• Title/Summary/Keyword: Effluent concentration

Search Result 796, Processing Time 0.029 seconds

Evaluation of operating performance of secondary effluents treatment membrane system adapted chemical backwashing (약품역세를 적용한 하수재이용 막여과 시스템의 운전성능 평가)

  • Kim, Young-Hoon;Lee, Chang-Ha;Jeon, Min-Jung;Lee, Yong-Soo;Lee, Eui-Jong;Nam, Jong-Woo;Kim, Hyung-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.335-342
    • /
    • 2011
  • Secondary effluent contains particle compounds which are comprised of microorganisms that occurs membrane fouling when the water is reused. This study evaluates the characteristics of membrane fouling of secondary effluent reuse. Effects of chemical backwashing are analyzed to reduce membrane fouling by regular chemical backwashing. As the result, major membrane foulants are verified EPS materials which include protein and polysaccharide that cause biofilm cake layer on the membrane. Also, sodium hypochlorite is applied to chemical backwashing. The backwashing improves recover rate when injected chemical concentration is increased and chemical backwashing cycle is amplified. Chemical backwashing cycle affects more than injected chemical concentration yet idle time does not noticeably influence on reducing membrane fouling.

Kinetic Analysis for Paper-mill Wastewater Treatment Using Pure Oxygen Activated Sludge Process (순산소 활성오니공정을 이용한 제지폐수처리의 동력학적 해석)

  • Kim, Sung Soon;Chung, Tai Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.2
    • /
    • pp.157-163
    • /
    • 2000
  • An experimental study was conducted to evaluate the treatment efficiency of paper-mill wastewater using pure oxygen activated sludge process. Effects of hydraulic retention time (HRT) and organic loading on process performance and kinetics were investigated. The raw paper-mill wastewater(BOD concentration ${\leq}500mg/L$) and the effluent from dissolved air flotation(DAF) treatment(BOD concentration ${\geq}500mg/L$) were used as influent for pure oxygen activated sludge process. Average BOD removal efficiencies were above 89.3% under 6hours or longer of HRT, while under 3hours of HRT they decreased to about 82%. With the effluent from DAF process, the half saturation constants($K_S$) and the maximum specific substrate removal rate($K_{max}$) were 85 mg/L and 2.25 L/day, respectively. However, with the raw paper-mill wastewater, both $K_S$ and $K_{max}$ increased to 156 mg/L and 3.84 L/day, respectively. The microbial yield coefficient(Y) and the decay coefficient($K_d$) were 0.46 gVSS/gBOD and 0.03 L/day, respectively, with effluent from DAF process. While, Y and $K_d$ were 0.24 gVSS/gBOD and 0.035 L/day, respectively, with the raw paper-mill wastewater.

  • PDF

The Limiting Nutrient of Eutrophication in Reservoirs of Korea and the Suggestion of a Reinforced Phosphorus Standard for Sewage Treatment Effluent (국내 호수의 제한영양소와 하수처리장 방류수 인 기준 강화의 필요성)

  • Kim, Bomchul;Sa, Seung-Hwan;Kim, Moonsook;Lee, Yunkyoung;Kim, Jai-Ku
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.512-517
    • /
    • 2007
  • The limiting nutrient of eutrophication in freshwater bodies in Korea was examined and the phosphorus concentration standard for sewage treatment effluent was discussed. The weight ratio of N/P in 13 major reservoirs showed the range of 18 to 163, which implies phosphorus is more limited than nitrogen for algal growth. In the correlation analysis phosphorus showed higher correlation with chlorophyll-a concentration than with nitrogen. In the algal bioassay phosphorus spike test enhanced algal growth in all 25 samples of five reservoirs, while nitrogen was found to co-limit only in four samples. It confirms that phosphorus is the only limiting nutrient for eutrophication in Korean reservoirs. As many reservoirs are eutrophic in Korea, phosphorus control is critical for the management of water quality. The phosphorus standard of sewage treatment effluent in Korea was compared with other countries, and it can be concluded that phosphorus standard is too high to be effective in eutrophication control and a lower phosphorus standard is essential for the water quality improvement.

Semiconductor coupled solar photo-Fenton's treatment of dyes and textile effluent

  • Raji, Jeevitha R.;Palanivelu, Kandasamy
    • Advances in environmental research
    • /
    • v.5 no.1
    • /
    • pp.61-77
    • /
    • 2016
  • $NanoTiO_2$ was synthesized by ultrasonication assisted sol-gel process and subjected to iron doping and carbon-iron codoping. The synthesized catalysts were characterized by XRD, HR-SEM, EDX, UV-Vis absorption spectroscopy and BET specific surface area analysis. The average crystallite size of pure $TiO_2$ was in the range of 30 - 33 nm, and that of Fe-$TiO_2$ and C-Fe $TiO_2$ was in the range of 7 - 13 nm respectively. The specific surface area of the iron doped and carbon-iron codoped nanoparticles was around $105m^2/g$ and $91m^2/g$ respectively. The coupled semiconductor photo-Fenton's activity of the synthesized catalysts was evaluated by the degradation of a cationic dye (C.I. Basic blue 9) and an anionic dye (C.I. Acid orange 52) with concurrent investigation on the operating variables such as pH, catalyst dosage, oxidant concentration and initial pollutant concentration. The most efficient C-Fe codoped catalyst was found to effectively destruct synthetic dyes and potentially treat real textile effluent achieving 93.4% of COD removal under minimal solar intensity (35-40 kiloLUX). This reveals the practical applicability of the process for the treatment of real wastewater in both high and low insolation regimes.

Characteristics of TOC in effluent discharge from public sewage treatment works in korea (우리나라 공공하수처리시설의 TOC 배출특성 및 관리방안 연구)

  • Jeong, Dong-Hwan;Choi, In-Cheol;Cho, Yangseok;Ahn, Kyunghee;Chung, Hyen-Mi;Kwon, Ohsang;Park, Hoowon;Shin, Hyunsang;Hur, Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.6
    • /
    • pp.657-668
    • /
    • 2014
  • Under Korea's Enforcement Decree of the Framework Act on Environmental Policy amended in 2013, total organic carbon (TOC) is newly added as water quality parameter to assess organic pollution in water and aquatic ecosystem. To meet the TOC requirement and improve quality of effluent discharged into public watershed, it is also necessary to develop standards for TOC in effluent from public sewage treatment works (PSTWs). In this study, we reviewed the characteristics and removal efficiency of TOC in influent and effluent of PSTWs. The study found that phosphorus treatment process removed not only soluble phosphorus but also a portion of TOC remaining after the secondary treatment process. TOC concentration in effluent from PSTWs operated in tandem with industrial wastewater treatment work was higher due to influx of insoluble substances from the industrial wastewater treatment work. In order to lay a foundation for the management of TOC from PSTWs, it is necessary to carry out research on TOC from different perspectives. For example, studies on the generation mechanism of TOC and the impact of TOC on drinking water resources, assessment of effluent qualities through monitoring, and development of measures to control TOC for the preservation of aquatic ecosystem are needed.

Alarm Setpoint Determination Method of Gaseous Effluent Radiation Monitoring Systems Using Dose Factors Based on ICRP-60 Recommendations (선량환산인자를 이용한 기체유출물 RMS 경보설정 개선방안)

  • 박규준;김희근;하각현;엄희문
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.491-496
    • /
    • 2003
  • In Korea, the dose limits to the public were reduced according to ICRP-60 recommendations. The secondary quantities, Effluent Concentration Limits (ECLs) were derived and enacted to Korean Atomic Laws based on ICRP-60 recommendations. The Korea atomic laws require assurance that radioactive materials within gaseous effluents do not exceed dose limits and ECLs. This simply means that any effluent that would possibly contain radioactivity must be monitored. There are various methods to monitor the radioactivity of effluent monitor to satisfy the dose limits and the ECLs for gaseous effluents. The many factors (safety margin) should be considered in determining of the setpoint of effluent monitor, following these limits. In this study, we studied the determination method of alarm setpoint for gaseous effluent Radiation Monitoring Systems using dose factors considered the main pathway of radionuclides to compare the preceding determination method of alarm setpoint for gaseous effluent RMSs using dose assessment program considered all the practicable pathways of radionuclides.

  • PDF

An assessment on feasibility of flotation as a secondary clarifier of an activated sludge process (생물반응공정에 대한 고액분리조로서 부상공정의 적용성 평가)

  • Chung, Chong Min;Kim, Yun Jung;Cho, Kang Woo;Lee, Sang Hyup;Hong, Seok Won;Chung, Tai Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.5
    • /
    • pp.551-559
    • /
    • 2008
  • An experimental study was carried out to evaluate the potential of flotation process for the secondary clarifier of an activated sludge process. Flotation techniques, applied in this study, include electrofloation (EF) which generated fine bubbles smaller than $35{\mu}m$ in average and diffuser flotation (DF) which generated fine bubbles smaller than $55{\mu}m$ in average. The batch experiments were done with activated sludge displaying various characteristics. It was shown that the efficiency of solids/liquid separation was reduced as the diluted sludge volume index ($DSVI_{30}$) of activated sludge increased. The dependency, however, gradually decreased as the gas to solids (G/S) ratio increased. Thickening efficiency of EF was more than 2~10 times and DF process was more than 1.5~5 times as compared with gravity sedimentation (GS). Stable sludge blanket was maintained regardless of sludge settleability when the G/S ratio was 0.019 in the EF. On the other hand, Serious deterioration in the sludge blanket was observed in the DF depends on G/S ratio and sludge settleability. And For EF and DF, the suspended solids concentration of effluent was not nearly influenced on settleability of activated sludge and more clear than GS. A biological nutrient removal (BNR) process, combined with EF as a secondary clarifier was operated for three months. The mean MLSS (mixed liquid suspended solids) concentration in the reactor and mean solids concentration of return sludge were estimated to be 5,340 mg/L and 16,770 mg/L, respectively. The water quality of effluent was considerably stable and low value was accomplished, that was, standard suspended solids concentration $0.07{\pm}0.51mg/L$ and standard turbidity $1.44{\pm}0.56NTU$. The EF could be applicable for enhancement of efficiency of activated sludge system as well as improvement of the water quality of effluent.

Review of the Agricultural Water Quality Standards through Rice Culture with Treated Sewage Irrigation (오수처리수 관개 벼재배를 통한 농업용수 수질기준의 검토)

  • 윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.2
    • /
    • pp.44-54
    • /
    • 1999
  • Agricultural water quality standards were reviewed through rice culture using treated sewage irrigation . The seqage from school building of Konkuk University was treated by a constructed wetland system, and theeffluent of the systeml was irrigated for rice culutre after nutrient concentration adjusted by dilution. Average concentration of COD, SS, T-N and T-P in irrigated water was 22.3mg/$\ell$, 6.5mg/$\ell$, 25.8 mg/$\ell$and 2.2mg/$\ell$, respectively. Treatment include irrigation of adjusted effluent with conventional fertilization (TWCF), adjusted effluent with no fertilization (TWNF). and effluent of the wetland system as it was with no fertilization (SWNF). These treatment plots were compared with control plot irrigated by tap water with conventional fertilization (CONTROL). Other environmentals for rice culture were identical for all the plots. Among them, TWCF showed the best growth rate and the highest yield, and constituents in the harvested rice showed not much difference among them. Which implies that irrigation with relatively high nutrient concentration compared to the current water quality standards may cause no adverse effect on rice culture and could be even beneficial . Although T-N for this study was 25 times greater than the current standards, rice culture wasnot adversely affected by irrigatino water quality and even beeter results were observed than the CONTROL. It could be mistakenly that clean irrigation water produces better agricultural product, however, it is not necessarily true. Irrigation water with moderate nutrient concentration can enhance the plant growth, and better result might be expected. Therefore, peer review and modification if necessary are needed to the current agricultural water quality standards, especially for the nutrient components.

  • PDF

Analysis of the operating factors of dissolved air flotation (DAF) process for effluent quality improvement from aquaculture rearing tank (양식장 배출수 수질관리를 위한 용존공기부상 공법의 운전 인자 영향 분석)

  • Ki, Jae-Hong;Kim, Hyoung-Jun;Lee, Ju-Young;Han, Moo-Young;Gang, Hee-Woong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.107-113
    • /
    • 2012
  • Pollutants in aquaculture system effluent mostly originated from solid wastes including uneaten feed and excreta of cultured species. In this research, DAF(Dissolved Air Flotation) unit is suggested as an integrated solid control unit especially as a form of IIBG(Inline Injection Bubble Generation) process in aquaculture system. Solid removal performance of DAF unit was examined under various operation and salinity conditions with turbidity and suspended solid. Solid waste removal efficiencies were found to be affected by operation conditions including saturator pressure, recycle ratio, coagulant concentration. Solid removal efficiency was higher under higher saturator pressure and recycle ratio under which condition larger number of bubbles is generated. Coagulant is thought to have important role in creating bubble-particle aggregate by showing better removal efficiency with higher concentration. However higher saline water showed less effectiveness in removing solids by DAF(IIBG). Application of DAF(IIBG) process also showed additional effect in phosphate removal and DO(Dissolved Oxygen) supply. Phosphate existed in polluted water was removed up to 46% after treatment, which is thought to attribute to aluminium phosphate precipitation. And DO concentration was found to increase over 50% of initial saturation concentration after the injection of micro-bubbles. Through experiments on solid removal from aquaculture effluent, DAF(IIBG) process is estimated to be effective solid control method. This property can help aquaculture system being installed and operated simply and effectively.

TREATMENT OF HIGH-CONCENTRATION SWINE WASTEWATER BY ANAEROBIC DIGESTION AND AN AQUATIC PLANT SYSTEM

  • Kim, B.U.;Kwon, J.H.
    • Environmental Engineering Research
    • /
    • v.11 no.3
    • /
    • pp.134-142
    • /
    • 2006
  • The treatment of high-strength swine wastewater by anaerobic digestion combined with an aquatic plant system was investigated. Anaerobic digestion of swine wastewater gave volatile solids (VS) removal efficiencies of 43.3%, 52.1% and 54.5% for hydraulic retention times (HRTs) of 20, 30, 40 days, respectively. The removal efficiencies of VS, total chemical oxygen demand (TCOD) and soluble chemical oxygen demand (SCOD) decreased with increasing VS volumetric loading rate (VLR). Higher organic removal efficiency was observed at longer HRTs for the same VS volumetric loading rate. As VS volumetric loading rate increased, biogas production increased and the methane content of the biogas decreased. Experiments using duckweed (Lemna species) as an aquatic macrophyte gave the following results. In the case of nitrogen, removal efficiency was above 60% and effluent concentration was below 10.0 mg/L when the influent ammonia-N loading was about $1.0\;g/m^2/day$. In the case of phosphorus, removal efficiency was above 55% and effluent concentration was below 2.0 mg/L when the influent $PO_4$-P loading was about $0.15\;g/m^2/day$. In addition, crude protein and phosphorus content of duckweed biomass increased from 15.6% to 41.6% and from 0.8% to 1.6%, respectively, as the influent nutrient concentration increased. The treatment of high-strength swine wastewater by anaerobic digestion combined with an aquatic plant system offers good performance in terms of organics and nutrient removal for relatively low operation and maintenance costs. The results indicate that under appropriate operational conditions, the effluent quality is within the limits set by Korean discharge criteria.