• Title/Summary/Keyword: Eight-parallel

Search Result 122, Processing Time 0.027 seconds

Design and Operation Characteristics of 2.4MJ Pulse Power System for Electrothermal-Chemical(ETC) Propulsion(I) (전열화학추진용 2.4MJ 펄스파워전원의 설계와 동작특성(I))

  • Jin, Y.S.;Lee, H.S.;Kim, J.S.;Cho, J.H.;Lim, G.H.;Kim, J.S.;Chu, J.H.;Jung, J.W.;Hwang, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1868-1870
    • /
    • 2000
  • As a drive for an ETC (Electro-thermal Chemical) launcher, a large pulse power system of a 2.4MJ energy storage was designed, constructed and tested. The overall power system consists of eight capacitive 300kJ energy storage banks. In this paper we describe the design features, setup and operation test result of the 300kJ pulsed power module. Each capacitor bank of the 300kJ module consists of six 22kV 50kJ capacitors. A triggered vacuum switch (TVS-43) was adopted as the main pulse switch. Crowbar diode circuits, variable multi-tap inductors and energy dumping systems are connected to each high power capacitor bank via bus-bars and coaxial cables. A parallel crowbar diode stack is fabricated in coaxial structure with two series 13.5kV, 60kA avalanche diodes. The main design parameters of the 300kJ module are a maximum current of 180kA and a pulse width of 0.5 - 3ms. The electrical performances of each component and current output variations into resistive loads have been investigated.

  • PDF

Embedding a Mesh into a Crossed Cube (메쉬의 교차큐브에 대한 임베딩)

  • Kim, Sook-Yeon
    • The KIPS Transactions:PartA
    • /
    • v.15A no.6
    • /
    • pp.301-308
    • /
    • 2008
  • The crossed cube has received great attention because it has equal or superior properties to the hypercube that is widely known as a versatile parallel processing system. It has been known that a mesh of size $2{\times}2^m$ can be embedded into a crossed cube with dilation 1 and expansion 1 and a mesh of size $4{\times}2^m$ with dilation 1 and expansion 2. However, as we know, it has been a conjecture that a mesh with more than eight rows and columns can be embedded into a crossed cube with dilation 1. In this paper, we show that a mesh of size $2^n{\times}2^m$ can be embedded into a crossed cube with dilation 1 and expansion $2^{n-1}$ where $n{\geq}1$ and $m{\geq}3$.

Type of tooth movement during en masse retraction of the maxillary anterior teeth using labial versus lingual biocreative therapy in adults: A randomized clinical trial

  • Sadek, Mais M.;Sabet, Noha E.;Hassan, Islam T.
    • The korean journal of orthodontics
    • /
    • v.49 no.6
    • /
    • pp.381-392
    • /
    • 2019
  • Objective: The objective of this two-arm parallel trial was to compare the type of tooth movement during en masse retraction of the maxillary anterior teeth using labial versus lingual biocreative therapy. Methods: Twenty-eight subjects were randomized in a 1 : 1 ratio to either the labial or lingual group. En masse anterior retraction was performed using labial biocreative therapy in group A and lingual biocreative therapy in group B. Cone beam computed tomography scans were taken before and after retraction and the primary outcome was the type of tooth movement during anterior retraction. Data were analyzed using paired t-tests for comparisons within each group and independent-sample t-test for comparison of the mean treatment changes between the two groups. Results: Significant differences were found between the two groups in relation to the type of tooth movement (labiolingual inclination of the central incisor; mean difference, $5.85{\pm}1.85^{\circ}$). The canine showed significant distal tipping in the lingual group (mean difference, $6.98{\pm}1.25^{\circ}$). The canine was significantly more intruded in the lingual group (mean difference, $1.67{\pm}0.49mm$). Good anchorage control and significant soft tissue changes occurred in both groups. No serious adverse effects were detected. Conclusions: With a 10-mm retraction hook, the labial biocreative technique with the reverse curve overlay provided anterior retraction with good torque control, while in the lingual group, anterior retraction occurred with controlled tipping movement with significant distal tipping and intrusion of the canine (trial registration: The trial was registered at ClinicalTrials.gov [NCT03239275]).

Wireless Energy Supply for a MAV Propulsion System

  • Shimane, Eri;Komatsu, Shuhei;Komaru, Takashi;Komurasaki, Kimiya;Arakawa, Yoshihiro
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.862-865
    • /
    • 2008
  • Wireless energy supply for an MAV propulsion system using microwave was developed. This system consists of three sub system; the transmitter system, the rectenna system, and the tracking system. In the transmitter system five horn antennas were used as the antenna elements for the phased array system and both the beam divergence and steering angle was about 9deg. Eight rectennas were arrayed in parallel to obtain enough power to drive the electric motor on the MAV(the voltage was 250mV and the current was 6.8mA) in rectenna system. In tracking system two units of antenna system with leaf pattern which received the linearly-polarized wave despite the MAV yaw angle were set in each axis(x, y) for tracking an MAV in a 2-Dimentional space. And three output voltages $V_{com},\;V_1$ and $V_2$ were loaded in the PC to detect if the distance between transmitter and receiver was not constant. Finally when the microwave beam was steered by the phased array system the output voltage from rectenna was measured at 62cm while the MAV circled around above the transmitter system.

  • PDF

Success rate of nitrous oxide-oxygen procedural sedation in dental patients: systematic review and meta-analysis

  • Rossit, Marco;Gil-Manich, Victor;Ribera-Uribe, Jose Manuel
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.21 no.6
    • /
    • pp.527-545
    • /
    • 2021
  • The aim of this systematic review was to determine the success rate of nitrous oxide-oxygen procedural sedation (NOIS) in dentistry. A systematic digital search was conducted for publications or reports of randomized controlled trials evaluating the clinical performance of NOIS. Abstracts of research papers were screened for suitability, and full-text articles were obtained for those who met the inclusion and exclusion criteria accordingly. The quality of the studies was assessed using the revised Cochrane risk-of-bias tool (RoB 2). A total of 19 articles (eight randomized clinical trials with parallel intervention groups and 11 crossover trials), published between May 1988 and August 2019, were finally selected for this review. The studies followed 1293 patients reporting NOIS success rates, with a cumulative mean value of 94.9% (95% CI: 88.8-98.9%). Thirteen trials were conducted on pediatric populations (1098 patients), and the remaining six were conducted on adults (195 patients), with cumulative efficacy rates of 91.9% (95% CI: 82.5-98.1%) and 99.9% (95% CI: 97.7-100.0%), respectively. The difference was statistically significant (P = 0.002). Completion of treatment and Section IV of the Houpt scale were the most used efficacy criteria. Within the limitations of this systematic review, the present study provides important information on the efficacy rate of NOIS. However, further well-designed and well-documented clinical trials are required and there is a need to develop guidelines for standardization of criteria and definition of success in procedural sedation. Currently, completion of treatment is the most used parameter in clinical practice, though many others also do exist at the same time. To maximize NOIS efficacy, clinicians should strictly consider appropriate indications for the procedure.

Protocatechuic acid impacts rotator cuff healing and reduces fatty degeneration in a chronic rotator cuff tear model in rats

  • Seo, Su-Jung;Park, Jae-Young;Park, Hyoung-Jin;Hwang, Jung-Taek
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.1
    • /
    • pp.5-14
    • /
    • 2022
  • Background: The purpose of this study was to verify the effect of protocatechuic acid (PCA) on tendon healing and fatty degeneration in a chronic rotator cuff model. Methods: Twenty-eight Sprague-Dawley male rats were randomly allocated into two groups: Saline+repair (SR) and PCA+repair (PR). The right shoulder was used for experimental interventions, and the left served as a control. PCA (30 mg/kg/day) was administered intraperitoneally at the site of infraspinatus tendon detachment in rats in the PR group, and the same volume of saline was administered to the same site in the SR group. The torn tendon was repaired 4 weeks after infraspinatus detachment. Four weeks after repair, hematoxylin and eosin (H&E), S100, and CD68 stains were performed to evaluate the degree of fatty degeneration and H&E and Masson trichrome stains were performed to assess tendon healing. Superoxide dismutase (SOD) was measured to test the efficacy of PCA as an antioxidant. Results: Results from histological evaluation indicated that SOD and CD68 levels at the musculotendinous region and collagen fiber parallel to the orientation at the tendon-to-bone junction were not significantly different between the SR and PR groups. The mean load-to-failure of the PR group (20.32±9.37 N) was higher than that of the SR group (16.44±6.90 N), although this difference was not statistically significant (p=0.395). The SOD activity in the operative side infraspinatus muscle of the PR group was higher than that of the SR group, but the difference was not statistically significant (p=0.053). Conclusions: The use of PCA could improve tendon healing and decrease fatty degeneration after rotator cuff repair.

A plant-based multivitamin, multimineral, and phytonutrient supplementation enhances the DNA repair response to metabolic challenges

  • Yeo, Eunji;Hong, Jina;Kang, Seunghee;Lee, Wonyoung;Kwon, Oran;Park, Eunmi
    • Journal of Nutrition and Health
    • /
    • v.55 no.4
    • /
    • pp.450-461
    • /
    • 2022
  • Purpose: DNA damage and repair responses are induced by metabolic diseases and environmental stress. The balance of DNA repair response and the antioxidant system play a role in modulating the entire body's health. This study uses a high-fat and high-calorie (HFC) drink to examine the new roles of a plant-based multivitamin/mineral supplement with phytonutrients (PMP) for regulating the antioxidant system and cellular DNA repair signaling in the body resulting from metabolic stress. Methods: In a double-blind, randomized, parallel-arm, and placebo-controlled trial, healthy adults received a capsule containing either a PMP supplement (n = 12) or a placebo control (n = 12) for 8 weeks. Fasting blood samples were collected at 0, 1, and 3 hours after consuming a HFC drink (900 kcal). The blood samples were analyzed for the following oxidative stress makers: areas under the curve reactive oxygen species (ROS) levels, plasma malondialdehyde (MDA), erythrocytes MDA, urinary MDA, oxidized low-density lipoprotein, and the glutathione:oxidized glutathione ratio at the time points. We further examined the related protein levels of DNA repair signaling (pCHK1 (Serine 345), p-P53 (Serine 15), and 𝛄H2AX expression) in the plasma of subjects to evaluate the time-dependent effects of a HFC drink. Results: In a previous study, we showed that PMP supplementation for eight weeks reduces the ROS and endogenous DNA damage in human blood plasma. Results of the current study further show that PMP supplementation is significantly correlated with antioxidant defense. Compared to the placebo samples, the blood plasma obtained after PMP supplementation showed enhanced DNA damage response genes such as pCHK1(Serine 345) (a transducer of DNA response) and 𝛄H2AX (a hallmark of DNA damage) during the 8 weeks trial on metabolic challenges. Conclusion: Our results indicate that PMP supplementation for 8 weeks enhances the antioxidant system against oxidative stress and prevents DNA damage signaling in humans.

Optimization of base-isolated structure with negative stiffness tuned inerter damper targeting seismic response reduction

  • Jean Paul Irakoze;Shujin Li;Wuchuan Pu;Patrice Nyangi;Amedee Sibomana
    • Earthquakes and Structures
    • /
    • v.25 no.6
    • /
    • pp.399-415
    • /
    • 2023
  • In this study, we investigate the use of a negative stiffness tuned inerter damper system to improve the performance of a base-isolated structure. The negative stiffness tuned inerter damper system consists of a tuned inerter damper connected in parallel with a negative stiffness element. To find the optimal parameters for the base-isolated structure with negative stiffness tuned inerter damper system, we develop an optimization method based on performance criteria. The objective of the optimization is to minimize the superstructure acceleration response ratio, while ensuring that the base displacement response ratio remains below a specified target value. We evaluate the proposed method by conducting numerical analyses on an eight-story building. The structure is modeled using both a simplified 3-degree-of-freedom system and a more detailed story-by-story shear-beam model. Lastly, a comparative analysis using time history analysis is performed to compare the performance of the base-isolated structure with negative stiffness tuned inerter damper system with that of the base-isolated structure and base-isolated structure with tuned inerter damper systems. The results obtained from the comparative analysis show that the negative stiffness tuned inerter damper system outperforms the tuned inerter damper system in reducing the dynamic seismic response of the base-isolated structure. Overall, this study demonstrates that the negative stiffness tuned inerter damper system can effectively enhance the performance of base-isolated structures, providing improved seismic response reduction compared to other systems.

The nasoalveolar molding technique versus DynaCleft nasal elevator application in infants with unilateral cleft lip and palate

  • Abdallah Bahaa;Nada El-Bagoury;Noura Khaled;Sameera Mohamed;Ahmed Bahaa;Ahmed Mohamed Ibrahim;Khaled Mohamad Taha;Mohsena Ahmad Abdarrazik
    • Archives of Craniofacial Surgery
    • /
    • v.25 no.3
    • /
    • pp.123-132
    • /
    • 2024
  • Background: The introduction of presurgical nasoalveolar molding represented a significant departure from traditional molding methods. Developed by Grayson and colleagues in 1993, this technique combines an intraoral molding device with a nasal molding stent. This study aimed to compare the Grayson nasoalveolar molding appliance versus DynaCleft appliance as two methods of presurgical nasoalveolar molding. Methods: A single-blinded, randomized, parallel-arm clinical trial was conducted. Sixteen infants with complete unilateral cleft lip and palate were enrolled and divided into two groups of eight. Group 1 was treated with a modified Grayson nasoalveolar molding appliance that included a nasal stent, while group 2 was treated with DynaCleft elastic adhesive tape and an external nasal elevator. Standardized digital photographs of each infant were taken at baseline and post-treatment using a professional camera. Nine extraoral anthropometric measurements were obtained from each image using image measurement software. Results: The modified Grayson nasoalveolar appliance demonstrated a more significant improvement compared to DynaCleft in terms of alar length projection (on both sides), columella angle, and nasal tip projection. Symmetry ratios also showed enhancement, with significant improvements observed in nasal width, nasal basal width, and alar length projection (p< 0.05). Conclusion: Both the modified Grayson nasoalveolar appliance and DynaCleft appear to be effective presurgical infant orthopedics treatment options, demonstrating improvements in nasolabial aesthetics. The modified Grayson appliance, equipped with a nasal stent, improved nasal symmetry more effectively than DynaCleft, resulting in a straighter columella and a more medially positioned nasal tip.

Investigation on Individual Variation of Organ Doses for Photon External Exposures: A Monte Carlo Simulation Study

  • Yumi Lee;Ji Won Choi;Lior Braunstein;Choonsik Lee;Yeon Soo Yeom
    • Journal of Radiation Protection and Research
    • /
    • v.49 no.1
    • /
    • pp.50-64
    • /
    • 2024
  • Background: The reference dose coefficients (DCs) of the International Commission on Radiological Protection (ICRP) have been widely used to estimate organ doses of individuals for risk assessments. This approach has been well accepted because individual anatomy data are usually unavailable, although dosimetric uncertainty exists due to the anatomical difference between the reference phantoms and the individuals. We attempted to quantify the individual variation of organ doses for photon external exposures by calculating and comparing organ DCs for 30 individuals against the ICRP reference DCs. Materials and Methods: We acquired computed tomography images from 30 patients in which eight organs (brain, breasts, liver, lungs, skeleton, skin, stomach, and urinary bladder) were segmented using the ImageJ software to create voxel phantoms. The phantoms were implemented into the Monte Carlo N-Particle 6 (MCNP6) code and then irradiated by broad parallel photon beams (10 keV to 10 MeV) at four directions (antero-posterior, postero-anterior, left-lateral, right-lateral) to calculate organ DCs. Results and Discussion: There was significant variation in organ doses due to the difference in anatomy among the individuals, especially in the kilovoltage region (e.g., <100 keV). For example, the red bone marrow doses at 0.01 MeV varied from 3 to 7 orders of the magnitude depending on the irradiation geometry. In contrast, in the megavoltage region (1-10 MeV), the individual variation of the organ doses was found to be negligibly small (differences <10%). It was also interesting to observe that the organ doses of the ICRP reference phantoms showed good agreement with the mean values of the organ doses among the patients in many cases. Conclusion: The results of this study would be informative to improve insights in individual-specific dosimetry. It should be extended to further studies in terms of many different aspects (e.g., other particles such as neutrons, other exposures such as internal exposures, and a larger number of individuals/patients) in the future.