• Title/Summary/Keyword: Effluent treatment

Search Result 1,090, Processing Time 0.028 seconds

Decolorization System of Effluent of Activated Sludge Process Using Ozone (오존에 의한 활성오니처리 방류수의 탈색처리 연구)

  • 최희철;곽정훈;최동윤;권두중;김형호;이덕수;강희설;최영수;천상석
    • Journal of Animal Environmental Science
    • /
    • v.8 no.3
    • /
    • pp.153-158
    • /
    • 2002
  • Decolorization system using ozone was developed to reduce the pollutants and dark brown color remained in effluent of activated sludge process for pig wastewater. The results are as follows. 1. Wastewater temperature was increased during the ozone treatment from 31$^{\circ}C$ to 41.9$^{\circ}C$. 2. Oxidation reduction potential(ORP) at the beginning time was 148㎷, but it was increased to 330㎷ according to the ozone treatment. 3. 11mg/l of BO $D_{5}$ in effluent of activated sludge process was decreased to 1mg/l by ozone treatment, CO $D_{MN}$ also decreased from 83mg/l to 1.0mg/l. 4. 442 unit(dark brown color) of color in effluent of activated sludge process was changed to 6 units(colorless), and color removal efficiency was 98.6%.

  • PDF

Nitrogen and Phosphorus Removal in Effluent from the Fish Culture farm by Using Water Lettuce, Pistia stratiotes (물상추를 이용한 양어장 배출수의 질소 및 인의제거)

  • 박종호;이원호;조규석;황규덕
    • Journal of Aquaculture
    • /
    • v.16 no.4
    • /
    • pp.252-256
    • /
    • 2003
  • Effluent from farm trefish contained high concentrations of nitrogen and phosphorus, such kinds of nutrients were released to the environment without proper treatment and thses increased the pollution of the environment. We evaluated the conventional treatment system with cost effective ecotechnologies for the removal of nutrients. Water lettuce chambers were investigated under the various experimental conditions to improve the efficiency of N&P removal and the treatment of from aquaculture effluent. In this research, six water lettuce chambers (80 liter each) received combination of aquaculture wastewater effluent at hydraulic retention times (HRTs) of 1, 2, 4 and 8days. The water lettuce chambers operated at a 8 day HRT investigated for aquaculture effluent (1'st) showed average removal efficiency, BOD, T-N, T-P of 92.8, 79.0 and 93.6% on average respectively.

The Characteristics with HRT Variation on InSub Pilot Plant for Advanced Sewage Treatment

  • Kang, Jin-Young;Huh, Mock
    • Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.174-179
    • /
    • 2009
  • The InSub system(applied for a patent) was developed, as it combined the indirectly aerated submerged biofiltration(InSub) reactor and Anaerobic/ Anoxic reactor. This system which can eliminate organism and nutrient materials at the same time, which is safe and economical to be maintained and managed is more simple process than the complicated existing biological advanced sewage treatment system. The most suitable HRT of this study showed 9 hours. As looking into the effluent concentration and removal efficiency of each item at 9 hours of HRT, each effluent concentration for $SS,\;BOD5,\;COD_{Mn},\;and\;COD_{Cr}$ was 1.46 mg/L, 7,09 mg/L, 9.84 mg/L and 16.42 mg/L. And their removal efficiency was 96.98%. 90.59%, 77.18% and 83.92%, respectively. Each effluent concentration of T-N and T-P was 10.42 mg/L and 1.04 mg/L. Their removal efficiency was 73.38% and 61.62%, respectively. This pilot plant experiment(the state was without the internal recycling.) followed a variety of HRT. The results confirmed that it was to be advanced sewage treatment system with high efficiency when it combined with the internal recycling.

Feasibility Study of UV-Disinfection for Water Reuse of Effluent from Wastewater Treatment Plant (용수재이용을 위한 하수처리 유출수의 UV 소독 효율 연구)

  • 윤춘경;정광욱;함종화;전지홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.2
    • /
    • pp.126-137
    • /
    • 2003
  • The feasibility study of UV-disinfection system was performed for disinfection of effluent from wastewater treatment plant. Three low-pressure UV lamps of 17, 25, and 41 W were examined with various flow rates. Low-pressure UV lamps of 17W were examined with various turbidity, DOM (dissolved organic matter), and SS (suspended solid). The pilot plant was a flow-through type UV-disinfection system, and the range of exposure time varied from 5 to 40 seconds, turbidity from 0 to 40 NTU, DOM from 0 to 30 mg/L, and SS from 10 to 40 mg/L. The 41W lamp demonstrated complete disinfection showing no survival ratio in all the experimental conditions, and generally 17W and 25W lamps also showed high removal ratio over 97%. For the same UV dose (UV intensity times exposure time), high intensity-short exposure conditions showed better disinfection efficiency than low intensity-long exposure conditions. While the effects of turbidity and DOM were not apparent, the effects of SS was significant on the disinfection efficiency which indicates that SS control before UV-disinfection appears to be necessary to increase removal efficiency. Considering characteristics of effluent from existing wastewater treatment plants, cost-effectiveness, stable performance, and minimum maintenance, the flow-through type UV-disinfection system with high intensity and low-pressure lamps was thought to be a competitive disinfection system for wastewater reclamation.

Effect of Gamma-ray Treatment on Toxicity of Textile and Pigment Wastewaters (감마선 처리가 섬유와 안료폐수의 생물독성에 미치는 영향)

  • Kim, Eun-Ae;Jo, Hun-Je;Park, Eun-Joo;Kim, Hyo-Jin;Kim, Jeong-Gyu;Jung, Jinho
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.145-149
    • /
    • 2006
  • Textile and pigment wastewater samples collected from an industrial complex showed toxic effect on Daphnia magna. For textile wastewater, 48 h acute toxicity of effluent was not detected while toxic unit (TU) of influent was 1.79. The toxicity of influent was completely disappeared by gamma-ray treatment at 10 kGy or by suspended solids (SS) removal. In case of pigment wastewater, both influent and effluent were toxic to D. magna though the effluent satisfied current water quality standards. Gamma-ray treatment had little effect on the toxicity reduction of pigment wastewater since the toxicity was mainly caused by metal ions, in particular, Cr(VI). This work suggests the bioassay technique for monitoring adverse effects of wastewater should be introduced, and also shows the usefulness of gamma-rays as an advanced treatment technique for textile wastewater.

The Limiting Nutrient of Eutrophication in Reservoirs of Korea and the Suggestion of a Reinforced Phosphorus Standard for Sewage Treatment Effluent (국내 호수의 제한영양소와 하수처리장 방류수 인 기준 강화의 필요성)

  • Kim, Bomchul;Sa, Seung-Hwan;Kim, Moonsook;Lee, Yunkyoung;Kim, Jai-Ku
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.512-517
    • /
    • 2007
  • The limiting nutrient of eutrophication in freshwater bodies in Korea was examined and the phosphorus concentration standard for sewage treatment effluent was discussed. The weight ratio of N/P in 13 major reservoirs showed the range of 18 to 163, which implies phosphorus is more limited than nitrogen for algal growth. In the correlation analysis phosphorus showed higher correlation with chlorophyll-a concentration than with nitrogen. In the algal bioassay phosphorus spike test enhanced algal growth in all 25 samples of five reservoirs, while nitrogen was found to co-limit only in four samples. It confirms that phosphorus is the only limiting nutrient for eutrophication in Korean reservoirs. As many reservoirs are eutrophic in Korea, phosphorus control is critical for the management of water quality. The phosphorus standard of sewage treatment effluent in Korea was compared with other countries, and it can be concluded that phosphorus standard is too high to be effective in eutrophication control and a lower phosphorus standard is essential for the water quality improvement.

Parametric study of brewery wastewater effluent treatment using Chlorella vulgaris microalgae

  • Choi, Hee-Jeong
    • Environmental Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.401-408
    • /
    • 2016
  • The aim of this study was to evaluate the biomass and lipid production of Chlorella vulgaris and its nutrient removal capability for treatment of brewery wastewater effluent. The results indicate that the maximum biochemical oxygen demand (BOD) (91.43%) and chemical oxygen demand (COD) (83.11%) were removed by C. vulgaris with aeration in the absence of light. A maximum of 0.917 g/L of dry biomass was obtained with aeration in the dark conditions, which also demonstrated the highest amount of unsaturated fatty acids at 83.22%. However, the removal of total nitrogen (TN) and total phosphorus (TP) with these aeration and light conditions was 9.7% and 11.86% greater than that of other conditions. The removal of BOD and COD and the production of biomass and lipids with aeration in the dark and the TN and TP removal with aeration and light were more effective than other conditions in the brewery wastewater effluent in the presence of C. vulgaris.

A Study on the Color Removal in the Secondary Effluent (하수처리장 방류수 색도 제거에 관한 연구)

  • 이면주;정영도;진준하
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.3
    • /
    • pp.30-36
    • /
    • 1998
  • A study on the color removal by irradiation of ${\gamma}-ray$ was carried out to reclaim the secondary effluent for the purpose of industrial water. Coagulation, ozone and ion exchange methods were compared. It could know that irradiation method was the most effective in color removal. The color was removed by 87.5% at 0.5 Mrad and it was increase with dose. High removal efficiency could be obtained in low pH and low concentration of $CO3^{-2}$. This process can be applied to the treatment of secondary effluent and is considered to be one of the most useful tertiary treatment.

  • PDF

Development of GIS System for Agriculture Reuse of Wastewater Resource (GIS를 이용한 농업용수 재이용 활용시스템 개발)

  • Kim, Hae-Do;Lee, Gwang-Ya;Jeong, Gwang-Geun;Lee, Jong-Nam
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.479-484
    • /
    • 2005
  • A GIS-based integrated system for reuse of effluent from wastewater treatment plants was developed in this study. The GIS-supported program classified attribute data which the effluent's quantity and quality and agricultural thematic map data according to the 5 big river basin area. From the database, showing the spatial variation of the water quality of the effluent, thereby proposing proper mitigation strategies over the watershed. Also, this system enables the users who is going to reuse the reclaimed water for their paddies to provide of all the wastewater treatment plant data and agricultural structures and thematic map data.

  • PDF

USE OF FOULING RESISTANT NANOFILTRATION AND REVERSE OSMOSIS MEMBRANES FOR DYEING WASTEWATER EFFLUENT TREATMENT (막오염 저항성이 우수한 나노여과 및 역삼투막의 염색폐수 적용)

  • Myoung, Su-Wang;Park, In-Hwan;Ka, Young-Hyun;Kim, In-Chul;Lee, Kew-Ho
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05b
    • /
    • pp.136-139
    • /
    • 2004
  • The dyeing effluent is a highly colored stream containing unfixed dyes along with salts and auxiliary chemicals such as emulsifying agents. Moreover, Textile dying is a chemically intensive process and consumes large quantities of water. Difficulties in the effluent treatment arise from its non-degradable property by aerobic digestion.(omitted)

  • PDF