• Title/Summary/Keyword: Electric Field Exposure

검색결과 89건 처리시간 0.024초

이온화방사선 피폭에 의한 골수세포의 Ornithine Decarboxylase 활성도의 변화에 대한 전계장의 영향에 관한 실험적 연구 (An Experimental Study on the Effect of Electric Field the Ornithine Decarboxylase Activity Change of Myeloid Cells According to Ionizing Radiation Exposure)

  • 정문호
    • 한국환경보건학회지
    • /
    • 제21권1호
    • /
    • pp.78-85
    • /
    • 1995
  • Ornithine decarboxylase(ODC) is an indicate enzyme in carcinogenesis. We divided Sprague Dawley rats into six groups: control, electric field exposure, X-ray only irradiation, X-ray irradiation with electric field exposure group, Sr-90 injected group and Sr-90 and electric field complex exposure group. The ODC activity was measured in rat's bone marrow cell every week. The results were summarized as follows: The ODC activitied was increased in X-ray irradiated, Sr-90 injected and Sr-90 and electric field complex exposed group as compared with that of control(p<0.05). The ODC activity was increased comparing that of control neither in X-ray and electric field complex exposed group nor electric field only exposed group. This result suggests that the electric field doesn't have myeloid carcinogenicity and myeloid cancer incidence caused by ionized radiation is suppressed by electric field exposure.

  • PDF

Strontium 90의 골수 발암성에 대한 전계장의 영향에 관한 실험적 연구 (A Study on Effect of Electric Field for Carcinogenesis of Strontium 90)

  • 정문호;두옥주
    • 한국환경보건학회지
    • /
    • 제20권3호
    • /
    • pp.61-77
    • /
    • 1994
  • Sprague Dawley rats were exposed to electric fields (6,000 V, 10 kV/m, 30 min/day, 6 days per week) and injected strontium 90 (681 kbq/rat, one time) through abdominal cavity (strontium 90 and electric field complexed exposure group). In parallel, series with the electric field exposure only, strontium 90 injection only and control groups were run. Every group was consisted of 110 rats (55 male and 55 female). This animal experiment was performed from May to December in 1993. This results were conducted to investigate the effect of electric field for 11 weeks. The results are summarized as follows: 1. Ornithine decarboxylase (ODC) activity in rat's bone marrow cells: The ODC values was significantly increased in Sr$^{90}$ injection group and Sr$^{90}$ and electric field complexed exposure group as compared with that of control group (p<0.05). The ODC value was significantly decreased in electric field and Sr$^{90}$ complexed exposure group in comparison with Sr$^{90}$ injection group (p<0.05). The ODC values of electric field only exposure group was not different to that of control group (p>0.05). 2. The amount of Sr$^{90}$ accumulation in the femur, kidney and spleen:The accumulation amount of Sr$^{90}$ in the femur of Sr$^{90}$ injection group represented higher value than that of electric field and Sr$^{90}$ complexed exposure group (p<0.05). In the kidney and spleen, the difference between electric field and Sr$^{90}$ complexed exposure group and Sr$^{90}$ injection group wasn't observed. 3. The counts of white cells in blood of Sr9?injection group was decreased as compared with the value from control group and electric field and Sr$^{90}$ complexed exposure group (p<0.05). The rat's body weight, red blood cell counts and the weight data of liver, kidney and spleen did not show differences among four groups.

  • PDF

Development of a New Personal Magnetic Field Exposure Estimation Method for Use in Epidemiological EMF Surveys among Children under 17 Years of Age

  • Yang, Kwang-Ho;Ju, Mun-No;Myung, Sung-Ho;Shin, Koo-Yong;Hwang, Gi-Hyun;Park, June-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.376-383
    • /
    • 2012
  • A number of scientific researches are currently being conducted on the potential health hazards of power frequency electric and magnetic field (EMF). There exists a non-objective and psychological belief that they are harmful, although no scientific and objective proof of such exists. This possible health risk from ELF magnetic field (MF) exposure, especially for children under 17 years of age, is currently one of Korea's most highly contested social issues. Therefore, to assess the magnetic field exposure levels of those children in their general living environments, the personal MF exposure levels of 436 subjects were measured for about 6 years using government funding. Using the measured database, estimation formulas were developed to predict personal MF exposure levels. These formulas can serve as valuable tools in estimating 24-hour personal MF exposure levels without directly measuring the exposure. Three types of estimation formulas were developed by applying evolutionary computation methods such as genetic algorithm (GA) and genetic programming (GP). After tuning the database, the final three formulas with the smallest estimation error were selected, where the target estimation error was approximately 0.03 ${\mu}T$. The seven parameters of each of these three formulas are gender (G), age (A), house type (H), house size (HS), distance between the subject's residence and a power line (RD), power line voltage class (KV), and the usage conditions of electric appliances (RULE).

국내 거주환경에서의 전자기장 노출평가를 위한 Wire code의 타당성에 관한 연구 (Application of a Wire code in Domestic Residential EMF Studies)

  • 탁상우;김현;김록호
    • 한국환경보건학회지
    • /
    • 제26권3호
    • /
    • pp.55-60
    • /
    • 2000
  • Wire codes, introduced by Wertheimer and Leeper, are interesting largely because several case-control studies have reported associations between them and certain types of cancers, including childhood leukemia. This paper is concerned with the reliability of wire codes as a surrogate for residential electric and magnetic field, divided into four categories based on the electrical wiring within 40m of homes. To examine the correlation between spot measurements and wire codes, EMF was measured by using HI-3604 and classified by wire codes. The correlation between long-transformed RMS of magnetic field and wire codes was 0.81. But the correlation between log-transformed RMS of electric field and wire codes was 0.27. The results led us to determine a four category from of the Wertheimer and Leeper code that 1) may be useful in domestic epidemiological studies and 2) is not suitable for electric field exposure. Thus, the critical point of exposure assessment in residential magnetic field is to classify a wire code precisely.

  • PDF

송전선로에서 전류와 자계의 상관관계 분석 (Analysis on the relation between electric current and magnetic field near transmission lines)

  • 조성배;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.3-5
    • /
    • 1997
  • The relation between electric current and magnetic field under three overhead transmission lines being operated was studied. It was examined for a difference each other in comparison with calculated value and measured value for current, magnetic field. With magnetic field equations made out, The magnetic field distribution around transmission lines had made to figure out with easy by load electric current value. Additionally, we are going to describe the distribution curve of magnetic exposure volume for KEPCO's T/L.

  • PDF

Effects of 60-Hz Time-Varying Electric Fields on DNA Damage and Cell Viability Support Negligible Genotoxicity of the Electric Fields

  • Yoon, Yeo Jun;Li, Gen;Kim, Gyoo Cheon;Lee, Hae June;Song, Kiwon
    • Journal of electromagnetic engineering and science
    • /
    • 제15권3호
    • /
    • pp.134-141
    • /
    • 2015
  • The effect of a 60 Hz time-varying electric field was studied using a facing-electrode device (FED) and a coplanar-electrode device (CED) for further investigation of the genotoxicity of 60 Hz time-varying magnetic field (MF) from preceding research. Neither a single 30-minute exposure to the CED or to the FED had any obvious biological effects such as DNA double strand break (DSB) and apoptosis in cancerous SCC25, and HeLa cells, normal primary fibroblast IMR90 cells, while exposures of 60 Hz time-varying MF led to DNA damage with induced electric fields much smaller than those used in this experiment. Nor did repetitive exposures of three days or a continuous exposure of up to 144 hours with the CED induce any DNA damage or apoptosis in either HeLa or IMR90 cells. These results imply that the solitary electric field produced by time-varying MF is not a major cause of DSBs or apoptosis in cancer or normal cells.

송전선로 부근과 가전제품의 전자계 측정 (Measurements of Electric and Magnetic Fields in the Vicinity of Transmission Lines and Electric Appliances)

  • 김상범;조성배;이동일;신구용;김정부
    • 한국전자파학회논문지
    • /
    • 제9권5호
    • /
    • pp.687-697
    • /
    • 1998
  • 최근 국내 전력설비에서 발생하는 전자계에 대한 관심이 증가하고 있지만 이에 대한 정확한 자료 파악은 극히 미미한 실정이다. 본고에서는 송전선로에서 발생하는 전계와 자계의 수준을 알아보기 위하여 전국 1537H의 송전 선로를 대상으로 전계와 자계를 측정하였다. 측정 지점의 전계와 자계 최대치들의 중간값은 각각 0.47 kV /m, 11.6 mG 최고 값은 각각 3.16 kV /m, 125 mG로 나타났으며, 전세계의 전자계 관련 권고치나 기준치에 비해 낮은 값임을 알 수 있었다. 아울러 몇 가지 경우에 대하여 가전제품에서 발생하는 자계와 일일 자계 노출량올 측정 하였고 이를 송전선로의 자계 크기와 비교하였다.

  • PDF

A New Method to Estimate the Induced Electric Field in the Human Child Exposed to a 100 kHz-10 MHz Magnetic Field Using Body Size Parameters

  • Park, Young-Min;Song, Hye-Jin;Byun, Jin-Kyu
    • Journal of Magnetics
    • /
    • 제19권2호
    • /
    • pp.174-180
    • /
    • 2014
  • In this paper, a new and simple method is proposed to quickly estimate the induced electric field in the human child exposed to a 100 kHz-10 MHz magnetic field, for the sake of electromagnetic field (EMF) safety assessment. The quasi-static finite-difference time-domain (FDTD) method is used to calculate the induced electric fields in high resolution 3D human child models with various body size parameters, in order to derive the correction factor for the estimation equation. The calculations are repeated for various frequencies and incident angles of the magnetic field. Based on these calculation results, a new and simple estimation equation for the 99th percentile value of the body electric field is derived that depends on the body size parameters, and the incident magnetic field. The estimation errors were equal to or less than 5.1%, for all cases considered.

UHF 대역 RFID 시스템에서 전자기장의 인체노출량 측정 및 분석 (Assessment and Analysis of Human EMF Exposure to UHF RFID System)

  • 변진규;윤재훈
    • 조명전기설비학회논문지
    • /
    • 제23권1호
    • /
    • pp.132-140
    • /
    • 2009
  • UHF 대역 RFID 시스템의 전자기장 인체노출량 평가를 위하여 900[MHz] 대역 상용 RFID 시스템에 대하여 전기장 분포를 실측하고 분석했다. 또한 RFID 리더 안테나의 전자파흡수율(SAR)을 시뮬레이션을 이용하여 계산하고 인체보호기준에 명시된 기본한계와 비교하여 안전성을 확인했다. EN 및 IEC 국제표준에 따라 RFID 시스템 주위의 인체노출량을 평가하기 위하여 리더기 동작을 테스트하고, 안테나로부터의 방위각과 거리에 따른 전기장 강도를 측정 후 그 결과를 분석하였다. 계측기로는 협대역 등방성 전기장 프로브를 사용하였으며, 리더기 주변 360[$^{\circ}$] 범위에서 15[$^{\circ}$] 간격으로 각각 0.3, 0.5, 1.0, 1.5[m]의 거리에서 측정을 수행했다. 또한 측정 결과로부터 EN및 IEC 표준에서 정의된 측정거리의 타당성에 대해 분석했다.

The Effect of Pulse Electric Field on Accumulation of Selenium in Cells of Saccharomyces cerevisiae

  • Pankiewicz, Urszula;Jamroz, Jerzy
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권7호
    • /
    • pp.1139-1146
    • /
    • 2007
  • Cultures of Saccharomyces cerevisiae were subjected to the effect of PEF (pulse electric field) and a source of selenium. The culture period after which yeast cells were subjected to PEF treatment was optimized, as was the duration of the exposure. Optimization of the nutrient medium composition in S. cerevisiae cultures resulted in an over 1.8-fold increase in selenium accumulation with relation to cultures on the initial substrate. Optimization of the pH value and of culture duration resulted in selenium accumulation increase by approximately 78%. A significant correlation was found between the accumulation of selenium in yeast cells and its concentration in the culture substrate. The highest accumulation of selenium in the biomass of yeast, approx. $240\;{\mu}g/g$ d.m., was obtained after 15-min exposure to PEF on a 20-h culture. An approx. 50% higher content of selenium in cells was recorded, as compared with the control culture without the application of PEF.