• Title/Summary/Keyword: Elbow method

Search Result 381, Processing Time 0.026 seconds

Coordination Pattern of Upper Limb of Sweep Shot Movement in Ice Hockey (아이스하키 스위프 샷(Sweep shot) 동작의 상지의 협응 형태)

  • Choi, Ji-Young;Lee, Eui-Lin
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.169-179
    • /
    • 2007
  • The purpose of this study was to investigate the relations between the segments of the body and to qualitatively analyze coordination pattern of joints and segments during Sweep Shot movement in Ice Hockey, by utilizing coordination variables was angle vs. angle plots. By the utilization the three dimensional anatomical angle cinematography, the angles of individual joint and segment according to sweep shot in ice hockey. The subjects of this study were five professional ice hockey players. The reflective makers were attached on anatomical boundary line of body. For the movement analysis three dimensional cinematographical method(APAS) was used and for the calculation of the kinematic variables a self developed program was used with the LabVIEW 6.1 graphical programming(Johnson, 1999) program. By using Eular's equations the three dimensional anatomical Cardan angles of the joint and ice hockey stick were defined. The three dimensional anatomical angular displacement and coordination pattern of trunk and Upper limb(shoulder-elbow, elbow-wrist linked system) showed important role of sweep shot in ice hockey. As the result of this paper, for the successful movement of sweep shot in ice hockey, it is most important role of coordination pattern of trunk-shoulder, shoulder-elbow and elbow-wrist. specially turnk movememt as a proximal segment. Coordination pattern of Upper Limb(upperarm-forearm-hand) of Sweep Shot movement in Ice Hockey that utilizes coordination variables seems to be one of useful research direction to understand basic control mechanisms of Ice hockey sweep shooting linked system skill. this study result showed flexion-extension, adduction-abduction and internal-external rotation of trunk are important role of power and shooting direction coordination pattern of upper Limb of Sweep Shot movement in Ice Hockey.

Anterior Subcutaneous Ulnar Nerve Transposition for Cubital Tunnel Syndrome (주관 증후군에 대한 척골 신경 전방 피하 전위술)

  • Pyun Young-Sik;Jeon Si-Hyun;Yeo Kyung-Ki;Bae Ki-Cheol
    • Clinics in Shoulder and Elbow
    • /
    • v.8 no.1
    • /
    • pp.36-42
    • /
    • 2005
  • Purpose: To evaluate the clinical results of anterior subcutaneous ulnar nerve transposition operation and the factors that influence the results for cubital tunnel syndrome. Materials and Methods: Seventeen cases of cubital tunnel syndrome were treated by anterior subcutaneous transposition between March 2001 and December 2003. The mean age was 56 years and mean follow up period was 20.4 months. All patients were reviewed retrospectively. The preoperative evaluation was done by Dellon's classification and the clinical results were evaluated by Messina’s classification. We analyzed the effect of the operation and the relations between the results and the preoperative factors, for example, duration of symptom, age, cause of illness, present of association with diabetes mellitus or preoperative flexion contracture of the elbow were analyzed. Results: The results according to Messina's classification were 4 cases of excellent, 9 cases of good, 3 cases of fair, and 1 case of poor. The preoperative factors like duration of symptom, age, cause of illness and flexion contracture of the elbow didn't show any statistical difference in the result of operation, but the cases which have diabetes mellitus were unsatisfactory with statistical difference (p=0.018). Conclusion: Anterior subcutaneous ulnar nerve transposition is relatively easy and good operative method in cubital tunnel syndrome.

The Comparison of Muscle Activity in 4 Sections of Rectus Abdominis by The Distance of The Shoulder Width and The Angle of The Elbow Joint in The Position of Push-Up (푸시 업 자세 시 팔굽관절 각도와 어깨넓이 간격에 따른 구획별 4 배 곧은근 근활성도 비교)

  • Moon, Kyo Hoon;Kim, Kyung Hun
    • Journal of Korean Physical Therapy Science
    • /
    • v.24 no.1
    • /
    • pp.14-21
    • /
    • 2017
  • Background; This study was to investigate effects of distance of muscle activity of 4 sections of rectus abdominis(RS-RA, LS-RA, RI-RA, LI-RA) by the shoulder width(x0.5, x1.0, x1.5) and the angle of the elbow joint($0^{\circ}$, $45^{\circ}$, $90^{\circ}$) Method : This study was conducted on 20 healthy male and 20 female adult. respectively, elbow joints were maintained at $0^{\circ}$, $45^{\circ}$, and $90^{\circ}$ flex postures on The shoulder width is 0.5, 1.0, and 1.5 times. at the same time 4 sections of rectus abdominis were measured using EMG with maintaining isometric contraction of the rectus abdominis for 5 seconds. Results; The results were as follows: First, muscle activity of 4 sections of rectus abdominis(RS-RA, LS-RA, RI-RA, LI-RA) by angle of the elbow joint($0^{\circ}$, $45^{\circ}$, $90^{\circ}$) was a statistically significant(p<0.05), Second, muscle activity of 4 sections of rectus abdominis(RS-RA, LS-RA, RI-RA, LI-RA) by the shoulder width(x0.5, x1.0, x1.5) was a statistically non-significant Conclusion; It was found to be most effective to perform arm posture with rectus abdominis muscle strength exercise.

  • PDF

Failure Criteria of a 6-Inch Carbon Steel Pipe Elbow According to Deformation Angle Measurement Positions (변형각의 측정 위치에 따른 6인치 탄소강관엘보의 파괴 기준)

  • Yun, Da Woon;Jeon, Bub Gyu;Chang, Sung Jin;Park, Dong Uk;Kim, Sung Wan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.13-22
    • /
    • 2022
  • This study proposes a low-cycle fatigue life derived from measurement points on pipe elbows, which are components that are vulnerable to seismic load in the interface piping systems of nuclear power plants that use seismic isolation systems. In order to quantitatively define limit states regarding leakage, i.e., actual failure caused by low-cycle fatigue, in-plane cyclic loading tests were performed using a sine wave of constant amplitude. The test specimens consisted of SCH40 6-inch carbon steel pipe elbows and straight pipes, and an image processing method was used to measure the nonlinear behavior of the test specimens. The leakage lines caused by low-cycle fatigue and the low-cycle fatigue curves were compared and analyzed using the relationship between the relative deformation angles, which were measured based on each of the measurement points on the straight pipe, and the moment, which was measured at the center of the pipe elbow. Damage indices based on the combination of ductility and dissipation energy at each measurement point were used to quantitatively express the time at which leakage occurs due to through-wall cracking in the pipe elbow.

Comparative Study About The Indirect Blood Pressure (measured by different Instruments and Methods) (측정도구와 방법에 따른 간접혈압측정치의 비교연구)

  • Suh Gil-Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.1 no.1
    • /
    • pp.51-68
    • /
    • 1994
  • One aim of this study was to find out the difference of indirect blood pressure between the types of instruments. The difference of indirect blood pressure was measured with mercury sphygomomanometer and electronic blood pressuremeter. Another was to determine the difference of indirect blood pressure according to width of cuff and site of cuff. Indirect blood pressures were measured with the diaphragmatic side of sphygomomanometer. The subjects were 40 female volunteers, whose arm circumferences were from 22 to 34cm. The data were analyzed by SPSS-PC program and pared t-test was used. The results are summarized as follows ; 1. Mercury sphygomomanometer systolic pressure was higher(average 2.20mmhg) than electronic blood pressuremeter. It was statistically significant(p=0.026). 2. The value of Mercury sphygomomanometer diastolic pressure was lower(2.00mmhg) than electronic's. It was statistically significant(p=0.03) 3. In the mercury sphygomomanometer systolic pressure, the value of standard cuff($12{\times}23cm$) was higher(2.40mmhg) than large one's($14{\times}45cm$). It was statistically significant(p=0.007). 4. In diastolic pressure(K4), the value of standard cuff was higher(0.65mmhg) than large cuff's. It was not statistically significant(p=0.481). In K5, the value of standard cuff($12{\times}23cm$) was higher(0.55mmhg) than large cuff's. It was not statistically significant(p=0.541). 5. Difference according to site of showed that the values of systolic pressure over elbow joint were higher(20.00mmhg, 26.45mmhg) than ones at site of elbow joint. It was significant statistically(p=0.000) and clinically. 6. The values of diastolic pressure(K4) over elbow joint were higher(17.10mmhg, 21.60mmhg) than ones at site of elbow joint. It was significant statistically (p=0.000) and clinically. The values of K5 over elbow joint were higher(17.25mmhg, 22.15mmhg) than ones at site of elbow joint. It was significant statistically(p=0.000) and clinically. I think similar studies about indirect blood pressure according to diseases and positions are necessary. In addition, similar studies, are required about accuracy of method electronic blood pressuremeter according to site of mesurement.

  • PDF

Treatment of Acromioclavicular Joint Injuries Using Clavicle Hook Plates (Clavicle Hook Plate를 이용한 견봉 쇄골 관절 손상의 치료)

  • Kim, Myung-Ho;Seo, Joong-Bae;Moon, Sang-Young
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.92-98
    • /
    • 2010
  • Purpose: To analyze results of treating acromioclavicular injuries using clavicle hook plates. Materials and Methods: Between February 2008 and April 2010, 18 patients with acromioclavicular joint injury treated by clavicle hook plates were reviewed. Using the Rockwood classification, 7 dislocations were classified as type III injuries and 11 as type V injuries. Implant removal was done at least 3 months from initial fixation. Simple X-rays were taken for comparing the state of reduction, and clinical outcomes were evaluated by the Korean Shoulder Scoring System and the American Shoulder Elbow Society score. The average follow-up period was 9 months. Results: On weight bearing X-rays, the average coracoclavicular distance showed a 114% increase compared to the contralateral side at the time of injury. It decreased to 23% by the last follow-up. The mean Korean Shoulder Scoring System and the American Shoulder Elbow Society score were 80 and 74 at the last follow-up. Conclusion: The immediate stability these plates provide allows rapid rehabilitation. Clavicle hook plate fixation for acromioclavicular joint dislocation is considered an effective method for ensuring satisfactory results both radiologically and clinically.

Development of Elbow Joint X-ray Examination Aid for Medical Imaging Diagnosis (의료영상 진단을 위한 팔꿉관절 X-선 검사 보조기구 개발)

  • Hyeong-Gyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.127-133
    • /
    • 2024
  • The elbow joint is made up of three different bones. X-rays or other radiological exams are commonly used to diagnose elbow injuries or disorders caused by physical activity and external forces. Previous research on the elbow joint reported a new examination method that meets the imaging evaluation criteria in the tilt position by Z-axis elevation of the forearm. Therefore, this study aims to design an optimized instrument and develop an aid applicable to other upper extremity exams. After completing the 2D drawing and 3D modeling design, the final design divided into four parts was fabricated with a 3D printer using ABS plastic and assembled. The developed examination aid consists of a four-stage Z-axis elevation tilt angle function (0°, 5°, 10°, and 15°) and can rotate and fixate 360° in 1-degree increments. It was designed to withstand a maximum equivalent stress of 56.107 Pa and a displacement of 1.6548e-5 mm through structural analysis to address loading issues caused by cumulative frequency of use and physical utilization. In addition to X-ray exams of the elbow joint, the developed aid can be used for shoulder function tests by rotating the humerus and also be applied to MRI and CT exams as it is made of non-metallic materials. It will contribute to the accuracy and efficiency of medical imaging diagnosis through clinical applications of various devices and medical imaging exams in the future.

Limit State Evaluation of Elbow Components Connected with Flexible Groove Joints (유동식 그루브 조인트로 연결된 엘보 요소의 한계상태 평가)

  • Sung-Wan Kim;Da-Woon Yun;Bub-Gyu Jeon;Dong-Uk Park;Sung-Jin Chang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.3
    • /
    • pp.91-99
    • /
    • 2024
  • Piping systems are crucial facilities used in various industries, particularly in areas related to daily life and safety. Piping systems are fixed to the main structures of buildings and facilities but do not support external loads and serve as non-structural elements performing specific functions. Piping systems are affected by relative displacements owing to phase differences arising from different behaviors between two support points under seismic loads; this can cause damage owing to the displacement-dominant cyclic behavior. Fittings and joints in piping systems are representative elements that are vulnerable to seismic loads. To evaluate the seismic performance and limit states of fittings and joints in piping systems, a high-stroke actuator is required to simulate relative displacements. However, this is challenging because only few facilities can conduct these experiments. Therefore, element-level experiments are required to evaluate the seismic performance and limit states of piping systems connected by fittings and joints. This study proposed a method to evaluate the seismic performance of an elbow specimen that includes fittings and joints that are vulnerable to seismic loads in vertical piping systems. The elbow specimen was created by connecting straight pipes to both ends of a 90° pipe elbow using flexible groove joints. The seismic performance of the elbow specimen was evaluated using a cyclic loading protocol based on deformation angles. To determine the margin of the evaluated seismic performance, the limit states were assessed by applying cyclic loading with a constant amplitude.

The Effectiveness of Arthroscopic Debridement with Mini-Open Ulnar Nerve Decompression in Primary Osteoarthritis of the Elbow with Ulnar Neuropathy (척골 신경 병증을 동반한 주관절 퇴행성 관절염에서 최소 절개 척골 신경 감압술과 동시에 시행한 관절경적 변연 절제술의 효과)

  • Jegal, Midum;Yu, Kun-Woong;Park, Sung-Bae;Kim, Jong-Pil
    • Journal of the Korean Orthopaedic Association
    • /
    • v.52 no.1
    • /
    • pp.15-24
    • /
    • 2017
  • Purpose: The aim of this study was to determine the effectiveness of arthroscopic debridement with mini-open ulnar nerve decompression in primary osteoarthritis of the elbow with ulnar neuropathy. Materials and Methods: Between May of 2006 and July of 2014, a total of 43 patients who had undergone surgery for primary osteoarthritis of the elbow with ulnar neuropathy were included in this study. We divided the subjects into two groups according to the method of surgery: group 1 (n=18) received mini-open ulnar nerve decompression only, and group 2 (n=25) received arthroscopic debridement with mini-open ulnar nerve decompression. Patients were assessed for the following clinical outcomes: visual analogue scales (VAS) score, range of motion of the elbow joint, Mayo elbow performance score (MEPS), and disabilities of the arm, shoulder and hand (DASH) at the time before surgery and 6 months after surgery. We analyzed the recovery of the ulnar nerve by the McGowan grade and Bishop rating score preoperatively and at 6 months after the surgery. Results: The VAS score, range of motion of the elbow joint, MEPS, and DASH showed significant statistical difference after the surgery (p<0.05). However, between the 2 groups, there was no significant difference. For the McGowan grade, all cases of both groups-except one case each group-showed at least one grade improvement. Moreover, group 2 showed a greater significant difference than group 1 (p=0.001). At the final follow-up, according to the Bishop rating score, group 2 had a greater significant difference than group 1 (p=0.036). Conclusion: Arthroscopic debridement with mini-open ulnar nerve decompression in primary osteoarthritis of the elbow with ulnar neuropathy is a useful technique, which has several advantages, including the benefits associated with a minimally invasive surgery and also the improvement of elbow joint function and excellent recovery of the ulnar nerve.

RHadoop platform for K-Means clustering of big data (빅데이터 K-평균 클러스터링을 위한 RHadoop 플랫폼)

  • Shin, Ji Eun;Oh, Yoon Sik;Lim, Dong Hoon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.27 no.3
    • /
    • pp.609-619
    • /
    • 2016
  • RHadoop is a collection of R packages that allow users to manage and analyze data with Hadoop. In this paper, we implement K-Means algorithm based on MapReduce framework with RHadoop to make the clustering method applicable to large scale data. The main idea introduces a combiner as a function of our map output to decrease the amount of data needed to be processed by reducers. We showed that our K-Means algorithm using RHadoop with combiner was faster than regular algorithm without combiner as the size of data set increases. We also implemented Elbow method with MapReduce for finding the optimum number of clusters for K-Means clustering on large dataset. Comparison with our MapReduce implementation of Elbow method and classical kmeans() in R with small data showed similar results.