• Title/Summary/Keyword: Elbow Tube

Search Result 17, Processing Time 0.021 seconds

Influence of Velocity on Pressure Drop of Flowing Ice Slurry in Elbow and its continued Inclined Tube (곡관과 연속된 경사관 내에서 유동하는 아이스슬러리의 압력손실에 미치는 유속의 영향)

  • Park Ki-Won;Kim Kyu-Mok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.635-641
    • /
    • 2005
  • This study experimented to understand the effects of transporting ice slurry through elbow and inclined tube. And at this experiment it used propylene glycol-water solution and a diameter of about 2mm ice particle. The experiments were carried out under various conditions, with velocity of water solution at the entry ranging from 1.0 to 3.5 w/s and elbows and inclined tubes of 4 kinds angle with $30^{\circ},\;45^{\circ},\;90^{\circ}\;and\;180^{\circ}$. The pressure drop between the tube entry and exit were measured. According to angle of bending, the highest pressure drop was measured at $30^{\circ}$ elbow and the lowest pressure drop was measured at $90^{\circ}$ elbow, and there are only a little differences of pressure drop between $45^{\circ}$ elbow and $180^{\circ}$ elbow. According to angle of inclined tube, the highest pressure drop was measured at $90^{\circ}$ inclined tube and the pressure drop at $45^{\circ},\;30^{\circ},\;180^{\circ}$ inclined tubes were lower successively. The lowest pressure drop in elbows and inclined tubes was measured at velocity of $2.0\~2.5$ m/s and concentration of $10\;wt\%$.

Evaluation of online video content related to reverse shoulder arthroplasty: a YouTube-based study

  • Mohamad Y. Fares;Jonathan Koa;Peter Boufadel;Jaspal Singh;Amar S. Vadhera;Joseph A. Abboud
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.2
    • /
    • pp.162-168
    • /
    • 2023
  • Background: Reverse shoulder arthroplasty (RSA) has evolved continuously over recent years, with expanded indications and better outcomes. YouTube is one of the most popular sources globally for health-related information available to patients. Evaluating the reliability of YouTube videos concerning RSA is important to ensure proper patient education. Methods: YouTube was queried for the term "reverse shoulder replacement." The first 50 videos were evaluated using three different scores: Journal of the American Medical Association (JAMA) benchmark criteria, the global quality score (GQS), and the reverse shoulder arthroplasty-specific score (RSAS). Multivariate linear regression analyses were conducted to determine the presence of a relationship between video characteristics and quality scores. Results: The average number of views was 64,645.78±264,160.9 per video, and the average number of likes was 414 per video. Mean JAMA, GQS, and RSAS scores were 2.32±0.64, 2.31±0.82, and 5.53±2.43, respectively. Academic centers uploaded the highest number of videos, and surgical techniques/approach videos was the most common video content. Videos with lecture content predicted higher JAMA scores whereas videos uploaded by industry predicted lower RSAS scores. Conclusions: Despite its massive popularity, YouTube videos provide a low quality of information on RSA. Introducing a new editorial review process or developing a new platform for patients' medical education may be necessary. Level of evidence: Not applicable.

Process Analysis of Elbow-shaped Tubes using a Mandrel (맨드렐을 이용한 엘보우 성형 공정해석)

  • Oh, I.Y.;Park, S.H.;Park, J.Y.;Lee, S.H.;Lee, E.Y.;Moon, Y.H.
    • Transactions of Materials Processing
    • /
    • v.26 no.1
    • /
    • pp.11-17
    • /
    • 2017
  • In this study, process analysis of elbow-shaped tubes using a mandrel has been performed. To reach the final shape within the dimensional tolerance, the process analysis has been performed at various processing parameters such as tube dimensions, the curved cutting surface and the radius of curvature. The area outside the boundary of the target shape was expressed as a quantitative index to analyze the formability. The validation experiments have also been performed in order to increase the reliability of the process analysis. For the processing of elbow-shaped tubes, it is preferable to make the angle of the portion where the punch touches the tube smaller than the opposite angle. And the convex cutting surface is advantageous due to the increased contacts between the punch and the tube ends during the bending process. Elbow tube having larger radius of curvature shows higher dimensional accuracy due to the relatively uniform strain distribution.

YouTube as a source of patient education information for elbow ulnar collateral ligament injuries: a quality control content analysis

  • Yu, Jonathan S;Manzi, Joseph E;Apostolakos, John M;Carr II, James B;Dines, Joshua S
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.2
    • /
    • pp.145-153
    • /
    • 2022
  • Background: While online orthopedic resources are becoming an increasingly popular avenue for patient education, videos on YouTube are not subject to peer review. The purpose of this cross-sectional study was to evaluate the quality of YouTube videos for patient education in ulnar collateral ligament (UCL) injuries of the elbow. Methods: A search of keywords for UCL injury was conducted through the YouTube search engine. Each video was categorized by source and content. Video quality, reliability, and accuracy were assessed by two independent raters using five metrics: (1) Journal of American Medical Association (JAMA) benchmark criteria (range 0-4) for video reliability; (2) modified DISCERN score (range 1-5) for video reliability; (3) Global Quality Score (GQS; range 1-5) for video quality; (4) ulnar collateral ligament-specific score (UCL-SS; range 0-16), a novel score for comprehensiveness of health information presented; and (5) accuracy score (AS; range 1-3) for accuracy. Results: Video content was comprised predominantly of disease-specific information (52%) and surgical technique (33%). The most common video sources were physician (42%) and commercial (23%). The mean JAMA score, modified DISCERN score, GQS, UCL-SS, and AS were 1.8, 2.4, 1.9, 5.3, and 2.7 respectively. Conclusions: Overall, YouTube is not a reliable or high-quality source for patients seeking information regarding UCL injuries, especially with videos uploaded by non-physician sources. The multiplicity of low quality, low reliability, and irrelevant videos can create a cumbersome and even inaccurate learning experience for patients.

The Importance of Corrosion Control and Protection Technology in the Refinery

  • Kim, Byong Mu;Oh, Sung Lyong
    • Corrosion Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.112-119
    • /
    • 2007
  • This paper presents the importance of corrosion control and protection technology with a real case study of heater tube rupture damaged by High temperature H2S-H2 corrosion in the refinery. The heater was operated at the Hydrocracking unit and the operation temperature and pressure was $340^{\circ}C$ and $18kg/cm^{3}$ respectively. Top side of the convection tube was thinned by high temperature hydrogen sulfide and hydrogen gas as a uniform corrosion and finally ruptured under operation pressure. Damaged area (Convection tube zone) was blocked by protection wall, so it was impossible to inspect with conventional nondestructive examination. Instead the elbow area which is out of the protection wall was inspected regularly to evaluate the corrosion rate of convection tube indirectly. However the operation temperature and the phase of the process stream was different between inside the chamber and outside the chamber. As a result, it caused severe corrosion to the horizontal convection tube inside the chamber comparing to the elbow outside the chamber. Finally convection tube was corroded more rapidly than the elbow and ruptured after 13 years operation. Because of the rupture, the heater was totally burned and the operation was stopped for 3 months until it has been reconstructed. To prevent this kind of corrosion problem and accident, corrosion control should be strengthened and protection technology should be improved.

A Study on the Characteristics of Multi-point Pilot Tube Flow-meter (다점 피토관 유량계의 특성에 관한 연구)

  • 임재명;윤복현;박경암
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.2 s.11
    • /
    • pp.35-43
    • /
    • 2001
  • The flow characteristics passing a multi-point Pitot tube flow-meter of diamond shape and the characteristics of flow coefficients of the flow-meter are experimentally studied by varying combination of upstream rectangular dual elbows. The results provide the flow coefficients, which show good stability and reliability within the Reynolds number range coveted here in this study, and which can be used to measure flow-rates in practice. The variation of dual elbows upstream can change the velocity field so much that the flow pattern might thwart the precise flow measurement using the multi-point Pitot tube. The strongest swirl is detected in the case of $90^{\circ}$ dual elbow combination of all. In addition, it is observed that flow separation remains unchanged and occurs at the same point irrespective of various upstream dual elbow combinations.

  • PDF

YouTube videos provide low-quality educational content about rotator cuff disease

  • Kunze, Kyle N.;Alter, Kevin H.;Cohn, Matthew R.;Vadhera, Amar S.;Verma, Nikhil N.;Yanke, Adam B.;Chahla, Jorge
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.3
    • /
    • pp.217-223
    • /
    • 2022
  • Background: YouTube has become a popular source of healthcare information in orthopedic surgery. Although quality-based studies of YouTube content have been performed for information concerning many orthopedic pathologies, the quality and accuracy of information on the rotator cuff have yet to be evaluated. The purpose of the current study was to evaluate the reliability and educational content of YouTube videos concerning the rotator cuff. Methods: YouTube was queried for the term "rotator cuff." The first 50 videos from this search were evaluated. Video reliability was assessed using the Journal of the American Medical Association (JAMA) benchmark criteria (range, 0-5). Educational content was assessed using the global quality score (GQS; range, 0-4) and the rotator cuff-specific score (RCSS; range, 0-22). Results: The mean number of views was 317,500.7±538,585.3. The mean JAMA, GQS, and RCSS scores were 2.7±2.0, 3.7±1.0, and 5.6±3.6, respectively. Non-surgical intervention content was independently associated with a lower GQS (β=-2.19, p=0.019). Disease-specific video content (β=4.01, p=0.045) was the only independent predictor of RCSS. Conclusions: The overall quality and educational content of YouTube videos concerned with the rotator cuff were low. Physicians should caution patients in using such videos as resources for decision-making and should counsel them appropriately.

Failure Analysis of Austenitic Stainless Steel Pipe (오스테나이트계 스테인레스 강관에서의 손상해석에 관한 연구)

  • 이상율;이종오;이주석;조경식;조종춘;이보영
    • Journal of Welding and Joining
    • /
    • v.11 no.1
    • /
    • pp.21-32
    • /
    • 1993
  • A cracking failure of a austenitic stainless steel elbow in a naphtha cracking line in a petrochenmical plant occurred, resulting in leakage of organic compound flowing inside the elbow. Due to the failure, emergency shutdown of the plant was enforced to repair the troubled part of the line. The repair cost as well as production loss during the unscheduled plant shutdown has cost the company a great amount of financial loss. In this studies, a failure analysis of the cracked elbow was performed using NDT, chemical analysis, microstructural analysis including optical microscopy as well as scanning electron microscopy with EPMA, mechanical testings such as tensile testing, hardness testing and Charphy impact test fractography. The results indicated that several problems such as a welding defect and presence of a detrimental phase which was found to be relate to improper postforming heat treatment process was identified and the failure was concluded to be due to a low temperature embrittlement of the defect-containing elbows.

  • PDF

Conjugate Heat Transfer Analysis of an Ethylene Furnace (에틸렌 반응로에 대한 복합 열전달 해석)

  • Ahn, Joon;Park, Jin Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.515-519
    • /
    • 2015
  • Conjugate heat transfer analysis for an ethylene furnace was carried out based on numerical simulation. Detailed distributions of velocity vectors, chemical species, and temperature inside the furnace are presented and discussed. Von Mises stress and heat flux at the tube surface were also evaluated to elucidate mechanisms regarding failure of the tube. Maximum stress was found at the upstream elbow of the tube, which did not coincide with the location of maximum heat flux. This implies that thermal stress at a steady state would not be a dominant component of the stress. Degradation of the material, as well as the system arrangement, should be considered in order to accurately predict the lifetime of the tube material in the furnace.

Steady and unsteady flow computation in an elbow draft tube with experimental validation

  • Vu, Thi C.;Devals, Christophe;Zhang, Ying;Nennemann, Bernd;Guibault, Francois
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.85-96
    • /
    • 2011
  • Steady state computations are routinely used by design engineers to evaluate and compare losses in hydraulic components. In the case of the draft tube diffuser, however, experiments have shown that while a significant number of operating conditions can adequately be evaluated using steady state computations, a few operating conditions require unsteady simulations to accurately evaluate losses. This paper presents a study that assesses the predictive capacity of a combination of steady and unsteady RANS numerical computations to predict draft tube losses over the complete range of operation of a Francis turbine. For the prediction of the draft tube performance using k-${\varepsilon}$ turbulence model, a methodology has been proposed to average global performance indicators of steady flow computations such as the pressure recovery factor over an adequate number of periods to obtain correct results. The methodology will be validated using two distinct flow solvers, CFX and OpenFOAM, and through a systematic comparison with experimental results obtained on the FLINDT model draft tube.