• 제목/요약/키워드: Electric Appliances

검색결과 294건 처리시간 0.022초

하이브리드 자동차용 고압 케이블의 온도 특성에 관한 연구 (A Study on the Temperature Characteristics of High Voltage Power Cable for Hybrid Electric Vehicle)

  • 이기연;김동우;김동욱;길형준;김향곤;최충석
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.338-342
    • /
    • 2008
  • Hybrid Electric Vehicle(HEV) is driven by an internal-combustion engine and an electric motor. It is a combination of an internal-combustion engine and several electrical equipments which use a high voltage battery, an electric motors, an inverter and others. But there is not any separate detailed enforcement regulations for high voltage electric appliances in the existing vehicle-related safety standards. So, test standards suggestion as well as test technique development need to be done for ensuring electrical safety, for an electric motor, a high voltage battery, a(n) inverter/converter and an electric power transmission units and other equipments to ensure the safety of high voltage electric appliances which is the HEV key electrical component. In this paper, We are to provide helpful data to support test technique development and test standard establishment for HEV design and electrical safety security by the following methods; by measuring the voltage, the electric current, and the frequency of HEV, by analyzing electrical characteristics of high voltage electric appliances, and by analyzing temperature characteristics of the electrical current among the analyzed electrical characteristics by thermal imagining cameras.

대기전력차단으로 인한 에너지절약과 전기화재예방에 관한 연구 (A Study on the Energy Saving and Electric Fire Prevention was Caused by with Interception of Standby Electric Power)

  • 김만건;임성진;이창우
    • 한국화재조사학회논문지
    • /
    • 제11권1호
    • /
    • pp.66-73
    • /
    • 2008
  • 본 연구에서는 한국전기안전공사 서울지역본부 내 전기 전자 제품을 선정하여 각 기기의 전력사용량을 측정하고, 각 기기에 대해 대기전력 차단장치인 세이버 설치 전 후의 대기전력을 측정함으로서 평상시와 전원의 "OFF"시 대기전력을 비교함으로서 절전효과를 조사하였다. 연구결과 대기전력 차단장치인 세이버를 설치하였을 경우 전기 에너지 낭비요인을 원천적으로 제거함으로서 약 18%의 절전효과가 있었으며, 대기전력을 차단함으로서 전기화재를 근원적으로 예방하고 서지 등 이상전압에 의한 충격을 방지함으로서 전기 전자제품의 수명을 연장할 수 있었다.

  • PDF

4M 기법을 활용한 전기화재 예방대책 수립 연구 (A Study on the Establishment of Preventive Measures for Electric Fires Using the 4M Technique)

  • 오택흠;박찬석
    • 대한안전경영과학회지
    • /
    • 제23권4호
    • /
    • pp.23-29
    • /
    • 2021
  • The purpose of this study is to reduce the probability of occurrence of electric fires as a preemptive preventive measure, and to strengthen the capability of preventing electric fires by strengthening the cooperative function between electric fire-related departments and establishing a cooperative system. In this study, the general aspects of electric fires were identified by reviewing the literature such as ignition mechanisms of electric fires. And the major electrical fires that occurred in the last 10 years were classified into ignition factors (short circuit, overload/overcurrent, and earth leakage/ground fault) and ignition sources (wiring/wiring appliances, electrical equipment/household appliances). And the 4M technique was used to analyze the potential causes of ignition at the fire site and to suggest preventive measures. In the case In this study, out of 48 electrical fires in the past 10 years, 16 short-circuit fires, 3 overload/overcurrent fires, 3 short-circuit and earth fault fires, 16 fires in wiring/wiring appliances, and 10 fires in electrical equipment/home appliances classified as cases. And prevention measures were presented in terms of human, machine, media, and management by using the 4M technique. For the preemptive prevention of electric fires, strengthening the compulsory electrical safety inspection and making it mandatory to report when new or expanding electric facilities, charging a fee for electric safety inspection for detached houses and granting benefits subject to inspection completion, improvement of the electric safety voluntary inspection table and safety indications; It was suggested as a policy to organize and operate electrical safety inspection personnel in a two-person team (mixed), establish a close work cooperation system with related organizations, and strengthen electrical safety education and publicity.

가전제품 화재 메커니즘 재현 및 분석을 위한 인프라 구축 (The Infrastructure Case for Reproduction or Analysis of The Mechanism on The Fire of The Electrical Appliances)

  • 장인혁;이창훈;이영주;임홍우
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제15권1호
    • /
    • pp.60-66
    • /
    • 2015
  • In this paper, The infrastructure case for reproduction or analysis of the mechanism on the fire or the electrics shock of the electrical appliances is proposed. The various electrical appliances(Washing machine, Ballast, Electric heaters, Electronic switches, Mobile phone chargers) used in the home can be tested on the high voltage and over current test through the implementation of the infrastructure. The electrical tests of fire and electric shock consists of the high voltage of maximum 5000 V and over current test of 3 steps(90 A, 60 A, 40 A) and noise test. The mechanism of the fire and the electric shock tests reproduced are analyzed through the monitoring system and the oscilloscope. The electronics manufacturers can prevent accidents through the tests of the electronics factor reproduced and the analysis of the infrastructure designed.

각종 전기기기 및 장소에서의 전자파 측정 (Electromagnetic Forces Measurement of Various Electric Appliances and Places)

  • 김덕원;류창용;김수찬;윤형로
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.179-182
    • /
    • 1995
  • Although air, water, and noise pollutions have been widely recognized, electromagnetic forces(EMF) hazard has been rarely recognized as a pollution and very little studies has been done in this country. Thus, in this study electromagnetic forces radiated by various home appliances, once machines, and communication equipments were measured and so were several places radiating strong EMF such as subway stations and electric substations. Among the home appliances microwave oven senates lots of magnetic field and microwaves, and electric mattress does strong magnetic field. In video game room strong magnetic and considerable electric fields were measured. It was observed strong magnetic field inside of electric powered train and very strong magnetic and electric fields on some platforms. Hand-phone and car-phone radiate very hazardous level of microwaves to brain and that they rapidly come into wide use. In this study data base for various electric machines and places radiating strong EMFs were constructed and could be used for future epidemiological studies.

  • PDF

스마트플러그(IOT)를 이용한 대학시설의 전기에너지 사용량 계측 및 분석 사례 연구 (A Case Study of Measuring and Analyzing Electric Energy Usage in University Facilities Using Smart Plug)

  • 박준영;이춘경;박태근
    • 대한건축학회논문집:구조계
    • /
    • 제34권9호
    • /
    • pp.27-34
    • /
    • 2018
  • The purpose of this study is to demonstrate and analyze the function of a Smart Plug before and after it is applied on the electrical appliances by controlling standby power usage. The research measures and analyzes the amount of electrical energy used while activating the Smart Plug with two types of appliances in a university facilities. The smart plugs were applied into a Group 1 appliances (Multi-function device, computer, laptop, Air con) which completely hinder the standby power, and a Group 2 appliances (Refrigerator, cold and hot water dispenser) which does not completely hinder the standby powers due to the characteristics of the function. First, the total standby power saving of all electrical appliances (Group 1 and Group 2) using the Smart plug was measured as 4.59%. Second, the energy saving of the Group 1 products was analyzed as 26.43%. Third, the standby power saving of the air conditioners from mid October to early December was measured as 31.06%, during the seasons when air conditioning was not actively in use. The research indicates that all specified appliances did have better energy efficiency with the Smart plug regardless of the amount of energy usage.

Multi-Objective Optimization Model of Electricity Behavior Considering the Combination of Household Appliance Correlation and Comfort

  • Qu, Zhaoyang;Qu, Nan;Liu, Yaowei;Yin, Xiangai;Qu, Chong;Wang, Wanxin;Han, Jing
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1821-1830
    • /
    • 2018
  • With the wide application of intelligent household appliances, the optimization of electricity behavior has become an important component of home-based intelligent electricity. In this study, a multi-objective optimization model in an intelligent electricity environment is proposed based on economy and comfort. Firstly, the domestic consumer's load characteristics are analyzed, and the operating constraints of interruptible and transferable electrical appliances are defined. Then, constraints such as household electrical load, electricity habits, the correlation minimization electricity expenditure model of household appliances, and the comfort model of electricity use are integrated into multi-objective optimization. Finally, a continuous search multi-objective particle swarm algorithm is proposed to solve the optimization problem. The analysis of the corresponding example shows that the multi-objective optimization model can effectively reduce electricity costs and improve electricity use comfort.

Modeling and Simulation of Smart Home Energy Consumption

  • Naziha Labiadh;Imen Amdouni;Lilia El Amraoui
    • International Journal of Computer Science & Network Security
    • /
    • 제24권6호
    • /
    • pp.77-82
    • /
    • 2024
  • The Smart home energy consumption represents much of the total energy consumed in advanced countries. For this reason, the main objectif of this paper is to study the energy consumption profile by day for each home appliances: controllable appliances for example Washing machine, Tumble dryer and Air conditioning and uncontrollable appliances for example TV, PC, Lighting, Refrigerator and Electric heater. In this paper, we start with presentation of a smart home energy management systems. Next, we present the modeling and simulation of controllable appliances and uncontrollable appliances. Finally, concludes this paper with some prospects. The modeling and the simulation of a Smart home appliances is based on MATLAB/Simulink software.

가전제품의 하역 중 낙하충격에 관한 연구 (A Study on the Dropping Shock of Household Electric Appliances during Materials Handling)

  • 이수근
    • 한국포장학회지
    • /
    • 제6권1호
    • /
    • pp.37-40
    • /
    • 2000
  • This study was carried out to investigate dropping shock of household electric appliances during materials handling. Microwave oven($18{\ell}$), TV(16") and washing machine(6.2kg) were singled out as the study items. From the results of dropping test by KS A 1026(General Rules of Performance Testing for Packaged Freights), relative equations were gained as follow : y=0.0863x+10.032 for microwave oven, y=0.136x+7.85 for TV and y=0.214x+5.8 for washing machine (where y is G-factor and x is Dropping height). The maximum values of dropping shock during materials handling were measured to be $11{\sim}14G$ for microwave oven, $12{\sim}15G$ for TV and $10{\sim}12G$ for washing machine. The maximum shocks of microwave oven, TV and washing machine during materials handling were corresponding to dropping shocks of dropping height 45.98cm, 52.57cm and 28.97cm by KS A 1026.

  • PDF