• Title/Summary/Keyword: Effluent quality

Search Result 614, Processing Time 0.029 seconds

Protozoa as an Indicator of Effluent Quality at Advanced Wastewater Treatment Plants (고도폐수처리장에서 원생동물을 이용한 수질예측)

  • Lee, Chan-Hyung;Moon, Kyung-Suk;Park, Sang-Jung;Lee, Eun-Ju;Cho, Jae-Keun;Jin, Ing-Nyol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.4
    • /
    • pp.389-396
    • /
    • 2006
  • A quantitative survey of the protozoa microfauna at two advanced wastewater treatment plants has been carried out on a weekly basis. The abundance of the protozoa were compared with operating parameters and effluent quality using statistical procedures. The protozoa distribution indicated it seemed the composition of the influent wastewater and operating conditions of plant influenced the structure of protozoa in the plant. In statistical analysis, the distribution of protozoa showed the present operating condition of plant and predicted near-future effluent qualify. Enough data concerning protozoa, operating parameters and effluent has been gathered, the operator has a valuable tool for predicting plant performance and near-future data of effluent based on microscopic examination. Perhaps more importantly it can be used to actually control the plant to adjust the operating conditions to obtain the protozoal populations that have been shown to provide the best effluent quality.

An Experimental Investigation for Efficient Operation of Septic Tank (정화조의 효율적인 운영을 위한 실험적 고찰)

  • Lee, Jang-Hown;Lee, Kyeong-Soo;Kho, Soo-Hoon;Song, Min-Hee;Lee, Soo-Hyun;Lee, Yong-Hoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.123-129
    • /
    • 2012
  • A septic tank is a purification treatment system where night soil and other waste matter is converted into harmless material by the activities of bacteria. Effluent from the septic tank flows into the sewer pipe, and then this effluent affects the quality of water environment and makes foul smell. In this study, through the proper maintenance of septic tank it was tried to minimize the impact of sewer pipe on water quality and fouling smell. BOD removal rate from the septic tank's effluent which exceeded legal cleaning period was investigated for the proper maintenance. BOD Removal rate of the twelve septic tank's effluent is -62.5% to 43.9%. According to the result of BOD removal rate, septic tank cleaning should be done at least once a year. And the pathogenic coliform bacillus in the twelve septic tank's effluent is average 768,000 (MPN/$100m{\ell}$). The chlorine disinfection is needed to remove the pathogenic coliform bacillus in septic tank effluent.

A Study on the Determination Method of TOC Effluent Limitation for Public Sewage Treatment Plants (하수처리시설의 방류수 수질기준 설정방법 고찰 - TOC를 중심으로 -)

  • Jeong, Dong-Hwan;Cho, Yangseok;Ahn, Kyunghee;Chung, Hyen-Mi;Park, Hoowon;Shin, Hyunsang;Hur, Jin;Han, Daeho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.241-251
    • /
    • 2016
  • As the Enforcement Ordinance of Environmental Policy Act was revised in 2013, total organic carbon(TOC) was added as an indicative parameter for organic matter in Water and Aquatic Ecosystem Environmental Criteria. Under these imminent circumstances, a regulatory standard is needed to achieve the proposed TOC limitation control water quality from the public sewage treatment plants(PSTWs). This study purposes to present the determination method for TOC effluent limitation at the PSTWs. Therefore we investigate the TOC effluent limitation of foreign countries such as EU, Germany and USA, and analyse the effluent water qualities of PSTWs. In using these TOC data, we review apprehensively the statistics-based, the technology-based, and the region(water quality)-based determination method of TOC effluent limitation for PSTWs.

Study on Establishment of the Industrial Wastewater Effluent Limitations Based on Best Practicable Control Technology Currently Available - Case Study for the Pulp, Paper and Paper Board Manufacturing (실용 가능한 최적처리기술에 근거한 산업폐수 배출허용기준 설정 연구 - 펄프.종이 및 종이제품 제조시설 적용 사례)

  • Kim, Jaehoon;Shin, Jinsoo;Lee, Chulgu;Lee, Jungyoung;Lee, Youngsun;Yu, Soonju
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.4
    • /
    • pp.608-614
    • /
    • 2012
  • The effluent limitation of industrial wastewater is based on uniform regulatory criteria for effluent discharge facilities of all in Korea. But, an individual effluent limitation on each effluent discharge facility is widely applicable for regulation of industrial wastewater in US.EPA. To decide an individual effluent limitation, TBEL (Technology-based effluent limitation) and WQBEL (Water quality-based effluent limitation) are used. TBEL is based on the capability of a treatment technology to reduce the pollutants. WQBEL is based on ambient water quality standards. In this study, TBEL were derived for the pulp, paper and paper board manufacturing based on best practicable control technology currently available. It was suggested that effluent limitations were $BOD_5$ 4.7 mg/L, $COD_{Mn}$ 44.3 mg/L, SS 13.2 mg/L, TN 1.4 mg/L, TP 0.15 mg/L and best practicable control technology currently available (BPT) was neutralization, activated sludge treatment and coagulation and sedimentation for the pulp, paper and paper board manufacturing.

Evaluation of Korean Water Quality Standards in Winter by Characteristics and Statistical Analyses of the Effluent Water Quality at the Sewage Treatment Plants in Korea (우리나라 공공하수처리시설의 방류수 수질현황 분석을 통한 겨울철 방류수수질기준의 적정성 평가)

  • Um, Chul Yong;Chu, Kyoung Hoon;Yun, Zu Whan;Choi, Ik Hoon;Park, Jae Young;Lee, Han Saem;Ko, Kwang Baik
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.4
    • /
    • pp.523-532
    • /
    • 2011
  • In this study, from 2004 to 2008 influents and discharging effluents from 241 municipal public sewage treatment plants were surveyed. Statistics including average, Coefficient of Variation (CV) and Coefficient of Reliability (COR) for each season, time series analysis for removal efficiency and water quality of effluents, and a comparison of the effluent standards in Korea and other countries were presented. The average concentrations of TN and TP in influents. during winter season were 32.6 and 3.78 mg/L and during other season were 30.8 and 3.61 mg/L in 2008, respectively. The average TN concentration on the basis of the maximum monthly concentrations in the effluents during winter season ranged from 14.2~17.4 mg/L and during other season ranged from 12.2~14.8 mg/L. The TP concentration in the effluents depending on the each season was no big difference. TN removal efficiency decreased from Jan. to Feb. and TP removal efficiency decreased in Jan., Jun and July. Maximum COR during winter season were 0.61 but the COR for TN and TP during other season ranged from 0.96~1.48 and 1.09~1.81, respectively, due to big difference in the standard for TN and TP in effluents depending on the season. TN and TP standards for effluent of sewage treatment during winter season in Korea was much higher than those in other countries. Therefore the lower effluent standards during winter season is essential for the water quality improvement.

Waste Water Treatment Using Constructed Wetland and Pond System (인공습지와 연못시스템을 이용한 오수처리)

  • Kim, Min-Hee;Yoon, Chun-Gyeong;Ham, Jong-Hwa
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.470-474
    • /
    • 2001
  • A pilot study was performed at the experimental field of Konkuk University in Seoul, to examine the waste water treatment using constructed wetland and pond system. The effluent of the wetland system in winter often exceeded effluent water quality standards for sewage treatment plant, therefore, pond system could be applied to additional system. As a result, removal rate of $BOD_{5}$, SS was 84.4%, 81.5% and effluent concentration was 4.6mg/L and 5.0mg/L respectively, when surface water of pond system was discharged in March. So we concluded that pond system stored wetland effluent in winter and discharged surface water of pond system in March, so met water quality standard.

  • PDF

Water Quality Correlation Analysis between Sewage Treated Water and the Adjacent Downstream Water in Nakdong River Basin (낙동강유역의 하수처리장 방류수와 인접 하류하천의 수질상관관계 분석)

  • Cho, Hyun Kyung;Kim, Sang Min
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.2
    • /
    • pp.202-209
    • /
    • 2018
  • The purpose of this study was to analyze the correlation between the effluent of a sewage treatment plant (STP) and the adjacent stream located downstream of the STP in Nakdong River. Flow and water quality data, such as BOD, COD, SS, T-N, and T-P data, for 12 STPs and adjacent downstream monitoring stations in the main stream and tributaries of Nakdong River were collected from 2012 to 2015. As a result of correlation analysis between river flow and water quality at the river water quality measurement point, COD, SS, and T-P were correlated positively with the river flow rate at 6, 8, and 6 points, respectively. As a result of analyzing the water quality of sewage treatment plant effluents and downstream streams, BOD and COD were correlated at 2 and 3 points, respectively. T-N showed a positive correlation at 9 points, and 7 of them had a strong positive correlation, indicating that sewage treatment effluent had a large effect on downstream streams. In this study, we found that the correlation between the river flow rate and the water quality factors (COD, SS, TP) was high at river water measurement points, and the sewage treatment plant effluent was correlated with the T-N value of adjacent streams.

Feasibility Study on the Reuse of Treated Sewage Effluent for Agrcultural Water (농촌오수 처리수의 농업용수로의 재이용 가능성에 관한 연구)

  • 권태영;윤춘경
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.663-669
    • /
    • 1999
  • The objective of this study are to examine the feasbility of reuse treated sewage effluent ofr agricultural water, and to obtain basic data for estabilishment of rational agricultural water quality standard. From this study, it appears that reuse of treated sewage as a supplemental irrigation water could be feasible and practical alternative for ultimate sewage disposal which often causes water quality problem to the receiving water body. For full scale applicatiion, further study is recommended on the secific guidelines of major water quality components and publc health.

  • PDF

A Study on Water Environment and Benthic Macroinvertebrate Community in Reclaimed Wastewater Effluent Dominated Stream (하수처리수 방류 하천의 물환경과 저서성 대형무척추동물 군집 생태 연구)

  • Son, Jung-Won;Kwag, Jin-Suk;Cho, Gab-Je;Ryou, Dong-Choon
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.3
    • /
    • pp.190-203
    • /
    • 2021
  • Water quality, benthic macroinvertebrate communities, and other factors were investigated to explore the effects of the effluent discharge from a sewage treatment plant into Jwagwang stream in Busan in 2019. During the study period, the flow rate of this stream was in the range of 10,400 m3/day to 52,200 m3/day except for the discharge of about 24,000 m3/day of the effluent. After discharge, the flow velocity increased by about 65% and the water depth increased by about 40%. At sites downstream of the discharge point, BOD, COD, TOC, T-N, T-P, and other water quality values were worse than those of the upstream sites. The periphytic algal chlorophyll-a concentrations in the natural substrata were higher than those of the upstream sites, especially in May and August. However, at sites downstream of the discharge point, the individual numbers of Annelida were decreased and individual numbers of the insecta of arthropoda were increased. Also, species numbers and the diversity and dominance indexes were improved in the sites downstream of the discharge point. The functional feeding groups (FFGs) of collector-filterers were increased and the habitat orientation groups (HOGs) of sprawlers, burrowers, and clingers were especially increased at the sites with additional reclaimed wastewater effluent flow. Regardless of the effluent discharge, BMI, an indicator of ecological stream health using benthic macroinvertebrate species, did not show large gaps between the study points. Although the water quality of the sites downstream of the discharge point was much worse than those upstream, their ecosystem soundness was better than those of the upstream sites from an ecological perspective.

Analysis of Sewage Plant Operation by Statistical Approach (통계방법에 의한 하수처리장 운전분석)

  • 이찬형;문경숙
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.3
    • /
    • pp.34-38
    • /
    • 2002
  • Statistical analysis between sewage plant operating parameters and the effluent quality was performed. We extracted two factors from principal component analysis of operating parameters and effluent quality from each plant. The total variance of 84.7%, 79.2% was explained by the two factors at SB plant and SC plant, respectively. The factors were identified at SB plant in the following order 1) the oxidation of organic material by aeration basin microbe,2) biomass in aeration basin and at SC plant 1) the oxidation of organic material by aeration basin microbe, 2) thickening of acti-vated sludge. These results suggested that the control of microbial composition might be critical on the improvement of the effluent quality and plant operating efficiency because most of the factors were related with microbes.