• 제목/요약/키워드: Effluent recycling

검색결과 96건 처리시간 0.022초

An Overview of NRC Projects in Wastewater Treatment by Membrane Processes

  • Kumar, Ashwani
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1997년도 제5회 하계 Workshop (97 한,카 국제공동 Workshop, 고도 수처리를 위한 막분리 공정)
    • /
    • pp.55-66
    • /
    • 1997
  • A brief introduction to NRC's research activities will be given with special emphasis on membrane processes. NIRC's membrane research group has been involved in many membrane research projects with industrial clients in various sectors of the industry. These projects generally were focused on using membranes for treating industrial wastewater streams for recycling process water, recovering of valuable components and meeting the environmental regulations. The group looked in to various aspects of process development dealing with membrane performance evaluation, optimization of operational parameters, determination of fouling propensities of membranes and simple cost analyses in some cases. Case studies dealing with process development for effluent treatment for the pulp & paper, mining & mineral processing and poultry processing industries will be discussed briefly.

  • PDF

하구환경의 생태적 설계 (Ecological Design of Estuarine Environment)

  • 양홍모
    • 한국조경학회지
    • /
    • 제23권2호
    • /
    • pp.167-181
    • /
    • 1995
  • An Ecocomplex is proposed for ecological design of the estuarine environment of Han River, which is designed upon an alternative mamagement concept of estuarine environment. The concept reveals interrelationships among estuary, delta region and urban inland with inputs/outputs and feedbacks among them. The Ecocomplex emphasizes an integration of wastewater treatment with aquaculture, agriculture and recreation, and carries out ecological treatment, recycling, and harvest processes. A module of wastewater treatment pond system is employed in the Ecocomplex, which treats a flow of 3,786 ㎥/day and is composed of a four-facultative-pond series. Treatment ponds stabilize wastewater discharged from the urban area, and concurrently produce algae for commercial or recreational fish farming. Effluent from treatment and fish ponds is reused for agricultural production. Through the waste-algae-fish-vegetable-recreation processes, wastewater from the urban settlement is recycled back to the urban ecosystem. This resource-conserving design approach can maintain a sustainable urban ecosystem, managing an estuarine environment more naturally, healthly, and economically.

  • PDF

하수처리장 에너지자립화사업에서 혐기성소화공정으로부터 용출되는 용존성질소($NH_3-N$)의 처리 필요성 연구 (The Study of the Need to Remove Soluble nitrogen ($NH_3-N$) Generated from Anaerobic digestor Retrofitted in Municipal Wastewater Treatment Plants)

  • 안세영
    • 유기물자원화
    • /
    • 제22권3호
    • /
    • pp.68-75
    • /
    • 2014
  • 하수슬러지를 혐기성 소화하는 과정에서 용출되는 용존성질소는 다시 수처리시설로 반송되어 질산화 효율이 떨어지는 동절기 법적 방류수 질소 수질기준에 영향을 준다. 컴퓨터 시뮬레이션 소프트웨어(GPS-X)를 이용하여 A하수처리시설을 대상으로 소화조에서 발생하는 용존성질소의 영향을 조사한 결과, 소화조가 있는 처리시설에서의 총 반송수와 1차침전지 유입수 용존성질소 농도는 소화조가 없는 시설에서의 농도보다 각각 214.1 mg/L, 6.2 mg/L 높게 산출되었다. 슬러지 처리시설에서의 반송수를 처리하는 반송수처리시설(부상분리조)을 설치하는 경우 총반송수 용존성질소 농도는 반송수처리시설이 없는 경우보다 6.0 mg/L 높게 나타났으며 1차침전지 유입수 용존성질소 농도를 0.7 mg/L 낮게 산정되었다. 시뮬레이션 결과, 하수슬러지를 혐기성소화하여 에너지자립화율을 향상시키는 사업에서 슬러지 처리시설에서 발생하는 여액과 상등액의 용존성질소($NH_3-N$)를 처리할 수 있는 시설이 필요한 것으로 나타났다.

유기성폐자원에너지 인센티브제도 도입방안 연구(II): 바이오가스화 물질·에너지수지 (A study on the introduction of organic waste-to-energy incentive system(II): material and energy balance of biogasification)

  • 문희성;권준화;이원석;이동진
    • 유기물자원화
    • /
    • 제29권4호
    • /
    • pp.77-86
    • /
    • 2021
  • 본 연구에서는 유기성폐자원에너지 인센티브제도의 기초자료로 활용하고자 음식물폐기물, 음폐수 및 다양한 유기성폐기물이 처리되는 혐기소화조의 운영방식의 물질수지와 에너지수지 산정 결과를 통하여 에너지효율을 평가하고자 한다. 바이오가스화 시설 11개소의 물질수지 분석 결과 유기성폐기물을 제외한 반입물 중 공정수 21.1%, 시상수 25.7 % 다량 투입되는 것을 확인하였다. 그에 따라 연계처리수의 전체 유출물의 87.6 %를 차지하였다. 또한 총 유입물량의 15.7 %가 바이오가스로 전환되며, 총고형물(TS)가 평균 22 %임을 감안할 때 평균 75 %의 물질 전환율을 확인하였다. 에너지수지 분석 결과, 유입물의 잠재에너지 대비 바이오가스 열량을 분석하여 에너지 전환율은 평균 78.5%을 확인하였다. 바이오가스를 생산하기 위한 외부에너지원을 포함한 바이오가스 생산효율은 평균 69.4 %이며, 미이용된 유출에너지를 적용한 바이오가스 플랜트 효율은 평균 58.9 %로 나타났다.

유동상식 소각로에서 발생되는 폐유동사(廢流動床) 처리 및 재활용 방안 (A Study on Treatment and Recycling of Waste Fluid Sand from the Fluidized Bed Incinerator)

  • 이승원
    • 한국환경과학회지
    • /
    • 제29권11호
    • /
    • pp.1015-1024
    • /
    • 2020
  • Using the waste(sand wastr and boiler ash) in fluidized bed inciverator, lightweight aggregate concrete was produced and a recycling plan was prepated. The first, the result of the leaching test shows that the waste fluid sand and boiler ash did not exceed the effluent standard. This indicates that there is no harmful effect for recycling. The second, in the lightweight aggregate test using waste fluid sand and boiler ash, the sample that combined cement, waste fluid sand, and sand showed the highest compressive strength, and the mix proportion was 10: 7: 3. Lightweight aggregate concrete that combined cement, waste fluid sand, boiler ash, and sand had a low compressive strength by and large. The third, the same results were identified in the relation between the content of SiO2 and that of Na2O. As the SiO2 content is lowered, the overall viscosity and plasticity of the concrete also decrease, which is not a good condition to form concrete. As for Na2O, as the content increases, the viscosity of the sample and the viscosity of the cement are remarkably lowered, and the strength of the finished concrete is lowered. Therefore, it was concluded that the higher the content of SiO2 and the lower the content of Na2O, the more suitable it is to mix with cement to produce concrete. Fourth, from the fluidized bed incinerator currently operated by company A in city B, a total of 14,188 tons/year were discharged as of 2016, including 8,355 tons/year of bottom ash (including waste fluid sand) and 5,853 tons/year of boiler ash. The cost for landfill bottom ash and boiler ash discharged is 51,000 won/ton, and the total annual landfill cost is 723,588,000 won/ year. Assuming that the landfill tax to be applied from the year 2018 is about 10,000 won/ton, and if there is no reduction in waste disposal charge, an additional landfill tax of 141,880,000 won/year will be imposed. Consequently, the sum total of the annual landfill cost will be 865,468,000 won/year. Therefore, if the entire amount is used for recycling, the annual savings of about 8.7 billion won can be expected.

신경회로망을 이용한 순환식 돈분폐수 처리시스템의 모니터링

  • 최정혜;손준일;양현숙;정영륜;이민호;고성철
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 춘계학술발표대회
    • /
    • pp.125-128
    • /
    • 2000
  • 본 연구에서는 순환식 돈분 폐수 처리 시스템에서의 미생물 분포에 따른 폐수 처리 효과를 모델링하기 위해 신경회로망과 PCA를 이용하는 새로운 방법을 제안하였다. PCA 분석 결과를 바탕으로 신경회로망의 최적 입력 조건을 찾고, 실측 데이터를 이용하여, 폐수 처리 시스템의 각 탱크를 별도로 학습함으로써 비교적 적은 수의 데이터에도 불구하고 정확한 모델링 결과를 얻었다. 제안한 시스템은 폐수 처리 시스템의 효과적인모니터링 시스템으로 사용할 수 있으며, 향후 실제 돈분 처리 시스템에서 원하는 기준의 방류수를 얻기 위한 최적의 입력조건 (미생물밀도 등)을 결정하는데 있어서 에뮬레이터로 사용될 수 있을 것으로 기대된다.

  • PDF

막결합형 고온 이상 혐기성 소화공정에서 음폐수 처리 특성 (Characteristics of Food Waste Leachate Treatment in Thermophilic two Stage Anaerobic Digestion Combined UF Membrane)

  • 김영오;전덕우
    • 유기물자원화
    • /
    • 제20권3호
    • /
    • pp.21-24
    • /
    • 2012
  • 본 연구에서는 폐기물 자원화 공정에서 발생하는 음폐수를 UF 분리막을 결합한 혐기성 소화 파일럿 에서 처리하면서 혐기성 소화효율, 바이오가스 생산량과 운전인자를 도출하였다. 운전방식은 막내부에서 외부로 고액분리가 이루어지는 가압식이었으며, 투과 플럭스는 15∼20 LMH, 막간 차압은 $1{\sim}3 kgf/cm^2$였다. 분리막 운전은 직접순환방식으로 운전한 결과, 메탄조의 수질악화로 간접순환방식으로 운전하였다. 유입수의 TCOD 와 SCOD 는 각각 113 g/L, 62 g/L 이었고, 유출수의 TCOD 와 SCOD는 각각 25 g/L, 12 g/L 이었다. TCOD 및 SCOD 제거효율은 각각 77% 및 81%였다. 하지만 UF 공정을 추가했을 때는 제거효율이 93% 및 86%로 증가하였다.

음식물폐기물과 축산분뇨 혼합폐수의 이상혐기소화에 따른 소화액의 위생성 연구 (Two-Phase Anaerobic Digestion of Food and Livestock Wastewater and Hygienic Aspects of the Digested Water)

  • 정두영;정명희;김영준
    • 유기물자원화
    • /
    • 제17권4호
    • /
    • pp.66-73
    • /
    • 2009
  • 음식물류폐수와 축산분뇨를 1:1로 혼합한 폐수를 대상으로 고온/중온의 이상혐기소화공정을 실시하였고 혼합폐수내 병원성미생물의 존재 및 소화과정중 미생물상의 변화를 살펴보았다. 혼합원액내 미생물은 대장균, 분변성 장내세균, 대장균군 등의 장내세균총을 비롯하여 식중독을 일으키는 포도상구균과 살모넬라, 이질의 원인균인 쉬겔라, 유가공제품내 대표적 병원성세균인 리스테리아 및 효모 등이 검출되었다. 혐기소화의 안정화시기는 반응후 21일이 지나서부터 시작하였으며, 이 시기를 전후하여 산 발효조와 메탄발효조에서 각각 80% 및 90% 내외의 가파른 감소율을 보이며 대부분의 미생물이 감소되었다. 안정화이후 유기물의 평균분해율은 메탄발효조에서 60% 내외를 기록하였다. 메탄 발효조를 거친 소화액내 미생물개체수는 반응종료 시점에서 대부분 불검출 되었으나, 리스테리아와 포도상구균의 경우, 비교적 완만한 감소세를 보이며 반응최종일까지 검출이 되고 있음을 확인하였다.

  • PDF

음식폐기물과 하수슬러지 병합처리를 위한 전처리시설에 관한 연구 (A Study on Pre-treatment Facility for Foodwaste and Sewage Sludge Mixture)

  • 김종오;이창호;김지영
    • 유기물자원화
    • /
    • 제11권1호
    • /
    • pp.84-89
    • /
    • 2003
  • 본 연구는 음식폐기물과 하수슬러지의 병합처리를 위한 음식폐기물 전처리시설을 평가하고 그 활용방안을 모색하기 위하여 수행되었다. 본 연구에서 이용한 음식폐기물 전처리시설은 저장, 선별분쇄, 농축의 순으로 구성되어 있으며, 하수처리장 방류수를 희석수로 이용하여 선별분쇄시 파쇄를 용이하게 하고 염분농도의 희석효과도 가져올 수 있었다. 파쇄된 음식폐기물의 입자는 대부분 2mm 이하로 하수슬러지와 혼합하여 혐기성소화시 효율이 높은 것으로 조사되었다. 기존 하수슬러지 처리시 발생되는 가스발생량은 0.8톤/일(메탄 0.5톤/일)로 매우 낮았으나 음식폐기물과의 병합처리후에는 3.5톤/일(메탄 2.3톤/일)의 소화가스가 발생하는 것으로 조사되었다. 탈수슬러지의 발생량 또한 기존 11.2톤/일에 비해 21.2톤/일로 증가하지만 하수슬러지에 비해 유기물 함량이 높으므로 재활용 가치가 높을 것으로 판단된다. 따라서 음식폐기물 전처리시설의 적절한 활용을 통해 기존 하수처리시설과의 연계 처리가 가능할 것으로 판단된다.

  • PDF

pH와 완속교반 조건에 따른 중금속 수산화물 화학침전 특성 (Effects of pH and slow mixing conditions on heavy metal hydroxide precipitation)

  • 박종훈;최규진;김상현
    • 유기물자원화
    • /
    • 제22권2호
    • /
    • pp.50-56
    • /
    • 2014
  • 일반적으로 도금 폐수를 비롯한 산업 폐수 내 중금속 처리에 적용되는 응집-침전은 응집제의 비용과 침전 효율의 불안정성이라는 한계가 존재한다. 본 연구에서는 수산화물 생성-분리막 공정을 전제로 하여, pH와 교반조건에 따른 수용액 상의 중금속 제거 효율과 생성된 수산화물의 입도 분포를 고찰하였다. pH별 실험 결과, pH 9-10에서 최적의 중금속 제거 효율이 확인되었으며, 무기응집제인 $FeCl_3$의 투입은 오히려 제거 효율을 저하시켰다. 완속교반 시간 및 강도는 70 rpm, 20 min 조건이 최대 효율을 보였으며 Cu, Ni, Zn 모두 청정 지역 기준 폐수 배출 기준을 만족하였다. 나타났다. 생성된 중금속 수산화물의 입도 분석을 수행한 결과, 입자의 99.9 %가 $2{\mu}m$ 이상이었다.