Alarm Setpoint Determination Method of Gaseous Effluent Radiation Monitoring Systems Using Dose Factors Based on ICRP-60 Recommendations

선량환산인자를 이용한 기체유출물 RMS 경보설정 개선방안

  • Published : 2003.11.01

Abstract

In Korea, the dose limits to the public were reduced according to ICRP-60 recommendations. The secondary quantities, Effluent Concentration Limits (ECLs) were derived and enacted to Korean Atomic Laws based on ICRP-60 recommendations. The Korea atomic laws require assurance that radioactive materials within gaseous effluents do not exceed dose limits and ECLs. This simply means that any effluent that would possibly contain radioactivity must be monitored. There are various methods to monitor the radioactivity of effluent monitor to satisfy the dose limits and the ECLs for gaseous effluents. The many factors (safety margin) should be considered in determining of the setpoint of effluent monitor, following these limits. In this study, we studied the determination method of alarm setpoint for gaseous effluent Radiation Monitoring Systems using dose factors considered the main pathway of radionuclides to compare the preceding determination method of alarm setpoint for gaseous effluent RMSs using dose assessment program considered all the practicable pathways of radionuclides.

ICRP-60의 방사선방호 신개념이 국내 법령에 도입됨에 따라 원전 방사성유출물 관리의 변경이 불가피한 실정이다. 방사성유출물 관리의 중요한 요소 중의 하나가 원전 방사선감시계통(Radiation Monitoring System)의 적절한 운용이다. RMS는 원자력법에 명시되어 있는 일반인의 선량한도와 배출관리기준을 만족하도록 운용되어야 한다. 방사성유출물을 제한하는 기준에 따른 RMS 경보설정치의 비교ㆍ분석을 통해 국내 원전에 적용 가능한 최적의 개선방안을 제시할 수 있다. 본 논문에선 선량한도 기준 중 가능한 모든 피폭경로를 고려하여 예상선량률을 계산한 선행 RMS 경보설정 개선방안과의 비교를 위해 주요 피폭경로만 고려하는 선량환산인자에 의한 예상선량률 계산과 RMS 경보설정 개선방안을 조사하였다.

Keywords