• Title/Summary/Keyword: Elbow method

Search Result 382, Processing Time 0.022 seconds

Comparative Study on Axes of Rotation Data by Within-Subjects Designs (피험자내 설계에 의한 회전축자료의 비교연구)

  • Kim, Jinuk
    • The Korean Journal of Applied Statistics
    • /
    • v.26 no.6
    • /
    • pp.873-887
    • /
    • 2013
  • The axis of rotation in biomechanics is a major tool to investigate joint function; therefore, many methods to estimate the axis of rotation have been developed. However, there exist several problems to describe, estimate, and test the axis statistically. The axis is directional data(axial data) and it should not be analyzed with traditional statistics. A proper comparative method should be considered to compare axis estimating methods for the same given data ANOVA (analysis of variance) is a frequently used statistical method to compare treatment means in experimental designs. In case of the axial data response assumed to come from Watson distribution, there are a few ANOVA method options. This study constructed ANOVA models for within-subjects designs of axial data. Two models (one within-subjects factor and two within-subjects factors crossed design) were considered. The empirical data used in this study were instantaneous axes of rotation of flexion/extension at the knee joint and the flexion/extension and pronation/supination at the elbow joint. The results of this study can be further applied to the various analysis of experimental designs.

Curriculum Mining Analysis Using Clustering-Based Process Mining (군집화 기반 프로세스 마이닝을 이용한 커리큘럼 마이닝 분석)

  • Joo, Woo-Min;Choi, Jin Young
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.4
    • /
    • pp.45-55
    • /
    • 2015
  • In this paper, we consider curriculum mining as an application of process mining in the domain of education. The basic objective of the curriculum mining is to construct a registration pattern model by using logs of registration data. However, subject registration patterns of students are very unstructured and complicated, called a spaghetti model, because it has a lot of different cases and high diversity of behaviors. In general, it is typically difficult to develop and analyze registration patterns. In the literature, there was an effort to handle this issue by using clustering based on the features of students and behaviors. However, it is not easy to obtain them in general since they are private and qualitative. Therefore, in this paper, we propose a new framework of curriculum mining applying K-means clustering based on subject attributes to solve the problems caused by unstructured process model obtained. Specifically, we divide subject's attribute data into two parts : categorical and numerical data. Categorical attribute has subject name, class classification, and research field, while numerical attribute has ABEEK goal and semester information. In case of categorical attribute, we suggest a method to quantify them by using binarization. The number of clusters used for K-means clustering, we applied Elbow method using R-squared value representing the variance ratio that can be explained by the number of clusters. The performance of the suggested method was verified by using a log of student registration data from an 'A university' in terms of the simplicity and fitness, which are the typical performance measure of obtained process model in process mining.

Effects of the Selection of Deformation-related Variables on Accuracy in Relative Position Estimation via Time-varying Segment-to-Joint Vectors (시변 분절-관절 벡터를 통한 상대위치 추정시 변형관련 변수의 선정이 추정 정확도에 미치는 영향)

  • Lee, Chang June;Lee, Jung Keun
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.156-162
    • /
    • 2022
  • This study estimates the relative position between body segments using segment orientation and segment-to-joint center (S2J) vectors. In many wearable motion tracking technologies, the S2J vector is treated as a constant based on the assumption that rigid body segments are connected by a mechanical ball joint. However, human body segments are deformable non-rigid bodies, and they are connected via ligaments and tendons; therefore, the S2J vector should be determined as a time-varying vector, instead of a constant. In this regard, our previous study (2021) proposed a method for determining the time-varying S2J vector from the learning dataset using a regression method. Because that method uses a deformation-related variable to consider the deformation of S2J vectors, the optimal variable must be determined in terms of estimation accuracy by motion and segment. In this study, we investigated the effects of deformation-related variables on the estimation accuracy of the relative position. The experimental results showed that the estimation accuracy was the highest when the flexion and adduction angles of the shoulder and the flexion angles of the shoulder and elbow were selected as deformation-related variables for the sternum-to-upper arm and upper arm-to-forearm, respectively. Furthermore, the case with multiple deformation-related variables was superior by an average of 2.19 mm compared to the case with a single variable.

A Multi-chip Microelectrofluidic Bench for Modular Fluidic and Electrical Interconnections (전기 및 유체 동시접속이 가능한 멀티칩 미소전기유체통합벤치의 설계, 제작 및 성능시험)

  • Chang Sung-Hwan;Suk Sang-Do;Cho Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.4 s.247
    • /
    • pp.373-378
    • /
    • 2006
  • We present the design, fabrication, and characterization of a multi-chip microelectrofluidic bench, achieving both electrical and fluidic interconnections with a simple, low-loss and low-temperature electrofluidic interconnection method. We design 4-chip microelectrofluidic bench, having three electrical pads and two fluidic I/O ports. Each device chip, having three electrical interconnections and a pair of two fluidic I/O interconnections, can be assembled to the microelectofluidic bench with electrical and fluidic interconnections. In the fluidic and electrical characterization, we measure the average pressure drop of $13.6{\sim}125.4$ Pa/mm with the nonlinearity of 3.1 % for the flow-rates of $10{\sim}100{\mu}l/min$ in the fluidic line. The pressure drop per fluidic interconnection is measured as 0.19kPa. Experimentally, there are no significant differences in pressure drops between straight channels and elbow channels. The measured average electrical resistance is $0.26{\Omega}/mm$ in the electrical line. The electrical resistance per each electrical interconnection is measured as $0.64{\Omega}$. Mechanically, the maximum pressure, where the microelectrofluidic bench endures, reaches up to $115{\pm}11kPa$.

Study on the Application of Five Phases Theory to the Joints of the Limbs from the Viewpoint of Ha-Do Based on I-Ching (하도(河圖) 원리로 본 사지관절(四肢關節)의 오행(五行)배속 연구)

  • Kim, Byoung-Soo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.6
    • /
    • pp.1374-1377
    • /
    • 2008
  • The aim of this study is to explore the principle that the joints of the limbs belong to Five Phases in Korean medicine. According to the principle of I-Ching, Ha-Do provides the logic which could attach everything to Five Phases. Ha-Do is composed of the numbers from one through ten, and in order to explain the logic of Universe formation, it furnishes the method of transforming 'immateriality' into 'materiality'. If we apply formation theory of Ha-Do to the joints of the limbs, however, it could be understood that the trunk of body develops the appendages, which means Ha-Do suggests a logic that 'materiality' generates 'materiality' in this case. Therefore, it is not the Water but the Earth that occurs first in the appendages development in this theory, and the shoulder joints belong to the Earth. Following development should occur in order of Five Phases formation of Ha-Do ; that is to say, the elbow joints belong to the Water, the wrist joints belong to the Fire, the finger joints belong to the Wood, and the ends of fingers belong to the Metal.

A Stydy on the Ergonomic Sleeve Design by Body Surface Changes at Upper Extremity (상지체표변화에 따른 인간공학적 소매설계에 관한 연구)

  • 최해주
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.19 no.6
    • /
    • pp.911-923
    • /
    • 1995
  • The zone of expansion and contraction of arm surfaces was analyzed, the correlation between arm surface changes was studied, and ergonomic sleeve designs were presented in which the consideration of body surface changes is emphasized. Experiments were carried out which include 43 upper extremity segments, 21 motions and 35 female subjects. The major conclusions of the study are as follows : 1. As a sleeve drafting method, detailed measures should be applied on the base of the sensitivity of body surface changes. The range of arm surface changes can be divided into three zones : concentrated expansion zone, zone of little change, and contraction part. The maximum expansion zone was the upper part of elbow. 2. The correlations were higher in lengths than in circumferences. Arm lengths were mainly correlated with upper arms. The more detailed the arm surface was, the lower the correlations between surface changes were. So there was not a lot of relation between segment changes. Tendency of body surface changes depended on the anatomical structure of the upper extremity and the movements of arm muscles. 3. As an application of measures and ease, ergonomic sleeve designs weve presented in which arm surface changes were considered. Ergonomic sleeve designs are recommended for working clothes and sports wear.

  • PDF

Proposal for Pulse Diagnosis Positions (Chon-Kwan-Chuk) for Pulse Analyzer Based on Literature Review and Anthropometry (문헌고찰 및 실측에 근거한 맥진기 측정시 촌관척 정위에 대한 제안)

  • Kim, Hyun-Ho;Lee, Jeon;Kim, Ki-Wang;Kim, Jong-Yeol
    • The Journal of Korean Medicine
    • /
    • v.28 no.3 s.71
    • /
    • pp.13-22
    • /
    • 2007
  • Objectives : To obtain pulse information, oriental medical doctors usually use the three finger pulse diagnosis method. Although the diagnostic positions are very important, the exact positions are not known because of the uncertain conversion of measures of length (bun, chon, chuk) and misunderstanding of the related concepts of oriental medicine. In this study, we proposed relative positions for the detection of three pulses with a pulse analyzer. Methods : The proposal was made based mainly on several literature reviews, especially the original texts, and the examination of anthropometric characteristics of 78 individuals. Results : The Kwan is the spot where the radial pulse can be felt well near the eminent head of the radius at wrist, high bone. The position of Chon should be apart from Kwan by 6/10 distance between the high bone and wrist joint of each individual. Finally, the position of Chuk is apart from Kwan by 6.5/100 distance between the high bone and the elbow joint of each individual. Conclusions : Adapting those proposed positions for measuring three pulses can provide more consistent information to what an oriental doctor obtains than a pulse analyzer applied to other positions.

  • PDF

Effects of Constraint-Induced Movement Using Self-Efficacy Enhancing Strategies on the Upper Extremity Function of Chronic Hemiplegic Patients (자기효능증진전략을 이용한 건측억제유도운동이 편마비 환자의 상지기능에 미치는 효과)

  • Kang, Ji-Yeon
    • Journal of Korean Academy of Nursing
    • /
    • v.36 no.2
    • /
    • pp.403-414
    • /
    • 2006
  • Purpose: The purpose of this study was to investigate the effects of constraint-induced (CI) movement using self-efficacy on U/E function of chronic hemiplegic patients. CI movement discourages the use of the unaffected U/E, combined with intensive training of the affected U/E. Method: A non-equivalent pretest-posttest design was used. Study subjects were 40 hemiplegic patients conveniently selected from 2 different community health centers. The experimental subjects participated in the CI movement program for 6 hours daily over a period of two weeks. The exercises for affected U/E consisted of warming up, main exercise and ADL practice. To encourage the participants' behaviors self-efficacy enhancing strategies were used, which included performance accomplishment, vicarious experience, verbal persuasion and emotional arousal. Result: After 2 weeks of treatment, the grip power, pinch power, wrist flexion/extension, elbow flexion, and shoulder flexion/extension were significantly higher in the experimental subjects than in the control subjects. However, there was no significant difference in hand functions of the two groups. Conclusion: The above results show that the constraint-induced movement using self-efficacy could be an effective nursing intervention for improving U/E function of chronic hemiplegic patients. Long term studies are needed to determine the lasting effects of constraint-induced movement.

A Study on the Reduction Method of Heavy-weight floor impact sound and Plumbing noise in Decrepit Apartment houses (노후 아파트의 바닥충격음 및 급·배수 소음 저감방안에 관한 연구)

  • Joo, Moon Ki;Han, Myung Ho;Oh, Yang Ki
    • KIEAE Journal
    • /
    • v.9 no.2
    • /
    • pp.99-106
    • /
    • 2009
  • The noise in apartment buildings are major factor that determine the quality of indoor noise environment. Particularly, the noise from children's running footsteps and plumbing noise have caused the residents who live in decrepit apartment houses to uncomfortable environment. And as time go by, sound performance are getting worse according to the aging of the facilities. So this study deals with the plans to improve the sound performance of decrepit apartment house. To compare the noise reduction, we measured the heavy-weight impact sound level and plumbing noise level before and after changes the measurement conditions. As the results of measurements, the heavy-weight impact sound level were decreased when stiffness reinforcement were installed on slab. Especially the sound level were decreased 2.1-7.6dB in 50-80Hz of low frequency range. Instead of PVC pipe system, cast iron pipe and triple elbow drain pipe systems were installed. Noise level were decreased 15dB(A) in 250Hz. Noise level of pipe system's on the slab is less than under slab one. On the contrary water saving stool showed increasing the noise level.

Development of Wearable Robot for Elbow Motion Assistance of Elderly (노약자의 팔꿈치 거동 지원을 위한 착용형 로봇 개발)

  • Jang, Hye-Yoen;Han, Chang-Soo;Kim, Tae-Sik;Jang, Jae-Ho;Han, Jung-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.3
    • /
    • pp.141-146
    • /
    • 2008
  • The purpose of this study is to develop the algorithm which can control muscle power assist robot especially for elderly. Recently, wearable robots for power assistance are developed by many researchers, and its application fields are also variable such as for medical or military equipment. However, there are many technical barriers to develop the wearable robot. This study suggest a control method improving performance of a wearable robot system by using a EMG signal of major muscles and a force sensor signal as command signal of system. The result of the robot Prototype efficiency experiment, the case of Maximum Isometric motion it suggest 100% power of muscle, the man need only 66% of MVIC(Maximum Voluntary Isometric Contraction) to lift 5kg dumbbell without robot assist. However the man needs only 52% of MVIC to lift 5kg dumbbell with robot assist. Therefore 20% muscle power increased with robot assist. Also, we designed light weight robot mechanism that extract the command signal verified and drive the wanted motions.