difference in the work function values of plastics suspended in the fluidized-bed tribocharger, and can be separated by passing them through an external electric field. Experimental results show that separation efficiency is strongly dependent on the electric Deld strength and particle mixing ratio. In the optimum conditions of 150 Ipm air flow rate and 2.6 kV/cm electric field strength a highly concentrated PVC (99.1%) can be recovered with a yield of more than 99.2% from the mixture of PVC and PS materials for a single stage of processing.

Maximum Electric Field Strength Prediction of WCDMA Base Station Using Pilot Channel (Pilot 채널을 이용한 WCDMA 기지국의 최대 전기장 강도 예측)

  • Lee, Yeong-Su;Yoon, Hyun-Goo;Jang, Byung-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.10
    • /
    • pp.1016-1019
    • /
    • 2011
  • In this paper, we predict a maximum electric field strength of WCDMA base station using a pilot channel in a code domain. In order to verify the feasibility of our method, we compare our predicted value on a self-designed test base station with a general electric field strength measurement value at a full-traffic load condition and with a calculated value by a ray-tracing technique. Predicted results show above 90 % agreement with the general measurement and calculation values. We also show that our prediction method can be applied to electric field measurement on a real operating base station. Therefore, it is concluded that our prediction method be an effective method to measure a maximum electric field strength in a base station inspection test.

The Analysis for Electric Field Strength on the Ground Level from DMB Transponder in Stratosphere HAPS (성층권 고공항등체 DMB 트랜스폰더의 지표면 수신전계 강도 분석)

  • Kuk Jay-Il;Chinn Yong-Ok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.1A
    • /
    • pp.16-22
    • /
    • 2006
  • This papers described with the analysis for electric Field strength on ground level transmitted from DMB transponder in stratosphere HAPS. It is compare with horizontal propagated ground wave. Resultly we confirm the equal strength a electric field on ground level between hish altitude vertical propagated wave and horizontal ground wave, also, is only 1W compare with terrestrial facility as transmitted output power for the DMB transponder in stratosphere HAPS. It is corresponding to 1Kw as same power value in ground propagated wave. Lastly it is new material wave source and also we concluding remarks as ubiquitous communication networking media.

Study on the Vibration Control Characteristics of ER Actuator for Application in Intelligence Process Control Systems(PLC) (지능형 공정제어 시스템 적용을 위한 ER 작동기의 진동제어 특성에 관한 연구)

  • Jang, Sung-Cheol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.4 no.1
    • /
    • pp.49-55
    • /
    • 2005
  • This paper presents experiments on the evaluation of characteristics of ER fluids used for vibration control of application in intelligence type process control systems. Dynamic characteristics of the actuator(beam) embedded with the ER fluid can be controlled by changing the strength of the electric field applied on the ER fluids, thus provides a mean to avoid the resonance. In case electric field is supplied to the smart structure with ER fluids, vibration energy is dissipated more than the beam without electric field, because particles in ER fluid form a chain structure in the presence of electric field. The damping and stiffness of the beam with ER fluid are increased when the applied electric field increases. The characteristics of damping and stiffness of the ER fluid with various electric field strength were investigated by conducting a vibration test of the beam with ER fluid. If it applies characteristics of the ER fluids, it will be able to apply in the PLC control system for the vibration which occurs from process system.

  • PDF

Measurement and Analysis of the Atmospheric Electric Field using Balloon-Carried E-Field Sensor (비양기구로 운반되는 전계센서를 이용한 대기전계의 측정과 분석)

  • Kim, Seung-Min;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.78-84
    • /
    • 2016
  • This paper is focused on the measurement and analysis of an atmospheric electric field which is caused by thunderclouds. The electric field due to thunderclouds changes very slowly. For this reason, the extremely low frequency E-field sensor needs to be used for measuring the atmospheric electric field strength. The balloon-carried E-field sensor system with the time constant of 1sec was designed and fabricated. The electric field sensor consists of $100mm{\times}100mm$ copper plate, active integrator, high pass and low pass filters and batteries. The measurements of atmospheric electric fields were made by the balloon-carried E-field sensor and radiosonde, which sends the data back to ground in real time. From the calibration experiments, the response sensitivity of the E-field sensor was 0.154mV/kV/m in the frequency range of less than 1kHz. As a result from the actual experiment of the atmospheric electric field, the electric field signals were observed from the altitude of about 2.5km. Also, as the altitude was increased, the detected electric field wave oscillated with the fluctuation of sensing plate. The proposed method seems suitable for measurements of atmospheric electric fields, because it is inexpensive, simple to use and launch.

Design and Performance Test of Plate Type ER-Valve (평판형 ER-Valve의 제작 및 성능실험)

  • 장성철;염만오
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.6
    • /
    • pp.29-35
    • /
    • 2003
  • In this research 4 plate type ER-Valves which have same surface but different width and length are designed and an experimental apparatus is constructed. With this experimental apparatus, flow rate and pressure drop of ER fluid flowing in ER-valves are measured with varying electric field strength of ER-valve, and relation between valve types and pressure drop is also experimented. ER fluid is made silicon oil mixed with 40wt% starch having hydrous particles. If we allow the same electric field in the ER-Valve, we came to how that the pressure drop is effected by the electrode length and electrode width. When the strength of the electric field increased, the pressure drop happened big and the flow rate decreased.

Decreasing Technique of the Electric-field Intensity on Transmission Conductor Surface using the Hybrid Conductor Bundle (2종소도체 배열방식을 적용한 송전도체 표면전계강도 저감기법)

  • Lee, Dong-Il;Sin, Gu-Yong;Kim, Jeong-Bu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.7
    • /
    • pp.542-549
    • /
    • 1999
  • Corona discharges form at the surface of a transmission line conductor when the electric-field intensity on the conductor surface exceeds the breakdown strength of air. In order to decrease the electric-field intensity on the conductor surface, a new 6 conductor bundle has been studied. This bundle, hybrid conductor bundle, consists of using a larger subconductor at the bottom two conductor positions in the 6-conductor bundles of each phase of the line. The electric field on these two larger subconductors is reduced which in turn reduces the corona noise. It is shown that this is a better solution for decreasing the electric-field intensity than ether the conventional bundle or the asymmetric bundle proposed by EPRI.

  • PDF

The Effect of External DC Electric Field on the Atmospheric Corrosion Behaviour of Zinc under a Thin Electrolyte Layer

  • Liang, Qinqin;YanYang, YanYang;Zhang, Junxi;Yuan, Xujie;Chen, Qimeng
    • Corrosion Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.54-59
    • /
    • 2018
  • The effect of external DC electric field on atmospheric corrosion behavior of zinc under a thin electrolyte layer (TEL) was investigated by measuring open circuit potential (OCP), cathodic polarization curve, and electrochemical impedance spectroscopy (EIS). Results of OCP vs. time curves indicated that the application of external DC electric field resulted in a negative shift of OCP of zinc. Results of cathodic polarization curves measurement and EIS measurement showed that the reduction current of oxygen increased while charge transfer resistance ($R_{ct}$) decreased under the external DC electric field. Variation of OCP negative shift, reduction current of oxygen, and $R_{ct}$ increase with increasing of external DC electric field strength as well as the effect of external DC electric field on double-layer structure in the electrode/electrolyte interface and ions distribution in thin electrolyte layer were analyzed. All results showed that the external DC electric field could accelerate the corrosion of zinc under a thin electrolyte layer.

Developments of Low Frequency Electric Field Sensor using $Ti:LiMbO_3$ Optical Modulator ($Ti:LiMbO_3$ 광변조기를 이용한 저주파 전계센서의 개발)

  • Choi, Young-Kyu
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.214-221
    • /
    • 2001
  • The use of an asymmetric Mach-Zehnder interferometric amplitude modulator to measure a relatively low frequency electric field strength is described. The sensitivity of an electric field sensor using a $Ti:LiMbO_3$ optical modulator is strongly affected by the shape of a electrode(probe antenna). To measure the low frequency electric field, a probe antenna of wide effective area is more useful than the usual dipole antenna. As a proof of this, the optical modulator was fabricated with a plate-type probe antenna and the usefulness of this antenna tested for measuring low frequency electric field strength. Measurements were performed in the range 0.1 V/cm to 60 V/cm at 60Hz through 100 kHz. Using a probe antenna of $10\;mm{\times}10\;mm$, the output voltage of $10^{-2}\;mV$ was measured with respect to the electric field strength of 0.1 V/cm at 60 Hz. By increasing the effective area of the probe antenna, better sensitivity is obtainable over the measured range.

  • PDF

Developments of Extremely Low Frequency Electric Field Sensor using Guided-wave Optical Modulator (광도파로형 초저주파(ELF) 전계계측 센서의 개발)

  • Choe, Yeong-Gyu;Kim, Mun-Hwan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.6
    • /
    • pp.1-7
    • /
    • 2002
  • The use of an asymmetric Mach-Zehnder interferometric amplitude modulator to measure a relatively low frequency electric field strength is described. The sensitivity of an electric field sensor using a Ti:LiNbO$_3$ optical modulator is strongly affected by the shape of a electrode(probe antenna). To measure the low frequency electric field, a probe antenna of wide effective area is more useful than the usual dipole antenna. As a proof of this, the optical modulator was fabricated with a plate-type probe antenna and the usefulness of this antenna tested for measuring low frequency electric field strength. Measurements were performed in the range 0.1V/cm to 60V/cm at 60Hz through 100KHz. Using a probe antenna of 10mm$\times$10mm, the output voltage of 10㎷ was measured with respect to the electric field strength of 0.1V/cm at 60Hz. By increasing the effective area of the probe antenna, better sensitivity is obtainable over the measured range.