• Title/Summary/Keyword: Ejection Rate

Search Result 138, Processing Time 0.025 seconds

A Study on Misdiagnosis Rates of Ejection Fraction Associated with Cardiac Computed Tomography: Suggestions and Correction for Improvement (심장 전산화단층촬영을 이용한 박출계수 산출 시 박출계수의 보정을 통한 오진율 개선에 관한 연구)

  • Na, Sa-Ra;Jeong, Mi-Ae
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.2
    • /
    • pp.437-444
    • /
    • 2021
  • The aim of this study was to compare the cardiac CT and cardiac MRI in calculating and correcting the left ventricle ejection fraction by analyzing the physical and temporal resolution for reducing the misdiagnosis rate. One hundred thirty-eight patients with aortic value regurgitation who underwent both cardiac CT and cardiac MRI were analyzed. Left ventricle ejection fractions calculated from each exam were corrected based on the physical and temporal resolution differences and the reliability test evaluated whether the misdiagnosis rate of cardiac CT was improved after the correction. As a result of the study, the misdiagnosis rate of cardiac CT ejection fraction before correcting the difference in physical and temporal resolution was 38.4%(53 persons). In addition, it can be seen that the corrected cardiac CT ejection fraction confirmed in the Bland-Altman plot was highly consistent with the ejection fraction of cardiac MRI. In conclusion, as the cardiac CT is less well suited for measuring ejection fraction, physical characteristics and the time resolution correction using cardiac MRI is needed and the misdiagnosis rate after correction decreased to 14.5%(20 persons). Therefore, this study appears more appropriate for better prediction of ejection fraction and clinical utility.

Effect of Korea Red Ginseng on the Symptoms and Hemodynamics in Healthy Elders

  • Jin En-Yuan;Li Ya-Jun;Yang Lian-Xing;Jin Ming;Wei Yu-Lin;Nam Ki Yeul
    • Proceedings of the Ginseng society Conference
    • /
    • 2002.10a
    • /
    • pp.27-34
    • /
    • 2002
  • Clinical study on hemodynamics of healthy elders before and after tread mill. Using doubleblind, placebo-controlled study design. Seventy-five 50-70 years old volunteers without organic disease were divided into two groups, Ginseng group and control group. Each subject was received 3 g Korea Red Ginseng (KRG) capsules or placebo per day for 4 weeks. Before and after administration 4 weeks, the symptoms were asked and hemodynamics parameter such as pump function, systolic function, preload and afterload were recorded before and after tread mill 1,5, 10 minutes by the method of thoracic impedance cardiograph. The result showed that Ginseng could improve quality of life, had obvious effect of increasing PEP (pre-ejection period), PEP/LVET (pre-ejection period/left ventricular ejection period), PCWP (wedged pressure pulmonary capillary). The change rate of HR (heart rate), SV (stroke volume) in KRG group were much lowered, while EF (ejection fraction), LVET (left ventricular ejection period), LVEDP (left ventricular end diastolic pressure) was recovered much quickly. The circulation showed Ginseng could improve the quality of life though its promoting circulation function which are increasing both the systolic function and the preload.

  • PDF

Influence of Water Temperature and Salinity on Sand Ejection of Manila Clam, Ruditapes philippinarum

  • Kang, Kyoung-Ho;Kim, Jae-Min;Kim, Young-Hun
    • The Korean Journal of Malacology
    • /
    • v.21 no.1
    • /
    • pp.13-17
    • /
    • 2005
  • In this study, the influence of water temperature and salinity on sand ejection of Manila clams, Ruditapes philippinarum, was investigated. The result showed that, under different water temperature, the highest quantity of sand ejection was at $20^{\circ}C$, the value of which was 0.091 g, while the smallest one was only 0.058 g at 0$^{\circ}C$. The highest releasing rate, 95.79%, could be seen in $20^{\circ}C$ group, while $0^{\circ}C$ group was the lowest one, 85.29%. Under different salinity, 30 psu group had the highest value, 0.057 g, and 0 psu (freshwater) group was the lowest one, only 0.026 g. At the same time, the highest releasing rate appeared at 25 psu, which was 90%. 0 psu group was the lowest one in releasing rate, 60.47%. According to these results, we recommend that the clams should be placed into the clear seawater with about 25 psu of salinity at near $20^{\circ}C$ to let the clams perform the self-depuration. Better quality of clams containing less impurity in the aquaculture and commerce could be obtained from this pre-treatment.

  • PDF

Quantitative Evaluation of the First Order Creatine-Kinase Reaction Rate Constant in in vivo Shunted Ovine Heart Treated with Oxandrolone Using Magnetization Transfer 31P Magnetic Resonance Spectroscopy (MT-31P-MRS) and 1 H/31P Double-Tuned Surface Coil: a Preliminary Study

  • Thapa, Bijaya;Dahl, Marjanna;Kholmovski, Eugene;Burch, Phillip;Frank, Deborah;Jeong, Eun-Kee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.26-36
    • /
    • 2018
  • Purpose: Children born with single ventricle physiology demonstrate poor growth rate and suffer from malnutrition, which lead to increased morbidity and mortality in this population. We assume that an anabolic steroid, oxandrolone, will promote growth in these infants by improving myocardial energy utilization. The purpose of this paper is to study the efficacy of oxandrolone on myocardial energy consumption in these infants. Materials and Methods: We modeled single ventricle physiology in a lamb by prenatally shunting the aorta to the pulmonary artery and then postnatally, we monitored cardiac energy utilization by quantitatively measuring the first order reaction rate constant, $k_f$ of the creatine-kinase reaction in the heart using magnetization transfer $^{31}P$ magnetic resonance spectroscopy, home built $^1H/^{31}P$ transmit/receive double tuned coil, and transmit/receive switch. We also performed cine MRI to study the structure and dynamic function of the myocardium and the left ventricular chamber. The spectroscopy data were processed using home-developed python software, while cine data were analyzed using Argus software. Results: We quantitatively measured both the first order reaction rate constant and ejection fraction in the control, shunted, and the oxandrolone-treated lambs. Both $k_f$ and ejection fraction were found to be more significantly reduced in the shunted lambs compared to the control lambs, and they are increased in oxandrolone-treated lambs. Conclusion: Some improvement was observed in both the first order reaction rate constant and ejection fraction for the lamb treated with oxandrolone in our preliminary study.

Flow Analysis in a Rotating Container with Axial Injection and Radial Ejection (축방향 유입과 반경방향 유출이 있는 회전용기 내의 유동해석)

  • Park, Jun-Sang;Sohn, Jin-Gug
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.1
    • /
    • pp.49-54
    • /
    • 2011
  • An investigation has been made of a viscous incompressible flow in a circular cylindrical tank. The flow is driven by the spinning bottom disk of tank together with/without central injection and radial uniform-ejection through the sidewall. Numerical solutions of steady and unsteady flows to 3-dimensional Navier-Stokes equation were obtained for several cases of injection strength. In a moderate flow rate of injection, the mass transfer occurs through the boundary layers but, as the flow rate increases, the inner region far from the container walls takes part in mass transfer.

Effect of Outer Nozzle Ejection Angle on Jet Structure issuing from Supersonic Dual Coaxial Nozzle (초음속 동축 제트의 구조에 미치는 외부노즐 분사각의 영향)

  • Baek, Seung-Cheol;Kwon, Soo-Young;Joo, Seong-Yeol;Kwon, Soon-Bum
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.426-431
    • /
    • 2001
  • This paper experimentally investigates the characteristics of dual coaxial jet issuing from inner supersonic nozzle and four kinds of outer converging nozzle of 40, 50, $60^{\circ}$ and $70^{\circ}$ in outer ejection angle. The pressure ratio of the stagnation to the exit ambient pressures in the inner supersonic nozzle of constant expansion rate is 7.5, which is corresponded to the condition of a slightly underexpanded, and that of outer nozzle is 4.0. Flow visualizations by using of shadowgraph method, impact pressure and centerline static pressure measurements are presented. It is found that the jet structure is changed significantly by the variation of outer nozzle ejection angle. Impact pressure level is lower and undulation of static pressure is higher, as the injection angle of outer jet increases.

  • PDF

Numerical Study on Bubble Growth and Droplet Ejection in a Bubble Inkjet Printer (버블 잉크젯에서의 기포성장 및 액적분사에 관한 수치적 연구)

  • Suh, Young-Ho;Son, Gi-Hun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.11 s.254
    • /
    • pp.1107-1116
    • /
    • 2006
  • The droplet ejection process driven by an evaporating bubble in a thermal inkjet printhead is investigated by numerically solving the conservation equations for mass, momentum and energy. The phase interfaces are tracked by a level set method which is modified to include the effect of phase change at the interface and extended for multiphase flows with irregular solid boundaries. The compressibility effect of a bubble is also included in the analysis to appropriately describe the bubble expansion behaviour associated with the high pressure caused by bubble nucleation. The whole process of bubble growth and collapse as well as droplet ejection during thermal inkjet printing is simulated without employing a simplified semi-empirical bubble growth model. Based on the numerical results, the jet breaking and droplet formation behaviour is observed to depend strongly on the bubble growth and collapse pattern. Also, the effects of liquid viscosity, surface tension and nozzle geometry are quantified from the calculated bubble growth rate and ink droplet ejection distance.

Cardiac Response to Head-Out Water Immersion in Man

  • Choi, Jang-Kyu;Park, Won-Kun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.4 no.3
    • /
    • pp.253-261
    • /
    • 2000
  • Head-out water immersion induces marked increase in the cardiac stroke volume. The present study was undertaken to characterize the stroke volume change by analyzing the aortic blood flow and left ventricular systolic time intervals. Ten men rested on a siting position in the air and in the water at $34.5^{circ}C$ for 30 min each. Their stroke volume, heart rate, ventricular systolic time intervals, and aortic blood flow indices were assessed by impedance cardiography. During immersion, the stroke volume increased 56%, with a slight (4%) decrease in heart rate, thus cardiac output increased ${\sim}50%.$ The slight increase in R-R interval was due to an equivalent increase in the systolic and diastolic time intervals. The ventricular ejection time was 20% increased, and this was mainly due to a decrease in pre-ejection period (28%). The mean arterial pressure increased 5 mmHg, indicating that the cardiac afterload was slightly elevated by immersion. The left ventricular end-diastolic volume index increased 24%, indicating that the cardiac preload was markedly elevated during immersion. The mean velocity and the indices of peak velocity and peak acceleration of aortic blood flow were all increased by ${\sim}30%,$ indicating that the left ventricular contractile force was enhanced by immersion. These results suggest that the increase in stroke volume during immersion is characterized by an increase in ventricular ejection time and aortic blood flow velocity, which may be primarily attributed to the increased cardiac preload and the muscle length-dependent increase in myocardial contractile force.

  • PDF

Wear Characteristics for Rod and Nozzle of Jetting Dispenser Driven by Dual Piezoelectric Actuators Under High Frequency with Phosphor-containing Liquid (형광체 함유 용액 고속 토출 조건에서의 듀얼 압전 디스펜서 공이와 노즐의 마모 특성 평가)

  • Ha, Myeong-Woo;Lee, Kwang-Hee;An, Jun-Wook;Lee, Chul-Hee
    • Tribology and Lubricants
    • /
    • v.33 no.2
    • /
    • pp.52-58
    • /
    • 2017
  • An ultra-high precise ejection process is essential in a dispensing system for fabricating various precision parts such as a semiconductor, LED, and camera module. The size of such parts has been decreasing, which implies that a precise ejecting technique is required. A phosphor-containing liquid is ejected via a dispenser using dual piezoelectric actuators that are used for generating a high-speed dispensing mechanism. The rod and nozzle continuously contact in high speed to eject the liquid. However, the high-strength filler or phosphor in the liquid causes wear on the surfaces of the rod and nozzle during the dispensing process. As a result, the ejection reliability decreases as the wear on the surfaces increases. Therefore, it is necessary to estimate the wear characteristics of the rod and nozzle via an experiment and FE analysis. Reliability rests up to 1,000 cycles are conducted under relatively severe conditions. The flow rate and surfaces roughness of the rod and nozzle are measured in each ejection cycle. The surface images and wear volume are obtained before and after the tests and the ejection reliability is confirmed by measuring the flow rate of the liquid. The experimental results show that the ejection reliability is maintained up to 1,000k cycles; these results are validated by the simulation results.

Effect of Aromatherapy Massage on the Mood, the Milk ejection Reflex, and the Immunoglobulin A of the Breast Milk of Mothers with a Cesarean Section Delivery (향요법마사지가 제왕절개술 산모의 기분, 유즙사출반사, 유즙 면역글로불린A에 미치는 효과)

  • Lee, Seong-Hui
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.5
    • /
    • pp.1357-1367
    • /
    • 2000
  • The purpose of this quasi-experimental study was to explore the effect of aromatherapy massage on the mood, the milk ejection reflex, and the immunoglobulin A of the breast milk of mothers who gave birth through a Cesarean section delivery. Twenty mothers who had Cesarean section were selected as an experimental group, and twenty-two were in the control group. Lavander and Rosemary oil mixed with Jojova carrier oil was used to massage the back, both axillar and breasts. Aromatherapy massage was done once a day for 20 minutes by the researcher. Each session consisted of 4 minutes for warm-up, 14 minutes for massage and 2 minutes for closure. The levels of IgA within the breast milk was analyzed by an immunoturbidimeter assay (Cobas INTEGRA, Roche, Swiss) before and after aromatherapy massage. Mood and milk ejection reflex were measured by self-reports at the same time. The data were analyzed using SPSS 7.5 and the hypotheses were tested by ANCOVA and the Pearson coefficient correlation. The results were as follows : 1) Score of mood increased significantly after the use of aromatherapy massage. 2) Score of milk ejection reflex increased significantly after the use of aromatherapy massage. 3) Level of IgA of breast milk did not change significantly after the use of aromatherapy massage.4) After the use of aromatherapy massage, there wasn't any correlation among mood, milk ejection reflex, and level of IgA of breast milk. In conclusion, the results suggest that aromatherapy massage is an effective nursing intervention to enhance the mood and the milk ejection reflex and to increase the rate of breastfeeding in the breastfeeding mothers under stresses like a Cesarean section.

  • PDF