• Title/Summary/Keyword: Elastic-Plastic Toughness

Search Result 74, Processing Time 0.028 seconds

Elastic Plastic Finite Element Calculation of Standard Fracture Toughness Specimens (표준 파괴인성시험편에 대한 탄소성 유한요소해석)

  • 박용걸
    • Computational Structural Engineering
    • /
    • v.7 no.4
    • /
    • pp.113-118
    • /
    • 1994
  • The purpose of this study is elastic plastic finite element analysis for standard fracture toughness specimens. The principles of elastic-plastic fracture mechanics are shortly summarized and the special requirements for computational tools are derived. Possibilities to model the crack tip singularities are mentioned. The relevant fracture parameters like J-Integral and COD and their correlation are evaluated from elastic plastic finite element calculations of standard fracture toughnes specimens. The size and form of the plastic zone are shown. The comparion between experiment and caculation is discussed as well as the application of the limit load analysis.

  • PDF

The Evaluation for Elastic-Plastic Fracture Toughness in a Reactor Pressure Vessel Steel(SA508-3) (원자력 압력용기강(SA508-3)의 탄소성 파괴인성 평가)

  • 오세욱;윤한기;임만배
    • Journal of Ocean Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.91-102
    • /
    • 1993
  • The elastic-plastic fracture thoughness J sub(IC) of Nuclear Reactor Vessel Steel(SA 508-3) which has high toughness was discussed at temperatures RT, $-20^{\circ}C$, $200^{\circ}C$ and 1/2/CT specimen was used for this study. Especially the two methods recommended in ASTM and JSME were compared. It was difficult to find J sub(IC) by ASTM R-curve method with the specimen used for this research, while JSME R-curve method yielded good result. The stretched zone width menthod gave slightly larger J sub(IC) values than those by the R-curve method for SA 508-3 steel.

  • PDF

Evaluation of Elastic-Plastic Fracture Toughness of Aged AISI 316 Steel Using DC-electric Potential Method (직류전위차법을 이용한 AISI 316강 시효재의 탄소성 파괴인성 평가)

  • Lim, Jae-Kyoo;Chang, Jin-Sang;Lino, Y.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.3
    • /
    • pp.519-527
    • /
    • 1997
  • AISI 316 steel has been used extensively for heater and boiler tube of the structural plants such as power, chemical and petroleum plants under severe operating conditions. Usually, material degradation due to microcrack or precipitation of carbides and segregation of impurity elements, is occured by damage accumulated for long-term service at high temperature in this material. In this study, the effect of aging time on fracture toughness was investigated to evaluate the measurement of material degradation. The elastic-plastic fracture toughness behaviour of AISI 316 steel pipe aged at $550^{\circ}C$for 1h-10000h (the aged material) was characterized using the single specimen J-R curve technique and eletric potential drop method at normal loading rate(load-line displacement speed of 0.2mm/min) in room temperature and air environment. The fracture toughness data from above experiments is compared with the $J_{in}$ obtained from predicted values of crack initiation point using potential drop method.

Prediction of Elastic-Plastic Fracture Toughness for Metallic Material using Finite Element Method (유한요소법에 의한 금속재료의 탄소성파괴인성 예측)

  • Sun Dong-Ju;Park Myung-kyun;Bahk Sae-Man;Choi Young-Taek
    • Journal of the Korean Institute of Gas
    • /
    • v.1 no.1
    • /
    • pp.95-100
    • /
    • 1997
  • In order to predict the elastic-plastic fracture toughness for metallic materials, Finite Element Method(FEM) was used for analysis of compact tension specimen. ASTM E399 test procedure was adopted for simulation of FEM. The Load-Crack Mouth Opening Displacement curve obtained from this analysis was used to detect the crack initiation point and determine the elastic-plastic fracture toughness $J_{IC}$. In order to prove the results, they were compared with the results from previous experiments and they agree with experimental results.

  • PDF

Evaluation by modified offset method on J-R curve with negative crack growth (부균열을 가진 J-R곡선의 수정옾셋방법에 의한 평가)

  • 안광주;최재강
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.3
    • /
    • pp.45-51
    • /
    • 1997
  • To evaluate the elastic-plastic fracture toughness by this modified offset method, the origin of J-R curve is set with drawing the blunting line on the maximum point of the negative crack growth and R curve is modified by adding the blunting factor of the experimented point on the R curve. The elastic-plastic fracture toughness $J_{IC]$ of A5083-H112 material by the modified offset method we 44kN/m on the smooth CT specimens.

  • PDF

A method of Determination of Fracture Toughness of Reactor Pressure Vessel Steel by J Integral (J적분을 이용한 원자력 압력용기강의 파괴인성치의 결정)

  • 오세욱;임만배;김진선
    • Journal of Ocean Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.111-119
    • /
    • 1995
  • The elastic-plastic fracture toughness($J_{IC}$) and fracture resistance (J-R curve) of SA508-3 alloy steel used for nuclear reactor pressure vessel are investigated by using CT-type specimens. Fracture toughness tests are conducted by unloading compliance method and multiple specimen method at room temperature, -2$0^{\circ}C$ and 20$0^{\circ}C$. The apparent negative crack growth phenomenon which usually arises in partial unloading compliance test is well known. The negative crack growth phenomenon in determining J sub(IC) or J-R cure from partial unloading compliance experiments may be eliminated by the offset technique. In this study, the evaluation of $J_{IC}$ multiple specimen method recommended by the JSME gives the most reliable results by using half-size CT(similar-type) specimens.

  • PDF

Effects of Accelerated Iso-Thermal Aging on Elastic-Plastic Fracture Toughness and Fracture Resistance Curve by Unloading Compliance Method in SA533B Low Alloy Steel (제하 컴플라이언스법에 의한 SA533B강의 $J_1C$ 및 J-R 곡선에 미치는 열시효 영향)

  • 윤한기;차귀준
    • Journal of Ocean Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.157-165
    • /
    • 1994
  • Effect of an accelerated iso-thermal aging (375 degree C x 66days, 375 degree C x 200days) on elastic-plastic fracture resistance curve were examined in SA533B low alloy steel. Fracture toughness test are conducted by unloading compliance method at room temperature. But the apparent negative crack growth phenomenon, usually arise in partial unloading compliance test. The phenomenon of negative crack growth may be eliminated by the offset technique. There is no effect of aging on J sub(IC) and dJ/da in iso-thermal aged (375 degree C x 66 days) specimen, but there is very little effect in iso-thermal aged (375 degree C x 200 days) specimen.

  • PDF

A study on the fracture toughness degradation in cryogenic structural material using single-specimen method (단일 시험편법에 의한 극저온용 구조재료의 파괴인성 저하에 관한 연구)

  • Kwon, Il-hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.2
    • /
    • pp.343-351
    • /
    • 1998
  • This paper was investigated degradation of the fracture toughness caused by sensitizing heat-treatment of the cryogenic structural material JN1 base metal using unloading compliance method reported as useful a method in evaluating the elastic-plastic fracture toughness at cryogenic temperature. The specimens used in this paper were 20% side-grooved 0.5T-CT specimens which were machined in the JN1 base metal. Also, to investigate cryogenic fracture toughness of the fusion line region in the JN1 GTA weldments, it was also used 20% side-grooved 0.5T-CT specimens that was machined fusion line to located in the middle of the specimen. The cryogenic fracture toughness values of the JN1 base metal were significantly decreased with increasing the time and temperature of the heat treatment. The fracture toughness value obtained from the fusion line specimen was invalid, but it was lower value than that of the JN1 base metal. Especially, this value was approximately equal with that obtained from the JN1 650.deg. C-5h heat-treated material.

A study on the fatigue crack growth of mild steel weldments using flux cored wire $CO_2$ welding (국산 Flux-Cored Wire를 이용한 반자동용접이음새에서의 피로파괴 특성)

  • 엄동석
    • Journal of Welding and Joining
    • /
    • v.7 no.1
    • /
    • pp.42-50
    • /
    • 1989
  • The application of fracture mechanics is being increased gradually to assess the safety of welded structures containing crack. Fatigue crack propagation behavior and elastic-plastic fracture toughness J$_{IC}$ of home made flux cored wire(1.22mm) CO$_{2}$ weldments was discussed. Especially fatigue crack propagation test was carried out by .DELTA.K control instead of load control and elastic-plastic fracture toughness J$_{IC}$ was obtained by ASTM-R curve method on C.T.specimen in transverse direction of weldments. The results obtained are as follows; (1) Weld metal presented an almost complete similarity to base metal on fatigue crack propagation rate in transverse direction. (2) Weld metal was more than base metal on J$_{IC}$ value in transverse direction. (3) F.C.W. CO$_{2}$ weldments had an excellent characteristic of fatigue crack propagation rate and J$_{IC}$ in less than 50kg/mm$^{2}$ steel grade, this would result from that weld metal had good static strength.trength.

  • PDF

Determination of CTOD & CTOA Curve for Structural Steel Hot-Rolled Thin Plates (일반 구조용강 열간압연 박판에 대한 CTOD와 CTOA 곡선 결정)

  • 이계승;이억섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.729-732
    • /
    • 2003
  • The K-R design curve is an engineering method of linear-elastic fracture analysis under plane-stress loading conditions. By the way, linear-elastic fracture mechanics (LEFM) is valid only as long as nonlinear material deformation is confined to a small region surrounding the crack tip. Like general steels, it is virtually impossible to characterize the fracture behavior with LEFM, in many materials. Critical values of J contour integral or crack tip opening displacement (CTOD) give nearly size independent measures of fracture toughness, even for relatively large amounts of crack tip plasticity. Furthermore, the crack tip opening displacement is the only parameter that can be directly measured in the fracture test. On the other. the crack tip opening angle (CTOA) test is similar to CTOD experimentally. Moreover, the test is easier to measure the fracture toughness than other method. The shape of the CTOA curve depends on material fracture behavior and, on the opening configuration of the cracked structure. CTOA parameter describes crack tip conditions in elastic-plastic materials, and it can be used as a fracture criterion effectively. In this paper, CTOA test is performed for steel JS-SS400 hot-rolled thin plates under plane-stress loading conditions. Special experimental apparatuses are used to prevent specimens from buckling and to measure crack tip opening angle for thin compact tension (CT) specimens.

  • PDF