• 제목/요약/키워드: Electric Field strength

검색결과 465건 처리시간 0.028초

고전압 전기장을 이용한 하수처리장 방류수 중의 대장균군 소독에 관한 연구 (A Study on the Disinfection of Coliform Group in the Effluent of Sewage Plant by High Voltage Electric Field Treatment)

  • 이민규;정근식;감상규
    • 한국환경과학회지
    • /
    • 제17권7호
    • /
    • pp.817-826
    • /
    • 2008
  • Using high voltage electric fields induced by high voltage AC (10-12 kV/cm, 20 kHz) and pulsed (20-30 kV/cm, 40 Hz) electric field generator as a semipermanent and environment-friendly disinfecting apparatus, the disinfection effect of coliform group in the effluent of sewage plant was investigated. The effects of electric field strength, treatment time, discharge area of a discharge tube, water quality factors (electric conductivity, pH and SS) on its death rate were examined. The death rate of coliform group was increased with increasing electric field strength and treatment time. For AC and pulsed electric field generator, the critical electric field strength was 6 kV/cm and 2 kV/cm, respectively, and the critical treatment time was 5 min and 2 min, respectively, regardless of electric field strength. Comparing the death rate of coliform group by AC and pulsed electric fields used in this study, its death rate was higher for the latter than the former, but did not increase linearly with increasing electric field strength. The results obtained for the effects of discharge area, electric conductivity, pH and SS on the death rate of coliform group using AC electric field (12 kV/cm, 20 kHz) were as follows: its death rate showed the trend to increase linearly with increasing discharge area; for the effect of electric conductivity, its death rate was increased with increasing electric conductivity, regardless of ionic species, increased with increasing cationic valency, but was similar between the same cationic valency; the pH $5{\sim}9$ used in this study did not affect its death rate; its death rate was decreased with increasing SS concentration.

분산계 ER유체의 빙햄특성에 관한 기초적 연구 (A Fundamental Study on Bingham Characteristics of Dispersive Electro-Rheological Fluids)

  • 장성철;염만오
    • 한국기계가공학회지
    • /
    • 제2권3호
    • /
    • pp.48-55
    • /
    • 2003
  • This study investigates the effect of temperature and electric field strength on the Bingham characteristics of Electro-Rheological(ER) fluids which change their Yield shear stress and viscosity by temperature and electric field strength. It is found that under constant temperature the Yield sheal stress and viscosity of ER fluids proportionally increase with the applied electric field strength, and under constant applied electric field strength the Yield shear stress and viscosity of ER fluids decrease with the increasing temperature. These results are considered to be applied to the fluid and pneumatic power industry.

  • PDF

전기하전식 세정집진장치 개발에 관한 기초 연구 (A Basic Study on Developing an Electrocharged Scrubber)

  • 김종호
    • 한국대기환경학회지
    • /
    • 제15권1호
    • /
    • pp.33-39
    • /
    • 1999
  • This study has been performed to develop an efficient electrocharged scrubber. To improve collection efficiency of the scrubber, electric-charger was installed at the forefront of the packed crossflow scrubbers, and an experiment of changing discharge electrode shape and fluctuating electric field strength was undertaken. After using a light-oil boiler for generation of particles in the about 80% weight of submicron size particles was exhausted. Collection characteristics of the electrocharged scrubber were similar to those of two-stage electrostatic precipitator. In this study the collection efficiency of submicron size particles has been much improved, compared with the previous ones. In an experiment of changing discharge electrode and electric field strength, a needle-spike shape wire electrode showed a higher collection efficiency than round shape wire. The collection efficiency becomes increased with an increase of electric field strength.

  • PDF

평행평판 간극에서 전기장의 강도변화에 따른 분산계 ER유체의 유량-압력강하 특성 (Flow Rate-Pressure Drop Characteristics of Dispersive ER Fluid According to Change of Electric Field Strength in Clearance between Parallel Plates)

  • 장성철;염만오;김도태
    • 한국공작기계학회논문집
    • /
    • 제12권1호
    • /
    • pp.78-83
    • /
    • 2003
  • Electro-rheological(ER) fluids are suspensions in which rheological properties show an abrupt change with variation of electric fields. We modeled the parallel-plates relating to ER-Valve system and yielded shear stress according to the strength of electric field. The purpose of the present study is to examine the flow characteristics of ER fluids according to the strength of electric field between parallel-plates. Then the steady relationship between pressure drop and flow rate of the ER fluids between parallel-plates under application of an electric fields was measured. The pressure drop and flow rates of ER fluids under the application of electric fields for steady flow were measured. For the experiment, we used the ER fluids, 35w% zeolite having hydrous particles and differential pressure gauge. This test reviewed experiment for the special changes of ER fluids in the steady flow condition.

Stability of liquid crystal alignment to the electric field

  • Oh, Yu-mi;Im, Ji-Young;Lee, Eun-Kyu;Kim, Jong-Hyun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.834-837
    • /
    • 2006
  • We observed the destruction of the liquid crystal alignment with the repeating scan of strong DC electric field. The strong electric field seems to force the alignment to be scarred permanently and it accumulated with the repetition. In this report we connected alignment destruction behavior and electric field strength to obtain information on the alignment strength. And we compared the behavior between different alignment techniques.

  • PDF

간접활선용 압축 슬리브를 이용한 전선 직선접속에 대한 실험적 연구 (Experimental Study on Tensile Strength of Straight-Line Connection Using Sleeve for Indirect Method)

  • Kim, Sang-Bong;Kim, Kang-Sik;Oh, Gi-Dae;Song, Won-Keun;Keum, Ui-Yeon
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권1호
    • /
    • pp.85-91
    • /
    • 2021
  • With the social atmosphere of respect for human life and the increasing interest in safety of field workers, research and development is underway in various ways to transform direct live method into indirect live method in the field of distribution. As part of this measure, it was necessary to convert electric pole and complex facilities work from machining power distribution to indirect live operation, and install a straight connecting sleeve that connects cut wires for by-pass method, but it failed to meet the tensile strength standard when constructing a sleeve constructed by direct method. In this paper, the design factors were derived based on the case of overseas similar sleeves and the tensile strength evaluation of each variable was performed, based on the analysis of these test results, the method for securing tensile strength of straight-line access sleeves for indirect running was presented.

Strong Electric Field in Ultra High Vaccum

  • Shin, Sunghwan;Kim, Youngsoon;Kang, Hani;Kang, Heon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.262-262
    • /
    • 2013
  • In surface chemistry area, many scientists studied the electrochemical reaction by changing work-function of metal; however, these methods had the weakness that it did not create the electric field. Unlike earlier studies, our capacitor-method makes a strong electric field in ice film. This electric field was induced by soft landing $Cs^+$ ions on ice film, and the strength was measured by the vibrational Stark shift of acetonitrile. In our system, the electric field strength is $10^9$ V/m and it is almost same in the electrochemical cell. This capacitor model provides new method to investigate the electrochemical reaction in vacuum system.

  • PDF

135kHz 이하 미약 전계강도 무선기기 기술기준 개선 방안 및 제안 (Reforming Method and Proposal for the Technical Regulation of Extremely Electric Filed Strength Radio Equipment below 135kHz)

  • 김선엽;정찬권;강영진
    • 한국정보통신학회논문지
    • /
    • 제14권1호
    • /
    • pp.9-15
    • /
    • 2010
  • 본 논문에서는 135kHz 이하 미약 무선국의 전계 강도(기술 기준)에 대한 현재 각국의 동향과 그 기준치를 분석 및 비교를 통하여 해당 대역의 국내기준의 문제점을 분석하였다. 전자파 적합 등록에서 제시하고 있는 각국의 전계 강도 기준치와 연계하여 이에 적합한 국내의 비허가 무선기기(미약 무선기기)의 실질적인 도입 가능한 전계 강도의 기준치를 제시함을 목적으로 한다. 본 논문에서 제시한 전계 강도 허용치를 바탕으로 국내 기준을 상향하면 미약 무선기기 의 보급과 발전에 기여할 것으로 예상되며 국내 통신 시장은 물론 국제 통신 시장에서 경쟁력을 갖출 수 있을 것으로 예상된다.

평판형 ER-Valve의 성능실험에 관한 연구 (Study on Performance Test of Plate Type ER-Valves)

  • 장성철;염만오;김도태;박재범
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.321-324
    • /
    • 2002
  • Hydraulic valve control the pressure and the How of fluid by the hydraulic oil transfered from pump but the ER fluid consists of solid particles of micrometer in size and insulating oil so in the general hydraulic valve. We invented ER-Valve using ER fluid as working fluid. The ER fluid, working fluid of ER-Valve is a functional fluid to represent the feature of fluid according to strength of electric field. In this research we made our own 4 types of plate type ER-Valve which has same surface but different width and length and then we conducted performance test. We measured flow rate and pressure drop of fluid which is flowing in the ER-Valve according to the electric field strength to conduct this test. We modeling ER-Valve relating to ER-Valve system and yield shear stress according to the strength of electric field. We used the pressure drop according to the strength of electric field by differential pressure gauge in the our own made ER-Valve. This test reviewed experimental the special changes of ER-Fluid in the steady flow condition.

  • PDF

적층형 세라믹 압전 액추에이터의 전계강도와 압축응력에 따른 변위특성 해석 (Electric Field Strength and Compressive Stress Effects on the Displacement of Multilayered Ceramic Actuators)

  • 송재성;정순종;김인성;민복기
    • 한국전기전자재료학회논문지
    • /
    • 제18권3호
    • /
    • pp.248-252
    • /
    • 2005
  • The effects of electric field strength and mechanical compressive stress on the displacement of multilayered ceramic actuator, stacked alternatively 0.2 (PbM $n_{1}$3/N $b_{2}$3/ $O_3$)-0.8(PbZ $r_{0.475}$ $Ti_{0.525}$ $O_3$) ceramic thin films and 70Ag-30Pd electrodes were investigated. Because the actuators were designed to stack ceramic layer and electrode layer alternatively, the ceramic-electrode interfaces may act as a resistance to motion of domain wall. so the polarization and strain were affected by the amount of 180$^{\circ}$domain, electric field strength and mechanical compressive stress. Consequently, the change of polarization, displacement with respect to field strength, and mechanical compressive stress were likely to be caused by readiness of the domain wall movement around the ceramic-electrode interfaces.ces.